{"id":9067,"date":"2026-08-18T05:54:12","date_gmt":"2026-08-18T05:54:12","guid":{"rendered":"https:\/\/airmate.cc\/?page_id=9067"},"modified":"2026-08-23T12:08:53","modified_gmt":"2026-08-23T12:08:53","slug":"sensor-library","status":"publish","type":"page","link":"https:\/\/airmate.cc\/zh\/sensor-library\/","title":{"rendered":"Sensor Library | \u4f20\u611f\u5668\u8d44\u6599\u5e93"},"content":{"rendered":"\n<style>\n#sensor-library{--sl-navy:#123047;--sl-teal:#0f766e;--sl-blue:#2563a6;--sl-line:#d7e1e7;--sl-bg:#f5f8fa;max-width:1240px;margin:0 auto;padding:34px 20px 60px;color:#18323f;font-family:Arial,\"Microsoft YaHei\",sans-serif}#sensor-library *{box-sizing:border-box}.sl-hero{padding:34px;border-radius:18px;background:linear-gradient(135deg,var(--sl-navy),#1e526b);color:#fff;margin-bottom:18px}.sl-hero h1{color:#fff;margin:0 0 10px;font-size:clamp(28px,4vw,46px);line-height:1.15}.sl-hero p{margin:0;max-width:850px;font-size:16px;opacity:.9}.sl-summary,.sl-brand-quicks{display:flex;gap:10px;flex-wrap:wrap;margin-top:18px}.sl-summary span{background:rgba(255,255,255,.12);padding:8px 13px;border-radius:999px;font-size:14px}.sl-brand-quick{border:1px solid rgba(255,255,255,.45);background:transparent;color:#fff;border-radius:999px;padding:8px 13px;cursor:pointer}.sl-brand-quick.is-active{background:#fff;color:var(--sl-navy);border-color:#fff;font-weight:700}.sl-toolbar{position:sticky;top:0;z-index:8;background:#fff;border:1px solid var(--sl-line);box-shadow:0 8px 28px rgba(18,48,71,.08);border-radius:16px;padding:16px;margin-bottom:20px}.sl-controls{display:grid;grid-template-columns:2fr repeat(4,1fr) auto;gap:10px}.sl-controls input,.sl-controls select,.sl-controls button{width:100%;min-height:44px;border:1px solid #bdcbd3;border-radius:9px;background:#fff;padding:8px 11px;font-size:14px;color:#18323f}.sl-controls button{cursor:pointer;background:var(--sl-navy);color:#fff;border-color:var(--sl-navy);font-weight:700}.sl-resultbar{display:flex;justify-content:space-between;gap:12px;margin-top:12px;font-size:14px;color:#506671}.sl-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:16px;align-items:start}.sl-card{display:flex;flex-direction:column;gap:12px;height:710px;background:#fff;border:1px solid var(--sl-line);border-radius:15px;padding:18px;box-shadow:0 5px 18px rgba(18,48,71,.05)}.sl-card:has(details[open]){height:auto;min-height:710px}.sl-card-top{display:flex;justify-content:space-between;gap:8px;align-items:center;height:30px;min-height:30px}.sl-card-top .sl-gas{max-width:68%;white-space:nowrap;overflow:hidden;text-overflow:ellipsis}.sl-brand,.sl-gas{font-size:12px;border-radius:999px;padding:5px 9px}.sl-brand{font-weight:700}.sl-brand[data-brand-key=semeatech]{background:#e7f3f1;color:var(--sl-teal)}.sl-brand[data-brand-key=membrapor]{background:#e8f0fb;color:var(--sl-blue)}.sl-brand[data-brand-key=alphasense]{background:#f1eafe;color:#6941c6}.sl-brand[data-brand-key=nemoto]{background:#fff1df;color:#9a4f00}.sl-brand[data-brand-key=honeywell]{background:#fdecec;color:#b42318}.sl-brand[data-brand-key=city]{background:#e8f5fc;color:#086b9d}.sl-brand[data-brand-key=figaro]{background:#e9f7ed;color:#23733a}.sl-brand[data-brand-key=ecsense]{background:#eef0fb;color:#24298f}.sl-brand[data-brand-key=sgx]{background:#e7f6fb;color:#087aa3}.sl-brand[data-brand-key=susa]{background:#fff2db;color:#985c00}.sl-brand[data-brand-key=hh]{background:#eef4ff;color:#2858a8}.sl-gas{background:#edf3f7;color:var(--sl-navy)}.sl-image-wrap{height:180px;min-height:180px;display:flex;align-items:center;justify-content:center;background:#f7fafb;border:1px solid var(--sl-line);border-radius:12px;overflow:hidden}.sl-product-image{display:block;width:100%;height:100%;object-fit:contain;padding:10px}.sl-card h3{margin:0;color:var(--sl-navy);font-size:23px;line-height:1.2;height:34px;min-height:34px;display:-webkit-box;-webkit-line-clamp:1;-webkit-box-orient:vertical;overflow:hidden}.sl-series{margin:-5px 0 0;color:#617580;font-size:13px;line-height:1.4;height:36px;min-height:36px;display:-webkit-box;-webkit-line-clamp:2;-webkit-box-orient:vertical;overflow:hidden}.sl-specs{display:grid;grid-template-columns:1fr 1fr;height:194px;min-height:194px;border:1px solid var(--sl-line);border-radius:10px;overflow:hidden}.sl-specs div{height:96px;padding:10px;border-bottom:1px solid var(--sl-line);display:flex;flex-direction:column;justify-content:center;overflow:hidden}.sl-specs div:nth-child(odd){border-right:1px solid var(--sl-line)}.sl-specs div:nth-last-child(-n+2){border-bottom:0}.sl-specs div:last-child:nth-child(odd){grid-column:1\/-1;border-right:0}.sl-specs small{display:block;color:#70838d;margin-bottom:4px}.sl-specs strong{font-size:13px;line-height:1.35;color:#203b48;word-break:break-word;display:-webkit-box;-webkit-line-clamp:3;-webkit-box-orient:vertical;overflow:hidden}.sl-extra{display:grid;gap:4px;height:52px;min-height:52px;align-content:start;overflow:hidden;color:#526a75;font-size:12px}.sl-card details{font-size:13px;color:#4f6671;min-height:24px}.sl-card details[open] p{max-height:140px;overflow:auto}.sl-card summary{cursor:pointer;color:var(--sl-teal);font-weight:700}.sl-card details p{line-height:1.6;margin:8px 0 0}.sl-actions{display:flex;gap:8px;flex-wrap:wrap;min-height:38px;margin-top:auto}.sl-btn{display:inline-flex;align-items:center;justify-content:center;flex:1 1 140px;min-height:38px;padding:9px 12px;border-radius:8px;text-decoration:none!important;font-size:13px;font-weight:700}.sl-btn-primary{background:var(--sl-teal);color:#fff!important}.sl-details-trigger{border:0;cursor:pointer;font-family:inherit}.sl-modal{width:min(760px,calc(100vw - 32px));max-height:min(86vh,900px);padding:0;border:0;border-radius:16px;color:#18323f;background:#fff;box-shadow:0 24px 70px rgba(18,48,71,.28)}.sl-modal::backdrop{background:rgba(12,31,43,.62)}.sl-modal-shell{padding:0}.sl-modal-head{position:sticky;top:0;z-index:1;display:flex;align-items:flex-start;justify-content:space-between;gap:18px;padding:20px 22px;border-bottom:1px solid var(--sl-line);background:#fff}.sl-modal-kicker{display:block;margin-bottom:5px;color:var(--sl-teal);font-size:12px;font-weight:700;letter-spacing:.04em;text-transform:uppercase}.sl-modal-title{margin:0;color:var(--sl-navy);font-size:26px;line-height:1.2}.sl-modal-close{border:1px solid var(--sl-line);border-radius:8px;background:#f7fafb;color:var(--sl-navy);padding:8px 12px;cursor:pointer;font:700 13px\/1 Arial,\"Microsoft YaHei\",sans-serif}.sl-modal-body{padding:22px}.sl-modal-meta{display:flex;flex-wrap:wrap;gap:8px;margin-bottom:16px}.sl-modal-meta span{border-radius:999px;background:#edf3f7;color:var(--sl-navy);padding:6px 10px;font-size:12px}.sl-modal-description{margin:0 0 18px;color:#425e6b;font-size:14px;line-height:1.75}.sl-modal-specs{display:grid;grid-template-columns:1fr 1fr;border:1px solid var(--sl-line);border-radius:12px;overflow:hidden}.sl-modal-spec{min-height:92px;padding:14px;border-bottom:1px solid var(--sl-line);display:flex;flex-direction:column;justify-content:center}.sl-modal-spec:nth-child(odd){border-right:1px solid var(--sl-line)}.sl-modal-spec:nth-last-child(-n+2){border-bottom:0}.sl-modal-spec small{color:#70838d;margin-bottom:5px}.sl-modal-spec strong{color:#203b48;font-size:14px;line-height:1.45;word-break:break-word}.sl-modal-extra{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;margin-top:14px}.sl-modal-extra div{border:1px solid var(--sl-line);border-radius:10px;padding:11px;background:#f7fafb}.sl-modal-extra small{display:block;color:#70838d;margin-bottom:4px}.sl-modal-extra strong{font-size:13px;line-height:1.4;color:#203b48;word-break:break-word}@media(max-width:680px){.sl-modal{width:calc(100vw - 20px)}.sl-modal-head,.sl-modal-body{padding:16px}.sl-modal-title{font-size:22px}.sl-modal-specs,.sl-modal-extra{grid-template-columns:1fr}.sl-modal-spec{border-right:0!important;border-bottom:1px solid var(--sl-line)!important}.sl-modal-spec:last-child{border-bottom:0!important}}.sl-btn-disabled{background:#e8edf0;color:#82929a}.sl-pages{display:flex;align-items:center;justify-content:center;gap:12px;margin-top:24px}.sl-pages button{border:1px solid var(--sl-line);border-radius:9px;padding:10px 16px;background:#fff;color:var(--sl-navy);cursor:pointer;font-weight:700}.sl-pages button:disabled{opacity:.4;cursor:not-allowed}.sl-note{margin-top:28px;background:var(--sl-bg);border-left:4px solid var(--sl-teal);padding:16px 18px;color:#526a75;font-size:13px;line-height:1.6}.sl-empty{text-align:center;padding:50px 15px;border:1px dashed #bac8cf;border-radius:14px;background:#fff;color:#607580}\n@media(max-width:1050px){.sl-controls{grid-template-columns:1fr 1fr 1fr}.sl-grid{grid-template-columns:repeat(2,minmax(0,1fr))}}@media(max-width:680px){#sensor-library{padding:20px 12px 45px}.sl-hero{padding:25px 20px}.sl-toolbar{position:static}.sl-controls{grid-template-columns:1fr}.sl-grid{grid-template-columns:1fr}.sl-resultbar{flex-direction:column}.sl-card{padding:16px}.sl-image-wrap{height:150px}}\n.sl-modal-documents{margin-top:18px;padding-top:16px;border-top:1px solid #d7e2df}.sl-modal-documents-title{display:block;margin-bottom:10px;color:#163d36;font-size:.9rem}.sl-modal-documents .sl-actions{display:flex;flex-wrap:wrap;gap:10px}.sl-modal-doc-note{margin:18px 0 0;padding:12px 14px;border-radius:10px;background:#fff8e8;color:#624f22;font-size:.9rem;line-height:1.6}.sl-modal-documents .sl-modal-doc-note{margin-top:12px}\n@media(max-width:680px){.sl-grid{grid-template-columns:minmax(0,1fr);min-width:0}.sl-card{width:100%;max-width:100%;min-width:0}.sl-card-top,.sl-image-wrap,.sl-card h3,.sl-series,.sl-specs,.sl-extra,.sl-actions{min-width:0}.sl-card-top .sl-brand,.sl-card-top .sl-gas,.sl-btn{min-width:0}.sl-specs{grid-template-columns:repeat(2,minmax(0,1fr))}}<\/style>\n<section id=\"sensor-library\" aria-label=\"Sensor Library\" data-aria-en=\"Sensor Library\" data-aria-zh=\"\u4f20\u611f\u5668\u8d44\u6599\u5e93\">\n<div class=\"sl-hero\"><h1 data-en=\"Sensor Library\" data-zh=\"\u4f20\u611f\u5668\u8d44\u6599\u5e93\">Sensor Library<\/h1><p data-en=\"Browse sensors by brand, gas type, sensing technology, and product series. Compare key specifications and open available documentation.\" data-zh=\"\u6309\u54c1\u724c\u3001\u6c14\u4f53\u7c7b\u578b\u3001\u68c0\u6d4b\u539f\u7406\u548c\u4ea7\u54c1\u7cfb\u5217\u67e5\u627e\u4f20\u611f\u5668\uff0c\u5e76\u76f4\u63a5\u67e5\u770b\u5173\u952e\u6027\u80fd\u53c2\u6570\u4e0e\u76f8\u5173\u8d44\u6599\u3002\">Browse sensors by brand, gas type, sensing technology, and product series. Compare key specifications and open available documentation.<\/p><div class=\"sl-summary\"><span data-en=\"1506 models\" data-zh=\"1506 \u4e2a\u578b\u53f7\">1506 models<\/span><span data-en=\"61 gas \/ detection categories\" data-zh=\"61 \u4e2a\u6c14\u4f53\/\u68c0\u6d4b\u7c7b\u522b\">61 gas \/ detection categories<\/span><span data-en=\"11 brands\" data-zh=\"11 \u4e2a\u54c1\u724c\">11 brands<\/span><\/div><div id=\"sl-brand-quicks\" class=\"sl-brand-quicks\"><button type=\"button\" class=\"sl-brand-quick is-active\" data-brand-key=\"\" data-en=\"All Brands (1506)\" data-zh=\"\u5168\u90e8\u54c1\u724c (1506)\">All Brands (1506)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"semeatech\" data-en=\"SemeaTech (284)\" data-zh=\"\u76db\u5bc6 (284)\">SemeaTech (284)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"membrapor\" data-en=\"Membrapor (278)\" data-zh=\"\u8499\u5df4\u6ce2 (278)\">Membrapor (278)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"alphasense\" data-en=\"Alphasense (113)\" data-zh=\"\u963f\u5c14\u6cd5 (113)\">Alphasense (113)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"nemoto\" data-en=\"Nemoto (51)\" data-zh=\"\u65e5\u672c\u6839\u672c (51)\">Nemoto (51)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"honeywell\" data-en=\"Honeywell (66)\" data-zh=\"\u970d\u5c3c\u97e6\u5c14 (66)\">Honeywell (66)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"city\" data-en=\"City Technology (186)\" data-zh=\"\u57ce\u5e02\u6280\u672f (186)\">City Technology (186)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"figaro\" data-en=\"Figaro (42)\" data-zh=\"\u8d39\u52a0\u7f57 (42)\">Figaro (42)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"ecsense\" data-en=\"EC Sense (299)\" data-zh=\"\u5fb7\u56fdEC (299)\">EC Sense (299)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"sgx\" data-en=\"SGX Sensortech (7)\" data-zh=\"SGX (7)\">SGX Sensortech (7)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"susa\" data-en=\"SUSA (71)\" data-zh=\"\u82cf\u8428 (71)\">SUSA (71)<\/button><button type=\"button\" class=\"sl-brand-quick\" data-brand-key=\"hh\" data-en=\"HH (109)\" data-zh=\"\u534e\u6df1\u79d1 (109)\">HH (109)<\/button><\/div><\/div>\n<div class=\"sl-toolbar\"><div class=\"sl-controls\"><input id=\"sl-search\" type=\"search\" placeholder=\"Search model, gas, brand, or keyword\" data-placeholder-en=\"Search model, gas, brand, or keyword\" data-placeholder-zh=\"\u641c\u7d22\u578b\u53f7\u3001\u6c14\u4f53\u3001\u54c1\u724c\u6216\u5173\u952e\u8bcd\" aria-label=\"Search sensors\" data-aria-en=\"Search sensors\" data-aria-zh=\"\u641c\u7d22\u4f20\u611f\u5668\"><select id=\"sl-brand\" aria-label=\"Filter by brand\" data-aria-en=\"Filter by brand\" data-aria-zh=\"\u6309\u54c1\u724c\u7b5b\u9009\"><\/select><select id=\"sl-gas\" aria-label=\"Filter by gas type\" data-aria-en=\"Filter by gas type\" data-aria-zh=\"\u6309\u6c14\u4f53\u7c7b\u578b\u7b5b\u9009\"><\/select><select id=\"sl-tech\" aria-label=\"Filter by sensing technology\" data-aria-en=\"Filter by sensing technology\" data-aria-zh=\"\u6309\u68c0\u6d4b\u539f\u7406\u7b5b\u9009\"><\/select><select id=\"sl-series\" aria-label=\"Filter by series\" data-aria-en=\"Filter by series\" data-aria-zh=\"\u6309\u7cfb\u5217\u7b5b\u9009\"><\/select><button id=\"sl-reset\" type=\"button\" data-en=\"Reset\" data-zh=\"\u91cd\u7f6e\">Reset<\/button><\/div><div class=\"sl-resultbar\" aria-live=\"polite\"><span id=\"sl-count\"><\/span><span id=\"sl-page-label\"><\/span><\/div><\/div>\n<div id=\"sl-grid\" class=\"sl-grid\"><\/div><div id=\"sl-empty\" class=\"sl-empty\" hidden data-en=\"No matching models found. Please adjust the search or filters.\" data-zh=\"\u6ca1\u6709\u627e\u5230\u7b26\u5408\u6761\u4ef6\u7684\u578b\u53f7\uff0c\u8bf7\u8c03\u6574\u641c\u7d22\u6216\u7b5b\u9009\u6761\u4ef6\u3002\">No matching models found. Please adjust the search or filters.<\/div><nav class=\"sl-pages\" aria-label=\"Library pagination\" data-aria-en=\"Library pagination\" data-aria-zh=\"\u8d44\u6599\u5e93\u5206\u9875\"><button id=\"sl-prev\" type=\"button\" data-en=\"Previous\" data-zh=\"\u4e0a\u4e00\u9875\">Previous<\/button><span id=\"sl-page\">1 \/ 1<\/span><button id=\"sl-next\" type=\"button\" data-en=\"Next\" data-zh=\"\u4e0b\u4e00\u9875\">Next<\/button><\/nav><div class=\"sl-note\" data-en=\"This catalog contains SemeaTech, Membrapor, Alphasense, Nemoto, Honeywell, City Technology, Figaro, EC Sense, and SGX Sensortech sensor data. Specifications support rapid multilingual selection; for design, calibration, and safety-critical use, confirm the latest applicable manufacturer revision.\" data-zh=\"\u5f53\u524d\u8d44\u6599\u5e93\u6536\u5f55 SemeaTech\u3001Membrapor\u3001Alphasense\u3001Nemoto\u3001Honeywell\u3001City Technology\u3001Figaro\u3001EC Sense \u4e0e SGX Sensortech \u4f20\u611f\u5668\u8d44\u6599\u3002\u9875\u9762\u63d0\u4f9b\u9002\u5408\u591a\u8bed\u8a00\u6d4f\u89c8\u7684\u5173\u952e\u53c2\u6570\uff0c\u5177\u4f53\u8bbe\u8ba1\u3001\u6807\u5b9a\u548c\u5b89\u5168\u5e94\u7528\u4ecd\u9700\u786e\u8ba4\u9002\u7528\u7684\u539f\u5382\u6700\u65b0\u4fee\u8ba2\u8d44\u6599\u3002\">This catalog contains SemeaTech, Membrapor, Alphasense, Nemoto, Honeywell, City Technology, Figaro, EC Sense, and SGX Sensortech sensor data. Specifications support rapid multilingual selection; for design, calibration, and safety-critical use, confirm the latest applicable manufacturer revision.<\/div><dialog id=\"sl-details-dialog\" class=\"sl-modal\" role=\"dialog\" aria-modal=\"true\" aria-labelledby=\"sl-dialog-title\" aria-describedby=\"sl-dialog-description\"><div class=\"sl-modal-shell\"><div class=\"sl-modal-head\"><div><span id=\"sl-dialog-kicker\" class=\"sl-modal-kicker\">Sensor Details<\/span><h2 id=\"sl-dialog-title\" class=\"sl-modal-title\"><\/h2><\/div><button id=\"sl-dialog-close\" class=\"sl-modal-close\" type=\"button\" autofocus>Close<\/button><\/div><div id=\"sl-dialog-body\" class=\"sl-modal-body\"><\/div><\/div><\/dialog><\/section>\n<script type=\"application\/json\" id=\"sl-catalog-data\">{\"products\":[{\"id\":\"semeatech:b54e03a03f27e12486a0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"WC Air Quality\",\"seriesKey\":\"semeatech:item-bda9deb8\",\"series\":{\"en\":\"Consumer Sensors\",\"zh\":\"\u6c11\u7528\u4f20\u611f\u5668\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.150 \u00b1 0.035 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a090\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech WC Air Quality uses electrochemical sensing for Air Quality, with a measuring range of 0 ~ 20 ppm. It belongs to the Consumer Sensors family.\",\"zh\":\"WC Air Quality\u4f20\u611f\u5668\u4e13\u4e3a\u667a\u6167\u57ce\u5e02\u4e2d\u7684\u76e5\u6d17\u5ba4\u81ed\u5473\u68c0\u6d4b\u5e94\u7528\u800c\u8bbe\u8ba1\u3002\u63a8\u8350\u5728\u7a33\u5b9a\u7684\u6e29\u6e7f\u5ea6\u6761\u4ef6\u4e0b\u4f7f\u7528\u8be5\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/wc-air-quality-06671f9eb0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-wc-air-quality-f68b334dd50a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f949a19e45bc79637314\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4AsH3-1\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1\u00a0ppm\",\"sensitivity\":\"3.0 \u00b1 0.6\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 45\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.005\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4AsH3-1 uses electrochemical sensing for Arsine, with a measuring range of 0 ~ 1\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7837\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u7837\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ash3-1-21ab0bfa5d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ash3-1-665af7a79bab.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:55831efa4cb1c1afa818\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4AsH3-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.6 \u00b1 0.2\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 45\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 pp\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4AsH3-10 uses electrochemical sensing for Arsine, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7837\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u7837\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ash3-10-71a63fca4a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ash3-10-9772abf919ae.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:29348a04ec475de9e782\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini AsH3-10\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.6 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini AsH3-10 uses electrochemical sensing for Arsine, with a measuring range of 0 ~ 10 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7837\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-ash3-10-4f07ebe0df.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-ash3-10-e06860f6a37a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d91fc25fad8ddddbb5cb\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4Br2-1\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"BR2\",\"gasName\":{\"en\":\"Bromine\",\"zh\":\"\u6eb4\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1\u00a0ppm\",\"sensitivity\":\"-0.25 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"1\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4Br2-1 uses electrochemical sensing for Bromine, with a measuring range of 0 ~ 1\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u6eb4\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6eb4\u6c14\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4br2-1-709612ac8c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4br2-1-7399eee1c2bf.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d2e4fea7cd31afb3cfd0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4Br2-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"BR2\",\"gasName\":{\"en\":\"Bromine\",\"zh\":\"\u6eb4\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"-0.20 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"1\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4Br2-10 uses electrochemical sensing for Bromine, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u6eb4\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6eb4\u6c14\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4br2-10-4446217aab.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4br2-10-f728314f4f90.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:6880bddc1be8193610a7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4Br2-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"BR2\",\"gasName\":{\"en\":\"Bromine\",\"zh\":\"\u6eb4\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"-0.15 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.015 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"1\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4Br2-100 uses electrochemical sensing for Bromine, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u6eb4\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6eb4\u6c14\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4br2-100-ab93c0a69f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4br2-100-a1af1ca333ec.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d12e96e39f635ac91ef7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H2-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.2 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H2-10 uses electrochemical sensing for Acetylene, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e59\u7094\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e59\u7094\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h2-10-62cad63d47.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h2-10-f4f791f03d82.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:66cfadd8e7f098eafb81\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H2-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.10 \u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H2-100 uses electrochemical sensing for Acetylene, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e59\u7094\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e59\u7094\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h2-100-47809317f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h2-100-6a086beccda1.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:546c8e3f1b682aa10b4e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H2-200\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"0.065\u00a0\u00b1 0.020 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H2-200 uses electrochemical sensing for Acetylene, with a measuring range of 0 ~ 200 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e59\u7094\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e59\u7094\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h2-200-d3b5d97aed.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h2-200-8a6901264a64.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:40246da0b0c6e40de0ed\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H3CL-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H3CL\",\"gasName\":{\"en\":\"Vinyl Chloride\",\"zh\":\"\u6c2f\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.185 \u00b1 0.085 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H3CL-100 uses electrochemical sensing for Vinyl Chloride, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u4e59\u70ef\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u4e59\u70ef\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h3cl-100-6e806feff2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h3cl-100-bea0a60577f8.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:03a5ceac40f800c86b3a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H3CL-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H3CL\",\"gasName\":{\"en\":\"Vinyl Chloride\",\"zh\":\"\u6c2f\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.5 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H3CL-20 uses electrochemical sensing for Vinyl Chloride, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u4e59\u70ef\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u4e59\u70ef\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h3cl-20-8ca03e8506.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h3cl-20-c44323f6a37b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:da6cbab1ee97035338a9\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7C2H3CL-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"C2H3CL\",\"gasName\":{\"en\":\"Vinyl Chloride\",\"zh\":\"\u6c2f\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.185 \u00b1 0.085 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7C2H3CL-100 uses electrochemical sensing for Vinyl Chloride, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u4e59\u70ef\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c2f\u4e59\u70ef\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7c2h3cl-100-528e195ce1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7c2h3cl-100-8b67e5ef4109.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e16403f836104ec783ce\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7C2H3CL-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"C2H3CL\",\"gasName\":{\"en\":\"Vinyl Chloride\",\"zh\":\"\u6c2f\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.4 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7C2H3CL-50 uses electrochemical sensing for Vinyl Chloride, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u4e59\u70ef\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c2f\u4e59\u70ef\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7c2h3cl-50-0bf798dc52.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7c2h3cl-50-d785e77af211.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:25da07ac3a07e23101b2\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H4-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.4 \u00b1 0.3 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H4-10 uses electrochemical sensing for Ethylene, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e59\u70ef\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e59\u70ef\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h4-10-2ed8b6e692.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h4-10-bcb9d5e8444e.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d5be9bea7e8df0eba152\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H4-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.8 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H4-100 uses electrochemical sensing for Ethylene, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e59\u70ef\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e59\u70ef\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h4-100-0b544194da.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h4-100-cf020588e014.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:29c85a6206469976bf7e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C2H4-200\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"0.065 \u00b1 0.025 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C2H4-200 uses electrochemical sensing for Ethylene, with a measuring range of 0 ~ 200 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e59\u70ef\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e59\u70ef\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c2h4-200-fe56e1aae1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c2h4-200-466c543833fe.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:04089a006bf73d983c41\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4C3H3N-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"C3H3N\",\"gasName\":{\"en\":\"Acrylonitrile\",\"zh\":\"\u4e19\u70ef\u8148\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.25 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4C3H3N-50 uses electrochemical sensing for Acrylonitrile, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e19\u70ef\u8148\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e19\u70ef\u8148\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4c3h3n-50-a7834ed50e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4c3h3n-50-ee5fc0840f5a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:277d1c9556ebc75a2a9b\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CH2O-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"2 \u00b1 1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CH2O-10 uses electrochemical sensing for Formaldehyde, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7532\u919b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u7532\u919b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ch2o-10-9ec9fd1616.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ch2o-10-8ced362cdd8d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:df8c2171ef608289e2d4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CH2O-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.55 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CH2O-50 uses electrochemical sensing for Formaldehyde, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7532\u919b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u7532\u919b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ch2o-50-b4e2abb1b2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ch2o-50-f9259adc3696.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:215fb7f4610267a5632d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CH2O-10\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"2\u00a0\u00b1 1\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CH2O-10 uses electrochemical sensing for Formaldehyde, with a measuring range of 0 ~ 10 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7532\u919b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u7532\u919b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7ch2o-10-ee500d50ec.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7ch2o-10-07cb4d1ead30.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2c86205e0d0673287be8\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CH2O-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.55 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CH2O-50 uses electrochemical sensing for Formaldehyde, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7532\u919b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u7532\u919b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7ch2o-50-fde5a34bfc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7ch2o-50-28eb4fd63a41.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d01a98f11dec41c4c421\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CH3SH-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.70 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CH3SH-10 uses electrochemical sensing for Methanethiol, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7532\u786b\u9187\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u7532\u786b\u9187\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ch3sh-10-a5cabf4ba7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ch3sh-10-f3c45d6c25c3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:305c5d9a7c9e3db6b1f9\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CH3SH-10\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.75 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CH3SH-10 uses electrochemical sensing for Methanethiol, with a measuring range of 0 ~ 10 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7532\u786b\u9187\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u7532\u786b\u9187\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7ch3sh-10-232c20fcec.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7ch3sh-10-6aac1e8e87e8.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:85a29e43990cd2dd5e0d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini CH3SH-10\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10\u00a0ppm\",\"sensitivity\":\"0.35 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.015 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini CH3SH-10 uses electrochemical sensing for Methanethiol, with a measuring range of 0 ~ 10\u00a0ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7532\u786b\u9187\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-ch3sh-10-59f98695ed.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-ch3sh-10-a8b65b5be4f3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a35d99fe7eddbead3ae4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CL2-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"-0.75 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CL2-10 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4cl2-10-707de5260a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4cl2-10-67c881e9f8ee.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:41a850c05649239447b7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CL2-1000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"-0.15 \u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CL2-1000 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4cl2-1000-d7fc248daf.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4cl2-1000-e85a015f5291.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f5f65f48d51701e87dcb\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CL2-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.55 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CL2-20 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4cl2-20-ff981729dc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4cl2-20-719c23a9f56b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:bb3e9c68828ff504084e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CL2-200\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"-0.18 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CL2-200 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 200 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4cl2-200-059cc6d554.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4cl2-200-b3975fe9f988.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:87a83e3c6e7b1e6c05c7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CL2-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"-0.45 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CL2-50 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4cl2-50-1a5707858b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4cl2-50-fa52e01f2e6b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7ada880f0947f58b5d0e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMCL2-5\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5 ppm\",\"sensitivity\":\"-0.75 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.008 ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMCL2-5 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 5 ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u6c2f\u6c14\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smcl2-5-0648a4e4d3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smcl2-5-ef1cf354642a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:922b7f7caf3a4c2676c6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CL2-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-1.00 \u00b1 0.25 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CL2-20 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 20 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c2f\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7cl2-20-1c2c222e11.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7cl2-20-d77c229d22b8.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ccf7534e37626694abff\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CL2-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"-0.85 \u00b1 0.25 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CL2-50 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c2f\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7cl2-50-3642849286.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7cl2-50-ef853afb0d78.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5d74f8ff5650d07453c4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini CL2-20\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.25 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini CL2-20 uses electrochemical sensing for Chlorine, with a measuring range of 0 ~ 20 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-cl2-20-608626186b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-cl2-20-c8d8237a408c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c26210177c16d7a292da\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CLO2-1\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1\u00a0ppm\",\"sensitivity\":\"-0.65 \u00b1 0.30 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.03\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CLO2-1 uses electrochemical sensing for Chlorine Dioxide, with a measuring range of 0 ~ 1\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2f\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2f\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4clo2-1-8d4e8cc743.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4clo2-1-55ae800699fa.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5a3fcdf59e644a76c60b\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CLO2-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"-0.6\u00a0\u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.15 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CLO2-10 uses electrochemical sensing for Chlorine Dioxide, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2f\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2f\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4clo2-10-ef32323e3f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4clo2-10-39c170fbabc6.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d85ccfc801de767ce6e0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CLO2-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"-0.40 \u00b1 0.18 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CLO2-50 uses electrochemical sensing for Chlorine Dioxide, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2f\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2f\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4clo2-50-3cef48e6b3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4clo2-50-f379db873acb.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:127977e8bf4191e0d569\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CLO2-1\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1 ppm\",\"sensitivity\":\"-0.8 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CLO2-1 uses electrochemical sensing for Chlorine Dioxide, with a measuring range of 0 ~ 1 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2f\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2f\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7clo2-1-3f84853ed2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7clo2-1-f6d43bac149b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:29e7b54ce3701f02ba92\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CLO2-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.7 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CLO2-20 uses electrochemical sensing for Chlorine Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2f\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2f\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7clo2-20-d193bb8b45.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7clo2-20-223281ce4c48.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:77f0754802dc7f823dc5\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3CO-10000\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10000 ppm\",\"sensitivity\":\"0.030 \u00b1 0.006 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3CO-10000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 10000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3co-10000-218dba5a1d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3co-10000-f94ca4c04538.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7e2bbef4fd8ae951d212\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3CO-10000CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10000 ppm\",\"sensitivity\":\"0.030 \u00b1 0.006 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3CO-10000CT uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 10000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e00\u6c27\u5316\u78b3\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3co-10000ct-b41a4cbdbf.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3co-10000ct-24902a53afb9.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:46d2a7e96bb84cd621dd\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3CO-2000\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3CO-2000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3co-2000-5e5bc9a57d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3co-2000-c56050aee95f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:20f0a546939bf014b72b\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3CO-20000\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20000 ppm\",\"sensitivity\":\"0.015 \u00b1 0.004 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3CO-20000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 20000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3co-20000-1f769f03d4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3co-20000-30a8433441ae.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:bbec41db8c29581a0586\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3CO-4000CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 4000 ppm\",\"sensitivity\":\"0.030 \u00b1 0.006 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3CO-4000CT uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 4000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e00\u6c27\u5316\u78b3\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3co-4000ct-81f883e6f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3co-4000ct-81f114d194ff.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c5af502b23bf6556e7a7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.4\u00a0\u00b1 0.1\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-100 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-100-3e13bb3880.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-100-c90365ba8312.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:9ee98fb175b974f45526\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-1000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000\u00a0ppm\",\"sensitivity\":\"0.060 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-1000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 1000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-1000-d721ea57cb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-1000-f95256ce5198.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:19aabd2b5bab74a69c57\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-10000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10000\u00a0ppm\",\"sensitivity\":\"0.0175 \u00b1 0.0075 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-10000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 10000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-10000-9b902cb390.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-10000-e7bb3ccaff0d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:484c86005517a6e5c159\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-1000C\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.060 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 15\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"7 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-1000C uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\u3002\u5b83\u5df2\u901a\u8fc7UL2075\u8ba4\u8bc1\uff0c\u7b26\u5408\u4f4f\u5b85\u548c\u5546\u7528\u6c14\u4f53\u68c0\u6d4b\u8bbe\u5907\u7684\u8981\u6c42\uff0c\u53ef\u786e\u4fdd\u5b89\u5168\u3001\u53ef\u9760\u4e14\u51c6\u786e\u7684\u8fd0\u884c\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-1000c-f1db8e0803.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-1000c-3e68dbccde0d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3494754282979bbd76ac\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-1000S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000\u00a0ppm\",\"sensitivity\":\"0.060 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-1000S uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 1000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-1000s-22469f83aa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-1000s-c89bd42738a4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:75a04bd5a40a6cc472fb\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-100N\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.08 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 15\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-100N uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-100n-a932788ada.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-100n-c2fd4c54a082.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:8abaf67895ecc13bc4d5\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000\u00a0ppm\",\"sensitivity\":\"0.028 \u00b1 0.010 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-2000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 2000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-2000-d141a0f8c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-2000-0dbceb8acd09.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b0a14be976300a5b38ba\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-20000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20000\u00a0ppm\",\"sensitivity\":\"0.015 \u00b1 0.005 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-20000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 20000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-20000-06c4996f06.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-20000-a1432b2170ef.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2249e3f73e53691d978d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-2000CT\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000\u00a0ppm\",\"sensitivity\":\"0.075 \u00b1 0.020 \u03bcA\/ppm\",\"responseTime\":\"\u2264 15\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-2000CT uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 2000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u8be5\u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\u7ecf\u8fc7\u4e13\u95e8\u8bbe\u8ba1\uff0c\u5177\u6709\u826f\u597d\u7684\u7a33\u5b9a\u6027\u548c\u66f4\u77ed\u7684 \u54cd\u5e94\u65f6\u95f4\uff0c\u53ef\u66ff\u6362\u5176\u4ed6\u516c\u53f8\u751f\u4ea7\u7684\u6807\u51c64\u7cfb\u5217\u7535\u5316\u5b66\u4e00\u6c27\u5316\u78b3 \u4f20\u611f\u5668\u3002\u5b83\u5bf9\u4e00\u6c27\u5316\u6c2e\u57fa\u672c\u65e0\u5e72\u6270\uff0c\u66f4\u9002\u7528\u4e8e\u77ff\u5c71\u884c\u4e1a\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-2000ct-9e5d4ae15c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-2000ct-fd952d8bd860.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:86bdc8de1ee19bf0bc0a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0ppm\",\"sensitivity\":\"0.5 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.15 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-50 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 50\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-50-f729d34160.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-50-524b01a3e2ce.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3083898c36eecdf91d6a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-500\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500\u00a0ppm\",\"sensitivity\":\"0.075\u00a0\u00b1 0.020 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-500 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 500\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-500-233b674273.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-500-a403b3615da1.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a6aa20f09418564fcb51\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-5000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5000\u00a0ppm\",\"sensitivity\":\"0.025 \u00b1 0.010 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"8\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-5000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 5000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-5000-c18faf0a16.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-5000-7f83279f6042.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f7087c2cc5ac47752e8b\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO-500S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500\u00a0ppm\",\"sensitivity\":\"0.075 \u00b1 0.020 \u03bcA\/ppm\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO-500S uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 500\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co-500s-2c9a61ad8f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co-500s-c340a1f8a1bf.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:6986942587d4cce05162\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMCO-100\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.075 \u00b1 0.020 \u03bcA\/ppm\",\"responseTime\":\"\u2264 15\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1\u00a0ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMCO-100 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smco-100-2514679429.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smco-100-676cf31b0799.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3f8834ddd0ef9523df0d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CO-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.25 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CO-100 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7co-100-13062156f6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7co-100-f05db45bc487.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5a8e023ba8c2a7915a49\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CO-1000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000\u00a0ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.75 ppm\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CO-1000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 1000\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7co-1000-fe1b095952.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7co-1000-21b78838d8b3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:70a763529f7677b6c1e3\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CO-10000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10000\u00a0ppm\",\"sensitivity\":\"0.015 \u00b1 0.004 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CO-10000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 10000\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7co-10000-b8120f9ae5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7co-10000-9d6da9341659.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ae252cfb29652e12a6ce\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CO-2000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000\u00a0ppm\",\"sensitivity\":\"0.08 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CO-2000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 2000\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7co-2000-da4c455645.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7co-2000-cc0b7ea2ce71.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4c856831327f5f1e07c7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7CO-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0ppm\",\"sensitivity\":\"0.4 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7CO-50 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 50\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7co-50-3b56cf47dc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7co-50-1973abe52a27.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:6f86af24a8b5bb7d0402\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"CO-1000\",\"seriesKey\":\"semeatech:item-bda9deb8\",\"series\":{\"en\":\"Consumer Sensors\",\"zh\":\"\u6c11\u7528\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.04 \u00b1 0.01\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a030\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.16 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"> 7 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech CO-1000 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 1000 ppm. It belongs to the Consumer Sensors family.\",\"zh\":\"\u672c\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u5ba4\u5185\u9700\u8981\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/co-1000-50ae0116d3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-co-1000-a2beb163a423.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:90fe2bed4f53fdcda36e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"CO-1000C\",\"seriesKey\":\"semeatech:item-bda9deb8\",\"series\":{\"en\":\"Consumer Sensors\",\"zh\":\"\u6c11\u7528\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.04 \u00b1 0.01 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.16 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"> 7 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech CO-1000C uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 1000 ppm. It belongs to the Consumer Sensors family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\u3002\u5b83\u5df2\u901a\u8fc7UL 2075\u8ba4\u8bc1\uff0c\u7b26\u5408\u4f4f\u5b85\u548c\u5546\u7528\u6c14\u4f53\u68c0\u6d4b\u8bbe\u5907\u7684\u8981\u6c42\uff0c\u53ef\u786e\u4fdd\u5b89\u5168\u3001\u53ef\u9760\u4e14\u51c6\u786e\u7684\u8fd0\u884c\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/co-1000c-199e5bf33b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-co-1000c-0cfcdf09403c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ef1d869547b048e2318f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"CO-500\",\"seriesKey\":\"semeatech:item-bda9deb8\",\"series\":{\"en\":\"Consumer Sensors\",\"zh\":\"\u6c11\u7528\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.050 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a030\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.15 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"> 7 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech CO-500 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 500 ppm. It belongs to the Consumer Sensors family.\",\"zh\":\"\u672c\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u5ba4\u5185\u9700\u8981\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/co-500-88490753b1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-co-500-718c145709ef.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f45d06b4f9d7842e2060\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E3-CO-50\",\"seriesKey\":\"semeatech:3-076a68d5\",\"series\":{\"en\":\"Environmental Monitoring - 3-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-3\u7535\u6781\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.45 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a060 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"20 ppb\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E3-CO-50 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 50 ppm. It belongs to the Environmental Monitoring - 3-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u73af\u5883\u7ea7\u4e00\u6c27\u5316\u78b3\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e3-co-50-b90ce93254.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e3-co-50-04deda34a114.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7fa53d5bc1b9e5063635\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-CO-10\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.3\u00a0\u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a035\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"15 ppb\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-CO-10 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 10 ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\u8be5\u4ea7\u54c1\u7b26\u5408 CCEP\u65b0\u56fd\u68072021\u7248\u4e2d\u89c4\u5b9a\u7684\u6027\u80fd\u8981\u6c42\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-co-10-339c898d8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-co-10-1cb478721288.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a24a6aa41ebfaf6541aa\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-CO-20\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.3\u00a0\u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a035\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"15 ppb\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-CO-20 uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 20 ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\u8be5\u4ea7\u54c1\u7b26\u5408CCEP\u65b0\u56fd\u68072021\u7248\u4e2d\u89c4\u5b9a\u7684\u6027\u80fd\u8981\u6c42\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-co-20-5677732470.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-co-20-14e3298c88ae.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5724ba9b746597a3fe48\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini CO-1000S\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.045 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"<\u00a00.18 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini CO-1000S uses electrochemical sensing for Carbon Monoxide, with a measuring range of 0 ~ 1000 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-co-1000s-4d3ba22d08.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-co-1000s-657152420a8a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2ed50320fb7eca68d169\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO2-5%\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR &#038; LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"0 ~ 50000 (\u53ef\u5b9a\u5236)\\tppm\",\"sensitivity\":\"\",\"responseTime\":\"< 30\\t\u79d2\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"0% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"6 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO2-5% uses ndir infrared sensing for Carbon Dioxide, with a measuring range of 0 ~ 50000 (\u53ef\u5b9a\u5236)\\tppm. It belongs to the NDIR &#038; LEL family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co2-5-29f71bead2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co2-5-675b88f59be6.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:1bb064577b50227b5768\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4CO2-5000\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR &#038; LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"0 ~ 5000 (\u53ef\u5b9a\u5236)\\tppm\",\"sensitivity\":\"\",\"responseTime\":\"< 30\\t\u79d2\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"0% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"6 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4CO2-5000 uses ndir infrared sensing for Carbon Dioxide, with a measuring range of 0 ~ 5000 (\u53ef\u5b9a\u5236)\\tppm. It belongs to the NDIR &#038; LEL family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4co2-5000-b413af449c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4co2-5000-a556971b63b4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3966c64e6140a36b034c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"CO2-IRM203\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR &#038; LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"10000 (\u53ef\u5b9a\u5236\u5927\u91cf\u7a0b)\\tppm\",\"sensitivity\":\"\",\"responseTime\":\"90\\t\u79d2\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"0% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"\"},\"description\":{\"en\":\"SemeaTech CO2-IRM203 uses ndir infrared sensing for Carbon Dioxide, with a measuring range of 10000 (\u53ef\u5b9a\u5236\u5927\u91cf\u7a0b)\\tppm. It belongs to the NDIR &#038; LEL family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/co2-irm203-ed0a1a422a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-co2-irm203-4ec600a936d3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c8267862090f6c0da184\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"CO2-IRM300\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR &#038; LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"0 ~ 50000 (\u53ef\u5b9a\u5236)\\tppm\",\"sensitivity\":\"\",\"responseTime\":\"\u6269\u6563: 60\\t\u79d2\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"0% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"\"},\"description\":{\"en\":\"SemeaTech CO2-IRM300 uses ndir infrared sensing for Carbon Dioxide, with a measuring range of 0 ~ 50000 (\u53ef\u5b9a\u5236)\\tppm. It belongs to the NDIR &#038; LEL family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/co2-irm300-0e9d129153.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-co2-irm300-cae704233578.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:22e5503e7439b2af9d5a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"CO2-PCL0A\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR &#038; LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"0 ~ 5000 (\u53ef\u5b9a\u5236)\\tppm\",\"sensitivity\":\"\",\"responseTime\":\"< 2\\t\u5206\u949f\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"0% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"\"},\"description\":{\"en\":\"SemeaTech CO2-PCL0A uses ndir infrared sensing for Carbon Dioxide, with a measuring range of 0 ~ 5000 (\u53ef\u5b9a\u5236)\\tppm. It belongs to the NDIR &#038; LEL family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/co2-pcl0a-5deea53e57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-co2-pcl0a-cc15f340332c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:8096e2b9aef150afe980\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"CO2-ZM 200D\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR &#038; LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"400 ~ 4000 (\u53ef\u5b9a\u5236\u6700\u5927\u91cf\u7a0b10000)\\tppm\",\"sensitivity\":\"\",\"responseTime\":\"< 2\\t\u5206\u949f\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"0% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"\"},\"description\":{\"en\":\"SemeaTech CO2-ZM 200D uses ndir infrared sensing for Carbon Dioxide, with a measuring range of 400 ~ 4000 (\u53ef\u5b9a\u5236\u6700\u5927\u91cf\u7a0b10000)\\tppm. It belongs to the NDIR &#038; LEL family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/co2-zm-200d-7bfa553282.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-co2-zm-200d-96626d610044.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:1cbfa11e06454d1e228f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4COCL2-1\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"COCL2\",\"gasName\":{\"en\":\"Phosgene\",\"zh\":\"\u5149\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1\u00a0ppm\",\"sensitivity\":\"-0.35 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4COCL2-1 uses electrochemical sensing for Phosgene, with a measuring range of 0 ~ 1\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u5149\u6c14\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u5149\u6c14\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4cocl2-1-cc886f70e3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4cocl2-1-098f9eca4c99.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:89a02347e921e6d0589a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4COCL2-3\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"COCL2\",\"gasName\":{\"en\":\"Phosgene\",\"zh\":\"\u5149\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 3\u00a0ppm\",\"sensitivity\":\"-0.225 \u00b1 0.075 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4COCL2-3 uses electrochemical sensing for Phosgene, with a measuring range of 0 ~ 3\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u5149\u6c14\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u5149\u6c14\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4cocl2-3-8ed8c5c269.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4cocl2-3-902ddbfe4959.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:77de8cad95fdeb2823db\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4ETO-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10\u00a0ppm\",\"sensitivity\":\"1.9 \u00b1 0.8 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4ETO-10 uses electrochemical sensing for Ethylene Oxide, with a measuring range of 0 ~ 10\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u73af\u6c27\u4e59\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u73af\u6c27\u4e59\u70f7\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4eto-10-6737376fb6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4eto-10-05bc9923cfa9.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a07e989cf89a151c7492\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4ETO-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.250 \u00b1 0.125 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4ETO-100 uses electrochemical sensing for Ethylene Oxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u73af\u6c27\u4e59\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u73af\u6c27\u4e59\u70f7\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4eto-100-ae5188b366.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4eto-100-8e4ce53bc6e3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:1141916ab83532a699e0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4ETO-500\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500\u00a0ppm\",\"sensitivity\":\"0.058 \u00b1 0.033 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4ETO-500 uses electrochemical sensing for Ethylene Oxide, with a measuring range of 0 ~ 500\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u73af\u6c27\u4e59\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u73af\u6c27\u4e59\u70f7\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4eto-500-865a80693a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4eto-500-1565e3f2c1d5.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:74c4e73ee6533b3b7ae5\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7ETO-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.250 \u00b1 0.125 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7ETO-100 uses electrochemical sensing for Ethylene Oxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u73af\u6c27\u4e59\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u73af\u6c27\u4e59\u70f7\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7eto-100-0cc7a1ff0d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7eto-100-ff3b06900b3e.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:9234dd22252c12b19351\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7ETO-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"2.25 \u00b1 0.65 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7ETO-20 uses electrochemical sensing for Ethylene Oxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u73af\u6c27\u4e59\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u73af\u6c27\u4e59\u70f7\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7eto-20-2055f394ca.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7eto-20-2699a2256ed7.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:39ca9a6db0d0ee6290b3\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini ETO-100\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.13 \u00b1 0.06 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini ETO-100 uses electrochemical sensing for Ethylene Oxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u73af\u6c27\u4e59\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177 \u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-eto-100-837bc4d3cc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-eto-100-897ead034e70.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e09d5cd2b70145fd418c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4GeH4-1\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"GEH4\",\"gasName\":{\"en\":\"Germane\",\"zh\":\"\u9517\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1\u00a0ppm\",\"sensitivity\":\"3.0 \u00b1 0.6\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 45\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.005\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4GeH4-1 uses electrochemical sensing for Germane, with a measuring range of 0 ~ 1\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u9517\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u9517\u70f7\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4geh4-1-c52484135e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4geh4-1-acb37beceeb9.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:175d07174f70358a3fae\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2-1000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000\u00a0ppm\",\"sensitivity\":\"0.02 \u00b1 0.01\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2-1000 uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 1000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2-1000-6d2f1666d2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2-1000-661217e04818.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:8fc14f84679f3969d06b\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2-1000A\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000\u00a0ppm\",\"sensitivity\":\"0.02 \u00b1 0.01\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2-1000A uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 1000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u80fd\u591f\u6d88\u9664\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u5e72\u6270\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2-1000a-0e07ea99a0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2-1000a-58203356a4a4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:92d44106356693bf4664\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000\u00a0ppm\",\"sensitivity\":\"0.018 \u00b1 0.010 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2-2000 uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 2000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2-2000-e8d914360a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2-2000-52f56734a548.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:78cb41d8554a80c97c54\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2-2000A\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000\u00a0ppm\",\"sensitivity\":\"0.018 \u00b1 0.010 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"20% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2-2000A uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 2000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u80fd\u591f\u6d88\u9664\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u5e72\u6270\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2-2000a-5cd773e10a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2-2000a-d459c3573517.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a44dc27ff964dc690eca\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2-40000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 40000\u00a0ppm\",\"sensitivity\":\"0.010 \u00b1 0.003 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"50 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2-40000 uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 40000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2-40000-0135ef707c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2-40000-49b3c1e619d2.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2728cb5a92ea7dfe67a1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2-40000A\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 40000\u00a0ppm\",\"sensitivity\":\"0.010 \u00b1 0.003 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u00b0C ~ 45\u00b0C*\",\"humidity\":\"20% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2-40000A uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 40000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2-40000a-49ca05c843.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2-40000a-5cea5744abea.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c63b54fa77af07f53f42\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2-1000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.02 \u00b1 0.01 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a090 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2-1000 uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 1000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2-1000-f241b9bc59.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2-1000-6c25e20fd373.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:798e9dda8714d69aebbb\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2-10000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10000 ppm\",\"sensitivity\":\"0.006 \u00b1 0.003 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a0110 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2-10000 uses electrochemical sensing for Hydrogen, with a measuring range of 0 ~ 10000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c22\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c22\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2-10000-d8a55f94ac.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2-10000-e4faddc95a38.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4b497d04c4f21b24373e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2O2-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.5 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2O2-10 uses electrochemical sensing for Hydrogen Peroxide, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u7528\u4e8e\u6d4b\u91cf\u8fc7\u6c27\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u8fc7\u6c27\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2o2-10-106ecd556f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2o2-10-ecf4f4f64a97.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:821f3af97670ed536aa7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2O2-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.40 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.015 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2O2-100 uses electrochemical sensing for Hydrogen Peroxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u7528\u4e8e\u6d4b\u91cf\u8fc7\u6c27\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u8fc7\u6c27\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2o2-100-c8d8dae576.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2o2-100-6fe5d1dd35fd.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:eb1bebd90467790e5a11\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2O2-10\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.7 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.005\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2O2-10 uses electrochemical sensing for Hydrogen Peroxide, with a measuring range of 0 ~ 10 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u8fc7\u6c27\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u8fc7\u6c27\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2o2-10-e7648913b8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2o2-10-cef8b3152749.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:90050244c80ab4eb686c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2O2-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.50 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2O2-100 uses electrochemical sensing for Hydrogen Peroxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u8fc7\u6c27\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u8fc7\u6c27\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2o2-100-f8ff840779.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2o2-100-fcced5ac994f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:87c0bf7ad2e901f07aad\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3H2S-1000\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3H2S-1000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 1000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3h2s-1000-05579fa9b5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3h2s-1000-c0671286a115.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ae5fe7729f139b449620\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3H2S-1000CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3H2S-1000CT uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 1000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u786b\u5316\u6c22\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u786b\u5316\u6c22\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3h2s-1000ct-effbb5bb73.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3h2s-1000ct-446dbc008df1.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d8e7261f1694b0a23d69\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10\u00a0ppm\",\"sensitivity\":\"1.40 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-10 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 10\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-10-cf4f74a888.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-10-fcc40c271a3f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a4dcd55c1f838f68b1c9\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.8\u00a0\u00b1 0.2\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-100 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e13\u4e3a\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u6d53\u5ea6\u7684\u5355\u4e00\u6c14\u4f53\u76d1\u6d4b\u4eea\u800c\u8bbe\u8ba1\u3002\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u66ff\u6362\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u786b\u5316\u6c22\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-100-d83a061420.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-100-ab79480bcb18.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b1559f1835a129e435cf\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-1000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000\u00a0ppm\",\"sensitivity\":\"0.105 \u00b1 0.055\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-1000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 1000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-1000-45862d5d9b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-1000-470fb82f28c6.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e9762952b79360be92cb\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-100HT\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.15 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u00b0C ~ 65\u00b0C\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"1 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-100HT uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u91c7\u7528\u4e86\u65b0\u7684\u7535\u5316\u5b66\u6280\u672f\uff0c\u7528\u4e8e\u9ad8\u6e29\u73af\u5883\u4e0b\u786b\u5316\u6c22\u6d53\u5ea6\u7684 \u6d4b\u91cf\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-100ht-1dd77197f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-100ht-a9874f8b0a18.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e31d1060e19bf86b5667\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-100S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.60\u00a0\u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-100S uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\u3002\u5b83\u53d7\u4e00\u6c27\u5316\u78b3\u6c14\u4f53\u5e72\u6270\u5c0f\uff0c\u662f\u9700\u8981\u6d4b\u91cf\u786b\u5316\u6c22\u548c\u4e00\u6c27\u5316\u78b3\u591a\u6c14\u4f53\u76d1\u6d4b\u4eea\u7684\u7406\u60f3\u9009\u62e9\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-100s-2ea824ddd5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-100s-7daf40cd3380.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:44ca489f850ccc72efd7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"1.30 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.08 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-20 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-20-5f3f718000.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-20-886126618557.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4fa1095abc8fa209282f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000\u00a0ppm\",\"sensitivity\":\"0.09 \u00b1 0.04 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-2000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 2000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-2000-ceb6371232.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-2000-bf0e01d1dd55.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:29e6ab2ac1cb3479ffd1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0ppm\",\"sensitivity\":\"1.20 \u00b1 0.25 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.08 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-50 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 50\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-50-80a56e03e4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-50-30359ef47a64.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:fa36f824f428e03863ab\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-500\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500\u00a0ppm\",\"sensitivity\":\"0.65 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-500 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 500\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-500-63c0485d81.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-500-786aaf8023f4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7950ca820908f09744bb\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4H2S-5000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5000\u00a0ppm\",\"sensitivity\":\"0.08\u00a0\u00b1 0.02\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4H2S-5000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 5000\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4h2s-5000-2e66146145.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4h2s-5000-5395a1adc920.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4444dd38a7f5c6d3c6fd\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMH2S-50\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0ppm\",\"sensitivity\":\"1.25 \u00b1 0.25 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01\u00a0ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMH2S-50 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 50\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u786b\u5316\u6c22\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smh2s-50-e3947542a6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smh2s-50-0001ee3c0acc.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5607e929eb2d0e517ef9\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.45 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-100 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-100-b6cc01768d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-100-dc370c1a4593.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:37a039623332d08b22e1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-1000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.115\u00a0\u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 50\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-1000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 1000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-1000-06d1836f88.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-1000-10d62f67e342.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b98730d90151bd165c34\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-10000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10000 ppm\",\"sensitivity\":\"0.025\u00a0\u00b1 0.006 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-10000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 10000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-10000-54b2717f8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-10000-45e52315a584.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:dca73db0be8f3dd650fd\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-100HT\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.15 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.015 ppm\",\"temperature\":\"-20\u2103 ~ 65\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"1\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-100HT uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u91c7\u7528\u4e86\u65b0\u7684\u7535\u5316\u5b66\u6280\u672f\uff0c\u7528\u4e8e\u9ad8\u6e29\u73af\u5883\u4e0b\u786b\u5316\u6c22\u6d53\u5ea6\u7684\u6d4b\u91cf\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-100ht-0bb365ce01.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-100ht-0cf977aa18b9.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a62915c1dc9d3c286988\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"2.5 \u00b1 0.5\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-20 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-20-6411fc39c9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-20-ae67ebbef96e.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4f2867d35134700a9941\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-200\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200\u00a0ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-200 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 200\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-200-9d7840ae3b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-200-6c24624e024a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:07feb7fa4276d35ca2df\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-2000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.0975\u00a0\u00b1 0.0175 \u03bcA\/ppm\",\"responseTime\":\"\u2264 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-2000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-2000-db48ce1a98.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-2000-4a9d0512e637.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e973fafbe5c7d0f24ff0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0ppm\",\"sensitivity\":\"1.7 \u00b1 0.3 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-50 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 50\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-50-64a1203e4a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-50-eaf396241bb7.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b577e21fb7f0002cb6c0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-500\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500\u00a0ppm\",\"sensitivity\":\"0.30 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-500 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 500\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-500-a8a13a8f9c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-500-b21dc03eaa12.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f28405a3850aa1e0429c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7H2S-5000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5000 ppm\",\"sensitivity\":\"0.040\u00a0\u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7H2S-5000 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 5000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u786b\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7h2s-5000-b4243537c8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7h2s-5000-24a0f31237ed.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:354c8f6ba7fc1e0d9287\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-H2S-10\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"1.5 \u00b1 0.5 \u03bcA\/ppm\",\"responseTime\":\"\u2264\u00a090\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppb\",\"temperature\":\"-30\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-H2S-10 uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 10 ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-h2s-10-3abc350345.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-h2s-10-9a24c1878117.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3b6e4dfe38757995e9e1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini H2S-100S\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.14 \u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini H2S-100S uses electrochemical sensing for Hydrogen Sulfide, with a measuring range of 0 ~ 100 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u786b\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-h2s-100s-96c1b2dcf5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-h2s-100s-eeb84821160f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:96f055d5ee72e1f5ce6e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HBr-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HBR\",\"gasName\":{\"en\":\"Hydrogen Bromide\",\"zh\":\"\u6eb4\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.16 \u00b1 0.06 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.6\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HBr-20 uses electrochemical sensing for Hydrogen Bromide, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6eb4\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6eb4\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hbr-20-5d2939231c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hbr-20-15a87e16f2dc.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a5d0d8f12b1f517d343a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCL-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.2 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCL-100 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcl-100-e8021b2924.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcl-100-701bc1439a74.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0b9353846ae4c7a16070\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCL-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.35 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCL-20 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcl-20-e161ee0231.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcl-20-729d8cccad04.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:194f5582116ce4f3886b\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCL-200\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"0.08 \u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCL-200 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 200 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcl-200-ac182de9fa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcl-200-06740063008f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:736489a112f946cf1a8a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCL-20U\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.35 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.06\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCL-20U uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u6c2f\u5316\u6c22\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcl-20u-8a0b5d093a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcl-20u-c0dc8310e6b3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d8ebc3c54738e6d2beb0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCL-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.3 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.4 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCL-50 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c2f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcl-50-405f2b5018.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcl-50-bc6925b427de.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:908c5aca4b53ba4f174f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCL-50U\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.3 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCL-50U uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u6c2f\u5316\u6c22\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcl-50u-a7f3b3b4e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcl-50u-17b335be63f4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d0a5b0f2b95ff48a02e9\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMHCL-10\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10\u00a0ppm\",\"sensitivity\":\"-0.55 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 140\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01\u00a0ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMHCL-10 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 10\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u6c2f\u5316\u6c22\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smhcl-10-3187bb2a28.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smhcl-10-1a028ff5f5b3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:31fb9a0c86844cf8d061\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HCL-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.3\u00a0\u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HCL-100 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c2f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hcl-100-c47dc5a069.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hcl-100-000c7fa12052.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:99ae9e9b0dd180dddcfc\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HCL-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.55 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HCL-20 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 20 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c2f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hcl-20-4291e04c68.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hcl-20-027c04ef668c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:1e734e49ceca20dadd22\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HCL-20U\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.35 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.04 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HCL-20U uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 20 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u6c2f\u5316\u6c22\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hcl-20u-85fa1143a7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hcl-20u-60d047255b78.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7f034f270279d2f6ed22\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HCL-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.45 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HCL-50 uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c2f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hcl-50-05e76b542c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hcl-50-497037fb3b8a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c3bf8787be72bb6357c6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HCL-50U\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.3 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HCL-50U uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u6c2f\u5316\u6c22\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hcl-50u-6c77a4fe1b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hcl-50u-9e8e8091c094.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0bd06d6f9d75f08f114f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini HCl-50U\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0ppm\",\"sensitivity\":\"0.2 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini HCl-50U uses electrochemical sensing for Hydrogen Chloride, with a measuring range of 0 ~ 50\u00a0ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c2f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-hcl-50u-2dc14f96c1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-hcl-50u-f2eec6788f9c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c846e5f5c785f80547fa\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCN-10S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 105 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCN-10S uses electrochemical sensing for Hydrogen Cyanide, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c30\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c30\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcn-10s-d0ed960ecb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcn-10s-0e2397cd932b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2c16d12ac8795f86fe09\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HCN-50S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.065 \u00b1 0.020 \u03bcA\/ppm\",\"responseTime\":\"\u2264 105 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HCN-50S uses electrochemical sensing for Hydrogen Cyanide, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c30\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c30\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hcn-50s-7afeca05ee.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hcn-50s-81eb9744348b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c36ddd035d1813e6e6e0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HCN-50S\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.055 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 105 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HCN-50S uses electrochemical sensing for Hydrogen Cyanide, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c30\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c30\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hcn-50s-45b1bc2527.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hcn-50s-dbffdef59049.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:52a9a244b200d001be32\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini HCN-10S\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10\u00a0ppm\",\"sensitivity\":\"0.06 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.03\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini HCN-10S uses electrochemical sensing for Hydrogen Cyanide, with a measuring range of 0 ~ 10\u00a0ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c30\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-hcn-10s-1961267a77.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-hcn-10s-16428c50187b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:88545e0014f875e6bb79\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HF-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"-0.3 \u00b1 0.1\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HF-10 uses electrochemical sensing for Hydrogen Fluoride, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c1f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c1f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hf-10-f7c27498e6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hf-10-13d7e1957a34.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a4a1411803b5deb2874c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4HF-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"-0.15 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 130 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4HF-100 uses electrochemical sensing for Hydrogen Fluoride, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c1f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c1f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4hf-100-a3e2c21f43.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4hf-100-c547707f3cf3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c947e565ee2641bb8f78\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMHF-5\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"-0.5 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 140 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.015 ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMHF-5 uses electrochemical sensing for Hydrogen Fluoride, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u6c1f\u5316\u6c22\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u6c1f\u5316\u6c22\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smhf-5-795f957be4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smhf-5-106449e110d6.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e80acfbbf39c499b5565\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HF-10\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"-0.4\u00a0\u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HF-10 uses electrochemical sensing for Hydrogen Fluoride, with a measuring range of 0 ~ 10 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c1f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c1f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hf-10-836ef70d82.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hf-10-ace337a2cb59.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:bbd9c85ee8d039af5827\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7HF-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"-0.3 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7HF-50 uses electrochemical sensing for Hydrogen Fluoride, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c1f\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c1f\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7hf-50-d95ce70785.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7hf-50-e2f228ecee04.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:59624be77a02b78ef5db\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"TPGS2\u70ed\u7535\u5806 \u82af\u7247\u5c3a\u5bf8\uff1a1.75 x 1.75 mm\u00b2 \u6709\u6548\u9762\u79ef\uff1a0.9 x 0.9 mm\u00b2 \u54cd\u5e94\u7387\uff1a36 V\/W \u63a2\u6d4b\u7387\uff1a1E8 cm\u00b7Hz1\/2\/W \u70ed\u7535\u5806\u7535\u963b\uff1a75 k\u03a9 (\u5178\u578b) \u5de5\u4f5c\u6e29\u5ea6\uff1a-40 ~ 120\u2103 \u50a8\u5b58\u6e29\u5ea6\uff1a-40 ~ 120\u2103\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR & LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"IR_DETECTOR\",\"gasName\":{\"en\":\"Infrared Detector Element\",\"zh\":\"\u7ea2\u5916\u63a2\u6d4b\u5143\u4ef6\"},\"tech\":\"THERMOPILE\",\"techName\":{\"en\":\"Infrared Thermopile\",\"zh\":\"\u7ea2\u5916\u70ed\u7535\u5806\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"description\":{\"en\":\"SemeaTech TPGS2\u70ed\u7535\u5806 \u82af\u7247\u5c3a\u5bf8\uff1a1.75 x 1.75 mm\u00b2 \u6709\u6548\u9762\u79ef\uff1a0.9 x 0.9 mm\u00b2 \u54cd\u5e94\u7387\uff1a36 V\/W \u63a2\u6d4b\u7387\uff1a1E8 cm\u00b7Hz1\/2\/W \u70ed\u7535\u5806\u7535\u963b\uff1a75 k\u03a9 (\u5178\u578b) \u5de5\u4f5c\u6e29\u5ea6\uff1a-40 ~ 120\u2103 \u50a8\u5b58\u6e29\u5ea6\uff1a-40 ~ 120\u2103 uses infrared thermopile sensing for Infrared Detector Element. It belongs to the NDIR & LEL family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/tpgs2-1-75-x-1-75-mm2-0-9-x-0-9-mm2-36-v-w-1e8-cm-hz1-2-w-75-k-40-120-c-40-120-c-1672543666.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-tpgs2-1-75-x-1-75-mm2-0-9-x-0-9-mm2-36-v-w-1e8-cm-hz1-2-w-75-k-40-120-c-40-120-c-2ee4aefd0240.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5bb31bd38e1be0b37258\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini LEL-2.5V\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0 ~ 100% LEL\",\"sensitivity\":\"43 \u00b1 8 mV\/%CH4\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1% LEL\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"\u2264 95%RH (25\u00b0C)\",\"lifetime\":\"> 3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini LEL-2.5V uses catalytic combustion sensing for Combustible Gas, with a measuring range of 0 ~ 100% LEL. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u53ef\u71c3\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed \u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u5f0f\u548c\u7d27\u51d1\u5f0f\u4eea\u5668\u4eea\u8868\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-lel-2-5v-877238bcf3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-lel-2-5v-478b16d1676b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:8a036b2860be8201d42d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4LEL-3.0V\",\"seriesKey\":\"semeatech:ndir-lel-2354ce12\",\"series\":{\"en\":\"NDIR & LEL\",\"zh\":\"NDIR\u548cLEL\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0 ~ 100% LEL\",\"sensitivity\":\"22 \u00b1 7 mV\/%CH4\",\"responseTime\":\"< 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-30\u2103 ~ 50\u2103\",\"humidity\":\"\u2264\u00a098%\u00a0(25\u2103)\",\"lifetime\":\"> 2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4LEL-3.0V uses catalytic combustion sensing for Combustible Gas, with a measuring range of 0 ~ 100% LEL. It belongs to the NDIR & LEL family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u53ef\u71c3\u6027\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4lel-3-0v-0b83235dda.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4lel-3-0v-8e4d9a7c7802.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0c70e2eac29ee68a2ee6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4N2H4-1\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"N2H4\",\"gasName\":{\"en\":\"Hydrazine\",\"zh\":\"\u80bc\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1\u00a0ppm\",\"sensitivity\":\"5.0 \u00b1 1.5 \u03bcA\/ppm\",\"responseTime\":\"\u2264 100\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.002\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4N2H4-1 uses electrochemical sensing for Hydrazine, with a measuring range of 0 ~ 1\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u8054\u6c28\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u8054\u6c28\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4n2h4-1-0e283092ed.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4n2h4-1-7a5f95b703e6.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:cb978c146debc64d9da7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.135 \u00b1 0.035 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-100 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-100-4d99d5b4f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-100-1cb03a716e2f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:87dbf9921851e90b80bc\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-1000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.025 \u00b1 0.008 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-1000 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-1000-eb8ea0de42.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-1000-d96335008d01.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:bb696d917b68041faac6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-1000L\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.025 \u00b1 0.008 \u03bcA\/ppm\",\"responseTime\":\"\u2264 110 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-1000L uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u4e0e\u4f20\u7edf\u7684\u6d88\u8017\u578b\u6c28\u6c14\u4f20\u611f\u5668\u4e0d\u540c\uff0c\u8fd9\u662f\u4e00\u6b3e\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u975e\u6d88\u8017\u578b\u957f\u5bff\u547d\u6c28\u6c14\u4f20\u611f\u5668\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u6c28\u6c14\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-1000l-80c4bb563b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-1000l-bb2784a4503f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:68dcd37b1ab6f91991b2\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-1000S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.025 \u00b1 0.008 \u03bcA\/ppm\",\"responseTime\":\"\u2264 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-1000S uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-1000s-c507290c42.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-1000s-f754dd663da1.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5746d4a31f4b9729fe12\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-100L\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.135 \u00b1 0.035 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-100L uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u4e0e\u4f20\u7edf\u7684\u6d88\u8017\u578b\u6c28\u6c14\u4f20\u611f\u5668\u4e0d\u540c\uff0c\u8fd9\u662f\u4e00\u6b3e\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u975e\u6d88\u8017\u578b\u957f\u5bff\u547d\u6c28\u6c14\u4f20\u611f\u5668\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u6c28\u6c14\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-100l-62e1892e71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-100l-e35792dcdf15.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:168730568d943ea3a9c1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-100S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.135 \u00b1 0.035 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-100S uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-100s-0953cf02c0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-100s-88de69eaa86d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:01ef12e78c01cdd8012f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.150 \u00b1 0.035 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-20 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-20-32d86be0a2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-20-d85cff49072c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5dbbd832ec5bd128b593\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.015 \u00b1 0.005 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-2000 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-2000-e8cf4b76a6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-2000-79ea6c1c022c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:21276fe51590e08c4676\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-2000L\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.008 \u00b1 0.004 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-40\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-2000L uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u4e0e\u4f20\u7edf\u7684\u6d88\u8017\u578b\u6c28\u6c14\u4f20\u611f\u5668\u4e0d\u540c\uff0c\u8fd9\u662f\u4e00\u6b3e\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u975e\u6d88\u8017\u578b\u957f\u5bff\u547d\u6c28\u6c14\u4f20\u611f\u5668\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u6c28\u6c14\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-2000l-4a6d6824cc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-2000l-02d0b98e1cae.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:eced2ccfb7207a98a80a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-200L\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"0.090 \u00b1 0.018 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-200L uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 200 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u4e0e\u4f20\u7edf\u7684\u6d88\u8017\u578b\u6c28\u6c14\u4f20\u611f\u5668\u4e0d\u540c\uff0c\u8fd9\u662f\u4e00\u6b3e\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u975e\u6d88\u8017\u578b\u957f\u5bff\u547d\u6c28\u6c14\u4f20\u611f\u5668\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u6c28\u6c14\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-200l-2ebefa73cd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-200l-6806b55776fe.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:36dbde1eca0b2f1694ab\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-500\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.035 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-500 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 500 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-500-3c1fa043b8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-500-1bea2ec4d263.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:009eb07b34dbc1cee285\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-5000L\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5000 ppm\",\"sensitivity\":\"0.006 \u00b1 0.003\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-40\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-5000L uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 5000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u4e0e\u4f20\u7edf\u7684\u6d88\u8017\u578b\u6c28\u6c14\u4f20\u611f\u5668\u4e0d\u540c\uff0c\u8fd9\u662f\u4e00\u6b3e\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u975e\u6d88\u8017\u578b\u957f\u5bff\u547d\u6c28\u6c14\u4f20\u611f\u5668\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u6c28\u6c14\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-5000l-8ab7c5b2e9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-5000l-897d21fb8d72.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e2315a2d3a266951b131\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-500L\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.035 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 85 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-500L uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 500 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u4e0e\u4f20\u7edf\u7684\u6d88\u8017\u578b\u6c28\u6c14\u4f20\u611f\u5668\u4e0d\u540c\uff0c\u8fd9\u662f\u4e00\u6b3e\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u975e\u6d88\u8017\u578b\u957f\u5bff\u547d\u6c28\u6c14\u4f20\u611f\u5668\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u6c28\u6c14\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-500l-8304b15de3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-500l-87b0122c60ad.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:871c4728a4ce2e391caf\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NH3-500S\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.035 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NH3-500S uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 500 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4nh3-500s-2ee4f8226f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4nh3-500s-2a356589d56a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3b35e77092ac74cc79d1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMNH3-100\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.035 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1\u00a0ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMNH3-100 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u6c28\u6c14\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smnh3-100-0f0834fbd3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smnh3-100-f4b56087fcd2.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4eb2dff328b22efb2891\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.13\u00a0\u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.3 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-100 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-100-d4d8b03ee3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-100-29b660b96440.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:53c00663beac514d5f56\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-1000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.025 \u00b1 0.008 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-1000 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 1000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-1000-6a2e1a1be0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-1000-d8ff0ecfdbc1.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0fd00d45135b453d97fc\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-1000S\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.025\u00a0\u00b1 0.008 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-1000S uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 1000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-1000s-07c5bd8ff4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-1000s-3996832bc154.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:768b9655eeae46bdd148\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-100S\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.13\u00a0\u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.3 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-100S uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-100s-75d7618e1f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-100s-70ad358ea57a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:966051a76ebd0a469d7a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-200\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"0.090 \u00b1 0.018 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-200 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 200 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-200-85bc50cdbe.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-200-28993011a99b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:84358533e89dd2828612\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-2000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~\u00a02000 ppm\",\"sensitivity\":\"0.008 \u00b1 0.004 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-2000 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~\u00a02000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-2000-effd93519c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-2000-3c2dc52b8064.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5e1a70232cb6722f1fed\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-200S\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"0.090 \u00b1 0.018 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-200S uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 200 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-200s-34bf4316a7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-200s-87e9d2619eab.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:dd6f82c38313baba0e90\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-50\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.15 \u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-50 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 50 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-50-b0f5ba0053.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-50-7225a8a9baa0.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:18ee5fe64aa453bc4e6d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-500\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.035 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-500 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 500 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-500-349cfd9b2b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-500-da625826bd6c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4d0a1a705ad9143547a2\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NH3-500S\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.035 \u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 55\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NH3-500S uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 500 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u6c28\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7nh3-500s-45b2897d98.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7nh3-500s-ee04566cd56d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:65d77d62117d8429632c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-NH3-10\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.20 \u00b1 0.05\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"15 ppb\",\"temperature\":\"-30\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-NH3-10 uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 10 ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-nh3-10-d99bd59bfe.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-nh3-10-304e9b8dd722.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f34a7104812a87e8bc9f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini NH3-100L\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.05 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.08 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini NH3-100L uses electrochemical sensing for Ammonia, with a measuring range of 0 ~ 100 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u662f\u7528\u4e8e\u6d4b\u91cf\u6c28\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u975e\u6d88\u8017\u578b\u957f\u5bff\u547d\u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u5f0f\u548c\u7d27\u51d1\u5f0f\u4eea\u5668\u4eea\u8868\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-nh3-100l-7e1dbce115.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-nh3-100l-0a40ccce8006.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0fca1db0127db6378ba5\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3NO-1000CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3NO-1000CT uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 1000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e00\u6c27\u5316\u6c2e\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3no-1000ct-1dcb1822fa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3no-1000ct-e9e5c94c1965.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:631c8e8727497466bc25\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3NO-2000\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3NO-2000 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3no-2000-1ec13e0b25.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3no-2000-0f036722419f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:29df0ec48ae5a9c94163\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3NO-2000CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3NO-2000CT uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e00\u6c27\u5316\u6c2e\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3no-2000ct-7e5bb618b5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3no-2000ct-3829249f17c1.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:1cff9865202ba61060ac\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3NO-500\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.20 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3NO-500 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 500 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3no-500-f5c9fc2e63.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3no-500-204a39ced4f0.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0ea4b67866ca0b811a66\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.13 \u00b1 0.06 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO-2000 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no-2000-11ac5ab507.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no-2000-eba2e2322da4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d76e3282a64a70b7c20f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO-200U\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 200\u00a0ppm\",\"sensitivity\":\"0.3 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO-200U uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 200\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no-200u-408f2f237c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no-200u-6e60c5124627.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:90d86111605c97ae965c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO-250\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 250 ppm\",\"sensitivity\":\"0.4 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO-250 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 250 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no-250-409d62ba32.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no-250-729d26270134.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d632341e1a486581cc59\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO-5\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5 ppm\",\"sensitivity\":\"1.0 \u00b1 0.4 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO-5 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 5 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no-5-3324a2e3d9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no-5-5522b3e39783.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f263351c4a903a1df84a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO-5U\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5 ppm\",\"sensitivity\":\"0.9 \u00b1 0.3 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.005 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO-5U uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 5 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no-5u-f9a70c1cca.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no-5u-bd421cddd1da.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:137da4c053aab664827f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMNO-100\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.4 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1\u00a0ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMNO-100 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smno-100-adc112b0d6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smno-100-feb97c51600c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:18541cabd659b7a05776\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.55 \u00b1 0.11 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO-100 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no-100-ac89bd755b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no-100-411ad7929d45.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:55a0c2074d4a468d558a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO-100U\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.27 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.008\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO-100U uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4 \u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no-100u-6016deac12.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no-100u-ce65cdb36863.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c32744681e0dde0ecee6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO-5\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"1.0 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 15\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO-5 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no-5-19d4d013c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no-5-2e0162a9aef0.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e9bfc51c7170f318d91d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO-5U\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"1.5 \u00b1 0.3 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.005 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO-5U uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u4e3a\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u4e0e\u5e02\u573a\u4e0a\u5176\u4ed6\u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u76f8\u6bd4\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no-5u-533460b4e3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no-5u-664a501f52ec.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b2670f7120109c583b96\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E3-NO-100\",\"seriesKey\":\"semeatech:3-076a68d5\",\"series\":{\"en\":\"Environmental Monitoring - 3-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-3\u7535\u6781\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100\u00a0ppm\",\"sensitivity\":\"0.55 \u00b1 0.11\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"200 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E3-NO-100 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 100\u00a0ppm. It belongs to the Environmental Monitoring - 3-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e00\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e3-no-100-bb4950549b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e3-no-100-21caf8da045c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:8b326a630dade14d7b84\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-NO-10\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"0.4\u00a0\u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"15 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-NO-10 uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 10 ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-no-10-738e25ced3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-no-10-9e90d78cef02.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:56727a486bf3a6ad4ab8\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-NO-10U\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"1.0 \u00b1 0.4 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-NO-10U uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 10 ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u91c7\u75287E4-NO-10\u56db\u7535\u6781\u7ed3\u6784\uff0c\u7ed3\u5408\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u521b\u65b0\u6027\u5730\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-no-10u-3b2f980c7e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-no-10u-d51ead48e184.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:658f8e9237d61370788c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini NO-50U\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.18 \u00b1 0.05 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini NO-50U uses electrochemical sensing for Nitric Oxide, with a measuring range of 0 ~ 50 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e00\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u96f6\u504f\u538b\u8bbe\u8ba1\uff0c\u6d88\u9664\u4e86\u4f20\u611f\u5668\u9884\u70ed\u65f6\u95f4\u5e76\u7b80\u5316\u6c14\u4f53\u76d1\u6d4b\u4eea\u8bbe\u8ba1\uff0c\u5177\u6709\u66f4\u7a33\u5b9a\u7684\u57fa\u7ebf\u548c\u66f4\u9ad8\u7684\u5206\u8fa8\u7387\uff1b\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\uff0c\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-no-50u-d48053f3d3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-no-50u-efe366ffd557.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:793c825bcfabb9bbbaf6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3NO2-100CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"-0.37 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3NO2-100CT uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e8c\u6c27\u5316\u6c2e\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3no2-100ct-37caddacc1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3no2-100ct-150f49c1bb40.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:77defa055d2a23dd0df9\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3NO2-500\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"-0.37 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3NO2-500 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 500 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3no2-500-0b7a05892b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3no2-500-3536ce3bbc04.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ab81c2a1b3811debc455\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3NO2-500CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"-0.37 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3NO2-500CT uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 500 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e8c\u6c27\u5316\u6c2e\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3no2-500ct-7f59123961.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3no2-500ct-3a7e0e369564.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:af29673d6d408315f86e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO2-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.60 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.008 ppm\",\"temperature\":\"-40\u00b0C ~ 50\u00b0C\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO2-20 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no2-20-382baa0840.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no2-20-43003fb5b2a5.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e129b13815e7d6acaa2e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO2-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"-0.02 \u00b1 0.01 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40\u00b0C ~ 50\u00b0C\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO2-2000 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no2-2000-3da9fa3dcc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no2-2000-44b53d8b0efb.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7de838134d593b433285\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO2-20A\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.60 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO2-20A uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u53ef\u6d88\u9664\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u5e72\u6270\uff0c\u5b83\u53ef\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no2-20a-9eef6d7514.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no2-20a-8c8c7a607325.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:29faa3fb153372c462f5\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO2-20AF\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.60 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO2-20AF uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u5185\u7f6e\u8fc7\u6ee4\u5668\uff0c\u6d88\u9664\u4e86\u4e8c\u6c27\u5316\u786b\u548c\u786b\u5316\u6c22\u6c14\u4f53\u5e72\u6270\uff0c\u53ef\u7528 \u4e8e\u66ff\u4ee3\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no2-20af-3403efd87f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no2-20af-9b01982a9e31.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a52748b607bc81b63d07\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4NO2-5AOF\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5 ppm\",\"sensitivity\":\"-0.65 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4NO2-5AOF uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 5 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u5185\u7f6e\u8fc7\u6ee4\u5668\uff0c\u53ef\u6d88\u9664\u4e8c\u6c27\u5316\u786b\u548c\u81ed\u6c27\u6c14\u4f53\u5e72\u6270\u3002\u5b83\u662f\u7a7a\u6c14\u8d28\u91cf\u76d1\u6d4b\u5e94\u7528\u7684\u7406\u60f3\u9009\u62e9\u3002\u53ef\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4no2-5aof-5bbd357ae7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4no2-5aof-75bacbc1bbc6.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5bc6d2407009e5a3484b\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO2-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"-0.45\u00a0\u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO2-100 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no2-100-bfaf7711c5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no2-100-21be8110fb9a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:1e07b9eaa15a0a98a716\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO2-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.8 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.005 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO2-20 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no2-20-a5dd0b949b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no2-20-d3a360a197e2.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b7405b3fc595ce7bfb13\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO2-500\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"-0.35\u00a0\u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.015\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO2-500 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 500 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no2-500-6ec6454135.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no2-500-7fed678b32e0.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3089d481b124023346c2\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7NO2-5AOF\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"-0.65 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7NO2-5AOF uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u5185\u7f6e\u8fc7\u6ee4\u5668\uff0c\u53ef\u6d88\u9664\u4e8c\u6c27\u5316\u786b\u548c\u81ed\u6c27\u6c14\u4f53\u5e72\u6270\u3002\u5b83\u662f\u7a7a\u6c14\u8d28\u91cf\u76d1\u6d4b\u5e94\u7528\u7684\u7406\u60f3\u9009\u62e9\u3002\u53ef\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7no2-5aof-60b52b2df2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7no2-5aof-7508dcb91b48.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:468ed2feeddfd7eb69fe\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E3-NO2-5\",\"seriesKey\":\"semeatech:3-076a68d5\",\"series\":{\"en\":\"Environmental Monitoring - 3-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-3\u7535\u6781\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"-0.65 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E3-NO2-5 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the Environmental Monitoring - 3-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u73af\u5883\u7ea7\u4e8c\u6c27\u5316\u6c2e\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e3-no2-5-37a7d5c7f4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e3-no2-5-af4a340e0d36.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a6a57ef5803d34f3ba2f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-NO2-5\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"-0.50 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-NO2-5 uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\u8be5\u4ea7\u54c1\u7b26\u5408 CCEP\u65b0\u56fd\u68072021\u7248\u4e2d\u89c4\u5b9a\u7684\u6027\u80fd\u8981\u6c42\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-no2-5-e0bc32b584.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-no2-5-0d3496263404.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:599462d76e2673a472d1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini NO2-20A\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-0.23 \u00b1 0.12 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini NO2-20A uses electrochemical sensing for Nitrogen Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u6c2e\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-no2-20a-2ef4665768.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-no2-20a-bb53b32e40df.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:cf8afd00efbcf208388e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4O2-LF-100%\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100% vol\u6c27\",\"sensitivity\":\"-40 \u00b1 10 \u03bcA (\u7a7a\u6c14\u4e2d)\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05% vol\u6c27\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4O2-LF-100% uses electrochemical sensing for Oxygen, with a measuring range of 0 ~ 100% vol\u6c27. It belongs to the 4 Series family.\",\"zh\":\"\u8be5\u65e0\u94c5\u6c27\u6c14\u4f20\u611f\u5668\u53ef\u6d4b\u91cf0~100%\u6c27\u6c14\u6d53\u5ea6\uff0c\u5176\u53d7\u538b\u529b\u5f15\u8d77\u7684\u7075\u654f\u5ea6\u53d8\u5316\u4ec5\u4e3a\u4f20\u7edf\u6c27\u6c14\u4f20\u611f\u5668\u76841\/4\uff0c\u4e14\u5168\u91cf\u7a0b\u7ebf\u6027\u6781\u4f73\uff0c\u65e0\u9700\u5bf9\u6570\u62df\u5408\uff0c\u68c0\u6d4b\u9ad8\u6548\u7cbe\u51c6\u3002\u53ef\u901a\u8fc7\u7ba1\u811a\u66ff\u6362\u6807\u51c6\u56db\u7cfb\u5217\u6c27\u6c14\u4ea7\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4o2-lf-100-64efb2aa50.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4o2-lf-100-cbc3e4b1aa82.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7ce396605d845c00c6a6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4O2-LF-M\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 30% vol\u6c27\",\"sensitivity\":\"-90 \u00b1 24 \u03bcA\/% vol\u6c27\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05% vol\u6c27\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4O2-LF-M uses electrochemical sensing for Oxygen, with a measuring range of 0 ~ 30% vol\u6c27. It belongs to the 4 Series family.\",\"zh\":\"\u8fd9\u6b3e\u65e0\u94c5\u6c27\u4f20\u611f\u5668\u4ece\u51b7\u542f\u52a8\u5230\u8fdb\u5165\u5de5\u4f5c\u72b6\u6001\u6240\u9700\u9884\u70ed\u65f6\u95f4\u4e0d\u52304\u5206\u949f\uff0c\u800c\u6807\u51c6\u65e0\u94c5\u6c27\u4f20\u611f\u5668\u7684\u9884\u70ed\u65f6\u95f4\u9700\u898115\u5206\u949f\u3002\u6b64\u5916\uff0c\u5b83\u5728\u5e94\u5bf9\u73af\u5883\u538b\u529b\u6ce2\u52a8\u65b9\u9762\u8868\u73b0\u51fa\u6781\u4f73\u7684\u7a33\u5b9a\u6027\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4o2-lf-m-489037c854.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4o2-lf-m-5c0a8e592bcf.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:472674d922cdeda049bc\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4O2-LF\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 25%\u00a0vol\u6c27\",\"sensitivity\":\"-100 \u00b1 20 \u03bcA (\u7a7a\u6c14\u4e2d)\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1% vol\u6c27\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4O2-LF uses electrochemical sensing for Oxygen, with a measuring range of 0 ~ 25%\u00a0vol\u6c27. It belongs to the 4 Series family.\",\"zh\":\"\u8be5\u4f20\u611f\u5668\u662f\u65e0\u94c5\u7684\uff0c\u7528\u4e8e\u6d4b\u91cf\u6c27\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u6c27\u6c14\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4o2-lf-469287261f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4o2-lf-7dcbfd1eeaf6.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:caa4f17b38e20c712fb2\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMO2-LF\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 25% vol\u6c27\",\"sensitivity\":\"-100 \u00b1 20 \u03bcA (\u7a7a\u6c14\u4e2d)\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1% vol\u6c27\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"> 5 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMO2-LF uses electrochemical sensing for Oxygen, with a measuring range of 0 ~ 25% vol\u6c27. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u6c27\u6c14\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u6c27\u6c14\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smo2-lf-5c42c25966.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smo2-lf-f386a5187099.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:26db3af113195f54aa1e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini O2-LF\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 25%\u00a0vol\u6c27\",\"sensitivity\":\"-100 \u00b1 20 \u03bcA (\u7a7a\u6c14\u4e2d)\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1% vol\u6c27\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini O2-LF uses electrochemical sensing for Oxygen, with a measuring range of 0 ~ 25%\u00a0vol\u6c27. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u6c27\u6c14\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-o2-lf-e4445670d5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-o2-lf-d7da1d9b8f43.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:fcec87ba0a65ebba32d7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4O3-1\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1\u00a0ppm\",\"sensitivity\":\"-2.00 \u00b1 0.95 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.03 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4O3-1 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 1\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4o3-1-bb3dac737a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4o3-1-367e21cdaa9b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e29602bbd13f95f7d32d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4O3-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"-0.85 \u00b1 0.25 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4O3-10 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4o3-10-3fdd688b8e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4o3-10-0db66e87c6e5.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:6108e7e70b145bc15da6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4O3-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"-0.55 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4O3-100 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4o3-100-ed82854149.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4o3-100-bc00a6f6061b.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c30dc39875139568fbc3\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4O3-1000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"-0.17 \u00b1 0.03 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4O3-1000 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4o3-1000-31a5826a2b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4o3-1000-c865ba3e4de3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d273c30e2f0dea6f4021\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7O3-1\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1 ppm\",\"sensitivity\":\"-2.00 \u00b1 0.95 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7O3-1 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 1 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7o3-1-b690336484.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7o3-1-37ccebb6500c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a1f4363cd65ca9fe9776\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7O3-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"-0.55 \u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1\u00a0ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7O3-100 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7o3-100-3de35c85c6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7o3-100-5027aced3d68.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e5cd4ea1fa6e5cbbaa8d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7O3-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"-1.00 \u00b1 0.25 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-40\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7O3-20 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 20 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7o3-20-d4e0f30e5d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7o3-20-0163de7d16ea.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0b85f8456f04e720243c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E3-O3-1\",\"seriesKey\":\"semeatech:3-076a68d5\",\"series\":{\"en\":\"Environmental Monitoring - 3-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-3\u7535\u6781\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1 ppm\",\"sensitivity\":\"-0.6\u00a0\u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E3-O3-1 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 1 ppm. It belongs to the Environmental Monitoring - 3-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u73af\u5883\u7ea7\u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e3-o3-1-5334c01bb6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e3-o3-1-6e23593eca7e.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:de99e4d61769df155ab4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-O3-5\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"-0.45\u00a0\u00b1 0.20 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-O3-5 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\u8be5\u4ea7\u54c1\u7b26\u5408 CCEP\u65b0\u56fd\u68072021\u7248\u4e2d\u89c4\u5b9a\u7684\u6027\u80fd\u8981\u6c42\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-o3-5-0dc359c2ae.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-o3-5-a9ea7c6bec19.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:60989e8ccf750e605801\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini O3-10\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10\u00a0ppm\",\"sensitivity\":\"-0.26 \u00b1 0.06 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini O3-10 uses electrochemical sensing for Ozone, with a measuring range of 0 ~ 10\u00a0ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u81ed\u6c27\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae \u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-o3-10-2919cbc929.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-o3-10-7d4f47066ba4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ae2f8d0d1ddcaf5c57c7\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PH3-1000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.07 \u00b1 0.04 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4PH3-1000 uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u78f7\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ph3-1000-22183de590.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ph3-1000-ba479791bf23.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2104adf43f18c73b0cf6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PH3-1000A\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 1000 ppm\",\"sensitivity\":\"0.09 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4PH3-1000A uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 1000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u6b64\u6b3e\u78f7\u5316\u6c22\u4f20\u611f\u5668\u662f\u4e13\u95e8\u4e3a\u718f\u84b8\u5e94\u7528\u800c\u8bbe\u8ba1\u7684\u3002\u5728\u6709\u9ad8\u6d53\u5ea6\u78f7\u5316\u6c22\u7684\u4f7f\u7528\u73af\u5883\u4e0b\uff0c\u7075\u654f\u5ea6\u6ca1\u6709\u660e\u663e\u53d8\u5316\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u78f7\u5316\u6c22\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ph3-1000a-ce0e293d6e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ph3-1000a-e9f8effe23f0.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:eeba496c4e78815d345f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PH3-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"1.4 \u00b1 0.6 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4PH3-20 uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u78f7\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ph3-20-f063f17e1b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ph3-20-85ce74f7dcca.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5f52ccd2c3e294b111f8\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PH3-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.050\u00a0\u00b1 0.015 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4PH3-2000 uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u78f7\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ph3-2000-d156ee9a65.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ph3-2000-4d813d1b0657.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b37165f8f68844f173dd\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PH3-2000A\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.065 \u00b1 0.020 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4PH3-2000A uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u6b64\u6b3e\u78f7\u5316\u6c22\u4f20\u611f\u5668\u662f\u4e13\u95e8\u4e3a\u718f\u84b8\u5e94\u7528\u800c\u8bbe\u8ba1\u7684\u3002\u5728\u6709\u9ad8\u6d53\u5ea6\u78f7\u5316\u6c22\u7684\u4f7f\u7528\u73af\u5883\u4e0b\uff0c\u7075\u654f\u5ea6\u6ca1\u6709\u660e\u663e\u53d8\u5316\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u78f7\u5316\u6c22\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ph3-2000a-40a47e4268.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ph3-2000a-8c3a63a8fae8.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:6ee1a6e2c4331b7c9ff4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PH3-5\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5 ppm\",\"sensitivity\":\"2.0 \u00b1 0.6 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4PH3-5 uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 5 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u78f7\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4ph3-5-aafd5b99ac.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4ph3-5-1bd570d44668.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ded90581ab0c541c0fbc\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMPH3-2\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2\u00a0ppm\",\"sensitivity\":\"0.6 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.015 ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMPH3-2 uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 2\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u78f7\u5316\u6c22\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smph3-2-c3fe0b1726.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smph3-2-e6cb09c8d114.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:505b12dd4159fd30d625\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7PH3-2000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.07 \u00b1 0.04 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7PH3-2000 uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 2000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u78f7\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7ph3-2000-7f41127d5e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7ph3-2000-3f5f05e53d2f.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:8efe5c1378cbc65b5123\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7PH3-5\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"2.0 \u00b1 0.5 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7PH3-5 uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u78f7\u5316\u6c22\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7ph3-5-a3dcb9ea8c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7ph3-5-47498f26b5a7.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5ca263ce4fc25e50888f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini PH3-20A\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.45 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini PH3-20A uses electrochemical sensing for Phosphine, with a measuring range of 0 ~ 20 ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u78f7\u5316\u6c22\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-ph3-20a-7f087ffbf3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-ph3-20a-24efe7a69bf4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:dd9bb4aa8d2709e5bee3\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SiH4-10\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 10 ppm\",\"sensitivity\":\"1.5 \u00b1 0.5 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"1\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SiH4-10 uses electrochemical sensing for Silane, with a measuring range of 0 ~ 10 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7845\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u7845\u70f7\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4sih4-10-c76e69cf50.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4sih4-10-821afdd3d7e5.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:19c34592a81bf513c059\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SiH4-50\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.6 \u00b1 0.2 \u03bcA\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"1\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SiH4-50 uses electrochemical sensing for Silane, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u7845\u70f7\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u7845\u70f7\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4sih4-50-946be3ef90.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4sih4-50-6cf149615d9d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5fee44724595c736e4ac\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMSiH4-20\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"0.18 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMSiH4-20 uses electrochemical sensing for Silane, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u7845\u70f7\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u7845\u70f7\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smsih4-20-48819e581c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smsih4-20-cc391a9a8b67.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2bb14cc5f3a8326a10d4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3SO2-100CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3SO2-100CT uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e8c\u6c27\u5316\u786b\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3so2-100ct-21265b0cb4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3so2-100ct-ba65b332c243.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:04b7a2f9df177d1a9bc4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3SO2-2000\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3SO2-2000 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3so2-2000-dbc275141b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3so2-2000-e9a333d60694.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ed39509fd34a9ca42dba\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3SO2-2000CT\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3SO2-2000CT uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u6d53\u5ea6\uff0c\u5728\u6076\u52a3\u73af\u5883\u6761\u4ef6\u4e0b\u76d1\u6d4b\u548c\u5206\u6790\u70df\u56f1\u6392\u653e\u6216\u7b49\u6548\u4e8c\u6c27\u5316\u786b\u6d53\u5ea6\u3002\u5b83\u53ef\u4ee5\u66ff\u4ee3\u5e02\u573a\u4e0a\u4e3b\u6d41\u54c1\u724c\u76843\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3so2-2000ct-2beb80da32.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3so2-2000ct-dc98e724a915.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:280c6932e21786219d05\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"3SO2-500\",\"seriesKey\":\"semeatech:3-720be4f0\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 500 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 3SO2-500 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 500 ppm. It belongs to the 3 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e09\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/3so2-500-f02d3ec980.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-3so2-500-b5174210871d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b11776263645b273b795\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SO2-100\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SO2-100 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4so2-100-2689f90dbc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4so2-100-e084c2baeb1e.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:9f4bbbcb86765377f37f\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SO2-20\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.5\u00a0\u00b1 0.1\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SO2-20 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4so2-20-be97ddbb08.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4so2-20-735c66403254.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f5c9fac04bdd9ccb7bc2\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SO2-2000\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.020 \u00b1 0.008 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SO2-2000 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4so2-2000-d43a371b7b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4so2-2000-0021596acd05.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:161fb7155227afe1d79a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SO2-20B\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.45\u00a0\u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20\u2103 ~ 60\u2103\",\"humidity\":\"5% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SO2-20B uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u5728\u6709\u6e7f\u5ea6\u5f71\u54cd\u7684\u4f7f\u7528\u73af\u5883\u4e0b\uff0c\u7075\u654f\u5ea6\u6ca1\u6709\u660e\u663e\u53d8\u5316\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4so2-20b-f8ab6315b4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4so2-20b-bd6d0d78cdd3.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:9397243649678fdd1ee8\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SO2-20BF\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20 ppm\",\"sensitivity\":\"0.4\u00a0\u00b1 0.1\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20\u2103 ~ 60\u2103\",\"humidity\":\"5% ~ 95%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SO2-20BF uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u968f\u7740\u65f6\u95f4\u7684\u63a8\u79fb\u7075\u654f\u5ea6\u6ca1\u6709\u660e\u663e\u53d8\u5316\uff0c\u4e5f\u6ca1\u6709\u786b\u5316\u6c22\u4ea4\u53c9\u5e72\u6270\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4so2-20bf-593b992c52.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4so2-20bf-28b384ce6fb4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:b5ddd8fa5994f9e3c205\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SO2-5\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"0.55 \u00b1 0.15 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SO2-5 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4so2-5-161b9d6ed0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4so2-5-eef8835047bf.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3f16edb668f7002675b0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMSO2-20\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"0.4 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01\u00a0ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMSO2-20 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smso2-20-786e97eee6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smso2-20-dc09c22ed9fb.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:66f691956c38ec2d1720\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7SO2-100\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 100 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7SO2-100 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 100 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7so2-100-982ed7f26e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7so2-100-3df6ea4f8081.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:30ead57a158a2a5a4624\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7SO2-20\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"0.45\u00a0\u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 45\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7SO2-20 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7so2-20-74eaa462cd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7so2-20-dff7fd1a056e.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4ff9d932977e042c1141\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7SO2-2000\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"0.023 \u00b1 0.011 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"5 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7SO2-2000 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 2000 ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7so2-2000-134015bd2f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7so2-2000-781fc5d00e9a.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:9b09665db93863dcafc3\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7SO2-20B\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"0.5 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20\u2103 ~ 60\u2103\",\"humidity\":\"5% ~ 95%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7SO2-20B uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u5728\u6709\u6e7f\u5ea6\u5f71\u54cd\u7684\u4f7f\u7528\u73af\u5883\u4e0b\uff0c\u7075\u654f\u5ea6\u6ca1\u6709\u660e\u663e\u53d8\u5316\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u4e03\u7cfb\u5217\u7535\u5316\u5b66\u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7so2-20b-7836c5da74.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7so2-20b-7b5c1e4c456d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:84bab13332ab548d0526\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7SO2-20BF\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"0.45 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20\u2103 ~ 60\u2103\",\"humidity\":\"5% ~ 95%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7SO2-20BF uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u968f\u7740\u65f6\u95f4\u7684\u63a8\u79fb\u7075\u654f\u5ea6\u6ca1\u6709\u660e\u663e\u53d8\u5316\uff0c\u4e5f\u6ca1\u6709\u786b\u5316\u6c22\u4ea4\u53c9\u5e72\u6270\u3002\u5b83\u53ef\u4ee5\u4f5c\u4e3a\u5e02\u573a\u4e0a\u73b0\u6709\u7684\u6807\u51c6\u4e03\u7cfb\u5217\u7535\u5316\u5b66\u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\u7684\u66ff\u4ee3\u54c1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7so2-20bf-7122052d58.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7so2-20bf-cf86c700d190.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:da54963270428b917456\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7SO2-5\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"0.5\u00a0\u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.08 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7SO2-5 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7so2-5-6fff23e8a6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7so2-5-d6629f5fa9dd.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5b7676855c1da8284ea4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E3-SO2-5\",\"seriesKey\":\"semeatech:3-076a68d5\",\"series\":{\"en\":\"Environmental Monitoring - 3-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-3\u7535\u6781\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"0.5\u00a0\u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"15 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E3-SO2-5 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the Environmental Monitoring - 3-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u73af\u5883\u7ea7\u4e8c\u6c27\u5316\u786b\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e3-so2-5-325636b33b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e3-so2-5-dfb5912c8fc1.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:5413963367a53e390562\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7E4-SO2-5\",\"seriesKey\":\"semeatech:4-0f4cc5a1\",\"series\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 5\u00a0ppm\",\"sensitivity\":\"0.4\u00a0\u00b1 0.2\u00a0\u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10\u00a0ppb\",\"temperature\":\"-40\u2103 ~ 55\u2103\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"3 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7E4-SO2-5 uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 5\u00a0ppm. It belongs to the Environmental Monitoring - 4-electrode family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u56db\u7535\u6781\u7ed3\u6784\u8bbe\u8ba1\uff0c\u5229\u7528\u8865\u507f\u7b97\u6cd5\u63d0\u9ad8\u4f4e\u6d53\u5ea6\u6c14\u4f53\u6d4b\u91cf\u7684\u51c6\u786e\u6027\u3002\u8be5\u4ea7\u54c1\u7b26\u5408 CCEP\u65b0\u56fd\u68072021\u7248\u4e2d\u89c4\u5b9a\u7684\u6027\u80fd\u8981\u6c42\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7e4-so2-5-10ed675053.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7e4-so2-5-26b16e345ac5.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:981868b669190a0e3479\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini SO2-20B\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"0.25 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini SO2-20B uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-so2-20b-9fcd2578df.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-so2-20b-67e717b6c9d4.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:041b772542e81666c30d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini SO2-20BF\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 20\u00a0ppm\",\"sensitivity\":\"0.2 \u00b1 0.1 \u03bcA\/ppm\",\"responseTime\":\"\u2264 75\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02\u00a0ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103*\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini SO2-20BF uses electrochemical sensing for Sulfur Dioxide, with a measuring range of 0 ~ 20\u00a0ppm. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u4e8c\u6c27\u5316\u786b\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u53bb\u9664\u5927\u90e8\u5206\u786b\u5316\u6c22\u6c14\u4f53\u5e72\u6270\u3002\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-so2-20bf-577c52c3d7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-so2-20bf-4893355d9c72.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7867c2269d7e58159170\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4SMTEOS-50\",\"seriesKey\":\"semeatech:4sm-d02522fc\",\"series\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"},\"gas\":\"TEOS\",\"gasName\":{\"en\":\"Tetraethyl Orthosilicate\",\"zh\":\"\u6b63\u7845\u9178\u4e59\u916f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0ppm\",\"sensitivity\":\"0.85 \u00b1 0.40 \u03bcA\/ppm\",\"responseTime\":\"\u2264 120\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1\u00a0ppm\",\"temperature\":\"0\u2103 ~ 40\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"> 2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4SMTEOS-50 uses electrochemical sensing for Tetraethyl Orthosilicate, with a measuring range of 0 ~ 50\u00a0ppm. It belongs to the 4SM Process Gas family.\",\"zh\":\"\u672c\u6b63\u7845\u9178\u4e59\u916f\u6c14\u4f53\u4f20\u611f\u5668\u53ef\u5e94\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u7a0b\u884c\u4e1a\u9700\u8981\u6d4b\u91cf\u6b63\u7845\u9178\u4e59\u916f\u6c14\u4f53\u6d53\u5ea6\u7684\u573a\u5408\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4smteos-50-1c14ffb3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4smteos-50-e660b80eaed8.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:7ae298086a81589e12f1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4THT-50 mg\/m\u00b3\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0mg\/m\u00b3\",\"sensitivity\":\"0.15\u00a0\u00b1 0.10\u00a0\u03bcA\/(mg\/m\u00b3)\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.3\u00a0mg\/m\u00b3\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4THT-50 mg\/m\u00b3 uses electrochemical sensing for Tetrahydrothiophene, with a measuring range of 0 ~ 50\u00a0mg\/m\u00b3. It belongs to the 4 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u56db\u6c22\u567b\u5429\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u56db\u7cfb\u5217\u56db\u6c22\u567b\u5429\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4tht-50-mg-m3-539a3361f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4tht-50-mg-m3-a07a6f460e8c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:9e7d7b969914406ffd96\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4THT-50 ppm\",\"seriesKey\":\"semeatech:4-945a8221\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"0.35 \u00b1 0.10 \u03bcA\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 4THT-50 ppm uses electrochemical sensing for Tetrahydrothiophene, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series family.\",\"zh\":\"\u8be5\u56db\u6c22\u567b\u5429\u4f20\u611f\u5668\u4f7f\u7528\u56fd\u9645\u548c\u68c0\u6d4b\u884c\u4e1a\u66f4\u4e3a\u901a\u7528\u7684ppm\u4f5c\u4e3a\u6d53\u5ea6\u5355\u4f4d\uff0c\u53ef\u907f\u514d\u590d\u6742\u7684\u5355\u4f4d\u6362\u7b97\u8fc7\u7a0b\uff0c\u65b9\u4fbf\u5ba2\u6237\u4f7f\u7528\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4tht-50-ppm-ba23ba45f4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4tht-50-ppm-3da1bec53552.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f31b2e83ac1435125a34\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7THT-50 mg\/m\u00b3\",\"seriesKey\":\"semeatech:7-d228187f\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50\u00a0mg\/m\u00b3\",\"sensitivity\":\"0.15\u00a0\u00b1 0.10\u00a0\u03bcA\/(mg\/m\u00b3)\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.3\u00a0mg\/m\u00b3\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"15% ~ 90%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"2\u00a0\u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech 7THT-50 mg\/m\u00b3 uses electrochemical sensing for Tetrahydrothiophene, with a measuring range of 0 ~ 50\u00a0mg\/m\u00b3. It belongs to the 7 Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u56db\u6c22\u567b\u5429\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u53ef\u4ee5\u901a\u8fc7\u7ba1\u811a\u6765\u66ff\u6362\u6807\u51c6\u7684\u4e03\u7cfb\u5217\u56db\u6c22\u567b\u5429\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7tht-50-mg-m3-61940b085a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7tht-50-mg-m3-0ec14c5f3b27.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:0a29c371405d7edf7118\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"mini THT-50 mg\/m\u00b3\",\"seriesKey\":\"semeatech:mini-4067e3db\",\"series\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 ~ 50 mg\/m\u00b3\",\"sensitivity\":\"0.10 \u00b1 0.05 \u03bcA\/(mg\/m\u00b3)\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 mg\/m\u00b3\",\"temperature\":\"-20\u00b0C ~ 50\u00b0C\",\"humidity\":\"15% ~ 90%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"2 \u5e74 (\u7a7a\u6c14\u4e2d)\"},\"description\":{\"en\":\"SemeaTech mini THT-50 mg\/m\u00b3 uses electrochemical sensing for Tetrahydrothiophene, with a measuring range of 0 ~ 50 mg\/m\u00b3. It belongs to the Mini Series family.\",\"zh\":\"\u672c\u4ea7\u54c1\u7528\u4e8e\u6d4b\u91cf\u56db\u6c22\u567b\u5429\u6c14\u4f53\u7684\u6d53\u5ea6\uff0c\u91c7\u7528\u5168\u65b0\u5fae\u578b\u7ed3\u6784\uff0c\u5177\u6709\u77ed\u3001\u5c0f\u3001\u8f7b\u3001\u8584\u7684\u7279\u70b9\uff0c\u66f4\u9002\u7528\u4e8e\u4fbf\u643a\u8896\u73cd\u5f0f\u4eea\u5668\u4eea\u8868\u3002\u4e0d\u5efa\u8bae\u5728\u6076\u52a3\u73af\u5883\u4e2d\u957f\u671f\u5728\u7ebf\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/mini-tht-50-mg-m3-cac46bce6c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-mini-tht-50-mg-m3-f6abecd63a60.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ab4faf83495c5dab5cc1\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID Plus-100\",\"seriesKey\":\"semeatech:4-pid-plus-7a3d9fbd\",\"series\":{\"en\":\"4 Series PID Plus\",\"zh\":\"4\u7cfb\u5217PID Plus\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"100 ppm\",\"sensitivity\":\"> 10 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"25 ppb\",\"temperature\":\"-20\u2103 ~ 55\u2103\",\"humidity\":\"0% ~ 99%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"5 \u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID Plus-100 uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 100 ppm. It belongs to the 4 Series PID Plus family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-plus-100-9d1561b57e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-plus-100-78bdf112fac5.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:e2c2e7c9b1892bf3cd39\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID Plus-200\",\"seriesKey\":\"semeatech:4-pid-plus-7a3d9fbd\",\"series\":{\"en\":\"4 Series PID Plus\",\"zh\":\"4\u7cfb\u5217PID Plus\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"200 ppm\",\"sensitivity\":\"> 5\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"50 ppb\",\"temperature\":\"-20\u2103 ~ 55\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID Plus-200 uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 200 ppm. It belongs to the 4 Series PID Plus family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-plus-200-1372264e7b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-plus-200-965875d94920.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:ec4bdf672bcd94b299c6\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID Plus-2000\",\"seriesKey\":\"semeatech:4-pid-plus-7a3d9fbd\",\"series\":{\"en\":\"4 Series PID Plus\",\"zh\":\"4\u7cfb\u5217PID Plus\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"2000 ppm\",\"sensitivity\":\"> 5 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"500 ppb\",\"temperature\":\"-20\u2103 ~ 55\u2103\",\"humidity\":\"0% ~ 99%RH (\u65e0\u51b7\u51dd)\",\"lifetime\":\"5 \u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID Plus-2000 uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 2000 ppm. It belongs to the 4 Series PID Plus family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-plus-2000-ee76dd020c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-plus-2000-54f2012e4266.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:1d7c7f21119cdec79eb0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0 ~ 10000 ppm\",\"sensitivity\":\"> 0.1 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2000 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 0 ~ 10000 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-f0678503f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-17429ac348a9.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f917d8f1f58ffb3bae4c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0 ~ 200 ppm\",\"sensitivity\":\"> 5 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"50 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 0 ~ 200 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-45873b554d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-3684365485d9.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2bd32fbcc9e312454cab\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0 ~ 2000 ppm\",\"sensitivity\":\"> 0.5 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"500 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 0 ~ 2000 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-5472ce382d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-8524f9f8eeff.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:36963357d4437fd1ecee\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0 ~ 50 ppm\",\"sensitivity\":\"> 20 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 0 ~ 50 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-d1e68e732e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-1d13a6d13315.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:2498363e8481d81e6ff9\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"10 ppm\",\"sensitivity\":\"> 100\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1\u00a0ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 10 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-2f6aa79daf.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-5de3dba391c7.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:a32b6c834c4122e94483\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"100 ppm\",\"sensitivity\":\"> 10\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"25 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 100 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-2274f1840b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-87d1d21b8266.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:d9206160e02b4baf279d\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"1000 ppm\",\"sensitivity\":\"> 1\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"250 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 1000 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-0d1c5e435a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-d2cca14d66f7.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:9d3e09165048760d7853\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"10000 ppm\",\"sensitivity\":\"> 0.1\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2000 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 10000 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-fac7e8aa9b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-180f1c432e7d.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:6ce2996d3f3a7cdbeaaa\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"20 ppm\",\"sensitivity\":\"> 50\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"2 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 20 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-3c24ef6ce4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-f76ff561bf43.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4b30f45c209a78452cec\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"200 ppm\",\"sensitivity\":\"> 5 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"50 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 200 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-db615d4f0f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-cfff7d3cd9f2.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3f030d168d67b4a02ac4\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"2000 ppm\",\"sensitivity\":\"> 0.5\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"500 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 2000 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-a8a7121035.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-293a423e7cab.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c66c27840e91345f7642\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"5 ppm\",\"sensitivity\":\"> 200\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\u2264 200 ppt\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 5 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-417fbcc9cd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-bc878a2d444c.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:38459f602344a05f5c17\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"50 ppm\",\"sensitivity\":\"> 20\u00a0mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 50 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-9a82b52f76.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-d2a587a57002.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:f5c7bb8dfd32c05ba25e\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"4PID\",\"seriesKey\":\"semeatech:4-pid-d9776957\",\"series\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"5000 ppm\",\"sensitivity\":\"> 0.2 mV\/ppm\",\"responseTime\":\"< 5 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1000 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 4PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 5000 ppm. It belongs to the 4 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/4pid-6f5ea4f64a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-4pid-1296aba426f8.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:3b6ab39777b6d9432057\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7PID\",\"seriesKey\":\"semeatech:7-pid-7734bbbd\",\"series\":{\"en\":\"7 Series PID\",\"zh\":\"7\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"100 ppm\",\"sensitivity\":\"> 10\u00a0mV\/ppm\",\"responseTime\":\"< 10\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"20 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 7PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 100 ppm. It belongs to the 7 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7pid-716cf39ae4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7pid-568bac1ff082.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:55c71be72735d71e628c\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7PID\",\"seriesKey\":\"semeatech:7-pid-7734bbbd\",\"series\":{\"en\":\"7 Series PID\",\"zh\":\"7\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"20 ppm\",\"sensitivity\":\"> 60\u00a0mV\/ppm\",\"responseTime\":\"< 10\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1\u00a0ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 7PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 20 ppm. It belongs to the 7 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7pid-cb99fd8978.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7pid-5d15128b82b2.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:4291fb74dc25b0fe0c4a\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7PID\",\"seriesKey\":\"semeatech:7-pid-7734bbbd\",\"series\":{\"en\":\"7 Series PID\",\"zh\":\"7\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"2000 ppm\",\"sensitivity\":\"> 0.5 mV\/ppm\",\"responseTime\":\"< 10\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"500 ppb\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 7PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 2000 ppm. It belongs to the 7 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7pid-11cf170b78.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7pid-6ba7428b2c95.pdf\",\"match\":\"exact\"}]},{\"id\":\"semeatech:c8ec786b8eab599417d0\",\"brandKey\":\"semeatech\",\"brandName\":\"SemeaTech\",\"model\":\"7PID\",\"seriesKey\":\"semeatech:7-pid-7734bbbd\",\"series\":{\"en\":\"7 Series PID\",\"zh\":\"7\u7cfb\u5217PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"5 ppm\",\"sensitivity\":\"> 200\u00a0mV\/ppm\",\"responseTime\":\"< 10\u00a0s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\u2264\u00a0200 ppt\",\"temperature\":\"-20\u2103 ~ 50\u2103\",\"humidity\":\"0% ~ 99%RH\u00a0(\u65e0\u51b7\u51dd)\",\"lifetime\":\"5\u00a0\u5e74 (\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668)\"},\"description\":{\"en\":\"SemeaTech 7PID uses pid photoionization sensing for Volatile Organic Compounds, with a measuring range of 5 ppm. It belongs to the 7 Series PID family.\",\"zh\":\"\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/7pid-1fd8504167.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/semeatech\/documents\/semeatech-7pid-0483beab7762.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:567cd69c7e77b9ddff6f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"AsH3\/C-1\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"4200 \u00b1 800 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"AsH3 Gas Sensor in Compact Housing. Key features: Highly sensitive Arsine detection. Applications: Safety and Process Control; Discontinuous Measurement. highly sensitive.\",\"zh\":\"Membrapor AsH3\/C-1 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7837\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ash3-c-1-46a232aa87.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:cad95f953117569f9366\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"AsH3\/M-1\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"3000 \u00b1 600 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"AsH3 Gas Sensor in Miniature Housing. Key features: Highly sensitive Arsine detection. Applications: Safety and Process Control; Discontinuous Measurement; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor AsH3\/M-1 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7837\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ash3-m-1-c573c3dc57.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5041b638305eae23f3a5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"B2H6\/C-1\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"B2H6\",\"gasName\":{\"en\":\"Diborane\",\"zh\":\"\u4e59\u787c\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"900 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"B2H6 Gas Sensor in Compact Housing. Key features: Detection of low B2H6 Concentration. Applications: Safety and Process Control; For Use in Semiconductor Industry.\",\"zh\":\"Membrapor B2H6\/C-1 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u787c\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-b2h6-c-1-9c7ba9efae.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7b4194d1dc927fbcc56f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"B2H6\/M-1\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"B2H6\",\"gasName\":{\"en\":\"Diborane\",\"zh\":\"\u4e59\u787c\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"800 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"B2H6 Gas Sensor in Miniature Housing. Key features: Detection of low B2H6 Concentration. Applications: Safety and Process Control; For Use in Semiconductor Industry.\",\"zh\":\"Membrapor B2H6\/M-1 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u787c\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-b2h6-m-1-9538a749a3.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3497ccc02e46f6971003\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H2\/CF-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Ethyne \/ Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"2000 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H2 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Chemical Synthesis; Welding and Cutting Processes. highly sensitive.\",\"zh\":\"Membrapor C2H2\/CF-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u7094\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h2-cf-20-cf7aa50f28.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:72db1e9684b1698d299a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H2\/CF-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Ethyne \/ Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"500 \u00b1 100 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H2 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Chemical Synthesis; Welding and Cutting Processes.\",\"zh\":\"Membrapor C2H2\/CF-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u7094\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h2-cf-200-6fbcc21033.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:58640139d4e146b9abe2\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H2\/CF-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Ethyne \/ Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H2 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Chemical Synthesis; Welding and Cutting Processes.\",\"zh\":\"Membrapor C2H2\/CF-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u7094\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h2-cf-2000-e0a0eb4917.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:403d30d9fb495a963d8a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/C-10\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"400 \u00b1 120 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Fruit Ripening. highly sensitive.\",\"zh\":\"Membrapor C2H4\/C-10 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-c-10-2b43a2c352.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:178f91ca02f24ed49741\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/C-1500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1500 ppm\",\"sensitivity\":\"11 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Fruit Ripening.\",\"zh\":\"Membrapor C2H4\/C-1500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 1500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-c-1500-0ae3970902.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3a2dc7bbfccef463c662\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"100 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Fruit Ripening.\",\"zh\":\"Membrapor C2H4\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-c-200-6282b6ed88.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:51a26f2df8da09f23f0a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/CA-10\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"350 \u00b1 120 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Compact Housing. Key features: Highly selective Ethylene measurement in presence of CO and Alcohols. Applications: Discontinuous Measurement; Fruit Ripening. highly selective.\",\"zh\":\"Membrapor C2H4\/CA-10 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-ca-10-8fa3120400.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:c37acf30938e87e5bbb9\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/M-10\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"400 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Fruit Ripening; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor C2H4\/M-10 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-m-10-e0908fadc6.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:c5b1a9e58ef3c0371304\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/M-1500\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1500 ppm\",\"sensitivity\":\"11 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Fruit Ripening; For Portable Gas Detectors.\",\"zh\":\"Membrapor C2H4\/M-1500 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 1500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-m-1500-3cc10c8ee3.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6e9cc35a5136d42d9e70\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/M-200\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"75 \u00b1 25 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Fruit Ripening; For Portable Gas Detectors.\",\"zh\":\"Membrapor C2H4\/M-200 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-m-200-d443a01299.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e0b118f1a0aa3a27cdac\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/S-1500-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1500 ppm\",\"sensitivity\":\"11 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Slim Housing. Applications: Discontinuous Measurement; Fruit Ripening.\",\"zh\":\"Membrapor C2H4\/S-1500-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 1500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-s-1500-s-6d373c5a56.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d6fbd849d09b0befaad3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/S-200-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"100 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Slim Housing. Applications: Discontinuous Measurement; Fruit Ripening.\",\"zh\":\"Membrapor C2H4\/S-200-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-s-200-s-92707931d6.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0b949d6de533a7bd5a5b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/S-1500\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1500 ppm\",\"sensitivity\":\"11 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Standard Housing. Applications: Discontinuous Measurement; Fruit Ripening.\",\"zh\":\"Membrapor C2H4\/S-1500 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 1500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-s-1500-11a576402f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:309b0f9b606fc98ebda5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"C2H4\/S-200\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethene \/ Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"100 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4 Gas Sensor in Standard Housing. Applications: Discontinuous Measurement; Fruit Ripening.\",\"zh\":\"Membrapor C2H4\/S-200 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-c2h4-s-200-7fde964a0e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2d0f0480240f298a6e9c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/C-10\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"4600 \u00b1 1200 nA\/ppm\",\"responseTime\":\"< 30 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Compact Housing. Key features: Highly sensitive CH2O measurement. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor CH2O\/C-10 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-c-10-8590d6bbfd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:9924d9ac4227b301b9a1\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"90 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 30 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Compact Housing. Applications: Safety and Environmental Control.\",\"zh\":\"Membrapor CH2O\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-c-1000-26d341bf80.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:bd1bf3408c871c5a37a6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/CA-10\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"1500 \u00b1 500 nA\/ppm\",\"responseTime\":\"< 90 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Compact Housing. Key features: Highly selective CH2O measurement; Low alcohol cross sensitivity. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly selective.\",\"zh\":\"Membrapor CH2O\/CA-10 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-ca-10-b22e5bf39d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5e105620b003fef56342\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/CA-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"180 \u00b1 60 nA\/ppm\",\"responseTime\":\"< 90 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Compact Housing. Key features: Highly selective CH2O measurement; Low alcohol cross sensitivity. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly selective.\",\"zh\":\"Membrapor CH2O\/CA-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-ca-100-d3f567b72b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3edcf347aa3af7ae9010\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/M-10-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"2200 \u00b1 800 nA\/ppm\",\"responseTime\":\"< 30 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor CH2O\/M-10-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-m-10-2e-e9f853dcc3.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b9f53afe400ffe3c6eb1\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/M-10\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"4600 \u00b1 1200 nA\/ppm\",\"responseTime\":\"< 30 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor CH2O\/M-10 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-m-10-fb6429d490.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:dfc59f79d63300d5bf8e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/M-1000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"60 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 30 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor CH2O\/M-1000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-m-1000-d1e315975c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e38c8cb1f7256f5f7052\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/M-50\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"1000 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 30 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor CH2O\/M-50 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-m-50-153bb6439d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7530ed6fffa29fe46a2f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH2O\/S-10\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"4600 \u00b1 1200 nA\/ppm\",\"responseTime\":\"< 40 s (T60)\",\"responseLabel\":{\"en\":\"Response Time T60\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T60\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CH2O Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor CH2O\/S-10 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch2o-s-10-7caa2f7b6d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:562f622d06141c6ff7ba\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CH4\/IR-5\",\"seriesKey\":\"membrapor:non-dispersive-infrared-sensors-ndir-54b2597e\",\"series\":{\"en\":\"Non-Dispersive Infrared Sensors (NDIR)\",\"zh\":\"\u975e\u5206\u5149\u7ea2\u5916\u4f20\u611f\u5668\uff08NDIR\uff09\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"0 - 5%vol (0 - 100% LEL)\",\"sensitivity\":\"\",\"responseTime\":\"< 30s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"description\":{\"en\":\"NDIR Gas Sensor for Methane Detection. Membrapor\u2019s CH4\/IR-5 is a dual-channel Non-Dispersive Infrared (NDIR) methane sensor. It provides reliable, precise, and selective measurements for applications such as continuous threshold monitoring and leak detection in oil &#038; gas, biogas, and landfill environments. Key features: Small and compact 4-Series format.\",\"zh\":\"Membrapor CH4\/IR-5 \u662f\u4e00\u6b3e\u975e\u5206\u5149\u7ea2\u5916\u4f20\u611f\u5668\uff08NDIR\uff09\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 5%vol (0 - 100% LEL)\u3002\u68c0\u6d4b\u539f\u7406\u4e3aNDIR \u975e\u5206\u5149\u7ea2\u5916\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-non-dispersive-infrared-sensors-ndir-0037bd8700.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ch4-ir-5-4090722d26.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:c801750da71b61d11584\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/C-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"- 900 \u00b1 250 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Compact Housing. Key features: Highly sensitive Cl2 measurement. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor Cl2\/C-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-c-20-f477f5343f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3dda60d0f54224d7db43\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"- 140 \u00b1 35 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor Cl2\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-c-200-e5bfea763e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2481c0a758958c6b62dc\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/C-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"- 10 \u00b1 3 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 8.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor Cl2\/C-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-c-2000-0cd9c52d36.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:04b644392dce5c6aa987\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/C-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"- 4 \u00b1 1 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 20.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor Cl2\/C-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-c-5000-a725c23690.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:45e45a43e0cf5d7907a5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/M-20\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"- 600 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Miniature Housing. Key features: Highly sensitive Cl2 measurement. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor Cl2\/M-20 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-m-20-1dbe64ea07.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:657e4ab934a0cdc398df\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/M-200\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"- 120 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Miniature Housing. Applications: Safety and Process Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor Cl2\/M-200 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-m-200-24ec714884.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:107d30bed8476b5f50b0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/M-2EG\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"280 \u00b1 80 nA\/ppm 1)\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Miniature Housing. Applications: Air Quality Monitoring; Safety and Environmental Control; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor Cl2\/M-2EG \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-m-2eg-0d11174716.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:92d3fef607d2cfbcf1fd\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/S-20-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"- 900 \u00b1 250 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor Cl2\/S-20-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-s-20-s-e1c271a76a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7cb28f05545ae7d39d3b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/S-20\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"- 900 \u00b1 250 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor Cl2\/S-20 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-s-20-a28d0a67b6.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:f01084bbe93773ff02e3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Cl2\/S-50\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine \/ Bromine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"- 450 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"Cl2 Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor Cl2\/S-50 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cl2-s-50-d1ee3d6b55.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:8c19ab15e9ceaceb9835\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ClO2\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"- 140 \u00b1 35 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"ClO2 Gas Sensor in Compact Housing. Applications: Disinfection Processes; Bleaching Processes.\",\"zh\":\"Membrapor ClO2\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2f\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-clo2-c-200-d014a37368.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:726af60dac46752174f3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ClO2\/C-5\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5 ppm\",\"sensitivity\":\"- 900 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"ClO2 Gas Sensor in Compact Housing. Applications: Disinfection Processes; Bleaching Processes.\",\"zh\":\"Membrapor ClO2\/C-5 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2f\uff0c\u91cf\u7a0b\u4e3a 0 - 5 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-clo2-c-5-db42b8b248.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:65a8f230507c4352d8f4\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ClO2\/M-5\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5 ppm\",\"sensitivity\":\"- 600 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"ClO2 Gas Sensor in Miniature Housing. Applications: Disinfection Processes; Bleaching Processes; For Portable Gas Detectors.\",\"zh\":\"Membrapor ClO2\/M-5 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2f\uff0c\u91cf\u7a0b\u4e3a 0 - 5 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-clo2-m-5-78b60cfecd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:bfa33340cb69d339f796\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor CO\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-c-1000-684ff0fce1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:db348817eb5717df4ce0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"900 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Key features: Highly sensitive CO measurement. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor CO\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-c-200-90f5e0c67d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:69642ef52c0ed0d85cc3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor CO\/CF-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-1000-898d338287.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:aa9b969715abfcb28306\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-10000-4E\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 4 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring; H2-Compensated CO Measurement. Hydrogen compensated.\",\"zh\":\"Membrapor CO\/CF-10000-4E \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-10000-4e-9aa4355836.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:286147304002e5a5a2e2\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-200-4E\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"470 \u00b1 120 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Key features: Selective measurement of low CO concentrations in presence of H2. Applications: H2-Compensated CO Measurements; Medical Applications. Hydrogen compensated.\",\"zh\":\"Membrapor CO\/CF-200-4E \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-200-4e-5dbb76c78b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6dedae9d5cf81fd882ed\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"700 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Key features: Selective and sensitive measurement of low CO concentrations. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive, with filter.\",\"zh\":\"Membrapor CO\/CF-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-200-297f81960c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2d630a534bb72a743e0e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-2000-4E\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"75 \u00b1 25 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring; H2-Compensated CO Measurement. Hydrogen compensated.\",\"zh\":\"Membrapor CO\/CF-2000-4E \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-2000-4e-ddf90c9209.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:f5d43b6675e69fa1a4e5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Stack\/Flue Gas Monitoring; Emission \/ Flue Gas Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor CO\/CF-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-2000-2cb5dac5c7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:fd585a72954f43ca12a4\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-4000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 4000 ppm\",\"sensitivity\":\"30 \u00b1 6 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Stack\/Flue Gas Monitoring; Emission \/ Flue Gas Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor CO\/CF-4000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 4000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-4000-08f4773b29.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:47888bf84aeb0b40680a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-40000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 40000 ppm\",\"sensitivity\":\"6 \u00b1 2 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 10.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Stack\/Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor CO\/CF-40000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 40000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-40000-15c18dc965.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3da3a2f0595df24d118e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CF-500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"200 \u00b1 40 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor CO\/CF-500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cf-500-290b1f55f8.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:59c878b5c4549e5e398e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CFA-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/CFA-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cfa-1000-e20ada94e7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:54761dfd12b9bebd82e8\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CFA-10000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 4 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/CFA-10000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cfa-10000-70208c186e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0cea9c0c5c10327a5adf\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CFA-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"550 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: CO Detection in CO\/H2-Mixtures; Medical Applications. highly selective.\",\"zh\":\"Membrapor CO\/CFA-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cfa-200-ffe2c10258.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:14f55da1a8114cd39328\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CFA-500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"160 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/CFA-500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cfa-500-bec29d9bd3.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2adadbfbb22d797b2ff3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/CFA-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"30 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Compact Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/CFA-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-cfa-5000-7d50179978.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7a2cb359927682835b09\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/MF-1000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"50 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor CO\/MF-1000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-mf-1000-5506af1016.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d9c98d89b3b3f1c3b5d7\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/MF-200\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"600 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor CO\/MF-200 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-mf-200-29fb714b98.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5721bb24c8b2d40c3c6b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/MF-2000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"30 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor CO\/MF-2000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-mf-2000-f1b788807c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:df94c7c71696d63ecbdf\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/MF-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 300 ppm\",\"sensitivity\":\"50 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor CO\/MF-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 300 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-mf-2e-4263e52b0e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:921348c46e05d9df401b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/MF-500\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"70 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.8 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor CO\/MF-500 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-mf-500-3d633123aa.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:836de980b1277e6daf45\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/MFA-500\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"70 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Miniature Housing. Applications: CO Detection in CO\/H2-Mixtures; For Portable Gas Detectors. highly selective.\",\"zh\":\"Membrapor CO\/MFA-500 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-mfa-500-d776335729.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d7f9dddf38bb154becd6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/S-1000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor CO\/S-1000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-s-1000-s-21e1a7d2f1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e82cefe8bda5c13faf08\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-1000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. with filter.\",\"zh\":\"Membrapor CO\/SF-1000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-1000-s-5abd4ba143.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:15875e9b4fedcc826558\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-10000-4E-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"17 \u00b1 4 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 5.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring; H2-Compensated CO Measurement. Hydrogen compensated.\",\"zh\":\"Membrapor CO\/SF-10000-4E-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-10000-4e-s-9b6c67943d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:75ba8d5266fe0bb7f492\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-200-4E-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"500 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control; H2-Compensated CO Measurement. Hydrogen compensated.\",\"zh\":\"Membrapor CO\/SF-200-4E-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-200-4e-s-a9cf3db317.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:45a60064fe23d6838d98\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-200-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"700 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor CO\/SF-200-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-200-s-32cfeb8a12.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d6c45adb4b5ca0371212\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-2000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor CO\/SF-2000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-2000-s-50ad6cda6a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:1747c521c25cb2a14499\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-2E-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 300 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. 2-electrodes sensor.\",\"zh\":\"Membrapor CO\/SF-2E-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 300 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-2e-s-c270a4908b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:fba7303b9e602e965e2e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-4000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 4000 ppm\",\"sensitivity\":\"30 \u00b1 6 nA\/ppm\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor CO\/SF-4000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 4000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-4000-s-675eadab64.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:8c40b782904046aa2441\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-40000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 40000 ppm\",\"sensitivity\":\"7 \u00b1 1 nA\/ppm\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 10.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor CO\/SF-40000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 40000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-40000-s-97883adb57.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:57854e22a9117f5e4450\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SFA-10000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 4 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 5.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/SFA-10000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sfa-10000-s-eb73b2acf2.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:8e08f07338dcce2c9cdf\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SFA-200-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"550 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/SFA-200-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sfa-200-s-1df9e896c0.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:c9c9d3930513a32cd1da\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SGF-4E-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"80 \u00b1 25 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring; H2-Compensated CO Measurement. Hydrogen compensated.\",\"zh\":\"Membrapor CO\/SGF-4E-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sgf-4e-s-32acaa4baa.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ae0b8bd96ab5f12f454b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-1000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor CO\/SF-1000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-1000-7dcad15a88.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a56cc7664fc7350087fc\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-200\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"700 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor CO\/SF-200 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-200-ee4620b49e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:50d606ab4e0099e08cce\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SF-500\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"250 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor CO\/SF-500 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sf-500-9a5e38f727.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e64fed40a45699559b9c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SFA-1000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Standard Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/SFA-1000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sfa-1000-51a4d1ba67.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:f18e0ea5c4321731a15d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SFA-10000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 4 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 5.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Standard Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/SFA-10000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sfa-10000-f53fc49151.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3fa684066155b2b64ad4\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/SFA-200\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"550 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Standard Housing. Applications: CO Detection in CO\/H2-Mixtures; Emission \/ Flue Gas Monitoring. highly selective.\",\"zh\":\"Membrapor CO\/SFA-200 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-sfa-200-d42fca0d92.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:9514b190b12234af36cc\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/VF-10000-4E\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Vantage Housing. Key features: Replaceable Filter; Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring; H2-Compensated CO Measurement. Hydrogen-compensated CO SensorFlue Gas Application.\",\"zh\":\"Membrapor CO\/VF-10000-4E \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-vf-10000-4e-d960621aad.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a9504d465bc98a55c784\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/VF-2000-4E\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"65 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Vantage Housing. Key features: Replaceable Filter; Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring; H2-Compensated CO Measurement. Hydrogen-compensated CO SensorFlue Gas Application.\",\"zh\":\"Membrapor CO\/VF-2000-4E \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-vf-2000-4e-c04067bd7d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:46325d7eeafa972db954\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/VF-4000\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 4000 ppm\",\"sensitivity\":\"30 \u00b1 6 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Vantage Housing. Key features: Replaceable Filter; Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor CO\/VF-4000 \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 4000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-vf-4000-012cbc4716.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e84388e71668f6c5a001\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CO\/VF-40000\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 40000 ppm\",\"sensitivity\":\"10 \u00b1 4 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 6.0 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CO Gas Sensor in Vantage Housing. Key features: Replaceable Filter; Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor CO\/VF-40000 \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 40000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-co-vf-40000-a1b921decd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d2478a9e20bd341ccca1\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CS2\/CF-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CS2\",\"gasName\":{\"en\":\"Carbon Disulfide\",\"zh\":\"\u4e8c\u786b\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"200 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CS2 Gas Sensor in Compact Housing. Key features: Highly selective and sensitive CS2 detection; Ideal for TLV-TWA level measurements. Applications: Discontinuous Measurement; Safety and Process Control. highly selective.\",\"zh\":\"Membrapor CS2\/CF-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u786b\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cs2-cf-100-5ba6316a54.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:83370f9e64669b0ff131\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CS2\/CF-500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CS2\",\"gasName\":{\"en\":\"Carbon Disulfide\",\"zh\":\"\u4e8c\u786b\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CS2 Gas Sensor in Compact Housing. Key features: Highly selective CS2 detection. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor CS2\/CF-500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u786b\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cs2-cf-500-8448246261.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0f4bbbc945626f746da8\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"CS2\/MF-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CS2\",\"gasName\":{\"en\":\"Carbon Disulfide\",\"zh\":\"\u4e8c\u786b\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"120 \u00b1 60 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"CS2 Gas Sensor in Miniature Housing. Key features: Highly selective and sensitive CS2 detection. Applications: Discontinuous Measurement; Safety and Process Control; For Portable Gas Detectors. highly selective.\",\"zh\":\"Membrapor CS2\/MF-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u786b\u5316\u78b3\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-cs2-mf-100-9d45e97ce2.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:aff8736c7299c0d3b5c2\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/C-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"130 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Compact Housing. Applications: Sterilization Processes; Safety and Process Control.\",\"zh\":\"Membrapor ETO\/C-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-c-100-a4f4b0579c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:453860bb6620f073fd6c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"80 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Compact Housing. Applications: Sterilization Processes; Safety and Process Control.\",\"zh\":\"Membrapor ETO\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-c-1000-a3b8b94841.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7588036c5d47760b836f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/C-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"2500 \u00b1 600 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Compact Housing. Key features: Highly sensitive ETO measurement. Applications: Sterilization Processes; Safety and Process Control. highly sensitive.\",\"zh\":\"Membrapor ETO\/C-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-c-20-6691a2ea68.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ae7027120971c2e0be1d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/C-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"23 \u00b1 6 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 15.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Compact Housing. Applications: Sterilization Processes; Safety and Process Control.\",\"zh\":\"Membrapor ETO\/C-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-c-5000-cdc06619a4.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7b3274b776318b938519\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/CA-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"1600 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 120 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Compact Housing. Key features: Highly sensitive ETO measurement; High selectivity in presence of CO. Applications: Sterilization Processes; Safety and Process Control.\",\"zh\":\"Membrapor ETO\/CA-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-ca-20-ca5d759177.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b510469aca896eb263cf\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/M-10\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"2250 \u00b1 750 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Miniature Housing. Key features: Highly sensitive ETO measurement. Applications: Sterilization Processes; Safety and Process Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor ETO\/M-10 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-m-10-f155a80f5a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:63b4aa7e36725ae169c4\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/M-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"110 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Miniature Housing. Applications: Sterilization Processes; Safety and Process Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor ETO\/M-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-m-100-7f067c30b7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d02e3bdb82399f2aa334\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"ETO\/M-1000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"25 \u00b1 6 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"C2H4O Gas Sensor in Miniature Housing. Applications: Sterilization Processes; Safety and Process Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor ETO\/M-1000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-eto-m-1000-0ea03c5358.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:fae2d79d39b6315b523b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/C-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"23 \u00b1 8 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Applications: Safety and Process Control. highly sensitive.\",\"zh\":\"Membrapor H2\/C-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-c-2000-3af8bcbee1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:bea6a6b9acd66cf3e3d5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/C-20000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20000 ppm\",\"sensitivity\":\"6 \u00b1 4 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 8.4 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Key features: Measurement of 50% LEL for H2. Applications: Safety and Process Control.\",\"zh\":\"Membrapor H2\/C-20000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 20000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-c-20000-80f4c2300c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b4ffb708520c6974f279\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/C-40000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 40000 ppm\",\"sensitivity\":\"4 \u00b1 3 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 12.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Key features: Measurement of 100% LEL for H2. Applications: Safety and Process Control.\",\"zh\":\"Membrapor H2\/C-40000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 40000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-c-40000-098a4ba52c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3f2c11d2a690152c989d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/C-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"9 \u00b1 2 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 5.3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor H2\/C-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-c-5000-ce338a08a7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:cc7360283221a374ec2c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/CA-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"28 \u00b1 11 nA\/ppm 1)\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.8 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Key features: Highly selective H2 detection in presence of CO. Applications: Safety and Process Control; H2 Detection in H2\/CO-Mixtures; Medical Applications. highly selective.\",\"zh\":\"Membrapor H2\/CA-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-ca-1000-1218f20ff7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:566712a7d2b5016d0f30\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/CB-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"28 \u00b1 11 nA\/ppm 1)\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.8 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Key features: Highly selective H2 detection in presence of CO. Applications: Medical Applications; H2 Detection in H2\/CO-Mixtures. more gastight.\",\"zh\":\"Membrapor H2\/CB-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-cb-1000-d0a1525f99.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d553440691a90e3bdb64\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/CT-10000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"12 \u00b1 6 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 4.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"50 % to 95 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Key features: H2 monitoring in humid environments. Applications: Monitoring at High Humidity; Biogas Analyzer. for high humidity levels.\",\"zh\":\"Membrapor H2\/CT-10000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-ct-10000-9de4a1eeb7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5af79c74b004b4634572\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/CT-40000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 40000 ppm\",\"sensitivity\":\"4 \u00b1 3 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 12.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"50 % to 95 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Compact Housing. Key features: H2 monitoring in humid environments; Measurement of 100% LEL for H2. Applications: Monitoring at High Humidity; Biogas Analyzer. for high humidity levels.\",\"zh\":\"Membrapor H2\/CT-40000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 40000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-ct-40000-ebb42fdb78.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:df6a75e861ba38a001ba\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/M-1000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"25 \u00b1 10 nA\/ppm 1)\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Miniature Housing. Applications: Safety and Process Control; For Portable Devices. highly sensitive.\",\"zh\":\"Membrapor H2\/M-1000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-m-1000-9c29fdb704.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ca61a88368bf8ea3ef7d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/M-4000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 4000 ppm\",\"sensitivity\":\"10 \u00b1 6 nA\/ppm 1)\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 5.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Miniature Housing. Applications: Safety and Process Control; For Portable Devices.\",\"zh\":\"Membrapor H2\/M-4000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 4000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-m-4000-2ad5a591cc.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:79a922362cf6376f9ba0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/M-40000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 40000 ppm\",\"sensitivity\":\"5 \u00b1 3 nA\/ppm 1)\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 10.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Miniature Housing. Key features: Measurement of 100% LEL for H2. Applications: Safety and Process Control; For Portable Devices.\",\"zh\":\"Membrapor H2\/M-40000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 40000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-m-40000-b9d29febb6.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:059078482435a191cacf\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/S-10000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"6 \u00b1 4 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 8.4 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Slim Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor H2\/S-10000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-s-10000-s-3e8edd9f67.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:f085df7d33872f9fddd0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/S-2000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"20 \u00b1 5 nA\/ppm 1)\",\"responseTime\":\"< 45 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Slim Housing. Applications: Safety and Process Control. highly sensitive.\",\"zh\":\"Membrapor H2\/S-2000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-s-2000-s-fb4dc38ffd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ee46588003f1428ec142\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/SA-1000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"28 \u00b1 11 nA\/ppm 1)\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.8 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Slim Housing. Applications: Safety and Process Control; H2 Detection in H2\/CO-Mixtures. highly selective.\",\"zh\":\"Membrapor H2\/SA-1000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-sa-1000-s-9b556b7a3d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0f561a05dccf946adb10\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/SA-1000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"28 \u00b1 11 nA\/ppm 1)\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.8 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Standard Housing. Applications: Safety and Process Control; H2 Detection in H2\/CO-Mixtures; Medical Applications. highly selective.\",\"zh\":\"Membrapor H2\/SA-1000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-sa-1000-23db49b5c5.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:8ebebc7fdf80d38f44ad\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2\/VA-1000\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"27 \u00b1 12 nA\/ppm 1)\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.8 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2 Gas Sensor in Vantage Housing. Key features: Highly reliable and selective H2 detection; Replaceable Filter. Applications: Hydrogen Energy Storage; H2 Detection in H2\/CO-Mixtures; Medical Applications. highly selective.\",\"zh\":\"Membrapor H2\/VA-1000 \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2-va-1000-d4d3cc7462.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7eb2f997e677c7a00d1b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/CB-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"1100 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Compact Housing. Key features: Highly sensitive H2O2 measurement. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring. highly sensitive.\",\"zh\":\"Membrapor H2O2\/CB-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-cb-100-a1299e1d19.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3759d896d792c14997e0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/CB-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring.\",\"zh\":\"Membrapor H2O2\/CB-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-cb-2000-6334553df1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:9d49ffa7b0b217a26974\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/CB-500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"300 \u00b1 60 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.25 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring.\",\"zh\":\"Membrapor H2O2\/CB-500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-cb-500-ccd18b5c75.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5672d0160fdab02cf7da\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/CB-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"25 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring.\",\"zh\":\"Membrapor H2O2\/CB-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-cb-5000-31c0c3ecdc.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:47a521a78ebc21ba0ac9\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/MB-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"550 \u00b1 100 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Miniature Housing. Key features: Highly sensitive H2O2 measurement. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring. highly sensitive.\",\"zh\":\"Membrapor H2O2\/MB-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-mb-100-be524f735f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:8080b2646b0bbea37c2d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/MB-2000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring.\",\"zh\":\"Membrapor H2O2\/MB-2000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-mb-2000-cb1f21bc95.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:8f5a38cb664267fc879f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/MB-500\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"200 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.25 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring.\",\"zh\":\"Membrapor H2O2\/MB-500 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-mb-500-c19752e1f7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:c212651de07ee92e1672\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2O2\/MB-5000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"25 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2O2 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Sterilization Process; Disinfection monitoring.\",\"zh\":\"Membrapor H2O2\/MB-5000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2o2-mb-5000-7df3b140b1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ffd1205dee0f31ba73c6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/C-10\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"4500 \u00b1 1000 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Key features: Highly sensitive H2S measurement. Applications: Discontinuous Measurement; Air Quality Monitoring; Medical Applications. highest sensitivity.\",\"zh\":\"Membrapor H2S\/C-10 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-c-10-e2c9470d3d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7f9f8e494304344f1b4d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor H2S\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-c-1000-c0074b3c0a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3e3290fe4090653ef888\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"370 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Environmental Control.\",\"zh\":\"Membrapor H2S\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-c-200-6c865ca026.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:575eb7b965acf1eb5402\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/C-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor H2S\/C-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-c-2000-c8a7edd8a1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0353c0d36d25d65061cf\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/C-50\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"1700 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor H2S\/C-50 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-c-50-e0688ad427.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:bccd8885defa17268b04\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/C-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"25 \u00b1 6 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor H2S\/C-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-c-5000-c8fb9cd233.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:349396f07166b263e0b3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/CG-100-4E\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"540 \u00b1 110 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Key features: Increased gas tightness; H2S measurement in presence of H2. Applications: Discontinuous Measurement; Biogas Analyzer; H2-Compensated H2S Measurement. Hydrogen compensated.\",\"zh\":\"Membrapor H2S\/CG-100-4E \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-cg-100-4e-90ef19be19.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b55a3f6fad486cfc8643\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/CG-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"550 \u00b1 110 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Biogas Analyzer; Safety and Environmental Control. more gastight.\",\"zh\":\"Membrapor H2S\/CG-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-cg-100-00a60a4417.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2ac6a2e3dea18e3ed3c8\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/CG-10000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"2 years in air\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Biogas Analyzer; Safety and Process Control. more gastight.\",\"zh\":\"Membrapor H2S\/CG-10000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-cg-10000-dc46284e5b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:34267f066b0812652d0c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/CG-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 9 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Biogas Analyzer; Safety and Process Control. more gastight.\",\"zh\":\"Membrapor H2S\/CG-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-cg-2000-e56f7c5dfb.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d5d8ee93cc5fa2c45181\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/CG-5000-4E\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"25 \u00b1 6 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Biogas Analyzer; H2-Compensated H2S Measurement. Hydrogen compensated.\",\"zh\":\"Membrapor H2S\/CG-5000-4E \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-cg-5000-4e-6be8c6b05d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:948abad5903eaed0de54\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/CG-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"20 \u00b1 9 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Compact Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Biogas Analyzer; Safety and Process Control. more gastight.\",\"zh\":\"Membrapor H2S\/CG-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-cg-5000-010dfcabdf.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6f164c403399e887834b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/M-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"700 \u00b1 140 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; For Portable Gas Detectors.\",\"zh\":\"Membrapor H2S\/M-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-m-100-e516ba21c9.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:def32e1416ebed2740a3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/M-200-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"250 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor H2S\/M-200-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-m-200-2e-583bf72c8f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:1e15f502262ea3ba8aa6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/M-2000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; For Portable Gas Detectors.\",\"zh\":\"Membrapor H2S\/M-2000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-m-2000-cb3f2dddb5.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6562258a6cb85f6d8b5d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/M-50\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"1200 \u00b1 250 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor H2S\/M-50 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-m-50-da823b748e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:34d5063a6de42461ff26\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/M-500\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; For Portable Gas Detectors.\",\"zh\":\"Membrapor H2S\/M-500 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-m-500-24c302e0d2.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:91ecea235398741afb90\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-10-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"4000 \u00b1 1000 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Slim Housing. Applications: Discontinuous Measurement; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor H2S\/S-10-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-10-s-2eadd9dfa8.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:9744382e58cd33898e31\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-10000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 3.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Slim Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor H2S\/S-10000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-10000-s-bb0896cc91.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:184cbb1579772023fae3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-50-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"1700 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Slim Housing. Applications: Discontinuous Measurement; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor H2S\/S-50-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-50-s-e2724c772b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:c56f48523c943b8a3e2a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/SG-10000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 3.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Slim Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Biogas Analyzer; Safety and Environmental Control.\",\"zh\":\"Membrapor H2S\/SG-10000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-sg-10000-s-5fa8d27641.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:437eec08bbb1d50b8011\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/SG-200-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"370 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Slim Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Biogas Analyzer; Safety and Environmental Control. more gastight.\",\"zh\":\"Membrapor H2S\/SG-200-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-sg-200-s-ef12d657c1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:fd066be45242a62ecf3c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/SG-2000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 9 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Slim Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Biogas Analyzer; Safety and Environmental Control. more gastight.\",\"zh\":\"Membrapor H2S\/SG-2000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-sg-2000-s-3471a137d7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d70cceecc9e3c1b14eda\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/SG-50-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"1700 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Slim Housing. Key features: Increased gas tightness. Applications: Discontinuous Measurement; Safety and Environmental Control. more gastight.\",\"zh\":\"Membrapor H2S\/SG-50-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-sg-50-s-9e803623fa.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:efdb40dbef8549f81270\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-1000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Standard Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor H2S\/S-1000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-1000-6e51e0a3ad.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:618de467a87d65ecd5f0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-10000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"15 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 3.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Standard Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor H2S\/S-10000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-10000-82edba7f49.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:08a94de59de5c3e4b39f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-200\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"370 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Standard Housing. Applications: Discontinuous Measurement; Safety and Environmental Control.\",\"zh\":\"Membrapor H2S\/S-200 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-200-d3f2896538.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:25f48322256701fffcd4\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-50\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"1700 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Standard Housing. Applications: Discontinuous Measurement. highly sensitive.\",\"zh\":\"Membrapor H2S\/S-50 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-50-7046b0168f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0b90074748adc97f18b1\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"H2S\/S-5000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"25 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"H2S Gas Sensor in Standard Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor H2S\/S-5000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-h2s-s-5000-b325dcd768.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b5317cc83679c4c480dd\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCl\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"20 \u00b1 7 nA\/ppm\",\"responseTime\":\"< 40 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 5.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCl Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor HCl\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcl-c-1000-b3afdd43e4.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:8030730a6e2a2aaf5293\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCl\/C-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"450 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 30 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCl Gas Sensor in Compact Housing. Key features: Highly sensitive HCl measurement. Applications: Discontinuous Measurement; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor HCl\/C-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcl-c-20-a5236e29bd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e8855ea269bbaccc1a57\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCl\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"100 \u00b1 35 nA\/ppm\",\"responseTime\":\"< 30 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCl Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor HCl\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcl-c-200-4eba9f8c86.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ce86d8193a79a96861e2\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCl\/C-3000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 3000 ppm\",\"sensitivity\":\"15 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 40 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 6.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCl Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor HCl\/C-3000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 3000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcl-c-3000-02c2e0d074.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:03abba8f6f17fc8cb481\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCl\/M-20\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"400 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 40 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCl Gas Sensor in Miniature Housing. Key features: Highly sensitive HCl measurement. Applications: Discontinuous Measurement; Safety and Environmental Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor HCl\/M-20 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcl-m-20-75b1007898.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:215dbe88e3b341614ea5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCl\/M-200\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"80 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 1.5 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCl Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Safety and Environmental Control; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor HCl\/M-200 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcl-m-200-8cb5128596.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:f593d81020ee31a0d49a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCN\/C-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"600 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCN Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor HCN\/C-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcn-c-100-582d047c0f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b09a86d50762bbd99389\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HCN\/M-50\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"200 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HCN Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Safety and Environmental Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor HCN\/M-50 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hcn-m-50-4223bb7ba4.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5459e192124ed597cb77\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HF\/C-10\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"- 110 \u00b1 40 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HF Gas Sensor in Compact Housing. Key features: Long life HF sensor. Applications: Safety and Process Control.\",\"zh\":\"Membrapor HF\/C-10 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c1f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hf-c-10-2706623b39.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:cb490c425f0ee5d2fdef\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HF\/CI-10\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"- 600 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HF Gas Sensor in Compact Housing. Key features: Highly sensitive. Applications: Safety and Process Control. highly sensitive.\",\"zh\":\"Membrapor HF\/CI-10 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c1f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hf-ci-10-8f5965c398.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:452fb4d7e496f30c63d4\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HF\/M-10\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"- 110 \u00b1 40 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HF Gas Sensor in Miniature Housing. Key features: Long life HF sensor. Applications: Safety and Process Control; For Portable Gas Detectors. Measurement of Hydrofluoric Acid.\",\"zh\":\"Membrapor HF\/M-10 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c1f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hf-m-10-2f014d5dfe.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:81930dd1ebec75e5e4b3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"HF\/MI-10\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10 ppm\",\"sensitivity\":\"- 500 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"HF Gas Sensor in Miniature Housing. Key features: Highly sensitive. Applications: Safety and Process Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor HF\/MI-10 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c1f\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 10 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-hf-mi-10-1c4bfc627f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:385acbc039c02ba9e0f3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/CR-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"25 \u00b1 8 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Compact Housing. Applications: Leak Detection; Discontinuous Measurement; Safety and Environmental Control. short response time.\",\"zh\":\"Membrapor NH3\/CR-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-cr-1000-611fd504bf.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0363cd8c10a746f658cb\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/CR-10000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"2.0 \u00b1 0.5 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 20.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor NH3\/CR-10000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-cr-10000-4e2f1681c1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ec6e13326cc22164c251\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/CR-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"112 \u00b1 40 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Compact Housing. Applications: Leak Detection; Discontinuous Measurement; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor NH3\/CR-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-cr-200-520841d784.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:aa334c9bd3359a5b851d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/CR-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"7 \u00b1 2 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 8.3 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor NH3\/CR-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-cr-5000-a0a3edd29b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:947c6398bd0d7e348b2a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-100-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 3.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Leak Detection; Discontinuous Measurement; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor NH3\/MR-100-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-100-2e-fc98b26709.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:dbb07ecf9e85d890a350\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"110 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Leak Detection; Discontinuous Measurement; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor NH3\/MR-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-100-98e8deb23d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:fd62c9567b216176cd29\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-1000-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"19 \u00b1 7 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.6 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Leak Detection; Discontinuous Measurement; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor NH3\/MR-1000-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-1000-2e-38f8b88636.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:52864f1f067260ed39b8\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-1000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"25 \u00b1 8 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Leak Detection; Discontinuous Measurement; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor NH3\/MR-1000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-1000-b86587028c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:92aabe3d8192f284127c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-10000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"2 \u00b1 0 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 20.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Spot Measurement; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor NH3\/MR-10000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-10000-c1acbfbc5e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:47fbde433f0cc2829cfd\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-2000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"12 \u00b1 4 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 4.2 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Spot Measurement; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor NH3\/MR-2000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-2000-9a4c142eaa.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:592730e042eea8d2c395\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-500\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"35 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.4 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Leak Detection; Discontinuous Measurement; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor NH3\/MR-500 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-500-e7dc647e10.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6c91fc49102dc0b5e2b6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/MR-5000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"5 \u00b1 2 nA\/ppm\",\"responseTime\":\"< 35 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 10.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Spot Measurement; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor NH3\/MR-5000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-mr-5000-91d1514627.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a0c9aa19f2d9a7afc7a7\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/SR-1000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"25 \u00b1 8 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Slim Housing. Applications: Leak Detection; Discontinuous Measurement; Safety and Environmental Control.\",\"zh\":\"Membrapor NH3\/SR-1000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-sr-1000-s-9a2f8cc984.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3beb46970e267183ad37\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/SR-200-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"90 \u00b1 18 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.6 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Slim Housing. Applications: Leak Detection; Discontinuous Measurement; Safety and Environmental Control.\",\"zh\":\"Membrapor NH3\/SR-200-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-sr-200-s-3c3aa68b4d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0ed7e413121a10dc18af\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/SR-1000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"25 \u00b1 8 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Standard Housing. Applications: Leak Detection; Discontinuous Measurement; Safety and Environmental Control.\",\"zh\":\"Membrapor NH3\/SR-1000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-sr-1000-050c970e3a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:333ef8ef67950c39f00b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NH3\/SR-200\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"90 \u00b1 18 nA\/ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.6 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NH3 Gas Sensor in Standard Housing. Applications: Leak Detection; Discontinuous Measurement; Safety and Environmental Control.\",\"zh\":\"Membrapor NH3\/SR-200 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-nh3-sr-200-702fa24f7b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:62ce47e1b69957763b11\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/C-1\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"3000 \u00b1 1200 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing 2)\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Compact Housing. Key features: Highly sensitive NO measurement. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highest sensitivity.\",\"zh\":\"Membrapor NO\/C-1 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-c-1-238bff04f1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:cda6dfff9a9b5a7b3876\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/C-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"550 \u00b1 110 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor NO\/C-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-c-100-7bccaa98f5.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6a933a29344a308da482\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/C-25\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 25 ppm\",\"sensitivity\":\"2000 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor NO\/C-25 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 25 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-c-25-2f7eec084f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:9d0c0f25a7507ab0fc84\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/CF-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"400 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor NO\/CF-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-cf-100-c8835754ea.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0c1aca3a780460f2fcaa\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/CF-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3 years in air\"},\"description\":{\"en\":\"NO Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor NO\/CF-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-cf-2000-62001ea406.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:15ad4be8b2df6559ef3b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/CL-1-4E\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"3000 \u00b1 1200 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Compact Housing. Key features: Lowest detection limit; Temperature compensated baseline. Applications: Continuous Air Quality Monitoring; Environmental Control. for lowest gas concentrations.\",\"zh\":\"Membrapor NO\/CL-1-4E \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-cl-1-4e-aee34f6fb8.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ab003b2c4af445eb418c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/M-1000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 25 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Miniature Housing. Applications: Emission Monitoring; Safety and Environmental Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor NO\/M-1000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-m-1000-e703780c94.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6c10bf5c967552e7021e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/M-25\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 25 ppm\",\"sensitivity\":\"1000 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor NO\/M-25 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 25 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-m-25-5c6663f0b4.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:07e07ecedac5cecd7d31\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/M-250\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 250 ppm\",\"sensitivity\":\"360 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor NO\/M-250 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 250 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-m-250-950476933e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d261329af52c0073ba05\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/S-100-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"550 \u00b1 110 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor NO\/S-100-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-s-100-s-8ef970753b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:007bd30f814045998c3f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/S-25-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 25 ppm\",\"sensitivity\":\"2000 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor NO\/S-25-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 25 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-s-25-s-a174422972.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b097ba217c8f00823923\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/SF-1000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"200 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Slim Housing. Applications: Emission Monitoring; Safety and Environmental Control. Emission Monitoring.\",\"zh\":\"Membrapor NO\/SF-1000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-sf-1000-s-d8ea318d81.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d3dcfd0c5fd140ea7bd5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/SF-200-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"275 \u00b1 55 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor NO\/SF-200-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-sf-200-s-d6e956cc89.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7dbefe569bee2c3cb6b0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/SF-5000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"40 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor NO\/SF-5000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-sf-5000-s-020f20eb08.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a610aa278e712818eb6d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/SGF-2000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Slim Housing. Key features: Increased gas tightness. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor NO\/SGF-2000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-sgf-2000-s-9efe8c62a1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:75cc851e03886793721c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/S-100\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"550 \u00b1 110 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor NO\/S-100 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-s-100-35f91a64d8.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0cc847e556c7396c1611\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/S-25\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 25 ppm\",\"sensitivity\":\"2000 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor NO\/S-25 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 25 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-s-25-936e1b488a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7ab333bc314c17fd24d0\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/SF-100\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"400 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor NO\/SF-100 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-sf-100-023fa0b975.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:16233fa090493deec506\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/SF-1000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"200 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Standard Housing. Applications: Emission Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor NO\/SF-1000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-sf-1000-fcba796e04.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:51d1b77ac6d3998756da\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/SF-5000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"40 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Standard Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor NO\/SF-5000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-sf-5000-468cfc6c75.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:89f6ad44b27ee769220e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/VF-1000-4E\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 36 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Vantage Housing. Key features: Replaceable Filter; Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor NO\/VF-1000-4E \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-vf-1000-4e-2c7e7952b5.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:27fae8fe0b74f4922652\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO\/VF-300-4E\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 300 ppm\",\"sensitivity\":\"500 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 36 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO Gas Sensor in Vantage Housing. Key features: Replaceable Filter; Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor NO\/VF-300-4E \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 300 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no-vf-300-4e-ee87d114be.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b6e643ae28fb3834bafb\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/C-1\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"- 2500 \u00b1 1000 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Compact Housing. Key features: Highly sensitive NO2 measurements. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor NO2\/C-1 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-c-1-e4115aad56.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:00f77c0313c3123177fe\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/C-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"- 1100 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor NO2\/C-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-c-20-5263cf132f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:796ee303348101f599bf\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/C-500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"- 370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor NO2\/C-500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-c-500-2b89be7621.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b0c76d1d06bc3de18f4e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/CA-2\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2 ppm\",\"sensitivity\":\"- 650 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Compact Housing. Key features: Highly sensitive and selective NO2 detection in presence of O3. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive, with O3 filter.\",\"zh\":\"Membrapor NO2\/CA-2 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 2 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-ca-2-9b0df6b00a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a2f82c0ae98a7b1b54d9\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/M-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"- 120 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor NO2\/M-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-m-100-6e7ab19c9d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:44abbb3283313805c9b3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/M-20\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"- 750 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor NO2\/M-20 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-m-20-c45563ef34.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:11c7466c695b64c8b0b9\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/M-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"- 300 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Miniature Housing. Applications: Air Quality Monitoring; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor NO2\/M-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-m-2e-e02d8ca7cd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2fbc0d70a842b034b7ca\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/M-2EG\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"300 \u00b1 70 nA\/ppm 1)\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Miniature Housing. Applications: Air Quality Monitoring; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor NO2\/M-2EG \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-m-2eg-4b3b76b043.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ebc2a5ab22832e2fd605\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/M-500\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"- 100 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Miniature Housing. Applications: Emission Monitoring; For Portable Gas Detectors.\",\"zh\":\"Membrapor NO2\/M-500 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-m-500-971e58ba12.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a91aa06896ee504e9237\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/S-1000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"- 170 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor NO2\/S-1000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-s-1000-s-c7f6bc1b37.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:10e78fb5c10b012edb87\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/S-20-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"- 1100 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor NO2\/S-20-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-s-20-s-418aa5f029.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2a2acbb30b3df3dc29e7\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/S-5000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"- 40 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor NO2\/S-5000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-s-5000-s-ae81dce0f7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:79092ce00289feb416fc\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/SG-500-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"- 370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Slim Housing. Key features: Increased gas tightness. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor NO2\/SG-500-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-sg-500-s-779404d421.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:4efbf1d96e9290fb8050\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/S-100\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"- 370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Standard Housing. Applications: Safety and Environmental Control.\",\"zh\":\"Membrapor NO2\/S-100 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-s-100-d9f562e741.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2b3466a42e1f71f7cf4d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/S-1000\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"- 170 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Standard Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor NO2\/S-1000 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-s-1000-eac790dc3f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:55e967da326ded5037d4\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"NO2\/V-200\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"- 370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"NO2 Gas Sensor in Vantage Housing. Key features: Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor NO2\/V-200 \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-no2-v-200-f05fc255c8.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:dda867e069eb7f3bca0a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O2\/M-1\",\"seriesKey\":\"membrapor:oxygen-sensors-0a8104eb\",\"series\":{\"en\":\"Oxygen Sensors\",\"zh\":\"\u6c27\u6c14\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 %\",\"sensitivity\":\"1300 \u00b1 300 \u03bcA\/%\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 50.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"5+ years in air\"},\"description\":{\"en\":\"O2 Gas Sensor in Miniature Housing. Key features: Fast equilibration time; Long-Life sensor with no consumable parts and lead-free (RoHS compliant). Applications: Trace oxygen measurements; Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive, RoHS.\",\"zh\":\"Membrapor O2\/M-1 \u662f\u4e00\u6b3e\u6c27\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 1 %\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-oxygen-sensors-0a15ba867b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o2-m-1-11f2084673.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:c5b320dfd88601194c7f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O2\/M-100\",\"seriesKey\":\"membrapor:oxygen-sensors-0a8104eb\",\"series\":{\"en\":\"Oxygen Sensors\",\"zh\":\"\u6c27\u6c14\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 30 %\",\"sensitivity\":\"80 \u00b1 24 \u03bcA\/%\",\"responseTime\":\"< 8 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 500.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"5+ years in air\"},\"description\":{\"en\":\"O2 Gas Sensor in Miniature Housing. Key features: Fast equilibration time; Long-Life sensor with no consumable parts and lead-free (RoHS compliant). Applications: Oxygen Monitoring in Diffusion Mode; Continuous Air Quality Monitoring; Safety and Environmental Control. short response time, RoHS.\",\"zh\":\"Membrapor O2\/M-100 \u662f\u4e00\u6b3e\u6c27\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 30 %\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-oxygen-sensors-0a15ba867b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o2-m-100-9edd64d628.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ac4124a584e1221f5540\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O2\/MP-100\",\"seriesKey\":\"membrapor:oxygen-sensors-0a8104eb\",\"series\":{\"en\":\"Oxygen Sensors\",\"zh\":\"\u6c27\u6c14\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 30 %\",\"sensitivity\":\"60 \u00b1 20 \u03bcA\/%\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 500.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"5+ years in air\"},\"description\":{\"en\":\"O2 Gas Sensor in Miniature Housing. Key features: Designed to be operated with pumps; Long-Life sensor with no consumable parts and lead-free (RoHS compliant). Applications: Oxygen Monitoring in Diffusion Mode; Continuous Air Quality Monitoring; Safety and Environmental Control. for pump mode, RoHS.\",\"zh\":\"Membrapor O2\/MP-100 \u662f\u4e00\u6b3e\u6c27\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 30 %\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-oxygen-sensors-0a15ba867b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o2-mp-100-1600b81a88.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7d5ef20a53ed3b0c5f34\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O2\/MT-100\",\"seriesKey\":\"membrapor:oxygen-sensors-0a8104eb\",\"series\":{\"en\":\"Oxygen Sensors\",\"zh\":\"\u6c27\u6c14\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 30 %\",\"sensitivity\":\"80 \u00b1 24 \u03bcA\/%\",\"responseTime\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 500.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"50 % to 95 % RH non-condensing\",\"lifetime\":\"5+ years in air\"},\"description\":{\"en\":\"O2 Gas Sensor in Miniature Housing. Key features: For high humidity environments; Long-Life sensor with no consumable parts and lead-free (RoHS compliant). Applications: Oxygen Monitoring in Diffusion Mode; Continuous Air Quality Monitoring; Safety and Environmental Control. at high humidity, RoHS.\",\"zh\":\"Membrapor O2\/MT-100 \u662f\u4e00\u6b3e\u6c27\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\uff0c\u91cf\u7a0b\u4e3a 0 - 30 %\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-oxygen-sensors-0a15ba867b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o2-mt-100-170eb77e23.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6543f3cab826844b4d0e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/C-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"- 650 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor O3\/C-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-c-100-b868bee0e2.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:bfafd3ed30ff8dc855e6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"- 170 \u00b1 30 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor O3\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-c-1000-e09189dc61.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b6d970f02449499c9978\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"- 400 \u00b1 130 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor O3\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-c-200-f3d683a3dc.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7c955aa52f8cf604f9a7\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/C-5\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5 ppm\",\"sensitivity\":\"- 1500 \u00b1 500 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Compact Housing. Key features: Highly sensitive O3 measurements. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor O3\/C-5 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 5 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-c-5-be233cb0e2.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:528c4a2c81d0666341d5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/C-5000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5000 ppm\",\"sensitivity\":\"- 30 \u00b1 10 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 10.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Compact Housing. Applications: Safety and Process Control.\",\"zh\":\"Membrapor O3\/C-5000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 5000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-c-5000-0c28d21ac3.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:f630b0d674741548086f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/M-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"- 400 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Miniature Housing. Applications: Safety and Process Control; For Portable Gas Detectors.\",\"zh\":\"Membrapor O3\/M-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-m-100-21a4bee1e7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:fd00ff9435407fae5277\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/M-5\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5 ppm\",\"sensitivity\":\"- 1000 \u00b1 350 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Miniature Housing. Key features: Highly sensitive O3 measurements. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor O3\/M-5 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 5 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-m-5-8e7d597360.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:deca822f1427a318c7e5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"O3\/S-5-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5 ppm\",\"sensitivity\":\"- 1500 \u00b1 500 nA\/ppm\",\"responseTime\":\"< 60 s (T80)\",\"responseLabel\":{\"en\":\"Response Time T80\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T80\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"O3 Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control.\",\"zh\":\"Membrapor O3\/S-5-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\uff0c\u91cf\u7a0b\u4e3a 0 - 5 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-o3-s-5-s-fdef013e43.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b9c40164ae26361f4a17\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"100 \u00b1 25 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor PH3\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-c-1000-0b2c79c0f6.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:61c8f354bd2c0ab24f7c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/C-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"70 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor PH3\/C-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-c-2000-1fc0ebf060.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:378f56671dfa0e79c9a3\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/C-4000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 4000 ppm\",\"sensitivity\":\"30 \u00b1 8 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control. short response time.\",\"zh\":\"Membrapor PH3\/C-4000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 4000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-c-4000-62caae30bd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:2def6552913ebca45740\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/C-5\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5 ppm\",\"sensitivity\":\"4400 \u00b1 1600 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Compact Housing. Key features: Highly sensitive PH3 measurements. Applications: Discontinuous Measurement; Safety and Process Control. highly sensitive.\",\"zh\":\"Membrapor PH3\/C-5 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-c-5-053c85e833.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:009e523fd34f6878e9e7\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/M-20\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"1000 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Safety and Process Control; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor PH3\/M-20 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-m-20-b9e974c15a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5832943400beebd5fe81\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/M-200\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"300 \u00b1 60 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Safety and Process Control; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor PH3\/M-200 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-m-200-fb11cbd530.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:39793a7d15d8c45ae0ea\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/M-2000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"50 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Safety and Process Control; For Portable Gas Detectors. short response time.\",\"zh\":\"Membrapor PH3\/M-2000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-m-2000-35c39fea6d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b429d31a48b03c2fbcf1\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"PH3\/M-5\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 5 ppm\",\"sensitivity\":\"3500 \u00b1 1000 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"PH3 Gas Sensor in Miniature Housing. Key features: Highly sensitive PH3 measurements. Applications: Discontinuous Measurement; Safety and Process Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor PH3\/M-5 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\uff0c\u91cf\u7a0b\u4e3a 0 - 5 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-ph3-m-5-4a1fbb101b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ae6455c91e6f1a1a282f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Alc\/C-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"R3COH\",\"gasName\":{\"en\":\"Alcohols\",\"zh\":\"\u9187\u7c7b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"Methanol: 1600 \u00b1 600 nA\/ppm Ethanol: 1400 \u00b1 600 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"R3COH Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Process Control. Methanol \/ Ethanol Measurement.\",\"zh\":\"Membrapor Alc\/C-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u9187\u7c7b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-alc-c-100-5f8ff9fba1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6cc7bc01f0352af96518\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Alc\/C-1000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"R3COH\",\"gasName\":{\"en\":\"Alcohols\",\"zh\":\"\u9187\u7c7b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"Methanol: 120 \u00b1 20 nA\/ppm Ethanol: 100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"R3COH Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Process Control. Methanol \/ Ethanol Measurement.\",\"zh\":\"Membrapor Alc\/C-1000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u9187\u7c7b\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-alc-c-1000-17f39dedc0.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:12953da67bbf3912fdbd\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Alc\/M-200\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"R3COH\",\"gasName\":{\"en\":\"Alcohols\",\"zh\":\"\u9187\u7c7b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"Methanol: 1100 \u00b1 400 nA\/ppm Ethanol: 1000 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"R3COH Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; Safety and Process Control. Methanol \/ Ethanol Measurement.\",\"zh\":\"Membrapor Alc\/M-200 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u9187\u7c7b\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-alc-m-200-dbb010ada5.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3088be985e4310861a6a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Acid\/C-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"RCOOH\",\"gasName\":{\"en\":\"Organic Acids\",\"zh\":\"\u6709\u673a\u9178\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"Formic Acid: - 90 \u00b1 60 nA\/ppm Acetic Acid: - 70 \u00b1 40 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"RCOOH Gas Sensor in Compact Housing. Key features: Selective Measurement of Organic Acids. Applications: Safety and Process Control; Continuous Air Quality Monitoring. Measurment of organic acids.\",\"zh\":\"Membrapor Acid\/C-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6709\u673a\u9178\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-acid-c-100-885d95d23c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:95e115e9dcbdf5aa05f6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"Acid\/M-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"RCOOH\",\"gasName\":{\"en\":\"Organic Acids\",\"zh\":\"\u6709\u673a\u9178\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"Formic Acid: - 90 \u00b1 60 nA\/ppm Acetic Acid: - 70 \u00b1 40 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-10 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"RCOOH Gas Sensor in Miniature Housing. Key features: Selective Measurement of Organic Acids. Applications: Safety and Process Control; Continuous Air Quality Monitoring; For Portable Gas Detectors. Measurement of organic acids.\",\"zh\":\"Membrapor Acid\/M-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6709\u673a\u9178\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-acid-m-100-8f594a940f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:4a224a33708c62bfd32f\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SiH4\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"300 \u00b1 100 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SiH4 Gas Sensor in Compact Housing. Applications: Discontinuous Measurement; Safety and Process Control.\",\"zh\":\"Membrapor SiH4\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7845\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-sih4-c-200-cf9d1adae1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:67a35f9129446fc2b551\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SiH4\/C-50\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"1200 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SiH4 Gas Sensor in Compact Housing. Key features: Highly sensitive SiH4 measurement. Applications: Discontinuous Measurement; Safety and Process Control. highly sensitive.\",\"zh\":\"Membrapor SiH4\/C-50 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7845\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-sih4-c-50-1ca9259546.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b74ec175d6b60aa65ef9\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SiH4\/M-50\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 ppm\",\"sensitivity\":\"660 \u00b1 220 nA\/ppm\",\"responseTime\":\"< 60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SiH4 Gas Sensor in Miniature Housing. Applications: Discontinuous Measurement; Safety and Process Control; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor SiH4\/M-50 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7845\u70f7\uff0c\u91cf\u7a0b\u4e3a 0 - 50 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-sih4-m-50-590df763a0.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:d6dfa7f9ab743b399c14\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/C-1\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1 ppm\",\"sensitivity\":\"5000 \u00b1 1500 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Key features: Highly sensitive SO2 measurements. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor SO2\/C-1 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 1 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-c-1-14656957f4.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:34f96338b6265eccb110\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/C-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Safety, Process and Environmental Control.\",\"zh\":\"Membrapor SO2\/C-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-c-100-44c6f15b4c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a0a85addedab8749fafd\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/C-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"1000 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor SO2\/C-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-c-20-f30c36d83a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ded0ceb5daf7f316a768\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/C-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor SO2\/C-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-c-2000-9ad25f194d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:dfa4dc4a559a3dd5a1a6\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/C-500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"280 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor SO2\/C-500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-c-500-b55b50b389.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:ea3c2c8878a564c9d983\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/CF-100\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor SO2\/CF-100 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-cf-100-0ed9e45a09.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:4c50c52d081d9046e944\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/CF-10000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"20 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. with filter.\",\"zh\":\"Membrapor SO2\/CF-10000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-cf-10000-db495d3284.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:fc38a30c09d41774d51e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/CF-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"550 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive, mit Filter.\",\"zh\":\"Membrapor SO2\/CF-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-cf-20-55f647dba1.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:cce9fadd739707c17b82\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/CF-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor SO2\/CF-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-cf-2000-5b8389d64e.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:984d8537d2b153924c01\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/CF-500\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500 ppm\",\"sensitivity\":\"280 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Compact Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. with filter.\",\"zh\":\"Membrapor SO2\/CF-500 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 500 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-cf-500-fb7d83a065.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:3ab3b790443391b3f729\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/M-100-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"300 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor SO2\/M-100-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-m-100-2e-fc6f809766.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6700e6aef81503bfd48d\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/M-20\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"500 \u00b1 90 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor SO2\/M-20 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-m-20-180738c50d.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:446c8ff8b57992c7c657\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/M-2E\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"450 \u00b1 80 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Safety and Environmental Control; For Portable Gas Detectors. 2-electrodes sensor.\",\"zh\":\"Membrapor SO2\/M-2E \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-m-2e-6aabc8fa7f.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:0d0713268aeaece6eb4c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/MF-100\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor SO2\/MF-100 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-mf-100-290c2e9ae7.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e24f7c6cdb743fe0e5ee\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/MF-1000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000 ppm\",\"sensitivity\":\"50 \u00b1 15 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 1.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Emission Monitoring; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor SO2\/MF-1000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 1000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-mf-1000-7d9fcf6fe9.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7efca43053067ab5eb8b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/MF-20\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"500 \u00b1 150 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Continuous Air Quality Monitoring; For Portable Gas Detectors. highly sensitive, with filter.\",\"zh\":\"Membrapor SO2\/MF-20 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-mf-20-7ed38d86ee.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:139ee77794bda2a2eb56\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/MF-200\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"300 \u00b1 60 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Emission Monitoring; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor SO2\/MF-200 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-mf-200-52564ed3aa.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:4fbf6933a6b45816478c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/MF-2000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"25 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Miniature Housing. Applications: Emission Monitoring; For Portable Gas Detectors. with filter.\",\"zh\":\"Membrapor SO2\/MF-2000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-mf-2000-dabf4dd2aa.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e256b6896a2b4fad7f9e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/S-20-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"1000 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor SO2\/S-20-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-s-20-s-6978b100dd.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:4f513e63e7e63af87be2\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/S-2000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 2.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor SO2\/S-2000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-s-2000-s-6cd54a3847.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:4b1d071d9cb0a45014cd\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/SF-100-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Slim Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor SO2\/SF-100-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-sf-100-s-49f8683a68.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:a5fd294de04afef67d10\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/SF-10000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"20 \u00b1 5 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 4.0 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor SO2\/SF-10000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-sf-10000-s-9a55604ea3.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:26645776e917a125c445\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/SF-400-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 400 ppm\",\"sensitivity\":\"200 \u00b1 50 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor SO2\/SF-400-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 400 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-sf-400-s-1c41e5ad2a.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:6dbd1abbca3a4de1ce1b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/SGF-2000-S\",\"seriesKey\":\"membrapor:slim-gas-sensors-ab11493e\",\"series\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Slim Housing. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring. Emission Monitoring.\",\"zh\":\"Membrapor SO2\/SGF-2000-S \u662f\u4e00\u6b3e\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-slim-gas-sensors-38d722cbe6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-sgf-2000-s-d0694aa066.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:4d75c7212aa1d96f3c24\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/S-100\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Standard Housing. Applications: Safety, Process and Environmental Control.\",\"zh\":\"Membrapor SO2\/S-100 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-s-100-c0bf1dadab.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:7784fe8a361836feeb4e\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/S-20\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"1000 \u00b1 300 nA\/ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor SO2\/S-20 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-s-20-deea4df231.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:5221fb02235e62fe847c\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/SF-100\",\"seriesKey\":\"membrapor:standard-gas-sensors-b03c2f91\",\"series\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100 ppm\",\"sensitivity\":\"370 \u00b1 70 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-20 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Standard Housing. Applications: Continuous Air Quality Monitoring; Safety and Environmental Control. with filter.\",\"zh\":\"Membrapor SO2\/SF-100 \u662f\u4e00\u6b3e\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 100 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-standard-gas-sensors-ac05e05380.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-sf-100-04a7eaad69.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:68b50ff385f001a4757b\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/V-2000\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Vantage Housing. Key features: Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor SO2\/V-2000 \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-v-2000-98cca91c38.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e15442d8f35e9dce5289\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"SO2\/VF-2000\",\"seriesKey\":\"membrapor:vantage-gas-sensors-1133c452\",\"series\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"100 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"-40 \u00b0C to 60 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"SO2 Gas Sensor in Vantage Housing. Key features: Replaceable Filter; Operable in Harsh Conditions with Temperatures up to 60\u00b0C. Applications: Stack\/ Flue Gas Monitoring; Emission Monitoring.\",\"zh\":\"Membrapor SO2\/VF-2000 \u662f\u4e00\u6b3eVantage \u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-vantage-gas-sensors-8ebc8f3534.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-so2-vf-2000-3232f76d7b.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:119e2cbbfe76f67476a5\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"VOC\/C-10000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compound\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10000 ppm\",\"sensitivity\":\"Alcohols Isopropanol: 13 \u00b1 3 nA\/ppm Methanol: 16 \u00b1 4 nA\/ppm Ethanol: 14 \u00b1 4 nA\/ppm Aromatic Hydrocarbons Xylene (isomeric mixture): 2.2 \u00b1 0.6 nA\/ppm Toluene: 0.6 \u00b1 0.2 nA\/ppm Benzene: None Organic Acids Formic acid: 5 \u00b1 2 nA\/ppm Unsaturated Hydrocarbons Isobutylene (Reference): 20 \u00b1 5 nA\/ppm Ethylene: 28 \u00b1 8 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 6.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"10000. Key features: Long-life VOC sensor; No replacement of sensor components. Applications: Safety and Process Control.\",\"zh\":\"Membrapor VOC\/C-10000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\uff0c\u91cf\u7a0b\u4e3a 0 - 10000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-voc-c-10000-931f4af426.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:86e85640ef2355f2fb0a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"VOC\/C-20\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compound\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"Alcohols Isopropanol: 1200 \u00b1 350 nA\/ppm Methanol: 1450 \u00b1 400 nA\/ppm Ethanol: 1300 \u00b1 350 nA\/ppm Aldehydes and Ketones Formaldehyde: 4000 \u00b1 500 nA\/ppm Acetone: 350 \u00b1 200 nA\/ppm Aromatic Hydrocarbons Xylene (isomeric mixture): 200 \u00b1 60 nA\/ppm Toluene: 60 \u00b1 20 nA\/ppm Benzene: None Organic acids Formic acid: 1500 \u00b1 200 nA\/ppm Acetic acid: 30 \u00b1 15 nA\/ppm Commercial vinegar1: 930 \u00b1 900 nA\/ppm Unsaturated Hydrocarbons Isobutylene (Reference): 1800 \u00b1 400 nA\/ppm Ethylene: 1800 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"VOC Gas Sensor in Compact Housing. Key features: Long-life VOC sensor; No replacement of sensor components. Applications: Emission Monitoring; Safety and Process Control; Safety and Environmental Control. highly sensitive.\",\"zh\":\"Membrapor VOC\/C-20 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-voc-c-20-83fdc88b66.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:824dc8823bd281c08373\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"VOC\/C-200\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compound\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 200 ppm\",\"sensitivity\":\"Alcohols Isopropanol: 340 \u00b1 60 nA\/ppm Methanol: 400 \u00b1 80 nA\/ppm Ethanol: 360 \u00b1 60 nA\/ppm Aromatic Hydrocarbons Xylene (isomeric mixture): 55 \u00b1 15 nA\/ppm Toluene: 16 \u00b1 6 nA\/ppm Benzene: None Organic Acids Formic acid: 500 \u00b1 200 nA\/ppm Unsaturated Hydrocarbons Isobutylene (Reference): 500 \u00b1 200 nA\/ppm Ethylene: 580 \u00b1 200 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"VOC Gas Sensor in Compact Housing. Key features: Long-life VOC sensor; No replacement of sensor components. Applications: Emission Monitoring; Safety and Process Control; Safety and Environmental Control.\",\"zh\":\"Membrapor VOC\/C-200 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\uff0c\u91cf\u7a0b\u4e3a 0 - 200 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-voc-c-200-986a8b8654.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:b9ac12d9330f207eafee\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"VOC\/C-2000\",\"seriesKey\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"series\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compound\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"Alcohols Isopropanol: 130 \u00b1 30 nA\/ppm Methanol: 160 \u00b1 40 nA\/ppm Ethanol: 140\u00b1 40 nA\/ppm Aromatic Hydrocarbons Xylene (isomeric mixture): 22 \u00b1 6 nA\/ppm Toluene: 6 \u00b1 2 nA\/ppm Benzene: None Organic Acids Formic acid: 200 \u00b1 50 nA\/ppm Unsaturated Hydrocarbons Isobutylene (Reference): 200 \u00b1 50 nA\/ppm Ethylene: 230 \u00b1 60 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.6 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"2000. Key features: Long-life VOC sensor; No replacement of sensor components. Applications: Safety and Process Control.\",\"zh\":\"Membrapor VOC\/C-2000 \u662f\u4e00\u6b3e\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-compact-gas-sensors-e14f419a57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-voc-c-2000-42b3e86d47.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:799e84185eb79e90fb0a\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"VOC\/M-20\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compound\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20 ppm\",\"sensitivity\":\"Alcohols Isopropanol: 1100 \u00b1 300 nA\/ppm Methanol: 1350 \u00b1 400 nA\/ppm Ethanol: 1200 \u00b1 350 nA\/ppm Aldehydes and Ketones Formaldehyde: 3500 \u00b1 500 nA\/ppm Acetone: 280 \u00b1 200 nA\/ppm Aromatic Hydrocarbons Xylene (isomeric mixture): 180 \u00b1 60 nA\/ppm Toluene: 55 \u00b1 15 nA\/ppm Benzene: None Organic acids Formic acid: 1200 \u00b1 200 nA\/ppm Acetic acid: 25 \u00b1 15 nA\/ppm Commercial vinegar1: 900 \u00b1 850 nA\/ppm Unsaturated Hydrocarbons Isobutylene (Reference): 1600 \u00b1 400 nA\/ppm Ethylene: 1400 \u00b1 400 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"VOC Gas Sensor in Miniature Housing. Applications: Emission Monitoring; For Portable Gas Detectors. highly sensitive.\",\"zh\":\"Membrapor VOC\/M-20 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\uff0c\u91cf\u7a0b\u4e3a 0 - 20 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-voc-m-20-8de970338c.pdf\",\"match\":\"exact\"}]},{\"id\":\"membrapor:e17cd860d8a151183862\",\"brandKey\":\"membrapor\",\"brandName\":\"Membrapor\",\"model\":\"VOC\/M-2000\",\"seriesKey\":\"membrapor:miniature-gas-sensors-b5b95407\",\"series\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compound\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000 ppm\",\"sensitivity\":\"Alcohols Isopropanol: 45 \u00b1 10 nA\/ppm Methanol: 55 \u00b1 10 nA\/ppm Ethanol: 50 \u00b1 10 nA\/ppm Aromatic Hydrocarbons Xylene (isomeric mixture): 8 \u00b1 4 nA\/ppm Toluene: 2 \u00b1 1 nA\/ppm Benzene: None Organic Acids Formic acid: 70 \u00b1 20 nA\/ppm Unsaturated Hydrocarbons Isobutylene (Reference): 70 \u00b1 20 nA\/ppm Ethylene: 80 \u00b1 20 nA\/ppm\",\"responseTime\":\"< 100 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"< 3.0 ppm\",\"temperature\":\"-40 \u00b0C to 50 \u00b0C\",\"humidity\":\"15 % to 90 % RH non-condensing\",\"lifetime\":\"3-5 years in air, application based, see MEM1\"},\"description\":{\"en\":\"2000. Key features: Long-life VOC sensor; No replacement of sensor components. Applications: Emission Monitoring; For Portable Gas Detectors.\",\"zh\":\"Membrapor VOC\/M-2000 \u662f\u4e00\u6b3e\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\uff0c\u91cf\u7a0b\u4e3a 0 - 2000 ppm\u3002\u68c0\u6d4b\u539f\u7406\u4e3a\u7535\u5316\u5b66\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/images\/membrapor-miniature-gas-sensors-b1bacde707.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/membrapor\/documents\/membrapor-voc-m-2000-3bf37c7589.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:b926db3f5fa33632687f\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"IRM-AT\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"0 \u2013 2.5% vol CH4 (high-accuracy leak range); 0 - 100% vol CH4 (wide-range process)\",\"sensitivity\":\"\",\"responseTime\":\"< 40 s at 20\u00b0C\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2.5% vol CH4 (high-accuracy leak range); 0 - 100% vol CH4 (wide-range process)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 40 s at 20\u00b0C\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Thermopile Detector\",\"zh\":\"Alphasense IRM-AT \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u7532\u70f7\u7684NDIR \u975e\u5206\u5149\u7ea2\u5916\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0 \u2013 2.5% vol CH4 (high-accuracy leak range); 0 - 100% vol CH4 (wide-range process)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-irm-at-1-768x510-ac7b632d48.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-irm-at-ca4ce1d8e3.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:6bf674c65ce9ad3c948e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CL2-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm Cl2\",\"sensitivity\":\"\u2212350 to \u2212750 nA \/ ppm (in 10 ppm Cl2)\",\"responseTime\":\"< 60 s (0 \u2192 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent, 33\u03a9 load resistor) < 0.02\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm Cl2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212350 to \u2212750 nA \/ ppm (in 10 ppm Cl2)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 60 s (0 \u2192 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent, 33\u03a9 load resistor) < 0.02\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense CL2-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm Cl2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-cl2-a1-abf5655eeb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-cl2-a1-aa198132c2.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:b360ab7a68afbf4ccd42\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CL2-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm Cl2\",\"sensitivity\":\"\u2212600 to \u22121150 nA \/ ppm (in 10 ppm Cl2)\",\"responseTime\":\"< 60 s (0 \u2192 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) (33\u03a9 load resistor) < 0.02\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm Cl2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212600 to \u22121150 nA \/ ppm (in 10 ppm Cl2)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 60 s (0 \u2192 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) (33\u03a9 load resistor) < 0.02\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense CL2-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm Cl2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-cl2-b1-af142d86ac.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-cl2-b1-1d9f13a030.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:a26ad0b06ed9e4db7501\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CL2-D4\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm Cl2\",\"sensitivity\":\"\u2212150 to \u2212350 nA \/ ppm (in 10 ppm Cl2)\",\"responseTime\":\"< 35 s (0 \u2192 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm Cl2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212150 to \u2212350 nA \/ ppm (in 10 ppm Cl2)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 35 s (0 \u2192 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Miniature Size\",\"zh\":\"Alphasense CL2-D4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm Cl2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-cl2-d4-ea000e5f1a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-cl2-d4-0a21a78980.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:21d59471ed37a83fc993\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CL-H4\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm Cl2\",\"sensitivity\":\"\u2212150 to \u2212350 nA \/ ppm (in 10 ppm Cl2)\",\"responseTime\":\"< 35 s (0 \u2192 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm Cl2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212150 to \u2212350 nA \/ ppm (in 10 ppm Cl2)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 35 s (0 \u2192 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Miniature Size\",\"zh\":\"Alphasense CL-H4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm Cl2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-cl2-h4-41d20f9fbd.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:75e8c39637a0cdb49f75\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"COH-A2 Dual Sensor\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO_H2S\",\"gasName\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm (typical portable safety ranges)\",\"sensitivity\":\"CO: 27 to 55 nA \/ ppm H2S: 90 to 175 nA \/ ppm\",\"responseTime\":\"< 25 s for CO < 30 s for H2S (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"rms noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm (typical portable safety ranges)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"CO: 27 to 55 nA \/ ppm H2S: 90 to 175 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s for CO < 30 s for H2S (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"rms noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"CO\/H2S A-Series Dual Sensor\",\"zh\":\"Alphasense COH-A2 Dual Sensor \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm (typical portable safety ranges)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-coh-a2-2-2e69e3981a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-h2s-287023d3be.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:1f48d7864afaf3345038\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S_CO A2\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO_H2S\",\"gasName\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"\",\"responseTime\":\"t90 (s) from zero to 400ppm CO < 35\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"rms noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"t90 (s) from zero to 400ppm CO < 35\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"rms noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"H2S\/CO A-Series Dual Sensor\",\"zh\":\"Alphasense H2S_CO A2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-coh-a2-2-2e69e3981a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-h2s-287023d3be.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:67c0cf490e4e945ad0c9\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S_CO D2\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"CO_H2S\",\"gasName\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"\",\"responseTime\":\"t90 (s) from zero to 400ppm CO < 25\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"rms noise (ppm equivalent) 1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"t90 (s) from zero to 400ppm CO < 25\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"rms noise (ppm equivalent) 1\"}],\"description\":{\"en\":\"H2S\/CO D-Series Dual Sensor\",\"zh\":\"Alphasense H2S_CO D2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-h2s-d2-2-b4b556c208.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-d2-ee06784aab.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:99636877430acfb15769\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO_H2S D2 Dual Sensors\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"CO_H2S\",\"gasName\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm\",\"sensitivity\":\"CO: 27 to 55 nA \/ ppm H2S: 90 to 175 nA \/ ppm\",\"responseTime\":\"CO: < 25 s (0\u2013400 ppm) H2S: < 30 s (0\u201320 ppm)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"rms noise (ppm equivalent) 1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"CO: 27 to 55 nA \/ ppm H2S: 90 to 175 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"CO: < 25 s (0\u2013400 ppm) H2S: < 30 s (0\u201320 ppm)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"rms noise (ppm equivalent) 1\"}],\"description\":{\"en\":\"CO\/H2S D-Series Dual Sensor\",\"zh\":\"Alphasense CO_H2S D2 Dual Sensors \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-h2s-d2-2-b4b556c208.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-d2-ee06784aab.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:97f342b6ac882140c762\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"COH-H2\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"CO_H2S\",\"gasName\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm\",\"sensitivity\":\"CO: 50 to 100 nA \/ ppm H2S: 90 to 175 nA \/ ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"rms noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"CO: 50 to 100 nA \/ ppm H2S: 90 to 175 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"rms noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"CO\/H2S H-Series Dual Sensor\",\"zh\":\"Alphasense COH-H2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a CO: 0\u20131,000 ppm H2S: 0\u2013100 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-h2s-2aca56e3ad.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:db91cf6d2fc10e3aa2be\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm\",\"sensitivity\":\"50\u2013100 nA \/ ppm\",\"responseTime\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"50\u2013100 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"A-Series Carbon Monoxide Sensor\",\"zh\":\"Alphasense CO-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20135,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-a4-1-0b5f89606c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-a1-2cf1a23377.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:c1626be2949adf184d1b\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-A4\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"nA\/ppm in 2ppm CO 220 to 410\",\"responseTime\":\"t90 (s) from zero to 10ppm CO < 30\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"nA\/ppm in 2ppm CO 220 to 410\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"t90 (s) from zero to 10ppm CO < 30\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 4-electrode, low ppb\",\"zh\":\"Alphasense CO-A4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-a4-e35bb7f8b8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-a4-6d1879acd3.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:738cfe4e0cb9a04bead1\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-AE\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310,000 ppm\",\"sensitivity\":\"10\u201325 nA \/ ppm\",\"responseTime\":\"< 50 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"10\u201325 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 50 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 5\"}],\"description\":{\"en\":\"Small, filtered, high concentration\",\"zh\":\"Alphasense CO-AE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201310,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-ae-252c3d50bd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-ae-8f14fdde94.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:d2a66b88f969db5e17a9\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-AF\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm\",\"sensitivity\":\"55\u2013100 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"55\u2013100 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Small, filtered\",\"zh\":\"Alphasense CO-AF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20135,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-af-6f87510b54.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-af-bdb1ef16b1.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:ea25522a177c12e85bb7\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-AX\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm\",\"sensitivity\":\"55\u2013100 nA \/ ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"55\u2013100 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Small, low hydrdogen cross sensitivity\",\"zh\":\"Alphasense CO-AX \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-ax-bd1f4fbcdb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-ax-a2bb62a05f.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:3b40db6b7a9909cc4cfb\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm\",\"sensitivity\":\"80\u2013130 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80\u2013130 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"B-Series Carbon Monoxide sensor\",\"zh\":\"Alphasense CO-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20135,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-b1-c9e53466c8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-b1-4be6f3c592.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:d5c60513a3ffd4aa77b6\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-B4\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131,000 ppm\",\"sensitivity\":\"420\u2013650 nA \/ ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"420\u2013650 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Compact, 4-electrode, low ppb\",\"zh\":\"Alphasense CO-B4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20131,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-b4-01-ef18d74ec3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-b4-3e01b8d05a.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:47ddee03a3707d1e37d7\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-BF\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm\",\"sensitivity\":\"80\u2013130 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80\u2013130 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Compact, filtered\",\"zh\":\"Alphasense CO-BF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20135,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-bf-e5a7acaa9f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-bf-411e4fa736.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:638750d7fa3588329e9f\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-BX\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm\",\"sensitivity\":\"70\u2013130 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"70\u2013130 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Compact, low hydrogen cross sensitivity\",\"zh\":\"Alphasense CO-BX \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-bx-3855d9313b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-bx-8cc8681530.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:cf0be2582444d50d79f5\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-CE\",\"seriesKey\":\"alphasense:c-series\",\"series\":{\"en\":\"C Series\",\"zh\":\"C \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310,000 ppm\",\"sensitivity\":\"10\u201325 nA \/ ppm\",\"responseTime\":\"< 75 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"10\u201325 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 75 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 5\"}],\"description\":{\"en\":\"Combustion, high concentration\",\"zh\":\"Alphasense CO-CE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201310,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-cx-1-40c8bdce79.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-ce-a4528fd893.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:ff38163e29dc3f37dcf9\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-CF\",\"seriesKey\":\"alphasense:c-series\",\"series\":{\"en\":\"C Series\",\"zh\":\"C \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm\",\"sensitivity\":\"55\u201390 nA \/ ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"55\u201390 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Combustion, filtered\",\"zh\":\"Alphasense CO-CF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20135,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-cx-1-40c8bdce79.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-cf-13024a76b0.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:caf1fde08098e1024728\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-CX\",\"seriesKey\":\"alphasense:c-series\",\"series\":{\"en\":\"C Series\",\"zh\":\"C \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm\",\"sensitivity\":\"55\u2013100 nA \/ ppm\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"55\u2013100 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Combustion, low hydrogen cross sensitivity\",\"zh\":\"Alphasense CO-CX \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-cx-1-40c8bdce79.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-cx-14a04c0407.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:d0459ac090e60e4feb79\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-D4\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131,000 ppm\",\"sensitivity\":\"30\u201355 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 1.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"30\u201355 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 1.5\"}],\"description\":{\"en\":\"Filtered\",\"zh\":\"Alphasense CO-D4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20131,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-d4-fb436af575.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-d4-51777faa0c.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:a088db5b116c38bea7aa\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-D4X\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131,000 ppm\",\"sensitivity\":\"18\u201345 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 1.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"18\u201345 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 1.5\"}],\"description\":{\"en\":\"Carbon Monoxide (low Hydrogen cross -sensitivity) D-Series sensor\",\"zh\":\"Alphasense CO-D4X \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20131,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-co-d4x-ec9657218d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-d4x-83a02389b1.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:b1c8aa06c776fcd3862a\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-H4\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131,000 ppm\",\"sensitivity\":\"30\u201355 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 1.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"30\u201355 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 1.5\"}],\"description\":{\"en\":\"Filtered H-series\",\"zh\":\"Alphasense CO-H4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20131,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-h4-f9fab86923.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:9693160047931a56aa99\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CO-H4X\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131,000 ppm\",\"sensitivity\":\"18\u201345 nA \/ ppm\",\"responseTime\":\"< 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 1.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"18\u201345 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 1.5\"}],\"description\":{\"en\":\"Carbon Monoxide (low Hydrogen cross -sensitivity) H-Series sensor\",\"zh\":\"Alphasense CO-H4X \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20131,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-co-h4x-46dffce4f1.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:3abadb8af6b929db6863\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"IRC-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"IAQ: 0\u20135,000 ppm Safety: 0\u20135 % vol Combustion: 0\u201320 % vol Process: 0\u2013100 % vol\",\"sensitivity\":\"\",\"responseTime\":\"< 40 s at 20 \u00b0C\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"IAQ: 1 ppm \/ 15 ppm Safety: 1 ppm \/ 100 ppm Combustion: 1 ppm \/ 500 ppm Process: 1 ppm \/ 0.5 % vol\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"IAQ: 0\u20135,000 ppm Safety: 0\u20135 % vol Combustion: 0\u201320 % vol Process: 0\u2013100 % vol\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 40 s at 20 \u00b0C\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"IAQ: 1 ppm \/ 15 ppm Safety: 1 ppm \/ 100 ppm Combustion: 1 ppm \/ 500 ppm Process: 1 ppm \/ 0.5 % vol\"}],\"description\":{\"en\":\"Pyroelectric Detector\",\"zh\":\"Alphasense IRC-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u78b3\u7684NDIR \u975e\u5206\u5149\u7ea2\u5916\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a IAQ: 0\u20135,000 ppm Safety: 0\u20135 % vol Combustion: 0\u201320 % vol Process: 0\u2013100 % vol\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-irc-a1-1-c6fb97fe22.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-irc-a1-fb60fc9b4c.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:fb87702f4a4bb4ea0844\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"IRC-AT\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"IAQ: 0\u20135,000 ppm Safety: 0\u20135 % vol Combustion: 0\u201320 % vol Process: 0\u2013100 % vol\",\"sensitivity\":\"\",\"responseTime\":\"< 40 s at 20 \u00b0C\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"IAQ: 10 ppm \/ 50 ppm Safety: 10 ppm \/ 100 ppm Combustion: 10 ppm \/ 2000 ppm Process: 10 ppm \/ tbc\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"IAQ: 0\u20135,000 ppm Safety: 0\u20135 % vol Combustion: 0\u201320 % vol Process: 0\u2013100 % vol\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 40 s at 20 \u00b0C\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"IAQ: 10 ppm \/ 50 ppm Safety: 10 ppm \/ 100 ppm Combustion: 10 ppm \/ 2000 ppm Process: 10 ppm \/ tbc\"}],\"description\":{\"en\":\"Thermopile Detector\",\"zh\":\"Alphasense IRC-AT \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u78b3\u7684NDIR \u975e\u5206\u5149\u7ea2\u5916\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a IAQ: 0\u20135,000 ppm Safety: 0\u20135 % vol Combustion: 0\u201320 % vol Process: 0\u2013100 % vol\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-irc-at-1-04e8ee188f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-irc-at-debe4f1e17.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:b1e8e38d7b9f7e996ab8\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"ETO-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm EtO\",\"sensitivity\":\"2000 to 3200 nA \/ ppm (in 20 ppm EtO)\",\"responseTime\":\"< 150 s (0 \u219220 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm EtO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"2000 to 3200 nA \/ ppm (in 20 ppm EtO)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 150 s (0 \u219220 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense ETO-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm EtO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-eto-a1-2-bd1157c168.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-eto-a1-4ce80a6c65.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:866efaa54a7868708979\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"ETO-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm EtO\",\"sensitivity\":\"2000 to 3400 nA \/ ppm (in 20 ppm EtO)\",\"responseTime\":\"< 200 s (0 \u219220 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm EtO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"2000 to 3400 nA \/ ppm (in 20 ppm EtO)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 200 s (0 \u219220 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense ETO-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm EtO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-eto-b1-2-b6fd8a547d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-eto-b1-c05304e6de.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:c6b7d4d622dc1b61b796\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2-AF\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm H2\",\"sensitivity\":\"10 to 40 nA \/ ppm (in 400 ppm H2)\",\"responseTime\":\"< 35 s (0 \u2192400 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.7\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm H2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"10 to 40 nA \/ ppm (in 400 ppm H2)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 35 s (0 \u2192400 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.7\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense H2-AF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm H2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2-af-2-d17df67d84.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2-af-c7f782d3d2.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:766639c6f9d0f92ca0b1\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2-BF\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm H2\",\"sensitivity\":\"10 to 25 nA \/ ppm (in 400 ppm H2)\",\"responseTime\":\"< 55 s (0 \u2192400 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.8\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm H2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"10 to 25 nA \/ ppm (in 400 ppm H2)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 55 s (0 \u2192400 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.8\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense H2-BF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20135,000 ppm H2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2-bf-2-894809df2e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2-bf-e90fcb5306.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:db331620e48c61d431e1\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2O2-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide (H2O2)\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm H2O2\",\"sensitivity\":\"50 to 90 nA \/ ppm (in 400 ppm surrogate gas)\",\"responseTime\":\"< 25 s (0 \u2192400 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm H2O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"50 to 90 nA \/ ppm (in 400 ppm surrogate gas)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s (0 \u2192400 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense H2O2-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm H2O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h202-a1-0ea57f60c2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2o2-a1-21f414e44d.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:3343674702fe2118ee33\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2O2-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide (H2O2)\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm H2O2\",\"sensitivity\":\"50 to 90 nA \/ ppm (in 400 ppm surrogate gas)\",\"responseTime\":\"< 25 s (0 \u2192400 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm H2O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"50 to 90 nA \/ ppm (in 400 ppm surrogate gas)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s (0 \u2192400 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense H2O2-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm H2O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h202-b1-02648635ca.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2o2-b1-d1dce877fe.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:37e4ba4100f360ba42f8\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2_H2S A2 Dual Sensor\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2S_SO2\",\"gasName\":{\"en\":\"Hydrogen Sulfide \/ Sulfur Dioxide\",\"zh\":\"\u786b\u5316\u6c22 \/ \u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"nA\/ppm in 10ppm SO2 140 to 250\",\"responseTime\":\"t90 (s) from zero to 10ppm SO2 < 15\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"rms noise (ppm equivalent) < 0.2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"nA\/ppm in 10ppm SO2 140 to 250\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"t90 (s) from zero to 10ppm SO2 < 15\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"rms noise (ppm equivalent) < 0.2\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense SO2_H2S A2 Dual Sensor \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22 \/ \u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-soh-a2-01-3b526998d2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-soh-a2-3a7a737515.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:3c748f49cfcb21ca4757\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SOH-A2\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2S_SO2\",\"gasName\":{\"en\":\"Hydrogen Sulfide \/ Sulfur Dioxide\",\"zh\":\"\u786b\u5316\u6c22 \/ \u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"SO2: 0\u201320 ppm; H2S: 0\u2013100 ppm\",\"sensitivity\":\"SO2: 140 to 250 nA \/ ppm H2S: 450 to 900 nA \/ ppm\",\"responseTime\":\"SO2: < 15 s H2S: < 25 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"rms noise (ppm equivalent) < 0.2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"SO2: 0\u201320 ppm; H2S: 0\u2013100 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"SO2: 140 to 250 nA \/ ppm H2S: 450 to 900 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"SO2: < 15 s H2S: < 25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"rms noise (ppm equivalent) < 0.2\"}],\"description\":{\"en\":\"H2S\/SO2 A-Series Dual Sensor\",\"zh\":\"Alphasense SOH-A2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22 \/ \u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a SO2: 0\u201320 ppm; H2S: 0\u2013100 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-soh-a2-01-3b526998d2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-soh-a2-3a7a737515.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:56ee661ae0d0c9f706de\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-A1 Hydrogen Sulphide Sensor\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100 ppm H2S\",\"sensitivity\":\"550 to 900 nA \/ ppm\",\"responseTime\":\"< 35s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.05\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"550 to 900 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 35s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.05\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense H2S-A1 Hydrogen Sulphide Sensor \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-100 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-a1-01-525cc0b43d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-a1-series-6ea8a5bc0d.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:27e067e0caf947a8e11f\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-A4\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"1400 to 2200 nA \/ ppm\",\"responseTime\":\"<60s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"1400 to 2200 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"<60s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 4-electrode, low ppb\",\"zh\":\"Alphasense H2S-A4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-a4-01-f120f844fa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-a4-2b0bab41e8.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:82caaf7799778628d27e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-AE\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-2000 ppm H2S\",\"sensitivity\":\"65 to 125 nA \/ ppm\",\"responseTime\":\"< 25s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-2000 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"65 to 125 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Small, high concentration\",\"zh\":\"Alphasense H2S-AE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-2000 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-ae-01-9234d326d8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-ae-dbbf073534.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:cf2dc5f2e61bfee56367\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-AH\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm H2S\",\"sensitivity\":\"900 to 1500 nA \/ ppm\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.03\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"900 to 1500 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.03\"}],\"description\":{\"en\":\"Small, high sensitivity\",\"zh\":\"Alphasense H2S-AH \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-ah-01-dfad1d5a56.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-ah-tds-50287b43e0.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:02612f84a0fcf21772df\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm H2S\",\"sensitivity\":\"300 to 525 nA \/ ppm\",\"responseTime\":\"< 55 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.05\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"300 to 525 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 55 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.05\"}],\"description\":{\"en\":\"Compact, unfiltered\",\"zh\":\"Alphasense H2S-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013200 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-b1-01-c338690d8f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-b1-6681172728.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:af5c2b9414ff5ca2122f\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-B4\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm H2S with ppb\u2011level resolution\",\"sensitivity\":\"1,450 to 2,600 nA \/ ppm\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm H2S with ppb\u2011level resolution\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"1,450 to 2,600 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 60s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Compact, 4-electrode, low ppb\",\"zh\":\"Alphasense H2S-B4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm H2S with ppb\u2011level resolution\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-b4-01-c46f50ee5e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-b4-4ff549c29d.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:991c7ebe197070160dc5\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-BE\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm H2S\",\"sensitivity\":\"80 to 140 nA \/ ppm\",\"responseTime\":\"< 50s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80 to 140 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 50s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.5\"}],\"description\":{\"en\":\"Compact, high concentration\",\"zh\":\"Alphasense H2S-BE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-be-01-250ed381ee.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-be-1b320aeac5.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:8df37df504cdad0f3cd0\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-BH\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm H2S\",\"sensitivity\":\"1,400 to 2,200 nA \/ ppm\",\"responseTime\":\"< 55s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.02\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"1,400 to 2,200 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 55s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.02\"}],\"description\":{\"en\":\"Compact, high sensitivity\",\"zh\":\"Alphasense H2S-BH \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-bh-01-f89ac1e2be.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-bh-6d97d0e96a.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:71f3625b7c2c16845450\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-D4\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm H2S\",\"sensitivity\":\"110 to 170 nA \/ ppm\",\"responseTime\":\"< 25s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"110 to 170 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.2\"}],\"description\":{\"en\":\"Miniature Size\",\"zh\":\"Alphasense H2S-D4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h2s-d4-01-e28f6c0669.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-d4-55dc87eebc.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:5e94644e1402ab697c7e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"H2S-H4\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm H2S\",\"sensitivity\":\"110 to 170 nA \/ ppm\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm H2S\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"110 to 170 nA \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 60s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.2\"}],\"description\":{\"en\":\"Miniature Size H-series\",\"zh\":\"Alphasense H2S-H4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm H2S\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-h2s-h4-34e0b23900.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:9f0163d45ce377c21b52\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"HCL-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm HCl\",\"sensitivity\":\"50 to 140 nA \/ ppm (in 25 ppm HCl)\",\"responseTime\":\"< 300 s (0 \u219225 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm HCl\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"50 to 140 nA \/ ppm (in 25 ppm HCl)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 300 s (0 \u219225 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 1\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense HCL-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm HCl\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-hcl-a1-2-b75814f953.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-hcl-a1-8cd265e329.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:b7bfa9d8340ca43c30df\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"HCL-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm HCl\",\"sensitivity\":\"120 to 250 nA \/ ppm ( in 25 ppm HCl)\",\"responseTime\":\"< 200 s (0 \u219225 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm HCl\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"120 to 250 nA \/ ppm ( in 25 ppm HCl)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 200 s (0 \u219225 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense HCL-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm HCl\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-hcl-b1-2-db8f518b97.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-hcl-b1-c79696c931.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:345c7e9398c78f7d7cdc\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"HCN-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm HCN\",\"sensitivity\":\"45 to 85 nA \/ ppm (in 30 ppm HCN)\",\"responseTime\":\"< 70 s (0 \u2192 30 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.05\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm HCN\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"45 to 85 nA \/ ppm (in 30 ppm HCN)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 70 s (0 \u2192 30 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.05\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense HCN-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm HCN\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-hcn-a1-3-f07fb7654c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-hcn-a1-62f7a3ca42.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:beeec1b767d37d7cc166\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"HCN-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm HCN\",\"sensitivity\":\"65 to 140 nA \/ ppm (in 30 ppm HCN)\",\"responseTime\":\"< 120 s (0 \u219230 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.05\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm HCN\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"65 to 140 nA \/ ppm (in 30 ppm HCN)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 120 s (0 \u219230 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.05\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense HCN-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm HCN\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-hcn-b1-2-492b740458.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-hcn-b1-2ba9c4917a.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:a0625ab1030334e7e1e3\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"HCN-D4\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm HCN\",\"sensitivity\":\"30 to 50 nA \/ ppm (in 20 ppm HCN)\",\"responseTime\":\"< 50 s (0 \u219220 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.3\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm HCN\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"30 to 50 nA \/ ppm (in 20 ppm HCN)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 50 s (0 \u219220 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.3\"}],\"description\":{\"en\":\"Miniature Size\",\"zh\":\"Alphasense HCN-D4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm HCN\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-hcn-d4-2-2b1327c175.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-hcn-d4-13992e5f3b.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:4aa9e87334427f63052e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"HCN-H4\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm HCN\",\"sensitivity\":\"30 to 50 nA \/ ppm (in 20 ppm HCN)\",\"responseTime\":\"< 50 s (0 \u219220 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.3\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm HCN\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"30 to 50 nA \/ ppm (in 20 ppm HCN)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 50 s (0 \u219220 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.3\"}],\"description\":{\"en\":\"Miniature Size H-series\",\"zh\":\"Alphasense HCN-H4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm HCN\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-hcn-h4-be666b07b3.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:c6a1eae04289ae269cd8\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"CH-A3\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"LEL_CH4\",\"gasName\":{\"en\":\"LEL\/Methane (LEL\/CH4)\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53 \/ \u7532\u70f7\uff08LEL\uff09\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0 \u2013 100% LEL methane\",\"sensitivity\":\"15 \u2013 22 mV per % CH4\",\"responseTime\":\"< 15 s (typically < 7 s) from air to 50% LEL\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100% LEL methane\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"15 \u2013 22 mV per % CH4\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 15 s (typically < 7 s) from air to 50% LEL\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 3v\",\"zh\":\"Alphasense CH-A3 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u53ef\u71c3\u6c14\u4f53 \/ \u7532\u70f7\uff08LEL\uff09\u7684\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0 \u2013 100% LEL methane\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-cha3-1-1-1742b8feb3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-cha3-bb139f07b6.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:54433e25a6923dbc571d\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NH3-AF\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm NH3\",\"sensitivity\":\"15 to 40 nA \/ ppm (in 50 ppm NH3)\",\"responseTime\":\"\u2248 300 s (0 \u219250 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm NH3\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"15 to 40 nA \/ ppm (in 50 ppm NH3)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"\u2248 300 s (0 \u219250 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Ammonia (NH3) A-Series\",\"zh\":\"Alphasense NH3-AF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm NH3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-nh3-af-2-d3efcf3280.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-nh3-af-99a4971b11.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:8d9f0fb45954a02eca60\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NH3-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm NH3\",\"sensitivity\":\"20 to 60 nA \/ ppm (in 50 ppm NH3)\",\"responseTime\":\"< 150 s (0 \u219250 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm NH3\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"20 to 60 nA \/ ppm (in 50 ppm NH3)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 150 s (0 \u219250 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense NH3-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm NH3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-nh3-b1-2-aecc1b8bb0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-nh3-b1-be95f4c7f3.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:da068a3de34f3dfee462\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013250 ppm NO\",\"sensitivity\":\"320 to 480 nA \/ ppm in 50 ppm NO\",\"responseTime\":\"< 45 s (0 to 50 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013250 ppm NO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"320 to 480 nA \/ ppm in 50 ppm NO\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 45 s (0 to 50 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.2\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense NO-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013250 ppm NO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no-a1-01-87c2cd89a3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no-a1-0fd3597437.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:6382d7f5c19b9d32feaa\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO-A4\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO\",\"sensitivity\":\"350 to 550 nA \/ ppm in 2 ppm NO\",\"responseTime\":\"< 25 s (0 to 2 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"350 to 550 nA \/ ppm in 2 ppm NO\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s (0 to 2 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 4-electrode, low ppb\",\"zh\":\"Alphasense NO-A4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no-a4-01-a7c6413ae8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no-a4-88606bd322.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:e09bfaba67f6f4247586\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO-AE\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm NO\",\"sensitivity\":\"40 to 80 nA \/ ppm in 250 ppm NO\",\"responseTime\":\"< 75 s (0 to 250 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm NO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"40 to 80 nA \/ ppm in 250 ppm NO\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 75 s (0 to 250 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 1\"}],\"description\":{\"en\":\"Small, high concentration\",\"zh\":\"Alphasense NO-AE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20135,000 ppm NO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no-ae-01-bae9e63776.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no-ae-22f4d4d363.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:796c58a9202bb29cab6d\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013250 ppm NO\",\"sensitivity\":\"400 to 620 nA \/ ppm in 50 ppm NO\",\"responseTime\":\"< 30 s (0 to 50 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.15\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013250 ppm NO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"400 to 620 nA \/ ppm in 50 ppm NO\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s (0 to 50 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.15\"}],\"description\":{\"en\":\"Compact, filtered\",\"zh\":\"Alphasense NO-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013250 ppm NO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no-b1-01-bee232759d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no-b1-0fa7868837.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:41339a3c25c29f5def2b\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO-B4\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO\",\"sensitivity\":\"500 to 850 nA \/ ppm in 2 ppm NO\",\"responseTime\":\"< 45 s (0 to 2 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"500 to 850 nA \/ ppm in 2 ppm NO\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 45 s (0 to 2 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Compact, 4-electrode, low ppb\",\"zh\":\"Alphasense NO-B4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no-b4-01-1bb5ac8860.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no-b4-3976150b4d.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:b8093fb5bcfcbae54970\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO-D4\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm NO\",\"sensitivity\":\"450 to 600 nA \/ ppm in 40 ppm NO\",\"responseTime\":\"< 15 s (0 to 40 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm NO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"450 to 600 nA \/ ppm in 40 ppm NO\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 15 s (0 to 40 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Miniature Size\",\"zh\":\"Alphasense NO-D4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm NO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no-d4-01-79fe7b695a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no-d4-062f579c8e.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:d70398de8082dea31064\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO-H4\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm NO\",\"sensitivity\":\"450 to 600 nA \/ ppm in 40 ppm NO\",\"responseTime\":\"< 15 s (0 to 40 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm NO\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"450 to 600 nA \/ ppm in 40 ppm NO\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 15 s (0 to 40 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Miniature Size H-series\",\"zh\":\"Alphasense NO-H4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm NO\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no-h4-d2b86ae653.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:7e77f03c1bccd229707e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO2-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO2\",\"sensitivity\":\"\u2212250 to \u2212650 nA \/ ppm in 10 ppm NO2\",\"responseTime\":\"< 50 s (0 to 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) (33\u03a9 Load Resistor) < 0.02\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212250 to \u2212650 nA \/ ppm in 10 ppm NO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 50 s (0 to 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) (33\u03a9 Load Resistor) < 0.02\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense NO2-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no2-a1-01-e6255b95f6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no2-a1-fa795213f3.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:a4e3b01af68ae88c9a49\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO2-A43F\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO2 (ppb-level resolution)\",\"sensitivity\":\"\u2212175 to \u2212500 nA \/ ppm at 2 ppm NO2\",\"responseTime\":\"< 80 s (0 to 2 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO2 (ppb-level resolution)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212175 to \u2212500 nA \/ ppm at 2 ppm NO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 80 s (0 to 2 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 4-electrode, low ppb\",\"zh\":\"Alphasense NO2-A43F \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO2 (ppb-level resolution)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no2-a43f-01-133e625814.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no2-a43f-ff4732d8cb.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:dbfe339478bbc644dc13\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO2-AE\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm NO2\",\"sensitivity\":\"\u221270 to \u2212170 nA \/ ppm in 10 ppm NO2\",\"responseTime\":\"< 40 s (0 to 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) (33\u03a9) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm NO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u221270 to \u2212170 nA \/ ppm in 10 ppm NO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 40 s (0 to 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) (33\u03a9) < 0.1\"}],\"description\":{\"en\":\"Small, high concentration\",\"zh\":\"Alphasense NO2-AE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013200 ppm NO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no2-ae-01-9ff8d09f7d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no2-ae-a099268e9f.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:7a9035c10b820829feb2\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO2-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO2\",\"sensitivity\":\"\u2212450 to \u22121000 nA \/ ppm in 10 ppm NO2\",\"responseTime\":\"< 60 s (0 to 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) (33\u03a9 load resistor) < 0.02\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212450 to \u22121000 nA \/ ppm in 10 ppm NO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 60 s (0 to 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) (33\u03a9 load resistor) < 0.02\"}],\"description\":{\"en\":\"Compact, unfiltered\",\"zh\":\"Alphasense NO2-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no2-b1-01-69640cfbb9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no2-b1-b635ac913a.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:10700cb1499f7022ee65\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO2-B43F\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO2 (ppb-level resolution)\",\"sensitivity\":\"\u2212200 to \u2212650 nA \/ ppm at 2 ppm NO2\",\"responseTime\":\"< 80 s (0 to 2 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO2 (ppb-level resolution)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212200 to \u2212650 nA \/ ppm at 2 ppm NO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 80 s (0 to 2 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Compact, 4-electrode, low ppb\",\"zh\":\"Alphasense NO2-B43F \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO2 (ppb-level resolution)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no2-b43f-01-530baf125d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no2-b43f-a78b3cd978.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:303a1817a23aa7fab49e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO2-D4\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO2\",\"sensitivity\":\"\u2212100 to \u2212350 nA \/ ppm in 10 ppm NO2\",\"responseTime\":\"< 35 s (0 to 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2212100 to \u2212350 nA \/ ppm in 10 ppm NO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 35 s (0 to 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) 0.1\"}],\"description\":{\"en\":\"Miniature Size\",\"zh\":\"Alphasense NO2-D4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-no2-d4-01-e6a1ddc934.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-no2-d4-7fbbfe7401.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:42e1277d831103a47d2e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"NO2-H4\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO2\",\"sensitivity\":\"-100 to -350 nA \/ ppm in 10 ppm NO2\",\"responseTime\":\"< 35s (0 to 10 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"-100 to -350 nA \/ ppm in 10 ppm NO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 35s (0 to 10 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) 0.1\"}],\"description\":{\"en\":\"Miniature Size H-series\",\"zh\":\"Alphasense NO2-H4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm NO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-alphsense-no2-h4-fbe24c3df7.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:4c70d00832f0f78c6d27\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"LFO2-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"80 to 130 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 6s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80 to 130 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 6s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Long-Life, Lead Free\",\"zh\":\"Alphasense LFO2-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-lfo2-a1-01-99a95bed2c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-lfo2-a1-f3ef7f66cd.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:e30e4fcd4504d03f9164\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"LFO2-A4\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Lead Free, long life\",\"zh\":\"Alphasense LFO2-A4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-lfo2-a4-02-e5d7cae995.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-lfo2-a4-87741520db.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:f1fd83cee8cf2937ae71\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"LFO2-AH\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-2% O2\",\"sensitivity\":\"60 to 110 \u00b5A @ 2.% O2\",\"responseTime\":\"< 6s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-2% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"60 to 110 \u00b5A @ 2.% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 6s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Long-Life, Lead Free\",\"zh\":\"Alphasense LFO2-AH \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-2% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-lfo2-ah-01-0ef299bd49.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-lfo2-ah-2efe4f674b.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:ad317e76e685fa2b1a82\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"LFO2-AL\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-95% O2\",\"sensitivity\":\"20 to 45 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 6s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-95% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"20 to 45 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 6s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Long-Life, Lead Free\",\"zh\":\"Alphasense LFO2-AL \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-95% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-lfo2-al-01-ade2e15428.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-lfo2-al-0226282369.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:c50bba3bdf3645ea653d\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"190 to 240 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 8s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"190 to 240 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 8s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 1 year\",\"zh\":\"Alphasense O2-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-a1-02-c9a9193c80.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-a1-4f607548ad.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:7f9e98181a2ee280624b\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-A2\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"80 to 120 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 8s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80 to 120 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 8s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 2 year\",\"zh\":\"Alphasense O2-A2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-a2-02-e7968ecc9b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-a2-3155f499d8.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:ba1044155cb4376b4dc4\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-A2-GLF\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"80 to 120 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 8s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80 to 120 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 8s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Lead-free, A-series\",\"zh\":\"Alphasense O2-A2-GLF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-a2-glf-3-no-bg-34c43ea639.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-a2-glf-8b73036874.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:570608b760ae6f9ff34d\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-A2S-GLF\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"80 to 120 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 8s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80 to 120 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 8s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Lead-free, A-series\",\"zh\":\"Alphasense O2-A2S-GLF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-a2-glf-3-no-bg-34c43ea639.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-a2-glf-8b73036874.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:c55c011439e27ad612ce\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-A3\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"55 to 85 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 8s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"55 to 85 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 8s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 3 year\",\"zh\":\"Alphasense O2-A3 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-a3-02-c9c0861cd1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-a3-b432c63af9.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:f12a03c41fa9747efa84\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-C2\",\"seriesKey\":\"alphasense:c-series\",\"series\":{\"en\":\"C Series\",\"zh\":\"C \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"80 to 120 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 50s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"80 to 120 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 50s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Combustion, 2 year\",\"zh\":\"Alphasense O2-C2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-c2-01-0f4560ca95.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-c2-90abbc7cfd.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:dd84a38210d78051ec6c\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-G1\",\"seriesKey\":\"alphasense:g-series\",\"series\":{\"en\":\"G Series\",\"zh\":\"G \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"\",\"responseTime\":\"t90 (s) from 20.9% to 0% O2 (47W load resistor) < 18\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"t90 (s) from 20.9% to 0% O2 (47W load resistor) < 18\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Low profile, 1 year\",\"zh\":\"Alphasense O2-G1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-g2-01-0e8f087e90.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-g1-b0dea8ac1b.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:dcb6c8d542e7d7c09dc4\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O2-G2\",\"seriesKey\":\"alphasense:g-series\",\"series\":{\"en\":\"G Series\",\"zh\":\"G \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30% O2\",\"sensitivity\":\"30 to 42 \u00b5A @ 20.9% O2\",\"responseTime\":\"< 20s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30% O2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"30 to 42 \u00b5A @ 20.9% O2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 20s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Low profile, 2 year\",\"zh\":\"Alphasense O2-G2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-30% O2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o2-g2-02-03950ca603.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o2-g2-2218dbb06d.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:0c78d3e54536e0ad6d4b\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"OX-A431\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 \u2013 20 ppm O3 0 \u2013 20 ppm NO2 (ppb-level resolution)\",\"sensitivity\":\"nA\/ppm at 1ppm O3 -200 to -650\",\"responseTime\":\"< 80 s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 20 ppm O3 0 \u2013 20 ppm NO2 (ppb-level resolution)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"nA\/ppm at 1ppm O3 -200 to -650\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 80 s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 4-electrode, low ppb\",\"zh\":\"Alphasense OX-A431 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0 \u2013 20 ppm O3 0 \u2013 20 ppm NO2 (ppb-level resolution)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-ox-a431-2-d6fcbcfb2b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-ox-a431-b6769ec5f8.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:1392f39faa5ef5eeca80\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"OX-AH\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 \u2013 20 ppm O3 (ppb\u2013ppm capable)\",\"sensitivity\":\"\u2013200 to \u2013700 nA \/ ppm at 1 ppm O3\",\"responseTime\":\"< 80 s (0 \u2192 1 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 20 ppm O3 (ppb\u2013ppm capable)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2013200 to \u2013700 nA \/ ppm at 1 ppm O3\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 80 s (0 \u2192 1 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"3-electrode\",\"zh\":\"Alphasense OX-AH \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0 \u2013 20 ppm O3 (ppb\u2013ppm capable)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o3-ah-1-f8ab19782f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o3-ah-b90a571286.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:862b961be1dd5d3dda86\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"O3-AH\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 \u2013 20 ppm O3 (ppb\u2013ppm capable)\",\"sensitivity\":\"\u2013200 to \u2013700 nA \/ ppm at 1 ppm O3\",\"responseTime\":\"< 80 s (0 \u2192 1 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 20 ppm O3 (ppb\u2013ppm capable)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2013200 to \u2013700 nA \/ ppm at 1 ppm O3\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 80 s (0 \u2192 1 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"3-electrode\",\"zh\":\"Alphasense O3-AH \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0 \u2013 20 ppm O3 (ppb\u2013ppm capable)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-o3-ah-1-f8ab19782f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-o3-ah-0155d75355.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:3c8814436642fbe984fd\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"OX-B431\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 \u2013 20 ppm O3; 0 \u2013 20 ppm NO2 (ppb-level resolution)\",\"sensitivity\":\"nA\/ppm at 1ppm O3 -225 to -750\",\"responseTime\":\"< 80 s (typical)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 20 ppm O3; 0 \u2013 20 ppm NO2 (ppb-level resolution)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"nA\/ppm at 1ppm O3 -225 to -750\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 80 s (typical)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Compact, 4-electrode, low ppb\",\"zh\":\"Alphasense OX-B431 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0 \u2013 20 ppm O3; 0 \u2013 20 ppm NO2 (ppb-level resolution)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-ox-b431-2-c6e81d80bd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-ox-b431-8a5f5290a4.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:2a0fa3d42205fdb8b658\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PH3-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm PH3\",\"sensitivity\":\"550 to 900 nA \/ ppm (in 11 ppm PH3)\",\"responseTime\":\"< 25 s (0 \u2192 5 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm PH3\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"550 to 900 nA \/ ppm (in 11 ppm PH3)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 25 s (0 \u2192 5 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Compact, high concentration\",\"zh\":\"Alphasense PH3-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm PH3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-ph3-a1-2-f138f21cc8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-ph3-a1-307a9f7fca.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:aa1052d9b372f02ca208\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PH3-B1\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm PH3\",\"sensitivity\":\"600 to 1,000 nA \/ ppm (in 5 ppm PH3)\",\"responseTime\":\"< 20 s (0 \u2192 5 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.03\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm PH3\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"600 to 1,000 nA \/ ppm (in 5 ppm PH3)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 20 s (0 \u2192 5 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.03\"}],\"description\":{\"en\":\"Compact\",\"zh\":\"Alphasense PH3-B1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm PH3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-ph3-b1-2-97e16a9a05.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-ph3-b1-fa6ab6596b.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:945c9a1aad5922d98e6b\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PH3-BE\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm PH3\",\"sensitivity\":\"15 to 35 nA \/ ppm (in 800 ppm PH3)\",\"responseTime\":\"< 30 s (0 \u2192 800 ppm step)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm PH3\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"15 to 35 nA \/ ppm (in 800 ppm PH3)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s (0 \u2192 800 ppm step)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 2\"}],\"description\":{\"en\":\"Small\",\"zh\":\"Alphasense PH3-BE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm PH3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-ph3-be-1-7bb11889d9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-ph3-be-38a28ce555.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:bd46838a854bee65146b\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"OPC-N3\",\"seriesKey\":\"alphasense:n3\",\"series\":{\"en\":\"N3 Optical Particle Counter\",\"zh\":\"N3 \u5149\u5b66\u9897\u7c92\u7269\u8ba1\u6570\u5668\"},\"gas\":\"PM\",\"gasName\":{\"en\":\"Particulate Matter\",\"zh\":\"\u9897\u7c92\u7269\"},\"tech\":\"OPTICAL_PARTICLE\",\"techName\":{\"en\":\"Optical Particle Counting\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\u68c0\u6d4b\"},\"specs\":{\"range\":\"0.35\u201340 \u03bcm\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0.35\u201340 \u03bcm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Particulate Monitor\",\"zh\":\"Alphasense OPC-N3 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u9897\u7c92\u7269\u7684\u5149\u5b66\u9897\u7c92\u7269\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0.35\u201340 \u03bcm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-opc-n3-1-db4d29d4db.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-opc-n3-aae9c6dc49.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:d805e66af9421ce560f1\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"OPC-R2\",\"seriesKey\":\"alphasense:r2\",\"series\":{\"en\":\"R2 Optical Particle Counter\",\"zh\":\"R2 \u5149\u5b66\u9897\u7c92\u7269\u8ba1\u6570\u5668\"},\"gas\":\"PM\",\"gasName\":{\"en\":\"Particulate Matter\",\"zh\":\"\u9897\u7c92\u7269\"},\"tech\":\"OPTICAL_PARTICLE\",\"techName\":{\"en\":\"Optical Particle Counting\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\u68c0\u6d4b\"},\"specs\":{\"range\":\"0.30\u201312.4 \u03bcm\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0.30\u201312.4 \u03bcm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Particulate Monitor\",\"zh\":\"Alphasense OPC-R2 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u9897\u7c92\u7269\u7684\u5149\u5b66\u9897\u7c92\u7269\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0.30\u201312.4 \u03bcm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-opc-r2-2-1-723c65c07d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-opc-r2-e7e1d0dac6.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:f3c85c8c7daf9e2bb6c1\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-A4\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\",\"sensitivity\":\"nA\/ppm at 2ppm SO2 320 to 500\",\"responseTime\":\"t90 (s) from zero to 2ppm SO2 < 20\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"nA\/ppm at 2ppm SO2 320 to 500\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"t90 (s) from zero to 2ppm SO2 < 20\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Small, 4-electrode, low ppb\",\"zh\":\"Alphasense SO2-A4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-so2-a4-01-006103d498.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-a4-306b4d0cd7.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:95660e69d9691d5a2544\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-AE\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm SO2\",\"sensitivity\":\"50\u201380 nA \/ ppm at 400 ppm SO2\",\"responseTime\":\"< 33 s (0 \u2192400 ppm)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 1.5\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm SO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"50\u201380 nA \/ ppm at 400 ppm SO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 33 s (0 \u2192400 ppm)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 1.5\"}],\"description\":{\"en\":\"Small, high-concentration\",\"zh\":\"Alphasense SO2-AE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm SO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-so2-ae-01-94bd131146.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-ae-fa925e0c0e.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:854854de9a8ce489d640\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-AF\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm SO2\",\"sensitivity\":\"300\u2013550 nA \/ ppm at 10 ppm SO2\",\"responseTime\":\"< 35 s (0 \u219210 ppm)\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm SO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"300\u2013550 nA \/ ppm at 10 ppm SO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 35 s (0 \u219210 ppm)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Small, filtered\",\"zh\":\"Alphasense SO2-AF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm SO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-so2-af-01-955a6a90e8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-af-9781701996.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:3a2455105646f631841e\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-B4\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm SO2\",\"sensitivity\":\"275\u2013520 nA \/ ppm at 2 ppm SO2\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm SO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"275\u2013520 nA \/ ppm at 2 ppm SO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Compact, 4-electrode, low ppb\",\"zh\":\"Alphasense SO2-B4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm SO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-so2-b4-01-358634384c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-b4-bf29a3012a.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:22c78f176a5b86eeaf17\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-BE\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132,000 ppm SO2\",\"sensitivity\":\"70\u2013100 nA \/ ppm at 20 ppm SO2\",\"responseTime\":\"< 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132,000 ppm SO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"70\u2013100 nA \/ ppm at 20 ppm SO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 2\"}],\"description\":{\"en\":\"Compact, high-concentration\",\"zh\":\"Alphasense SO2-BE \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132,000 ppm SO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-so2-be-01-c10a9f8fe0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-be-81fa6b2862.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:9bf2c8a61b71db97f378\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-BF\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm SO2\",\"sensitivity\":\"300\u2013480 nA \/ ppm at 20 ppm SO2\",\"responseTime\":\"< 40 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.1\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm SO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"300\u2013480 nA \/ ppm at 20 ppm SO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.1\"}],\"description\":{\"en\":\"Compact, filtered\",\"zh\":\"Alphasense SO2-BF \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm SO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-so2-bf-01-fef461cee8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-bf-6c30719b98.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:1bd8d919a50fde544a1a\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-D4\",\"seriesKey\":\"alphasense:d-series\",\"series\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm SO2\",\"sensitivity\":\"180\u2013420 nA \/ ppm at 10 ppm SO2\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm SO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"180\u2013420 nA \/ ppm at 10 ppm SO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.2\"}],\"description\":{\"en\":\"Miniature Size\",\"zh\":\"Alphasense SO2-D4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm SO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-so2-d4-01-70fa8bd56d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-d4-6c0bbfd200.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:090765ed0ef3645ac58c\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"SO2-H4\",\"seriesKey\":\"alphasense:h-series\",\"series\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm SO2\",\"sensitivity\":\"180\u2013420 nA \/ ppm at 10 ppm SO2\",\"responseTime\":\"< 15 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"RMS noise (ppm equivalent) < 0.2\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm SO2\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"180\u2013420 nA \/ ppm at 10 ppm SO2\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"< 15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"RMS noise (ppm equivalent) < 0.2\"}],\"description\":{\"en\":\"Miniature Size H-series\",\"zh\":\"Alphasense SO2-H4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm SO2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-h-series-general-sensor-1543b36eb7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-so2-h4-670b606f1b.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:e217938b16164a0bb904\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PRHT-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"T_RH_P\",\"gasName\":{\"en\":\"Temperature, Pressure, Humidity\",\"zh\":\"\u6e29\u5ea6 \/ \u76f8\u5bf9\u6e7f\u5ea6 \/ \u6c14\u538b\"},\"tech\":\"DIGITAL_ENVIRONMENTAL\",\"techName\":{\"en\":\"Digital Environmental\",\"zh\":\"\u6570\u5b57\u73af\u5883\u68c0\u6d4b\"},\"specs\":{\"range\":\"Temperature: \u201340 to +80\u00b0C Relative Humidity: 0 \u2013 95 % RH Barometric pressure (absolute, environmental range)\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Temperature: \u201340 to +80\u00b0C Relative Humidity: 0 \u2013 95 % RH Barometric pressure (absolute, environmental range)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Temperature, Pressure and Humidity Sensor\",\"zh\":\"Alphasense PRHT-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6e29\u5ea6 \/ \u76f8\u5bf9\u6e7f\u5ea6 \/ \u6c14\u538b\u7684\u6570\u5b57\u73af\u5883\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a Temperature: \u201340 to +80\u00b0C Relative Humidity: 0 \u2013 95 % RH Barometric pressure (absolute, environmental range)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-prht-a1-2-4ab720ddcb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-prht-rht-f105e832b9.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:a77229d6118a5df05446\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"RHT-A1\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"T_RH\",\"gasName\":{\"en\":\"Temperature, Humidity\",\"zh\":\"\u6e29\u5ea6 \/ \u76f8\u5bf9\u6e7f\u5ea6\"},\"tech\":\"DIGITAL_ENVIRONMENTAL\",\"techName\":{\"en\":\"Digital Environmental\",\"zh\":\"\u6570\u5b57\u73af\u5883\u68c0\u6d4b\"},\"specs\":{\"range\":\"Temperature: \u201340 to +80\u00b0C Relative Humidity: 0\u201395% RH\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Temperature: \u201340 to +80\u00b0C Relative Humidity: 0\u201395% RH\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Temperature and Humidity Sensor\",\"zh\":\"Alphasense RHT-A1 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6e29\u5ea6 \/ \u76f8\u5bf9\u6e7f\u5ea6\u7684\u6570\u5b57\u73af\u5883\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a Temperature: \u201340 to +80\u00b0C Relative Humidity: 0\u201395% RH\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-rht-a1-1-5115a5a460.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-prht-rht-f105e832b9.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:66c5e46d6343b9195f38\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PID-A15\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u20134,000 ppm\",\"sensitivity\":\"0.69\u20131.97 mV \/ ppm\",\"responseTime\":\"(t90 sec) 2\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"100 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20134,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.69\u20131.97 mV \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 2\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"100 ppb\"}],\"description\":{\"en\":\"New Photoionisation detector 0-4,000ppm\",\"zh\":\"Alphasense PID-A15 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20134,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pid-a1-01-r5-b09c678d6e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pid-a15-aeba96c2f9.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:161e9ca70ebad89240fe\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PID-AG5\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201310,000 ppm\",\"sensitivity\":\"> 0.6m V \/ ppm\",\"responseTime\":\"(t90 sec) 5\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"~50 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310,000 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"> 0.6m V \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 5\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"~50 ppb\"}],\"description\":{\"en\":\"New Photoionisation detector 0-10,000ppm\",\"zh\":\"Alphasense PID-AG5 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201310,000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pid-ag-01-r5-8bf263e3bc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pid-ag5-295dd00743.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:93f72a2e7e34d17a8cfb\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PID-AH5\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201340 ppm\",\"sensitivity\":\"25\u201365 mV \/ ppm\",\"responseTime\":\"(t90 sec) 2\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"3 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201340 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"25\u201365 mV \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 2\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"3 ppb\"}],\"description\":{\"en\":\"New Photoionisation detector 0-40ppm\",\"zh\":\"Alphasense PID-AH5 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201340 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pid-ah-01-r5-9ae3622e09.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pid-ah5-ae25e065d7.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:38089906e05359b16335\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PID-AR5\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0-200 ppm\",\"sensitivity\":\"6\u201323 mV \/ ppm\",\"responseTime\":\"(t90 sec) 2\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"~10 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-200 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"6\u201323 mV \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 2\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"~10 ppb\"}],\"description\":{\"en\":\"New Photoionisation detector 0-200ppm\",\"zh\":\"Alphasense PID-AR5 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-200 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pid-ar-01-6609680c38.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pid-ar5-dc830d9b65.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:1eb862dc77ae17134193\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PID-AY5\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"61\u2013184 mV \/ ppm\",\"responseTime\":\"(t90 sec) 4\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"61\u2013184 mV \/ ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 4\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppb\"}],\"description\":{\"en\":\"New Photoionisation detector 0-20ppm\",\"zh\":\"Alphasense PID-AY5 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pid-ay-01-f5afe40376.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pid-ay5-b6f4de841c.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:1ebb1cfcd2738f3091cf\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PIDX-A-004\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0-4 ppm\",\"sensitivity\":\"~625 mV \/ ppm at 1 ppm (see datasheet)\",\"responseTime\":\"(t90 sec) 6.5\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\u22480.5 ppb (typical capability)\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-4 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"~625 mV \/ ppm at 1 ppm (see datasheet)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 6.5\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u22480.5 ppb (typical capability)\"}],\"description\":{\"en\":\"Advanced Photoionisation detector 0-4ppm\",\"zh\":\"Alphasense PIDX-A-004 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-4 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pidx-a-004-a9efb286c4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pidx-a-004-25a8486f3a.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:535a0b70c2491efcdd5d\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PIDX-A-020\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0-20 ppm\",\"sensitivity\":\"~118 mV \/ ppm at 10 ppm\",\"responseTime\":\"(t90 sec) 6.5\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"~118 mV \/ ppm at 10 ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 6.5\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppb\"}],\"description\":{\"en\":\"Advanced Photoionisation detector 0-20ppm\",\"zh\":\"Alphasense PIDX-A-020 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0-20 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pidx-a-020-2426ac524d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pidx-a-020-246790eec0.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:fecc86e2691c16e6e0f4\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PIDX-A-040\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201340 ppm\",\"sensitivity\":\"~55 mV \/ ppm at 10 ppm\",\"responseTime\":\"(t90 sec) 6.5\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201340 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"~55 mV \/ ppm at 10 ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 6.5\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppb\"}],\"description\":{\"en\":\"Advanced Photoionisation detector 0-40ppm\",\"zh\":\"Alphasense PIDX-A-040 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201340 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pidx-a-040-6b5eb19a7c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pidx-a-040-362f6e51ca.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:b39240e9f56194f21deb\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PIDX-A-04K\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u20134,000 ppm (0\u2013400 ppm linear)\",\"sensitivity\":\"~1.8 mV \/ ppm at 100 ppm\",\"responseTime\":\"(t90 sec) 3.5\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"100 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20134,000 ppm (0\u2013400 ppm linear)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"~1.8 mV \/ ppm at 100 ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 3.5\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"100 ppb\"}],\"description\":{\"en\":\"Advanced Photoionisation detector 0-4000ppm\",\"zh\":\"Alphasense PIDX-A-04K \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20134,000 ppm (0\u2013400 ppm linear)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pidx-a-04k-f85f90ef0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pidx-a-04k-4841fa32b4.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:4e3498501d46b172e6f9\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PIDX-A-10K\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201310,000 ppm (0\u2013400 ppm linear)\",\"sensitivity\":\"~0.45 mV \/ ppm at 1,000 ppm\",\"responseTime\":\"(t90 sec) 6.5\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"500 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310,000 ppm (0\u2013400 ppm linear)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"~0.45 mV \/ ppm at 1,000 ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 6.5\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"500 ppb\"}],\"description\":{\"en\":\"Advanced Photoionisation detector 0-10000ppm\",\"zh\":\"Alphasense PIDX-A-10K \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201310,000 ppm (0\u2013400 ppm linear)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pidx-a-10k-6fa1eb129e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pidx-a-10k-c070155686.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:896eb72ee902f822bcba\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"PIDX-A-200\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"~12 mV \/ ppm at 100 ppm\",\"responseTime\":\"(t90 sec) 6.5\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"10 ppb\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"~12 mV \/ ppm at 100 ppm\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"(t90 sec) 6.5\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppb\"}],\"description\":{\"en\":\"Advanced Photoionisation detector 0-200ppm\",\"zh\":\"Alphasense PIDX-A-200 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684PID \u5149\u79bb\u5b50\u68c0\u6d4b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013200 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-pidx-a-200-3c0c506f06.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-pidx-a-200-8e72b76fa5.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:e396406ca850df53d5e5\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"VOC-A4\",\"seriesKey\":\"alphasense:a-series\",\"series\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm VOC (application- dependent; see datasheet)\",\"sensitivity\":\"200\u2013400 nA \/ ppm (typical for ethanol at < 1 ppm)\",\"responseTime\":\"T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm VOC (application- dependent; see datasheet)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"200\u2013400 nA \/ ppm (typical for ethanol at < 1 ppm)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"T90 < 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Electrochemical VOC sensor, A-Series\",\"zh\":\"Alphasense VOC-A4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm VOC (application- dependent; see datasheet)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-voc-a4-3-830c0ad210.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-voc-a4-9d8d8bb65b.pdf\",\"match\":\"exact\"}]},{\"id\":\"alphasense:8bae39fcd99d2ce5839a\",\"brandKey\":\"alphasense\",\"brandName\":\"Alphasense\",\"model\":\"VOC-B4\",\"seriesKey\":\"alphasense:b-series\",\"series\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm VOC (application- dependent; see datasheet)\",\"sensitivity\":\"400\u2013650 nA \/ ppm (typical for ethanol at < 1 ppm)\",\"responseTime\":\"T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm VOC (application- dependent; see datasheet)\"},{\"label\":{\"en\":\"Signal \/ Sensitivity\",\"zh\":\"\u4fe1\u53f7\u5f3a\u5ea6 \/ \u7075\u654f\u5ea6\"},\"value\":\"400\u2013650 nA \/ ppm (typical for ethanol at < 1 ppm)\"},{\"label\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"value\":\"T90 < 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\"}],\"description\":{\"en\":\"Electrochemical VOC sensor, B-Series\",\"zh\":\"Alphasense VOC-B4 \u662f\u4e00\u6b3e\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm VOC (application- dependent; see datasheet)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/images\/alphasense-voc-b4-1-9a91c82491.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/alphasense\/documents\/alphasense-voc-b4-13b98c8b1e.pdf\",\"match\":\"exact\"}]},{\"id\":\"nemoto:fdf31036870dcb40373d\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-180-A\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Acetylene: within 8 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-180-A Acetylene sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-180-A \u4e59\u7094\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-180-a-d83bb76ec6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-180-a-25bf469d5c1b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:ebffa36dffeac6e8030c\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-180-P\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-60% LEL\",\"sensitivity\":\"Acetylene: within 30 mV\",\"responseTime\":\"T90: within 20 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 5 years\"},\"description\":{\"en\":\"Nemoto NCP-180-P Acetylene sensor uses Catalytic Combustion technology and has a measuring range of 0-60% LEL.\",\"zh\":\"Nemoto NCP-180-P \u4e59\u7094\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-60% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-180-p-667e58052b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-180-p-e89f1afc17e3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:7653b93d34b58b6f01f5\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-HCHO-S\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10ppm\",\"sensitivity\":\"350-700nA \/ ppm.HCHO (under 20 \u2103 environment)\",\"responseTime\":\"Within 120 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"More than 1 years\"},\"description\":{\"en\":\"Nemoto NE4-HCHO-S Formaldehyde sensor uses Electrochemical technology and has a measuring range of 0-10ppm.\",\"zh\":\"Nemoto NE4-HCHO-S \u7532\u919b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-10ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-hcho-s-ad4a5febac.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-hcho-s-811f13ee4c34.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:28fb0959dfacbcac6b0e\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-CL2\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10ppm\",\"sensitivity\":\"600 +\/- 150nA \/ ppm. CL2 (under 20 \u2103 environment)\",\"responseTime\":\"Within 40 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-CL2 Chlorine sensor uses Electrochemical technology and has a measuring range of 0-10ppm.\",\"zh\":\"Nemoto NE4-CL2 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-10ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-cl2-f94cbe17dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-cl2-3689a2c35848.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:2dd2ab4599b059ab51f6\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-505\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1000ppm\",\"sensitivity\":\"40 \u00b1 10 nA \/ ppm\",\"responseTime\":\"Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1ppm\/CO\",\"temperature\":\"-30-+ 50 \u2103\",\"humidity\":\"10-95% RH\",\"lifetime\":\"More than 7.5 years\"},\"description\":{\"en\":\"Nemoto NAP-505 Carbon Monoxide sensor uses Electrochemical technology and has a measuring range of 0-1000ppm.\",\"zh\":\"Nemoto NAP-505 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-1000ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-505-4f11589dda.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-505-03a52bae19a1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:36eeeb4ec6b60086d01b\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-508\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-2000ppm\",\"sensitivity\":\"21\u00b15nA\/ppm.CO\",\"responseTime\":\"Within 45 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1ppm\/CO\",\"temperature\":\"-30-+ 50 \u2103\",\"humidity\":\"10-95% RH\",\"lifetime\":\"More than 12 years\"},\"description\":{\"en\":\"Nemoto NAP-508 Carbon Monoxide sensor uses Electrochemical technology and has a measuring range of 0-2000ppm.\",\"zh\":\"Nemoto NAP-508 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-2000ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-508-f6ff26a0b5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-508-8279c610040b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:089ea19b97b35343dd88\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-CO\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1,000ppm\",\"sensitivity\":\"70 \u00b1 15nA \/ ppm.CO (under 20 \u2103 environment)\",\"responseTime\":\"Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-CO Carbon Monoxide sensor uses Electrochemical technology and has a measuring range of 0-1,000ppm.\",\"zh\":\"Nemoto NE4-CO \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-1,000ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-co-9e6049416c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-co-b5879560bda2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:65e90f8a3a31a8d8e09e\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-CO-SI\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1,000ppm\",\"sensitivity\":\"50 +\/- 10nA \/ ppm.CO (under 20 \u2103 environment)\",\"responseTime\":\"Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-CO-SI Carbon Monoxide sensor uses Electrochemical technology and has a measuring range of 0-1,000ppm.\",\"zh\":\"Nemoto NE4-CO-SI \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-1,000ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-co-si-8fb006db50.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-co-si-26e9e22d088a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:10f1a0cdb9c71a3d24b7\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE7-CO-H\",\"seriesKey\":\"nemoto:ne7-d51ecd13\",\"series\":{\"en\":\"NE7\",\"zh\":\"NE7\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1000ppm\",\"sensitivity\":\"100 +\/- 20nA \/ ppm.CO (under 20 \u2103 environment)\",\"responseTime\":\"Within 35 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5ppm\",\"temperature\":\"0-20 degree C\",\"humidity\":\"15-90% RH\",\"lifetime\":\"5 years\"},\"description\":{\"en\":\"Nemoto NE7-CO-H Carbon Monoxide sensor uses Electrochemical technology and has a measuring range of 0-1000ppm.\",\"zh\":\"Nemoto NE7-CO-H \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-1000ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne7-co-h-8b6af7e6fc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne7-co-h-a3065c965870.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:0a6bacdbf6bf6c10dc44\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-21A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"THERMAL_CONDUCTIVITY\",\"techName\":{\"en\":\"Thermal Conductivity\",\"zh\":\"\u70ed\u4f20\u5bfc\u5f0f\"},\"specs\":{\"range\":\"2-100%\",\"sensitivity\":\"CO2 (10%): 1.2\u20132.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-10 ~ + 50 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-21A Carbon Dioxide sensor uses Thermal Conductivity technology and has a measuring range of 2-100%.\",\"zh\":\"Nemoto NAP-21A \u4e8c\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u70ed\u4f20\u5bfc\u5f0f\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 2-100%\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-21a-0a55dbaeea.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-21a-000278741151.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:76030f59eb5601840f09\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-78SU\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"COMBUSTION_EXHAUST\",\"gasName\":{\"en\":\"Incomplete Combustion Exhaust Gas\",\"zh\":\"\u4e0d\u5b8c\u5168\u71c3\u70e7\u5e9f\u6c14\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"Within 1% (including 0.5% hydrogen)\",\"sensitivity\":\"1000ppmCO + 500ppmH2: 5-7mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 200 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-78SU Incomplete Combustion Exhaust Gas sensor uses Catalytic Combustion technology and has a measuring range of Within 1% (including 0.5% hydrogen).\",\"zh\":\"Nemoto NAP-78SU \u4e0d\u5b8c\u5168\u71c3\u70e7\u5e9f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a Within 1% (including 0.5% hydrogen)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-78su-1c9508fed9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-78su-44e60cb86437.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:b58ccb7d45a42da4dfa7\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-80S\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"COMBUSTION_EXHAUST\",\"gasName\":{\"en\":\"Incomplete Combustion Exhaust Gas\",\"zh\":\"\u4e0d\u5b8c\u5168\u71c3\u70e7\u5e9f\u6c14\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"Within 1% (including 0.5% hydrogen)\",\"sensitivity\":\"1000ppmCO + 500ppmH2: 5 -7mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 200 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-80S Incomplete Combustion Exhaust Gas sensor uses Catalytic Combustion technology and has a measuring range of Within 1% (including 0.5% hydrogen).\",\"zh\":\"Nemoto NAP-80S \u4e0d\u5b8c\u5168\u71c3\u70e7\u5e9f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a Within 1% (including 0.5% hydrogen)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-80s-5173a4c749.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-78su-44e60cb86437.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:b51d9570311d7cef7e8b\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-100AH-P\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Hydrogen: 28.0\u201337.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 200 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-100AH-P Hydrogen sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NAP-100AH-P \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-100ah-p-d6bb821840.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-21a-000278741151.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:30334a9df1f750335525\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-180-H\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Hydrogen: within 10 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-180-H Hydrogen sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-180-H \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-180-h-b9e8658dfd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-180-h-54b61cbfbe24.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:b4eb0354371e54e08f9d\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-180S-H\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Hydrogen: within 35 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-180S-H Hydrogen sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-180S-H \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-180s-h-041fbe4e65.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-180s-h-ab8c4466b417.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:82b757761557cf2dd5e9\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-520\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100ppm\",\"sensitivity\":\"120+\/-30nA\/ppm.H2S\",\"responseTime\":\"Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1ppm\/H2S\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NAP-520 Hydrogen Sulfide sensor uses Electrochemical technology and has a measuring range of 0-100ppm.\",\"zh\":\"Nemoto NAP-520 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-520-fb5058e8e5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-520-b740ccb19448.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:45207ab8589a7b35b873\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-523\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-0.5ppm\",\"sensitivity\":\"550 \u00b1 150 nA \/ ppm\",\"responseTime\":\"Within 60 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.06ppm \/ H2S\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NAP-523 Hydrogen Sulfide sensor uses Electrochemical technology and has a measuring range of 0-0.5ppm.\",\"zh\":\"Nemoto NAP-523 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-0.5ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-523-7a3096abd4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-523-2689b9d4b3ed.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:37c76211f47145475758\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-H2S-100\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100ppm\",\"sensitivity\":\"700 +\/- 150nA \/ ppm.H2S (under 20 \u2103 environment)\",\"responseTime\":\"Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-H2S-100 Hydrogen Sulfide sensor uses Electrochemical technology and has a measuring range of 0-100ppm.\",\"zh\":\"Nemoto NE4-H2S-100 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-h2s-100-ed182344dc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-h2s-100-5c90a09e5817.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:76192b30d4c664574687\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE7-H2S\",\"seriesKey\":\"nemoto:ne7-d51ecd13\",\"series\":{\"en\":\"NE7\",\"zh\":\"NE7\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-200ppm\",\"sensitivity\":\"400 +\/- 100nA \/ ppm.H2S (under 20 \u2103 environment)\",\"responseTime\":\"Within 35 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE7-H2S Hydrogen Sulfide sensor uses Electrochemical technology and has a measuring range of 0-200ppm.\",\"zh\":\"Nemoto NE7-H2S \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-200ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne7-h2s-1527ac9d5d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne7-h2s-c30ce1382a08.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:55cadc177a03ba739f55\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE7-H2S-S\",\"seriesKey\":\"nemoto:ne7-d51ecd13\",\"series\":{\"en\":\"NE7\",\"zh\":\"NE7\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10ppm\",\"sensitivity\":\"3000 +\/- 700nA \/ ppm.H2S (under 20 \u2103 environment)\",\"responseTime\":\"Within 35 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.02ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"12 months\"},\"description\":{\"en\":\"Nemoto NE7-H2S-S Hydrogen Sulfide sensor uses Electrochemical technology and has a measuring range of 0-10ppm.\",\"zh\":\"Nemoto NE7-H2S-S \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-10ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne7-h2s-s-1018136dee.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne7-h2s-s-1e7a1251cb75.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:6317763f0819162101fa\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-100AD-P\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: 30.0\u201342.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-100AD-P Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NAP-100AD-P \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-100ad-p-c5ca94a67b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-21a-000278741151.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:f0864a3c1a273d0bfde4\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-100AM\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: 35.0\u201345.0 mV Isobutane: 25.0\u201338.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-100AM Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NAP-100AM \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-100am-4510fe51cf.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-21a-000278741151.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:e2ae67054dc831d058af\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-50A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"Methane: 0-2.5% (0-50% LEL)\",\"sensitivity\":\"Methane: 16.3\u201328.8 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-50A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of Methane: 0-2.5% (0-50% LEL).\",\"zh\":\"Nemoto NAP-50A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a Methane: 0-2.5% (0-50% LEL)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-50a-ffa4bdc749.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-50a-e346b3acba38.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:ec33b66ad45b52fe23c8\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-50AF\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"Methane: 0-2.5% (0-50% LEL)\",\"sensitivity\":\"Methane: 11.3\u201321.3 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-50AF Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of Methane: 0-2.5% (0-50% LEL).\",\"zh\":\"Nemoto NAP-50AF \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a Methane: 0-2.5% (0-50% LEL)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-50af-e0b0244544.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-50af-865273994a62.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:382cba0382e5a2d674b5\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-51A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"Methane: 0-2.5% (0-50% LEL)\",\"sensitivity\":\"Methane: 27.0\u201340.0 mV Isobutane: 15.0\u201324.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-51A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of Methane: 0-2.5% (0-50% LEL).\",\"zh\":\"Nemoto NAP-51A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a Methane: 0-2.5% (0-50% LEL)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-51a-c11d755a52.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-50a-e346b3acba38.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:50a0d7ad172a7b456d5f\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-52A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-50% LEL\",\"sensitivity\":\"Methane: 14.0 \u2013 22.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NAP-52A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-50% LEL.\",\"zh\":\"Nemoto NAP-52A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-50% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-52a-b270997a53.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-52a-4f2633aed460.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:ffaeb8161ff9fd4fa18c\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-55A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"Methane: 0-2.5% (0-50% LEL)\",\"sensitivity\":\"Methane: 16.7\u201328.3 mV Isobutane: 12.9\u201319.3 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-55A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of Methane: 0-2.5% (0-50% LEL).\",\"zh\":\"Nemoto NAP-55A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a Methane: 0-2.5% (0-50% LEL)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-55a-b18dfbe8ad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-55a-949fcf675529.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:661d7bab5f9396e83a43\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-55S\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-50% LEL\",\"sensitivity\":\"Methane: 15.0 \u2013 23.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NAP-55S Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-50% LEL.\",\"zh\":\"Nemoto NAP-55S \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-50% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-55s-2c6291dd4e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-55s-f6b0197816e2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:9f4499522ed14a7df8f9\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-56A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"Methane: 0-2.5% (0-50% LEL)\",\"sensitivity\":\"Methane: 25.0\u201338.3 mV Isobutane: 15.0\u201324.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-56A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of Methane: 0-2.5% (0-50% LEL).\",\"zh\":\"Nemoto NAP-56A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a Methane: 0-2.5% (0-50% LEL)\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-56a-cceedbc068.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-52a-4f2633aed460.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:817d7aa744f4739f49fd\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-57S\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-50% LEL\",\"sensitivity\":\"Methane: 20.0 \u2013 31.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NAP-57S Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-50% LEL.\",\"zh\":\"Nemoto NAP-57S \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-50% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-57s-34c4ffdb14.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-57s-9db2cd2bd47f.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:010eda35ae2389fcdcc9\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-66A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-50% LEL\",\"sensitivity\":\"Isobutane: 12\u201320 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-66A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-50% LEL.\",\"zh\":\"Nemoto NAP-66A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-50% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-66a-0e10fbc213.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-66a-a50512a197ca.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:2c128d7e1af6d4b49208\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-67A\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-50% LEL\",\"sensitivity\":\"Isobutane: 15.0\u201323.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NAP-67A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-50% LEL.\",\"zh\":\"Nemoto NAP-67A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-50% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-67a-44c83e14e8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-67a-fd52d4ee3967.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:b12a46162af99687f49d\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCH-180\",\"seriesKey\":\"nemoto:nch-6be0d417\",\"series\":{\"en\":\"NCH\",\"zh\":\"NCH\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: 10mV\",\"responseTime\":\"T90: Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 70 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 5 years\"},\"description\":{\"en\":\"Nemoto NCH-180 Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCH-180 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nch-180-6949f69525.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nch-180-2df472c9b67f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:18075929afaa0c7a6dc3\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-170\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: Within 13 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-170 Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-170 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-170-62ab81c798.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-170-09548f0e331d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:043a6ef92de3e4de8fac\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-170S\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-60% LEL\",\"sensitivity\":\"Methane: Within 27 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-170S Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-60% LEL.\",\"zh\":\"Nemoto NCP-170S \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-60% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-170s-19e18ce1f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-170s-45af4646082a.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:3739ce4c51ac66802453\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-170S-H\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-60% LEL\",\"sensitivity\":\"Methane: Within 25 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-40 ~ + 150 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-170S-H Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-60% LEL.\",\"zh\":\"Nemoto NCP-170S-H \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-60% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-170s-h-e965e67d9a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-170s-45af4646082a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:35e560d70fcaab54d524\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-180\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: Within 10 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-180 Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-180 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-180-451e19c5c0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-180-h-54b61cbfbe24.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:ad7485b37f71ea3c9011\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-180S-6S\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: 13.0 \u00b1 3.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-180S-6S Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-180S-6S \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-180s-6s-e00052d9f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-180s-6s-823c77cb7058.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:a39586812b87ef75ffae\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-180S-7S\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: 10.0 \u00b1 3.0 mV\",\"responseTime\":\"T90: Within 10 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-180S-7S Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-180S-7S \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-180s-7s-00f5465160.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-180s-7s-98d418382c0e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:c8979a38ec9ed830ffaf\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-300\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100% LEL\",\"sensitivity\":\"Methane: Within 8.8 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-300 Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-100% LEL.\",\"zh\":\"Nemoto NCP-300 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-300-193202cd8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-300-d00af70ac693.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:03ac61f708cdcea65795\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NCP-300S\",\"seriesKey\":\"nemoto:ncp-dbe60238\",\"series\":{\"en\":\"NCP\",\"zh\":\"NCP\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-60% LEL\",\"sensitivity\":\"Methane: Within 23 mV\",\"responseTime\":\"T90: within 8 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 60 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"Within 3 years\"},\"description\":{\"en\":\"Nemoto NCP-300S Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-60% LEL.\",\"zh\":\"Nemoto NCP-300S \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-60% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ncp-300s-53384d9c0f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ncp-300s-878fea98c9bd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:0b0f9f3fa0f9d3e6aca8\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NSU-131A\",\"seriesKey\":\"nemoto:nsu-9db2f9c8\",\"series\":{\"en\":\"NSU\",\"zh\":\"NSU\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u201350% LEL\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"description\":{\"en\":\"Nemoto NSU-131A Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0\u201350% LEL.\",\"zh\":\"Nemoto NSU-131A \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0\u201350% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nsu-131a-b4e6b21f0b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-50af-865273994a62.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:0c02c688b446f8db293f\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NSU-131AF\",\"seriesKey\":\"nemoto:nsu-9db2f9c8\",\"series\":{\"en\":\"NSU\",\"zh\":\"NSU\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-50% LEL\",\"sensitivity\":\"Methane: 17.5\u201333.0 mV\",\"responseTime\":\"T90: Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"\",\"temperature\":\"-20 ~ + 80 \u2103\",\"humidity\":\"Less than 95% RH without condensation\",\"lifetime\":\"5 years or more (in appropriate consumer and small commercial applications)\"},\"description\":{\"en\":\"Nemoto NSU-131AF Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0-50% LEL.\",\"zh\":\"Nemoto NSU-131AF \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-50% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nsu-131af-960bee392f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-50af-865273994a62.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:d3ac0fabc9c090eefb5c\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NSU-131AF2\",\"seriesKey\":\"nemoto:nsu-9db2f9c8\",\"series\":{\"en\":\"NSU\",\"zh\":\"NSU\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u201350% LEL\",\"sensitivity\":\"\",\"responseTime\":\"\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"description\":{\"en\":\"Nemoto NSU-131AF2 Combustible Gas sensor uses Catalytic Combustion technology and has a measuring range of 0\u201350% LEL.\",\"zh\":\"Nemoto NSU-131AF2 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0\u201350% LEL\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nsu-131af2-ac479802f8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-50af-865273994a62.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"This online reference PDF is pending model-by-model review. Confirm the model and measuring range before use.\",\"zh\":\"\u8be5\u8054\u7f51\u53c2\u8003 PDF \u5c1a\u5f85\u9010\u4e00\u5ba1\u67e5\uff0c\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u578b\u53f7\u4e0e\u91cf\u7a0b\u3002\"}},{\"id\":\"nemoto:c17917a46bd13fa69fd8\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-NH3\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100ppm\",\"sensitivity\":\"40 +\/- 12nA \/ ppm.NH3 (under 20 \u2103 environment)\",\"responseTime\":\"Within 90 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1ppm\",\"temperature\":\"-30-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-NH3 Ammonia sensor uses Electrochemical technology and has a measuring range of 0-100ppm.\",\"zh\":\"Nemoto NE4-NH3 \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-100ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-nh3-ee008d95f4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-nh3-6894d1dde2a4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:1cc8d1039ac9fd9486e9\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-NO\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-250ppm\",\"sensitivity\":\"400 +\/- 80nA \/ ppm. NO (under 20 \u2103 environment)\",\"responseTime\":\"Within 40 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.5ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-NO Nitric Oxide sensor uses Electrochemical technology and has a measuring range of 0-250ppm.\",\"zh\":\"Nemoto NE4-NO \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-250ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-no-b951781167.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-no-cae59e612988.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:6389e9a95719616c61ed\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-550\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30ppm\",\"sensitivity\":\"150 +\/- 30nA\/ppm NO2\",\"responseTime\":\"Within 25 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"1ppm\/NO2\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NAP-550 Nitrogen Dioxide sensor uses Electrochemical technology and has a measuring range of 0-30ppm.\",\"zh\":\"Nemoto NAP-550 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-30ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-550-f703a8c70b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-550-57951433b298.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:2994b58be6126a894169\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-NO2\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30ppm\",\"sensitivity\":\"600 +\/- 150nA \/ ppm. NO2 (under 20 \u2103 environment)\",\"responseTime\":\"Within 25 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.1ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-NO2 Nitrogen Dioxide sensor uses Electrochemical technology and has a measuring range of 0-30ppm.\",\"zh\":\"Nemoto NE4-NO2 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-30ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-no2-69584a8214.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-no2-f4168e8af10a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:7a7b3074ae9c649d5531\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE7-NO2\",\"seriesKey\":\"nemoto:ne7-d51ecd13\",\"series\":{\"en\":\"NE7\",\"zh\":\"NE7\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30ppm\",\"sensitivity\":\"720 +\/- 200nA \/ ppm. NO2 (under 20 \u2103 environment)\",\"responseTime\":\"Within 30 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.05ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"12 months\"},\"description\":{\"en\":\"Nemoto NE7-NO2 Nitrogen Dioxide sensor uses Electrochemical technology and has a measuring range of 0-30ppm.\",\"zh\":\"Nemoto NE7-NO2 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-30ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne7-no2-c58ac1b787.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne7-no2-40f3a6adf8f1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:721cdfaad457755e684d\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NE4-O3\",\"seriesKey\":\"nemoto:ne4-7255d757\",\"series\":{\"en\":\"NE4\",\"zh\":\"NE4\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20ppm\",\"sensitivity\":\"600 +\/- 200nA \/ ppm. O3 (under 20 \u2103 environment)\",\"responseTime\":\"Within 60 seconds\",\"responseLabel\":{\"en\":\"Response Time T90\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4 T90\"},\"resolution\":\"0.03ppm\",\"temperature\":\"-20-+ 50 \u2103\",\"humidity\":\"15-90% RH\",\"lifetime\":\"24 months\"},\"description\":{\"en\":\"Nemoto NE4-O3 Ozone sensor uses Electrochemical technology and has a measuring range of 0-20ppm.\",\"zh\":\"Nemoto NE4-O3 \u81ed\u6c27\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0-20ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-ne4-o3-c7471e68f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-ne4-o3-3d9811282c78.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"nemoto:e8ce0913fae694c6e852\",\"brandKey\":\"nemoto\",\"brandName\":\"Nemoto\",\"model\":\"NAP-201\",\"seriesKey\":\"nemoto:nap-82ebadaf\",\"series\":{\"en\":\"NAP\",\"zh\":\"NAP\"},\"gas\":\"R3COH\",\"gasName\":{\"en\":\"Alcohols\",\"zh\":\"\u9187\u7c7b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0~0.4mg\/L\",\"sensitivity\":\"3~20\u03bcA\",\"responseTime\":\"Within 15 seconds\",\"responseLabel\":{\"en\":\"Integration Time (70% Peak)\",\"zh\":\"\u79ef\u5206\u65f6\u95f4\uff0870% \u5cf0\u503c\uff09\"},\"resolution\":\"\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"description\":{\"en\":\"Nemoto NAP-201 Alcohols sensor uses Electrochemical technology and has a measuring range of 0~0.4mg\/L.\",\"zh\":\"Nemoto NAP-201 \u9187\u7c7b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u6280\u672f\uff0c\u91cf\u7a0b\u4e3a 0~0.4mg\/L\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/images\/nemoto-nap-201-a78204080e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/nemoto\/documents\/nemoto-nap-201-be2a9ccda78d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:269b4846c56b46486f0b\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4CH3SH\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"0.70 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"\u2264 40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.70 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4CH3SH methanethiol sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4CH3SH \u7532\u786b\u9187\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4ch3sh-457ccc39de2e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:892e95c4651b2b95bcda\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4Cl2-10\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"0.75 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.75 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4Cl2-10 chlorine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4Cl2-10 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4cl2-10-6d3b2c05e3f9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:f996ad5161c90a0a725d\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4Cl2-200\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.18 \u00b1 0.05 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.18 \u00b1 0.05 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4Cl2-200 chlorine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4Cl2-200 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4cl2-200-ba44cb6dc750.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:a118c1b543ba45106d7b\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4Cl2-50\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"-0.45 \u00b1 0.20 \u00b5A\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"-0.45 \u00b1 0.20 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4Cl2-50 chlorine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4Cl2-50 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4cl2-50-56e4218f13dd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:968fe4d488fa6d3b0ebc\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7Cl2-20\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"0.75 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.75 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 45 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7Cl2-20 chlorine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7Cl2-20 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7cl2-20-a585c8c58ba1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:980fff7af150cc26684d\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7Cl2-50\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.45 \u00b1 0.2 \u00b5A\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.45 \u00b1 0.2 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 45 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7Cl2-50 chlorine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7Cl2-50 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7cl2-50-6b201065d12a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:3dee1bfea0705c2b8287\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4ClO2-1\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"-0.65 \u00b1 0.30 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.03 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"-0.65 \u00b1 0.30 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.03 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4ClO2-1 chlorine dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4ClO2-1 \u4e8c\u6c27\u5316\u6c2f\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4clo2-1-932c5938abe5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:34363142e6891f69f28e\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4ClO2-50\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"-0.40 \u00b1 0.18 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"-0.40 \u00b1 0.18 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.05 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4ClO2-50 chlorine dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4ClO2-50 \u4e8c\u6c27\u5316\u6c2f\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4clo2-50-231643cdd636.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:abq707-400-row\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"ABQ707-400-ROW\",\"seriesKey\":\"honeywell:aq7\",\"series\":{\"en\":\"AQ7\",\"zh\":\"AQ7\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"375 \u00b1 125 nA\/ppm\",\"responseTime\":\"T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppb\",\"temperature\":\"\u221230\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"375 \u00b1 125 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppb\"}],\"description\":{\"en\":\"Four-electrode AQ7 electrochemical sensor for low-level carbon monoxide monitoring. Its high resolution and individual compensation support environmental air-quality and fixed-monitoring applications.\",\"zh\":\"\u7528\u4e8e\u4f4e\u6d53\u5ea6\u4e00\u6c27\u5316\u78b3\u76d1\u6d4b\u7684\u56db\u7535\u6781 AQ7 \u7535\u5316\u5b66\u4f20\u611f\u5668\u3002\u9ad8\u5206\u8fa8\u7387\u4e0e\u5355\u4f53\u8865\u507f\u9002\u5408\u73af\u5883\u7a7a\u6c14\u8d28\u91cf\u53ca\u56fa\u5b9a\u76d1\u6d4b\u5e94\u7528\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-aq7co-0c69448347.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-abq707-400-row-921024d24342.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:aceaa94a599e28255055\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"3CO-500\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.08 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.08 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 3CO-500 carbon monoxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 3CO-500 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-3co-500-e5733ffba4fd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:be910488c124b67a3222\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4CO-2000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.028 \u00b1 0.010 \u00b5A\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.028 \u00b1 0.010 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4CO-2000 carbon monoxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4CO-2000 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4co-2000-3dbc8a5273c3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:88b3fe2709bc36dcc993\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4CO-500\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.070 \u00b1 0.015 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.070 \u00b1 0.015 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4CO-500 carbon monoxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4CO-500 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4co-500-2d326e82746d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:f1ebbffe57a8f262be38\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4CO-LH-500\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.065 \u00b1 0.015 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.065 \u00b1 0.015 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4CO-LH-500 carbon monoxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4CO-LH-500 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4co-lh-500-c032b0954d6b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:d607e00f74a2c3ec3c64\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7CO-1000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.085 \u00b1 0.025 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.085 \u00b1 0.025 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7CO-1000 carbon monoxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7CO-1000 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7co-1000-c60ccc52a5ed.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:40b7e23ba108d077f839\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"mini-CO-2000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.0165 \u00b1 0.0055 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"8 ppm\",\"temperature\":\"\u221240\u201355 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.0165 \u00b1 0.0055 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"8 ppm\"}],\"description\":{\"en\":\"Honeywell S Series mini-CO-2000 carbon monoxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 mini-CO-2000 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-mini-co-2000-04434a5c70d8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:41ad2a3aa3e9c15e6434\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"mini-CO-500\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.050 \u00b1 0.015 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221240\u201355 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.050 \u00b1 0.015 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series mini-CO-500 carbon monoxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 mini-CO-500 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-mini-co-500-07225c2b034f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:cf92da96af34bcd2a22b\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4ETO-10\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"1.9 \u00b1 0.8 \u00b5A\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.9 \u00b1 0.8 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4ETO-10 ethylene oxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4ETO-10 \u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4eto-10-6f7f8f7ccdf0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:1b4ac97987756639e000\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4ETO-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.25 \u00b1 0.125 \u00b5A\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.25 \u00b1 0.125 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4ETO-100 ethylene oxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4ETO-100 \u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4eto-100-1f75d014ce7e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:640afe2b1af4ca97cc54\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4ETO-500\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.058 \u00b1 0.033 \u00b5A\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.058 \u00b1 0.033 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4ETO-500 ethylene oxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4ETO-500 \u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4eto-500-990bcab13366.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:23938cad56f169b77139\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7ETO-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.25 \u00b1 0.125 \u00b5A\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.25 \u00b1 0.125 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7ETO-100 ethylene oxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7ETO-100 \u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7eto-100-dcdfc2d37ae7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:5d078b66892d09d0c4d3\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4H2-1000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.02 \u00b1 0.01 \u00b5A\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.02 \u00b1 0.01 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4H2-1000 hydrogen sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4H2-1000 \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4h2-1000-f3fb0369bcff.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:61cc00ce541b65b33e66\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4H2-40000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201340000 ppm\",\"sensitivity\":\"0.007 \u00b1 0.002 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"80 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201340000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.007 \u00b1 0.002 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"80 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4H2-40000 hydrogen sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4H2-40000 \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4h2-40000-76da997a5658.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:6946c3275ac7629d17e0\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"3H2S-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.8 \u00b1 0.2 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.8 \u00b1 0.2 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 3H2S-100 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 3H2S-100 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-3h2s-100-bd96ffb4c1ee.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:de2fffd285b93677feba\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4H2S-100-1\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.8 \u00b1 0.2 \u00b5A\/ppm\",\"responseTime\":\"\u2264 20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.8 \u00b1 0.2 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4H2S-100-1 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4H2S-100-1 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4h2s-100-1-dde318b5370a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:62594c01d73863ec4a94\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4H2S-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.8 \u00b1 0.2 \u00b5A\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.8 \u00b1 0.2 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4H2S-100 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4H2S-100 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4h2s-100-97c15555fc16.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:be59633f30fc6f1cec31\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4H2S-1000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.105 \u00b1 0.055 \u00b5A\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.105 \u00b1 0.055 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 45 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4H2S-1000 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4H2S-1000 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4h2s-1000-a99374aeb454.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:b024817b4a70790bc589\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4H2S-HR-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"1.3 \u00b1 0.5 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.3 \u00b1 0.5 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4H2S-HR-100 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4H2S-HR-100 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4h2s-hr-100-067cd9603285.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:358d7542e94ab1b70f31\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7H2S-200\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.4 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.4 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7H2S-200 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7H2S-200 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7h2s-200-37f56b56b426.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:49003d841d0e89c98e64\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7H2S-50\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.4 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"\u2264 35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.4 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7H2S-50 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7H2S-50 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7h2s-50-dc7cf6647b1a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:8c8736a1b0c1eee849b4\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"mini-H2S-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.18 \u00b1 0.04 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.4 ppm\",\"temperature\":\"\u221240\u201355 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.18 \u00b1 0.04 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.4 ppm\"}],\"description\":{\"en\":\"Honeywell S Series mini-H2S-100 hydrogen sulfide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 mini-H2S-100 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-mini-h2s-100-99199aa5ba2d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:2c255dd9d2c55abea26e\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4HCL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 ppm\",\"sensitivity\":\"0.3 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.3 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4HCL hydrogen chloride sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4HCL \u6c2f\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4hcl-50cc41397789.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:fbfae250ea26313db128\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7HCL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.33 \u00b1 0.13 \u00b5A\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.33 \u00b1 0.13 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7HCL hydrogen chloride sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7HCL \u6c2f\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7hcl-63584f25022d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:63539d025126ae2c694f\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4HCN\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.2 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4HCN hydrogen cyanide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4HCN \u6c30\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4hcn-df4d2a3dc7b5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:d8aa670cbb9d0ed6f6b7\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7HCN\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.10 \u00b1 0.04 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.04 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.2 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7HCN hydrogen cyanide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7HCN \u6c30\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7hcn-56c10d9184ea.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:09f5fb10f27e436b7809\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"2.3 LEL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"22 \u00b1 8 mV\/%CH4\",\"responseTime\":\"< 20 s (CH4)\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"Not specified by manufacturer\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"22 \u00b1 8 mV\/%CH4\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 20 s (CH4)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Not specified by manufacturer\"}],\"description\":{\"en\":\"Honeywell S Series 2.3 LEL combustible gas sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 2.3 LEL \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-2-3-lel-c203e6090593.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:619bb907340026985859\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"2.3 LEL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"23 \u00b1 7 mV\/%CH4\",\"responseTime\":\"< 20 s (CH4)\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"Not specified by manufacturer\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"23 \u00b1 7 mV\/%CH4\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 20 s (CH4)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Not specified by manufacturer\"}],\"description\":{\"en\":\"Honeywell S Series 2.3 LEL combustible gas sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 2.3 LEL \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-2-3-lel-0605f10986dc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:47ee57282ce36ec50bf9\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"2.3 LEL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"23 \u00b1 7 mV\/%CH4\",\"responseTime\":\"< 20 s (CH4)\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"Not specified by manufacturer\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"23 \u00b1 7 mV\/%CH4\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 20 s (CH4)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Not specified by manufacturer\"}],\"description\":{\"en\":\"Honeywell S Series 2.3 LEL combustible gas sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 2.3 LEL \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-2-3-lel-bc217000d031.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:260a7a88b54ad4ec421b\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4.25 LEL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 \u00b1 9 mV\/%CH4\",\"responseTime\":\"\u2264 20 s (CH4)\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"Not specified by manufacturer\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 \u00b1 9 mV\/%CH4\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 20 s (CH4)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Not specified by manufacturer\"}],\"description\":{\"en\":\"Honeywell S Series 4.25 LEL combustible gas sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4.25 LEL \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4-25-lel-2c997da6d465.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:b7d2237a1f2ae3f745d9\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4.25 LEL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 \u00b1 9 mV\/%CH4\",\"responseTime\":\"< 20 s (CH4)\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"Not specified by manufacturer\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 \u00b1 9 mV\/%CH4\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 20 s (CH4)\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Not specified by manufacturer\"}],\"description\":{\"en\":\"Honeywell S Series 4.25 LEL combustible gas sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4.25 LEL \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4-25-lel-cb99cd2f1237.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:f15f53d20e9fa76cb6b1\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4NH3-100 (0 mV bias)\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.135 \u00b1 0.035 \u00b5A\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"\u2265 1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.135 \u00b1 0.035 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 90 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4NH3-100 (0 mV bias) ammonia sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4NH3-100 (0 mV bias) \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4nh3-100-0-mv-bias-d5674ff3f709.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:587462ef16bb6f7f3c55\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4NH3-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.15 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"\u2264 150 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.15 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 150 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4NH3-100 ammonia sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4NH3-100 \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4nh3-100-8d08b7395f95.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:874b45fdfe4f1a8892b9\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4NH3-500 (0 mV bias)\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.035 \u00b1 0.015 \u00b5A\/ppm\",\"responseTime\":\"\u2264 90 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"3 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.035 \u00b1 0.015 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 90 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"3 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4NH3-500 (0 mV bias) ammonia sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4NH3-500 (0 mV bias) \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4nh3-500-0-mv-bias-d7ed24090448.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:4a1583cf76426a79794b\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7NH3-100\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"\u2264 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"< 0.5 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7NH3-100 ammonia sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7NH3-100 \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7nh3-100-ffa2aa525bf9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:2501bee9a5a79f862479\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7NH3-1000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.025 \u00b1 0.01 \u00b5A\/ppm\",\"responseTime\":\"\u2264 80 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"< 3 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.025 \u00b1 0.01 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 80 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 3 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7NH3-1000 ammonia sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7NH3-1000 \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7nh3-1000-192cf7fa78d7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:7b09d729cd4791cd3797\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4NO-2000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.13 \u00b1 0.06 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.13 \u00b1 0.06 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4NO-2000 nitric oxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4NO-2000 \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4no-2000-8aade862700f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:241b4913224a04eba3ec\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4NO-250\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013250 ppm\",\"sensitivity\":\"0.40 \u00b1 0.08 \u00b5A\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013250 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.40 \u00b1 0.08 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 45 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4NO-250 nitric oxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4NO-250 \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4no-250-fad218cf0fbb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:agq706-400-row\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"AGQ706-400-ROW\",\"seriesKey\":\"honeywell:aq7\",\"series\":{\"en\":\"AQ7\",\"zh\":\"AQ7\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"550 \u00b1 250 nA\/ppm\",\"responseTime\":\"T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"5 ppb\",\"temperature\":\"\u221230\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"550 \u00b1 250 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppb\"}],\"description\":{\"en\":\"Four-electrode AQ7 electrochemical sensor for trace nitrogen dioxide measurement. It provides ppb-level resolution for environmental air-quality and continuous-monitoring instruments.\",\"zh\":\"\u7528\u4e8e\u75d5\u91cf\u4e8c\u6c27\u5316\u6c2e\u6d4b\u91cf\u7684\u56db\u7535\u6781 AQ7 \u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u63d0\u4f9b ppb \u7ea7\u5206\u8fa8\u7387\uff0c\u9002\u5408\u73af\u5883\u7a7a\u6c14\u8d28\u91cf\u4e0e\u8fde\u7eed\u76d1\u6d4b\u4eea\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-aq7nd-da0975eb2a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-agq706-400-row-425b17068a00.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:bee8463aeecc96040c13\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4NO2-20\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4NO2-20 nitrogen dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4NO2-20 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4no2-20-9c79e3c4e26d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:fdccb5beb540d58d8c50\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4NO2-2000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.02 \u00b1 0.01 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.02 \u00b1 0.01 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4NO2-2000 nitrogen dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4NO2-2000 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4no2-2000-62579dc8c1e1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:dcfed4f3fe6c7acb6016\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7NO2-20\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7NO2-20 nitrogen dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7NO2-20 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7no2-20-3088f8d129d5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:8c3f38b2c5a26133d4c5\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4OL\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330% O2\",\"sensitivity\":\"-350 \u00b1 50 \u00b5A in air\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1% O2\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"5\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330% O2\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"-350 \u00b1 50 \u00b5A in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% O2\"}],\"description\":{\"en\":\"Honeywell S Series 4OL oxygen sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4OL \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4ol-ef44fe6aba1a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:0d96b6c1c9da1c14a8aa\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4SPE-O2\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330% O2\",\"sensitivity\":\"-350 \u00b1 50 \u00b5A in air\",\"responseTime\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1% O2\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330% O2\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"-350 \u00b1 50 \u00b5A in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% O2\"}],\"description\":{\"en\":\"Honeywell S Series 4SPE-O2 oxygen sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4SPE-O2 \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4spe-o2-e891f4a1e099.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:8285a7bd0aaddae9a1ed\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"Mini-O2\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330% O2\",\"sensitivity\":\"-85 \u00b1 20 \u00b5A in air\",\"responseTime\":\"\u2264 15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1% O2\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"5\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330% O2\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"-85 \u00b1 20 \u00b5A in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% O2\"}],\"description\":{\"en\":\"Honeywell S Series Mini-O2 oxygen sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 Mini-O2 \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-mini-o2-bf1b14c7ffe0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:asq704-400-row\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"ASQ704-400-ROW\",\"seriesKey\":\"honeywell:aq7\",\"series\":{\"en\":\"AQ7\",\"zh\":\"AQ7\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"500 \u00b1 200 nA\/ppm\",\"responseTime\":\"T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"5 ppb\",\"temperature\":\"\u221230\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"500 \u00b1 200 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppb\"}],\"description\":{\"en\":\"Four-electrode AQ7 electrochemical ozone sensor with an independent electrode for NO2 cross-compensation. It targets ppb-level environmental and continuous ozone monitoring.\",\"zh\":\"\u56db\u7535\u6781 AQ7 \u81ed\u6c27\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u914d\u6709\u72ec\u7acb\u7535\u6781\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u4ea4\u53c9\u8865\u507f\uff0c\u9762\u5411 ppb \u7ea7\u73af\u5883\u4e0e\u8fde\u7eed\u81ed\u6c27\u76d1\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-aq7oz-772b7da0e0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-asq704-400-row-38c30e1f7767.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:a16a6f626dd9b0a57d3f\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4PH3-1000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.07 \u00b1 0.04 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.07 \u00b1 0.04 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4PH3-1000 phosphine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4PH3-1000 \u78f7\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4ph3-1000-57c97bb7e853.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:8e20b9765acf6b4a757e\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4PH3-20\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.4 \u00b1 0.6 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.4 \u00b1 0.6 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4PH3-20 phosphine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4PH3-20 \u78f7\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4ph3-20-e0335fda751e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:be6de732ef95c09e21f8\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7PH3-2000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.07 \u00b1 0.04 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.07 \u00b1 0.04 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7PH3-2000 phosphine sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7PH3-2000 \u78f7\u5316\u6c22\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7ph3-2000-f8f6869187a1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:adq702-400-row\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"ADQ702-400-ROW\",\"seriesKey\":\"honeywell:aq7\",\"series\":{\"en\":\"AQ7\",\"zh\":\"AQ7\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"900 \u00b1 300 nA\/ppm\",\"responseTime\":\"T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"2 ppb\",\"temperature\":\"\u221230\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"900 \u00b1 300 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"< 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppb\"}],\"description\":{\"en\":\"Four-electrode AQ7 electrochemical sensor for low-level sulfur dioxide measurement. Its 2 ppb resolution supports environmental air-quality and continuous-monitoring applications.\",\"zh\":\"\u7528\u4e8e\u4f4e\u6d53\u5ea6\u4e8c\u6c27\u5316\u786b\u6d4b\u91cf\u7684\u56db\u7535\u6781 AQ7 \u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c2 ppb \u5206\u8fa8\u7387\u9002\u5408\u73af\u5883\u7a7a\u6c14\u8d28\u91cf\u4e0e\u8fde\u7eed\u76d1\u6d4b\u5e94\u7528\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-aq7so2-3717d5e6c1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-adq702-400-row-1c94cb4fcbb0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:b96c29434a87fade3ec7\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4SO2-20\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"\u2264 45 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 45 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4SO2-20 sulfur dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4SO2-20 \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4so2-20-d46a256e9d72.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:fa79b5caa7f9886b2880\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4SO2-2000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.020 \u00b1 0.008 \u00b5A\/ppm\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.020 \u00b1 0.008 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 4SO2-2000 sulfur dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4SO2-2000 \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4so2-2000-decd6395efd8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:4fb4f4be06a3ecf39884\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7SO2-20\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"0.34 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.34 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.2 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7SO2-20 sulfur dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7SO2-20 \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7so2-20-8f0bd3ce0039.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:97a96c0a2854ff25e11d\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"7SO2-2000\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.023 \u00b1 0.011 \u00b5A\/ppm\",\"responseTime\":\"\u2264 70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.023 \u00b1 0.011 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppm\"}],\"description\":{\"en\":\"Honeywell S Series 7SO2-2000 sulfur dioxide sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 7SO2-2000 \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-7so2-2000-27fdc3cccf5a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:2eed8110fbcf905761c9\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"4THT\",\"seriesKey\":\"honeywell:s-series\",\"series\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 mg\/m3\",\"sensitivity\":\"0.15 \u00b1 0.05 uA\/(mg\/m3)\",\"responseTime\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.3 mg\/m3\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 mg\/m3\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.15 \u00b1 0.05 uA\/(mg\/m3)\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.3 mg\/m3\"}],\"description\":{\"en\":\"Honeywell S Series 4THT tetrahydrothiophene sensor for industrial gas detection. Key selection data is embedded for multilingual comparison.\",\"zh\":\"Honeywell S \u7cfb\u5217 4THT \u56db\u6c22\u567b\u5429\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5de5\u4e1a\u6c14\u4f53\u68c0\u6d4b\uff1b\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-s-series-92b4f326d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-4tht-134fa54d617f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:c1p-5022-403\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"C1P-5022-403\",\"seriesKey\":\"honeywell:4r-pid\",\"series\":{\"en\":\"4R PID\",\"zh\":\"4R PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"> 3 mV\/ppm @ 100 ppm\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"20 ppb\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201395% RH (NC)\",\"lifetime\":\"5 y \u00b7 UV > 10,000 h\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"> 3 mV\/ppm @ 100 ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 5 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"20 ppb\"}],\"description\":{\"en\":\"Compact 4R-format PID sensor for VOC measurement up to 200 ppm. It combines a fast response with ppb-level resolution for portable and fixed industrial gas instruments.\",\"zh\":\"\u7d27\u51d1\u578b 4R \u5c01\u88c5 PID \u4f20\u611f\u5668\uff0c\u7528\u4e8e 0-200 ppm \u6325\u53d1\u6027\u6709\u673a\u7269\u76d1\u6d4b\u3002\u517c\u5177\u5feb\u901f\u54cd\u5e94\u4e0e ppb \u7ea7\u5206\u8fa8\u7387\uff0c\u9002\u7528\u4e8e\u4fbf\u643a\u5f0f\u53ca\u56fa\u5b9a\u5f0f\u5de5\u4e1a\u6c14\u4f53\u4eea\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-4r-pid-9bc8f3965a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-c1p-5022-403-cf7978485e60.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:c1p-5023-403\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"C1P-5023-403\",\"seriesKey\":\"honeywell:4r-pid\",\"series\":{\"en\":\"4R PID\",\"zh\":\"4R PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"> 0.5 mV\/ppm @ 100 ppm\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"200 ppb\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201395% RH (NC)\",\"lifetime\":\"5 y \u00b7 UV > 10,000 h\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"> 0.5 mV\/ppm @ 100 ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 5 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"200 ppb\"}],\"description\":{\"en\":\"Wide-range 4R-format PID sensor for VOC measurement up to 2000 ppm. It is designed for stable, rapid monitoring in portable and fixed industrial gas instruments.\",\"zh\":\"\u5bbd\u91cf\u7a0b 4R \u5c01\u88c5 PID \u4f20\u611f\u5668\uff0c\u7528\u4e8e 0-2000 ppm \u6325\u53d1\u6027\u6709\u673a\u7269\u76d1\u6d4b\uff0c\u9762\u5411\u4fbf\u643a\u5f0f\u4e0e\u56fa\u5b9a\u5f0f\u5de5\u4e1a\u6c14\u4f53\u4eea\u5668\u7684\u7a33\u5b9a\u5feb\u901f\u68c0\u6d4b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-4r-pid-9bc8f3965a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-c1p-5023-403-76ac3bfa9b5d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"honeywell:c04-0960-011\",\"brandKey\":\"honeywell\",\"brandName\":\"Honeywell\",\"model\":\"C04-0960-011\",\"seriesKey\":\"honeywell:aq7-pid\",\"series\":{\"en\":\"AQ7 PID\",\"zh\":\"AQ7 PID\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"UART 3.3 V TTL \u00b7 \u2264 1 Hz\",\"responseTime\":\"T90 \u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppb\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201395% RH (NC)\",\"lifetime\":\"5 y \u00b7 UV 18,000 h\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"UART 3.3 V TTL \u00b7 \u2264 1 Hz\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u2264 30 s\"},{\"label\":{\"en\":\"Display Resolution\",\"zh\":\"\u663e\u793a\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppb\"}],\"description\":{\"en\":\"Digital AQ7 PID module for trace TVOC monitoring from ppb levels to 20 ppm. Integrated compensation and a UART interface simplify portable and fixed air-quality instrument design.\",\"zh\":\"\u6570\u5b57\u5f0f AQ7 PID \u6a21\u7ec4\uff0c\u53ef\u5bf9 ppb \u7ea7\u81f3 20 ppm \u7684 TVOC \u8fdb\u884c\u76d1\u6d4b\u3002\u5185\u7f6e\u8865\u507f\u4e0e UART \u63a5\u53e3\uff0c\u53ef\u7b80\u5316\u4fbf\u643a\u5f0f\u548c\u56fa\u5b9a\u5f0f\u7a7a\u6c14\u8d28\u91cf\u4eea\u5668\u7684\u8bbe\u8ba1\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/images\/honeywell-aq7-pid-b7226a6123.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/honeywell\/documents\/honeywell-c04-0960-011-99428b537dde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:08c1f7fe108655b8d591\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"AsH3 2E 1\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppb\",\"sensitivity\":\"570 \u00b1 230 nA\/ppm\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 20 ppb\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppb\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"570 \u00b1 230 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 20 ppb\"}],\"description\":{\"en\":\"City Technology SensoriC AsH3 2E 1 arsine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 AsH3 2E 1 \u7837\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ash3-2e-1-ecfde8cd99d5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:37a6abf87fe51e8cc728\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"AsH3 3E 1 F LT\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"1400 \u00b1 450 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"10\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1400 \u00b1 450 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC AsH3 3E 1 F LT arsine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 AsH3 3E 1 F LT \u7837\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ash3-3e-1-f-lt-da2af9f4ea2c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:5650f3cacd54f55d3ba9\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"AsH3 3E 1 LT\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"1400 \u00b1 450 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"10\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1400 \u00b1 450 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC AsH3 3E 1 LT arsine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 AsH3 3E 1 LT \u7837\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ash3-3e-1-lt-3096ff529435.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:e1450240f3e39c3307ca\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"B2H6 3E 1 LT\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"B2H6\",\"gasName\":{\"en\":\"Diborane\",\"zh\":\"\u4e59\u787c\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"2200 \u00b1 500 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"10\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"2200 \u00b1 500 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC B2H6 3E 1 LT diborane sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 B2H6 3E 1 LT \u4e59\u787c\u70f7\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-b2h6-3e-1-lt-f82fc6652f1e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:7c6768ea846925b8ba18\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4AN\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"C3H3N\",\"gasName\":{\"en\":\"Acrylonitrile\",\"zh\":\"\u4e19\u70ef\u8148\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201380 ppm\",\"sensitivity\":\"250 \u00b1 100 nA\/ppm\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201380 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"250 \u00b1 100 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4AN acrylonitrile sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4AN \u4e19\u70ef\u8148\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4an-9b82f1c1ecd8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:8435c73a179ca7b7b157\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3CLH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.00 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T80)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T80\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.00 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T80)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T80\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3CLH chlorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3CLH \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3clh-d05cd3e7acca.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:076bfd8bd9bef5ce4b55\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MCLH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"100 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MCLH chlorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MCLH \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3mclh-ccc36c798074.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:e0ca508d02e985713c4f\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3CLH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T80)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T80\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T80)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T80\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3CLH chlorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3CLH \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3clh-e877721dcda6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:9b0155e5bcc94c02844e\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4CL\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4CL chlorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4CL \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4cl-5a47daf734e6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:daf1499b9d9e2882e6f3\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7CLH\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.00 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.00 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7CLH chlorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7CLH \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7clh-3761756c4e3c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:5885496ed018df33c5fd\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"Cl2 3E 10\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"450 \u00b1 200 nA\/ppm (\u2212)\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"450 \u00b1 200 nA\/ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.05 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC Cl2 3E 10 chlorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 Cl2 3E 10 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-cl2-3e-10-38bb544afb96.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:7413e11776ee41ed38dc\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"CL2 3E 50\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"450 \u00b1 200 nA\/ppm (\u2212)\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"450 \u00b1 200 nA\/ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.05 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC CL2 3E 50 chlorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 CL2 3E 50 \u6c2f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-cl2-3e-50-ee3b6dc63939.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f14f9cab92a40b95d3c8\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"ClO2 3E 1 O\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"600 \u00b1 200 nA\/ppm (\u2212)\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"600 \u00b1 200 nA\/ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.03 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC ClO2 3E 1 O chlorine dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 ClO2 3E 1 O \u4e8c\u6c27\u5316\u6c2f\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-clo2-3e-1-o-3b2721433523.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:8782805e6ac8dc87a0d8\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4COSH\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO_H2S\",\"gasName\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"CO 0\u2013500 ppm \/ H2S 0\u2013200 ppm\",\"sensitivity\":\"CO 80 \u00b1 30 nA\/ppm \/ H2S 775 \u00b1 275 nA\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"CO 1.0 ppm \/ H2S 0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"CO 0\u2013500 ppm \/ H2S 0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"CO 80 \u00b1 30 nA\/ppm \/ H2S 775 \u00b1 275 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"CO 1.0 ppm \/ H2S 0.5 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4COSH carbon monoxide \/ hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4COSH \u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4cosh-b693ebeff697.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:b46a2691f4ecce8bf44e\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"1CO\",\"seriesKey\":\"city:1-series\",\"series\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0.5\u20131000 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0.5\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"50 \u00b1 10 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 1 Series 1CO carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 1 \u7cfb\u5217 1CO \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-1-series-719eb93356.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-1co-ff544d8ff63c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:913b76a7161268d90425\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"2E\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 2E\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 2E\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-2e-f-fba2fa6ab8c7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:92f8cee1513c4548e38d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3E\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3E\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3E\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3e-f-30fcd09eab0e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:1b69d49941992a09ecc2\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3E\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3E carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3E \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3e-0cc904248e05.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:64f6394e2cab1ec90232\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3F\/D\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20134000 ppm\",\"sensitivity\":\"0.030 \u00b1 0.006 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20134000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.030 \u00b1 0.006 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3F\/D carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3F\/D \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3f-d-df6aecfe6f7e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f78fe887fc284e4cf91a\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3F\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20134000 ppm\",\"sensitivity\":\"0.030 \u00b1 0.006 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20134000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.030 \u00b1 0.006 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3F\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3F\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3f-f-d36e41bf7c6c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:edd77714ac7f01044159\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3M\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201340000 ppm\",\"sensitivity\":\"0.007 \u00b1 0.002 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201340000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.007 \u00b1 0.002 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3M carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3M \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3m-296231ff111d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f1fe197fc5346800d42f\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3ME\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"2000 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"2000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3ME\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3ME\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3me-f-89b0abbeb7e9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:333a6d7acf40e6d5cb3d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MF\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201340000 ppm\",\"sensitivity\":\"0.007 \u00b1 0.002 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201340000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.007 \u00b1 0.002 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MF carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MF \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3mf-e8da59ff1672.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:edae61e7957f9b314ed9\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A2E\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.15 \u00b1 0.03 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.15 \u00b1 0.03 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series A2E\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A2E\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a2e-f-a2815df409b6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:e1dbe51d5be308f3b268\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A3CO\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.20 \u00b1 0.04 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"100 ppb\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.20 \u00b1 0.04 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"100 ppb\"}],\"description\":{\"en\":\"City Technology 3 Series A3CO carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A3CO \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a3co-f1554d68623d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:9ff31e665bae1f5a40d0\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A3E\/D\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.075 \u00b1 0.025 \u00b5A\/ppm\",\"responseTime\":\"<38 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.075 \u00b1 0.025 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<38 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series A3E\/D carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A3E\/D \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a3e-d-8bea740350ad.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:1a98e0f121abd14e29e8\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A3E\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.075 \u00b1 0.025 \u00b5A\/ppm\",\"responseTime\":\"<38 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.075 \u00b1 0.025 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<38 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series A3E\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A3E\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a3e-f-3d26e6ce960e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a90ca47b3344745b6f4d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A3ME\/D\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"4000 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5%\",\"responseTime\":\"<38 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"4000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<38 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series A3ME\/D carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A3ME\/D \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a3me-d-567a869e0de0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:60bbdb7158a39f82800c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A3ME\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"4000 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5%\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"4000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series A3ME\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A3ME\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a3me-f-6668fe06ed71.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:8fda795fe63daedd163b\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3E\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 \/ 0\u2013500 \/ 0\u20131000 \/ 0\u20132000 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 \/ 0\u2013500 \/ 0\u20131000 \/ 0\u20132000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3E\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3E\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3e-f-1fb787c7715e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:95a0205a24ef2e43f8b8\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3F\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 \/ 0\u20133000 \/ 0\u20134000 \/ 0\u201310000 \/ 0\u201320000 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 \/ 0\u20133000 \/ 0\u20134000 \/ 0\u201310000 \/ 0\u201320000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3F\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3F\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3f-f-39555e36e7d7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:17933dc76f3b7adb89f7\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"2CF3\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"50 \u00b1 20 nA\/ppm\",\"responseTime\":\"<17 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"50 \u00b1 20 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<17 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 2CF3 carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 2CF3 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-2cf3-59e224663ef3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:4f87a74ae60899e0f383\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4CF+\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.07 \u00b1 0.015 \u00b5A\/ppm\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.07 \u00b1 0.015 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4CF+ carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4CF+ \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4cf-e3988be70cc8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:5df4f604b6550f7dc54c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4CM\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"70 \u00b1 15 nA\/ppm\",\"responseTime\":\"\u226410 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"<1 ppm\",\"temperature\":\"\u221240\u201355 \u00b0C\",\"humidity\":\"15\u201395% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"70 \u00b1 15 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u226410 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4CM carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4CM \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4cm-43d303305eec.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:9344770274e872da6f12\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4F\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310000 ppm\",\"sensitivity\":\"70 \u00b1 15 nA\/ppm\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"<1 ppm\",\"temperature\":\"\u221240\u201355 \u00b0C\",\"humidity\":\"15\u201395% RH\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"70 \u00b1 15 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4f-5654fe0fdb02.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:13086febb0488334d3d1\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4LXH\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"200 \u00b1 65 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"200 \u00b1 65 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4LXH carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4LXH \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4lxh-d3b2e3b4758f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:8745a70ee92bbe0e2f62\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4MF\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201340000 ppm\",\"sensitivity\":\"15 \u00b1 5 nA\/ppm\",\"responseTime\":\"\u226430 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"<1 ppm\",\"temperature\":\"\u221240\u201355 \u00b0C\",\"humidity\":\"15\u201395% RH\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201340000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"15 \u00b1 5 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u226430 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4MF carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4MF \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4mf-bcea819ff2dd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:b81290afd463d23cafa2\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"ECO-SURE X\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"4\u2013500 ppm\",\"sensitivity\":\"50 \u00b1 10 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221210\u201350 \u00b0C\",\"humidity\":\"0\u201399% RH (NC)\",\"lifetime\":\">10 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"4\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"50 \u00b1 10 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series ECO-SURE X carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 ECO-SURE X \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-eco-sure-x-d2d5a030938a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:cfe898341b3f10ce8398\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"ECOSURE\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"45 \u00b1 15 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221210\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\">6 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"45 \u00b1 15 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series ECOSURE carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 ECOSURE \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ecosure-e6362352ffe5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:c7f8879997633a49799c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5F\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20134000 ppm\",\"sensitivity\":\"30 \u00b1 6 nA\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20134000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"30 \u00b1 6 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series 5F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5f-e9d9b9a9769e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:0b4c24497f4c9ee2b199\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5MF\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201340000 ppm\",\"sensitivity\":\"0.010 \u00b1 0.004 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201340000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.010 \u00b1 0.004 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series 5MF carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5MF \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5mf-5f62d775bf86.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:05ad111bfd9ca7870a41\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A5F+\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310000 ppm\",\"sensitivity\":\"60 \u00b1 20 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"60 \u00b1 20 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 5 Series A5F+ carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 A5F+ \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a5f-1ab9cbaee217.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a5f2f5a95bb44d28e15b\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A5F\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"75 \u00b1 25 nA\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"75 \u00b1 25 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 5 Series A5F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 A5F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a5f-64fd8902081c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d9ad77f6ad48f25d5fba\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"TCO\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.062 \u00b1 0.012 \u00b5A\/ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.062 \u00b1 0.012 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series TCO carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 TCO \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-tco-3a2403c1d9cc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:120036cd43aa8ad0ae9d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7E\/F\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 7 Series 7E\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7E\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7e-f-4433620caca7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:83b2d0ce8c3c0c8e4871\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7E\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 7 Series 7E carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7E \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7e-3a53ba976b4b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f3974a189583e38734bc\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A7E\/F\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series A7E\/F carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 A7E\/F \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a7e-f-114b87a09bbe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:c63c280c6d235d88d95a\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A7E\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series A7E carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 A7E \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a7e-3d4c2d767421.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:fd538a3621c5a56c8b97\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"iCO\",\"seriesKey\":\"city:i-series\",\"series\":{\"en\":\"i Series\",\"zh\":\"i \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"UART digital\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"UART digital\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology i Series iCO carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology i \u7cfb\u5217 iCO \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-iseries-co-068c6a6b9a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ico-92f74243db30.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:4b1689e4a7a94388a782\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MICROceL CF\",\"seriesKey\":\"city:microcel-micropel\",\"series\":{\"en\":\"MICROceL \/ MICROpeL\",\"zh\":\"MICROceL \/ MICROpeL\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"0.045 \u00b1 0.01 \u00b5A\/ppm\",\"responseTime\":\"15\u201320 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.045 \u00b1 0.01 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"15\u201320 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology MICROceL \/ MICROpeL MICROceL CF carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology MICROceL \/ MICROpeL MICROceL CF \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-microcel-micropel-8a911ff4ab.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-microcel-cf-f3af2c81dc53.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a2cbae57a7239c795b05\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"CO 3E 300\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"70 \u00b1 20 nA\/ppm\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 3 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">4 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"70 \u00b1 20 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 3 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC CO 3E 300 carbon monoxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 CO 3E 300 \u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-co-3e-300-22898c2fc824.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:10e84dd2098ae1d80cbc\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"COCl2 3E 1\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"COCL2\",\"gasName\":{\"en\":\"Phosgene\",\"zh\":\"\u5149\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"650 \u00b1 150 nA\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"650 \u00b1 150 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.02 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC COCl2 3E 1 phosgene sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 COCl2 3E 1 \u5149\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-cocl2-3e-1-a8476df3af57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:49fc4013e7077d23676a\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3ETO\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"2.75 \u00b1 0.5 \u00b5A\/ppm\",\"responseTime\":\"<140 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"2.75 \u00b1 0.5 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<140 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3ETO ethylene oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3ETO \u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3eto-2a87a7685ff4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:658a187f357dc9281d04\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4ETO\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.9 \u00b1 0.5 \u00b5A\/ppm\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.9 \u00b1 0.5 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4ETO ethylene oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4ETO \u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4eto-dcc73c9b0243.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:682300dea7e28722d2d9\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7ETO\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"2.25 \u00b1 0.65 \u00b5A\/ppm\",\"responseTime\":\"<140 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"2.25 \u00b1 0.65 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<140 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7ETO ethylene oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7ETO \u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7eto-905f1dd8282a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f112477bc5dc570aa77d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"F2 3E 1\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"F2\",\"gasName\":{\"en\":\"Fluorine\",\"zh\":\"\u6c1f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"1000 nA\/ppm \u00b1 300 nA\/ ppm (\u2212)\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"\u221210\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1000 nA\/ppm \u00b1 300 nA\/ ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.02 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC F2 3E 1 fluorine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 F2 3E 1 \u6c1f\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-f2-3e-1-d52809247707.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:4d5e0a791c0654a10163\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3HYE\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310000 ppm\",\"sensitivity\":\"3 \u00b1 1 nA\/ppm\",\"responseTime\":\"<70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"3 \u00b1 1 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3HYE hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3HYE \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3hye-134b80ba36b1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:0b99c8f7316d6796a859\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3HYT\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"30 \u00b1 10 nA\/ppm\",\"responseTime\":\"<50 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"30 \u00b1 10 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<50 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3HYT hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3HYT \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3hyt-5a081d906b3f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:59a54da5e88f6e2b3229\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MHYT\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"2000 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5%\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"2000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MHYT hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MHYT \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3mhyt-682b773d8a50.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d8385d165520b35b3c7c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3HYE\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320000 \/ 0\u201350000 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320000 \/ 0\u201350000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3HYE hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3HYE \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3hye-5cb69ad17bf9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:3401590e514c982b0090\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3HYT\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 \/ 0\u2013300 \/ 0\u2013500 \/ 0\u20131000 \/ 0\u20132000 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 \/ 0\u2013300 \/ 0\u2013500 \/ 0\u20131000 \/ 0\u20132000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3HYT hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3HYT \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3hyt-fca2669ebed2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d0afdf16662522769ca3\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4HYT\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"15 \u00b1 10 nA\/ppm\",\"responseTime\":\"<90 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"15 \u00b1 10 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<90 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4HYT hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4HYT \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4hyt-b4615ec085b6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:9f3444dc606739fc0e34\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7HYE\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310000 ppm\",\"sensitivity\":\"0.003 \u00b1 0.001 \u00b5A\/ppm\",\"responseTime\":\"<110 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"10 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.003 \u00b1 0.001 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<110 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7HYE hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7HYE \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7hye-16df55caa704.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:8ffe5ee3534b67f7080a\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7HYT\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.03 \u00b1 0.01 \u00b5A\/ppm\",\"responseTime\":\"<85 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"2 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.03 \u00b1 0.01 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<85 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7HYT hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7HYT \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7hyt-f4ca7fb19c8a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:fc9518e3de2888084fcc\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"H2 3E 1%\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310000 ppm\",\"sensitivity\":\"10 \u00b1 5 nA\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 20 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"10 \u00b1 5 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 20 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC H2 3E 1% hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 H2 3E 1% \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-h2-3e-1-434272c09001.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:ac22c49a8f5fb6df7baf\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"H2 3E 4%\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20134% (100% LEL)\",\"sensitivity\":\"1 \u00b1 0.5 nA\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 100 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20134% (100% LEL)\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 \u00b1 0.5 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 100 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC H2 3E 4% hydrogen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 H2 3E 4% \u6c22\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-h2-3e-4-3b37d29aa1bd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:dfdf740ff0aa9c0df756\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"1H2S\",\"seriesKey\":\"city:1-series\",\"series\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0.5\u2013200 ppm\",\"sensitivity\":\"175 \u00b1 35 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0.5\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"175 \u00b1 35 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 1 Series 1H2S hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 1 \u7cfb\u5217 1H2S \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-1-series-719eb93356.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-1h2s-092a19311c99.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:bee08f3f4df87632b7bc\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3H\/LM\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<70 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<70 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3H\/LM hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3H\/LM \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3h-lm-5886800f25e9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:58d4afd84593ec412095\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3H\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3H hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3H \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3h-623ea8376017.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a5c4eb66f4677412b9a2\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3HH\/LM\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"1.70 \u00b1 0.30 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.70 \u00b1 0.30 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3HH\/LM hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3HH\/LM \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3hh-lm-d239bea1dfc1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:631f72ef62f92272472c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013250 \/ 0\u2013200 ppm\",\"sensitivity\":\"1 \/ 10 mV\/ppm (\u00b15%)\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013250 \/ 0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 \/ 10 mV\/ppm (\u00b15%)\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MH hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MH \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3mh-387d337aa2bc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:02f259fa6d024899cc38\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3H\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3H hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3H \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3h-c4725f83b4b3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:243d9015406ca212d832\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4H\/LM\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"1.20 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.20 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4H\/LM hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4H\/LM \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4h-lm-028c03d6a020.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:646109df38bca2352a53\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4H\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"1.20 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.20 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4H hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4H \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4h-bebcb21d8a79.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:fdf8f147ed0b88441b6e\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4HS\/LM\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.70 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"\u226430 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.70 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"\u226430 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4HS\/LM hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4HS\/LM \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4hs-lm-98384d775e0f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:0dd9b3347d83d1029ab3\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4HS+\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.7 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.7 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4HS+ hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4HS+ \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4hs-9b628c12548a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:9be6a18066bf9b3be42d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7H\/LM\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7H\/LM hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7H\/LM \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7h-lm-adaa7bb58736.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:055f2304e542cb387bfc\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7H\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.25 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.25 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7H hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7H \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7h-0666ab95af67.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a9cf95c83aa1b61f40ad\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7HH\/LM\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"1.7 \u00b1 0.3 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.7 \u00b1 0.3 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7HH\/LM hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7HH\/LM \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7hh-lm-b52af25cb63b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f833aa0e00d87c820e34\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7HH\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"1.7 \u00b1 0.3 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.7 \u00b1 0.3 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7HH hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7HH \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7hh-51f32834b412.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:44c0c8760184d15e8376\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"iH2S HC\",\"seriesKey\":\"city:i-series\",\"series\":{\"en\":\"i Series\",\"zh\":\"i \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"UART digital\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"UART digital\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology i Series iH2S HC hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology i \u7cfb\u5217 iH2S HC \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-iseries-h2s-b53b9a5faa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ih2s-hc-22668722ce0d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a5b81fb1c5fef9732e06\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"iH2S\",\"seriesKey\":\"city:i-series\",\"series\":{\"en\":\"i Series\",\"zh\":\"i \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"UART digital\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"UART digital\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology i Series iH2S hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology i \u7cfb\u5217 iH2S \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-iseries-h2s-b53b9a5faa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ih2s-7c5c671a411f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:c33e1b6f9723199973d5\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MICROceL HS\",\"seriesKey\":\"city:microcel-micropel\",\"series\":{\"en\":\"MICROceL \/ MICROpeL\",\"zh\":\"MICROceL \/ MICROpeL\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.105 \u00b1 0.025 \u00b5A\/ppm\",\"responseTime\":\"25\u201340 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.105 \u00b1 0.025 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"25\u201340 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology MICROceL \/ MICROpeL MICROceL HS hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology MICROceL \/ MICROpeL MICROceL HS \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-microcel-micropel-8a911ff4ab.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-microcel-hs-8f8e6a848cd1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:c169c0b33dfc855b7245\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"H2S 2E 50 S\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"380 nA\/ppm \u00b1 80 nA\/ ppm\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.7 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">4 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"380 nA\/ppm \u00b1 80 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.7 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC H2S 2E 50 S hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 H2S 2E 50 S \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-h2s-2e-50-s-ca4aa43d222a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d7ed00214bfbfe2d2473\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"H2S 3E 100 S\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"750 nA\/ppm \u00b1 150 nA\/ ppm\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"\u221240\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">4 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"750 nA\/ppm \u00b1 150 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.3 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC H2S 3E 100 S hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 H2S 3E 100 S \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-h2s-3e-100-s-3504a8e118d8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:45901c010112ace78b17\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"H2S 3E 100\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"750 nA\/ppm \u00b1 150 nA\/ ppm\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.3 ppm\",\"temperature\":\"\u221240\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">4 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"750 nA\/ppm \u00b1 150 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.3 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC H2S 3E 100 hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 H2S 3E 100 \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-h2s-3e-100-a94b6a2f5cf3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:94f371f4b2d748a1c0c7\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"H2S 3E 2000 S Transmitter\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.01 mA\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201395% RH (NC)\",\"lifetime\":\">1.3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 mA\"}],\"description\":{\"en\":\"City Technology SensoriC H2S 3E 2000 S Transmitter hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 H2S 3E 2000 S Transmitter \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-h2s-3e-2000-s-transmitter-9801a1aeb8d6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:5794693ea08de1c301f9\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"H2S 3E 2000 S\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"60 \u00b1 25 nA\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"<7 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\">1.3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"60 \u00b1 25 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<7 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC H2S 3E 2000 S hydrogen sulfide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 H2S 3E 2000 S \u786b\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-h2s-3e-2000-s-51239d7a84c9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f355d56a3f3067ba3a1e\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"SeH2 3E 5 LT\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"H2SE\",\"gasName\":{\"en\":\"Hydrogen Selenide\",\"zh\":\"\u7852\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"1100 \u00b1 500 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"10\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1100 \u00b1 500 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC SeH2 3E 5 LT hydrogen selenide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 SeH2 3E 5 LT \u7852\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-seh2-3e-5-lt-044b048fa2b5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:4facddfd977e86e66095\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"HCl\/HBr 3E 30\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"HCL_HBR\",\"gasName\":{\"en\":\"Hydrogen Chloride \/ Hydrogen Bromide\",\"zh\":\"\u6c2f\u5316\u6c22 \/ \u6eb4\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 ppm\",\"sensitivity\":\"140 nA\/ppm \u00b1 60 nA\/ ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.7 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"140 nA\/ppm \u00b1 60 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.7 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC HCl\/HBr 3E 30 hydrogen chloride \/ hydrogen bromide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 HCl\/HBr 3E 30 \u6c2f\u5316\u6c22 \/ \u6eb4\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-hcl-hbr-3e-30-ca6d5631b4cc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:34fe41ac0c61c1d54ef4\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3HL\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.75 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.75 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3HL hydrogen chloride sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3HL \u6c2f\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3hl-a81e594f0f97.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:579f055db84d5f552237\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MHL\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"100 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MHL hydrogen chloride sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MHL \u6c2f\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3mhl-d3a270837393.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:87c7783ad33acebf55fa\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3HL\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 \/ 0\u201320 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 \/ 0\u201320 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3HL hydrogen chloride sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3HL \u6c2f\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3hl-04fac6c29afb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:cab41549b6db7cba375c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7HL\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.75 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.75 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7HL hydrogen chloride sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7HL \u6c2f\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7hl-48ac4ce4607c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:53c0a11beff4e8c50385\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3HCN\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<200 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<200 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3HCN hydrogen cyanide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3HCN \u6c30\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3hcn-61b1d278919a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a09954794e334ba148db\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4HN\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<200 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<200 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4HN hydrogen cyanide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4HN \u6c30\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4hn-cf9c1104aa82.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:078fe6acd8771a422633\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7HCN\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<200 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<200 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7HCN hydrogen cyanide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7HCN \u6c30\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7hcn-e33b14b0d134.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:aa4f48408da34224bb89\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"HCN 2E 30 F\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 ppm\",\"sensitivity\":\"30 nA\/ ppm \u00b1 15 nA\/ ppm\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"\u221240\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"30 nA\/ ppm \u00b1 15 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.2 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC HCN 2E 30 F hydrogen cyanide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 HCN 2E 30 F \u6c30\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-hcn-2e-30-f-768ae7012cd6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:5694d744fd9baecd82f1\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"HCN 3E 30 F\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 ppm\",\"sensitivity\":\"60 nA\/ ppm \u00b1 15 nA\/ ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.2 ppm\",\"temperature\":\"\u221240\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"60 nA\/ ppm \u00b1 15 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.2 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC HCN 3E 30 F hydrogen cyanide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 HCN 3E 30 F \u6c30\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-hcn-3e-30-f-713b85e99b91.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:1de737ad349281a2d66c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"HF 3E 10 SE\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"300 \u00b1 100 nA\/ppm (\u2212)\",\"responseTime\":\"<90 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"< 150 ppb\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"300 \u00b1 100 nA\/ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<90 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 150 ppb\"}],\"description\":{\"en\":\"City Technology SensoriC HF 3E 10 SE hydrogen fluoride sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 HF 3E 10 SE \u6c1f\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-hf-3e-10-se-8ebf927e0466.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:7f94269bc4e1ec52bdd5\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"1LEL75\",\"seriesKey\":\"city:1-series\",\"series\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 mV\/%CH \u00b1 5 mV\/%CH\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 % LEL\",\"temperature\":\"\",\"humidity\":\"0\u201395% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 mV\/%CH \u00b1 5 mV\/%CH\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 % LEL\"}],\"description\":{\"en\":\"City Technology 1 Series 1LEL75 combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 1 \u7cfb\u5217 1LEL75 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-1-series-719eb93356.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-1lel75-d22c03159c93.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:ca36c873f5ae566cc2f1\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"1LEL75C\",\"seriesKey\":\"city:1-series\",\"series\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 mV\/%CH \u00b1 5 mV\/%CH\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 % LEL\",\"temperature\":\"\",\"humidity\":\"0\u201395% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 mV\/%CH \u00b1 5 mV\/%CH\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 % LEL\"}],\"description\":{\"en\":\"City Technology 1 Series 1LEL75C combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 1 \u7cfb\u5217 1LEL75C \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-1-series-719eb93356.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-1lel75c-05b19deaf11b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:eec9e9df74432c145349\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"1LEL75M\",\"seriesKey\":\"city:1-series\",\"series\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 mV\/%CH \u00b1 5 mV\/%CH\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 % LEL\",\"temperature\":\"\",\"humidity\":\"0\u201395% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 mV\/%CH \u00b1 5 mV\/%CH\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 % LEL\"}],\"description\":{\"en\":\"City Technology 1 Series 1LEL75M combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 1 \u7cfb\u5217 1LEL75M \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-1-series-719eb93356.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-1lel75m-74a48229fb57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:86a66de8030f9b54d1cb\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P50\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"37 \u00b1 7 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"37 \u00b1 7 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P50 combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P50 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p50-ce77402aa32b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:b7365f31291022f72a32\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P50C\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"37 \u00b1 7 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"37 \u00b1 7 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P50C combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P50C \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p50c-1dcc679b9858.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:323f39b0b262abb88820\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P50M\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"37 \u00b1 7 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"37 \u00b1 7 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P50M combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P50M \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p50m-d1258225e0e1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:be0e76902c53bef4b602\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P75\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"24 \u00b1 4 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"24 \u00b1 4 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P75 combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P75 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p75-94b2296777c5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:af539e9416e5c7450cc6\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P75C T4\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"24 \u00b1 4 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"24 \u00b1 4 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P75C T4 combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P75C T4 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p75c-t4-c8b3864671c3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:7e949e5d11e47bad6c08\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P75C\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"24 \u00b1 4 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"24 \u00b1 4 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P75C combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P75C \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p75c-c7e0aa685b7f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d73a9e096950b0ba55ee\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P75M\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"24 \u00b1 4 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"24 \u00b1 4 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P75M combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P75M \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p75m-c2e0281bed70.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:31cffa246b09f2ec2a80\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P90\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"28 \u00b1 5 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"28 \u00b1 5 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P90 combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P90 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p90-f6e11e57895a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:c00e8ea2dcb156601725\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P90C\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"28 \u00b1 5 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"28 \u00b1 5 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P90C combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P90C \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p90c-7aa821707ece.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:9ead1c043992add8bfdd\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4P90M\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"28 \u00b1 5 mV\/%methane\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"28 \u00b1 5 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology 4 Series 4P90M combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4P90M \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4p90m-73ad214944aa.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:425bf59fe3e446a917bc\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"iLEL\",\"seriesKey\":\"city:i-series\",\"series\":{\"en\":\"i Series\",\"zh\":\"i \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"UART digital\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 % LEL\",\"temperature\":\"\u221220\u201360 \u00b0C\",\"humidity\":\"0\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"UART digital\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 % LEL\"}],\"description\":{\"en\":\"City Technology i Series iLEL combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology i \u7cfb\u5217 iLEL \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-iseries-lel-c7b57c987b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ilel-e392ba174a49.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:6b3e450f293758f98356\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MICROpel 75\",\"seriesKey\":\"city:microcel-micropel\",\"series\":{\"en\":\"MICROceL \/ MICROpeL\",\"zh\":\"MICROceL \/ MICROpeL\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 \u00b1 5 mV\/%methane\",\"responseTime\":\"<5 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 \u00b1 5 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<5 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology MICROceL \/ MICROpeL MICROpel 75 combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology MICROceL \/ MICROpeL MICROpel 75 \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-microcel-micropel-8a911ff4ab.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-micropel-75-0296b5777260.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:bc023a6696f96ad5f119\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MICROpel 75C\",\"seriesKey\":\"city:microcel-micropel\",\"series\":{\"en\":\"MICROceL \/ MICROpeL\",\"zh\":\"MICROceL \/ MICROpeL\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 \u00b1 5 mV\/%methane\",\"responseTime\":\"<5 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 \u00b1 5 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<5 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology MICROceL \/ MICROpeL MICROpel 75C combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology MICROceL \/ MICROpeL MICROpel 75C \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-microcel-micropel-8a911ff4ab.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-micropel-75c-d8b8488fb364.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:02253f7dd7086924666f\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MICROpel 75M\",\"seriesKey\":\"city:microcel-micropel\",\"series\":{\"en\":\"MICROceL \/ MICROpeL\",\"zh\":\"MICROceL \/ MICROpeL\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100% LEL\",\"sensitivity\":\"31 \u00b1 5 mV\/%methane\",\"responseTime\":\"<5 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1% LEL\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"0\u201390% RH (NC)\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% LEL\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"31 \u00b1 5 mV\/%methane\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<5 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1% LEL\"}],\"description\":{\"en\":\"City Technology MICROceL \/ MICROpeL MICROpel 75M combustible gas sensor using catalytic combustion detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology MICROceL \/ MICROpeL MICROpel 75M \u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u91c7\u7528\u50ac\u5316\u71c3\u70e7\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-microcel-micropel-8a911ff4ab.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-micropel-75m-55ffd3d956ef.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:6f89e9e84abd82405dfb\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"TBM 2E 50\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"MERCAPTAN\",\"gasName\":{\"en\":\"Mercaptan\",\"zh\":\"\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 mg\/m\u00b3 \/ 0\u201314 ppm\",\"sensitivity\":\"3\u20138 nA\/(mg\/m\u00b3)\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"<0.5 mg\/m\u00b3\",\"temperature\":\"\u221210\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 mg\/m\u00b3 \/ 0\u201314 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"3\u20138 nA\/(mg\/m\u00b3)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<0.5 mg\/m\u00b3\"}],\"description\":{\"en\":\"City Technology SensoriC TBM 2E 50 mercaptan sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 TBM 2E 50 \u786b\u9187\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-tbm-2e-50-f18228f27523.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:caf103865cae56b24216\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"N2H4 2E 1\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"N2H4\",\"gasName\":{\"en\":\"Hydrazine\",\"zh\":\"\u80bc\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"1200 nA\/ppm \u00b1 300 nA\/ ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"\u221210\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1200 nA\/ppm \u00b1 300 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC N2H4 2E 1 hydrazine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 N2H4 2E 1 \u80bc\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-n2h4-2e-1-9cc0960db0ad.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:24e263ab9cfc5b1faf92\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NH3 3E 100 SE\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"130 \u00b1 30 nA\/ppm\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 1 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"130 \u00b1 30 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 1 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC NH3 3E 100 SE ammonia sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NH3 3E 100 SE \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-nh3-3e-100-se-7a471749af8d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:10217fb6d0ac791d2282\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NH3 3E 100\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"90 \u00b1 40 nA\/ppm\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"<2 ppm\",\"temperature\":\"\u221240\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"90 \u00b1 40 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<2 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC NH3 3E 100 ammonia sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NH3 3E 100 \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-nh3-3e-100-6d4603c1d34b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:67dc74562a01c092951c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NH3 3E 1000 SE\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"8 \u00b1 4 nA\/ppm\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 12 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"8 \u00b1 4 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 12 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC NH3 3E 1000 SE ammonia sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NH3 3E 1000 SE \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-nh3-3e-1000-se-3f9ec6270621.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a3f5bd10d034a82811e6\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NH3 3E 1000\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"6 \u00b1 3 nA\/ppm\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"<15 ppb\",\"temperature\":\"\u221240\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"6 \u00b1 3 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<120 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<15 ppb\"}],\"description\":{\"en\":\"City Technology SensoriC NH3 3E 1000 ammonia sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NH3 3E 1000 \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-nh3-3e-1000-d5b9b7e32f3d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:800aab5f72a1f0c79682\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NH3 3E 500 SE\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"35 \u00b1 15 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"35 \u00b1 15 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC NH3 3E 500 SE ammonia sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NH3 3E 500 SE \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-nh3-3e-500-se-bf188f9635f4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:15823e495f70f3c71e86\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NH3 3E 5000 SE\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135000 ppm\",\"sensitivity\":\"4 \u00b1 2 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"<50 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"4 \u00b1 2 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<50 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC NH3 3E 5000 SE ammonia sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NH3 3E 5000 SE \u6c28\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-nh3-3e-5000-se-e8d3955ad1ef.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:8d63ea89826c7ac2cb99\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MNF\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"5000 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5%\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"5000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MNF\/F nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MNF\/F \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3mnf-f-a270df85aa8f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:7a78a77aae6564910885\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3NF\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 3 Series 3NF\/F nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3NF\/F \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3nf-f-4a9d23def081.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:badfd7639e296df9bda0\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3NT\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.55 \u00b1 0.11 \u00b5A\/ppm\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.55 \u00b1 0.11 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 3 Series 3NT nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3NT \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3nt-1f311af6727e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:846485cf14a36617726a\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MNO-1\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.25 \u00b1 0.05 \u00b5A\/ppm\",\"responseTime\":\"<100 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.25 \u00b1 0.05 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<100 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 3 Series MNO-1 nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 MNO-1 \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-mno-1-8e367b529f26.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:75011b7c88bfaca86d9e\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3NF\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 \/ 0\u2013500 \/ 0\u20132000 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 \/ 0\u2013500 \/ 0\u20132000 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3NF\/F nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3NF\/F \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3nf-f-35381f7f8da7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:acaa847f6203363dac5d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3NT\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3NT nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3NT \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3nt-8c4eff2b8136.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f4525abf2be014834b14\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4NT\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013250 ppm\",\"sensitivity\":\"0.40 \u00b1 0.08 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013250 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.40 \u00b1 0.08 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4NT nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4NT \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4nt-f9351da98a00.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f715e72a0da03c5fa3ca\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5NF\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"3 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series 5NF nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5NF \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5nf-151b5ec16703.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:2a2c69e3052935c89a83\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5NFL\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013300 ppm\",\"sensitivity\":\"\u00b1 0.08 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013300 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"\u00b1 0.08 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 5 Series 5NFL nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5NFL \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5nfl-837c823d38de.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:01e7f9f4f2a93180d4b7\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7NT\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.55 \u00b1 0.11 \u00b5A\/ppm\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.55 \u00b1 0.11 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7NT nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7NT \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7nt-c5826dc54f46.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:cafe645642dc43fa084d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MNO-2\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.25 \u00b1 0.05 \u00b5A\/ppm\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"0.25 \u00b1 0.05 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 7 Series MNO-2 nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 MNO-2 \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-mno-2-b2a611f47337.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:3694f934b42700a257d0\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NO 3E 100\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm \/ 0\u2013500 ppm\",\"sensitivity\":\"45 nA\/ppm \u00b1 15 nA\/ ppm\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.7 ppm\",\"temperature\":\"\u221215\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm \/ 0\u2013500 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"45 nA\/ppm \u00b1 15 nA\/ ppm\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.7 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC NO 3E 100 nitric oxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NO 3E 100 \u4e00\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-no-3e-100-84216683ee8f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:ea0b00f911fd97c0cf58\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MNDH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"200 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5% \/ 10 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MNDH nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MNDH \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3mndh-d9ffedee250d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:15c6597f4f297e24d936\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3ND\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3ND nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3ND \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3nd-b5d6b1618523.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d1a872f35ac5aaf5892c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3NDH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.4 \u00b1 0.3 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.4 \u00b1 0.3 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3NDH nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3NDH \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3ndh-6d2259f265ea.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:ee79a3657ee67a446cab\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MND-1S\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"<50 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<50 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 3 Series MND-1S nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 MND-1S \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-mnd-1s-d29ae56dd094.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:b8b3bbee54e978ab3a1e\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3ND\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013300 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013300 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3ND nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3ND \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3nd-0f6f324617c7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f6d90701f9c5dd7e5634\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3NDH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 \/ 0\u2013300 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3NDH nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3NDH \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3ndh-de41ab3e39a9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:4a3ef6f8c431fcfe4986\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4ND\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.60 \u00b1 0.15 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4ND nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4ND \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4nd-5c557f89a176.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:c1341b24490b098540ba\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5ND\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series 5ND nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5ND \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5nd-1a92c05015ab.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:2fbf8a8bb2457b090bdf\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7NDH\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.4 \u00b1 0.3 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.4 \u00b1 0.3 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7NDH nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7NDH \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7ndh-f75deafe4688.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:696cf7a9e65df8cdb16d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"MND-2\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"1 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 7 Series MND-2 nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 MND-2 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-mnd-2-448048fec719.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:e0ba048708b1cc63d4f3\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"NO2 3E 50\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"200 \u00b1 40 nA\/ppm (\u2212)\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"200 \u00b1 40 nA\/ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.1 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC NO2 3E 50 nitrogen dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 NO2 3E 50 \u4e8c\u6c27\u5316\u6c2e\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-no2-3e-50-86e7ec3da09f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:0bb81c64198c4bca6e01\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"1O2\",\"seriesKey\":\"city:1-series\",\"series\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0.6\u201325% vol.\",\"sensitivity\":\"80\u2013130 \u00b5A in air\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0.6\u201325% vol.\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"80\u2013130 \u00b5A in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 1 Series 1O2 oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 1 \u7cfb\u5217 1O2 \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-1-series-719eb93356.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-1o2-ea09f65941e7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f59e9fb9408fdca43bea\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4OXLL Emissions\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"80\u2013130 \u00b5A in air\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"7 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"80\u2013130 \u00b5A in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4OXLL Emissions oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4OXLL Emissions \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4oxll-emissions-57c39f232402.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d41466dde669ba772aaf\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4OXLL Industrial\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"80\u2013130 \u00b5A in air\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"80\u2013130 \u00b5A in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4OXLL Industrial oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4OXLL Industrial \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4oxll-industrial-c30ed92cda68.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f17ceff3fd78dc996a62\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4OXV\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"1\u201325% vol.\",\"sensitivity\":\"0.10 \u00b1 0.02 mA in air\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"0.10 \u00b1 0.02 mA in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4OXV oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4OXV \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4oxv-f1a0c6059f7f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:81c3ed4d8f7e98dbf66b\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5FO\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"0.41 \u00b1 0.05 mA in air\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T95)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T95\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201345 \u00b0C\",\"humidity\":\"0\u201399% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"0.41 \u00b1 0.05 mA in air\"},{\"label\":{\"en\":\"Response Time (T95)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T95\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 5 Series 5FO oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5FO \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5fo-3ba24c829dfa.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:7143ebca732eb1473696\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5OXLL\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"80\u2013130 \u00b5A in air\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"7 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"80\u2013130 \u00b5A in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 5 Series 5OXLL oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5OXLL \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5oxll-f41654a05af1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:dbbcd46b6a7d3dd8cccf\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7OXV\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"0.195\u20130.25 mA in air\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"0\u201399% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"0.195\u20130.25 mA in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 7 Series 7OXV oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7OXV \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7oxv-e994064bb843.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:86ecfaeb7be7be3b6f8d\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T7OXV\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T95)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T95\uff09\"},\"resolution\":\"0.1% vol.\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"0\u201399% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T95)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T95\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% vol.\"}],\"description\":{\"en\":\"City Technology 7 Series T7OXV oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 T7OXV \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t7oxv-be59a2b71b48.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:1681795beb6068c6e296\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"iO2\",\"seriesKey\":\"city:i-series\",\"series\":{\"en\":\"i Series\",\"zh\":\"i \u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"UART digital\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1% O2\",\"temperature\":\"\u221240\u201360 \u00b0C\",\"humidity\":\"5\u201395% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"UART digital\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% O2\"}],\"description\":{\"en\":\"City Technology i Series iO2 oxygen sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology i \u7cfb\u5217 iO2 \u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-iseries-o2-2c2f6d6725.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-io2-e5b64bdcd79f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f7ee4a3b370bf77681a3\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3OZ\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132 ppm\",\"sensitivity\":\"7.2 \u00b5A\/ppm \u00b1 20%\",\"responseTime\":\"<150 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"20 ppb\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"7.2 \u00b5A\/ppm \u00b1 20%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<150 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"20 ppb\"}],\"description\":{\"en\":\"City Technology 3 Series 3OZ ozone sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3OZ \u81ed\u6c27\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3oz-0797fcbf3597.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a786a9017269720ad570\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A3OZ\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"2.2 \u00b1 0.5 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"20 ppb\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"2.2 \u00b1 0.5 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"20 ppb\"}],\"description\":{\"en\":\"City Technology 3 Series A3OZ ozone sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A3OZ \u81ed\u6c27\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a3oz-4ad2177c081f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:b791f1d2a7dd1757b39f\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7OZ\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132 ppm\",\"sensitivity\":\"7.2 \u00b1 2.3 \u00b5A\/ppm\",\"responseTime\":\"<150 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"20 ppb\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"7.2 \u00b1 2.3 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<150 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"20 ppb\"}],\"description\":{\"en\":\"City Technology 7 Series 7OZ ozone sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7OZ \u81ed\u6c27\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7oz-725730530fd6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:17af98f063a76298ff8b\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"O3 3E 1 F\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"450 \u00b1 150 nA\/ppm (\u2212)\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.03 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"450 \u00b1 150 nA\/ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.03 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC O3 3E 1 F ozone sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 O3 3E 1 F \u81ed\u6c27\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-o3-3e-1-f-10da1e7bce10.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:0f9cf5148dbecd0e5325\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"O3 3E 1\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"1000\u20132000 nA\/ppm (\u2212)\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1000\u20132000 nA\/ppm (\u2212)\"},{\"label\":{\"en\":\"Response Time (T50)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T50\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.02 ppm\"}],\"description\":{\"en\":\"City Technology SensoriC O3 3E 1 ozone sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 O3 3E 1 \u81ed\u6c27\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-o3-3e-1-64480e601f7d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:000523d1bb4ff259857f\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4PH-Fast\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"1.7 \u00b1 0.3 \u00b5A\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"< 0.05 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.7 \u00b1 0.3 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.05 ppm\"}],\"description\":{\"en\":\"City Technology 4 Series 4PH-Fast phosphine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4PH-Fast \u78f7\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4ph-fast-b5cafc063a69.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d3532d2c115c982f731a\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"PH3 3E 5 F LT\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"2000 \u00b1 500 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"10\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"2000 \u00b1 500 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC PH3 3E 5 F LT phosphine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 PH3 3E 5 F LT \u78f7\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ph3-3e-5-f-lt-8357aed05220.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:e8550d75ca594d4b1b51\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"PH3 3E 5 LT\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"2200 \u00b1 500 nA\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"10\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"2200 \u00b1 500 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC PH3 3E 5 LT phosphine sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 PH3 3E 5 LT \u78f7\u5316\u6c22\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ph3-3e-5-lt-fe6cef523453.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:91f90e35ac694db8129c\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"SiH4 3E 50 LT\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"130 \u00b1 70 nA\/ppm\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201340 \u00b0C\",\"humidity\":\"10\u201395% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"130 \u00b1 70 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<60 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC SiH4 3E 50 LT silane sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 SiH4 3E 50 LT \u7845\u70f7\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-sih4-3e-50-lt-6d269f7fe159.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:4cfebc7c8f561bd30fe0\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"1SO2\",\"seriesKey\":\"city:1-series\",\"series\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0.1\u201320 ppm\",\"sensitivity\":\"160 \u00b1 40 nA\/ppm\",\"responseTime\":\"<10 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0.1\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"160 \u00b1 40 nA\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<10 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 1 Series 1SO2 sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 1 \u7cfb\u5217 1SO2 \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-1-series-719eb93356.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-1so2-3deac5572175.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:398eef1d26c6f988a240\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3MSF\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"5000 ppm\",\"sensitivity\":\"1 mV\/ppm \u00b1 5%\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221215\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"5000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1 mV\/ppm \u00b1 5%\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3MSF sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3MSF \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3msf-9340fdf193cb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f90677d2c0eda81c3635\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3SC\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3SC sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3SC \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3sc-b35add77b622.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:2515547f573ba49a985b\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3SF\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3SF\/F sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3SF\/F \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3sf-f-e626e655dc11.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a1d7f274819cd0ecdf44\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3SF\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3SF sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3SF \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3sf-24e7f691eb07.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:c0471c5cb9c086a1d837\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3SH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.25 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.25 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3SH sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3SH \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3sh-04c899f5c5b4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:737a07be3d16a813f065\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"3ST\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<50 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<50 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series 3ST\/F sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 3ST\/F \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-3st-f-8521b36a54a5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:6b66a79467a958bbd89a\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"A3ST\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"0.60 \u00b1 0.12 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.60 \u00b1 0.12 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 3 Series A3ST\/F sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 A3ST\/F \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-a3st-f-e5700661bece.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:05cbec46da082edb0844\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3S\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 \/ 0\u2013300 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 \/ 0\u2013300 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3S\/F sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3S\/F \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3s-f-474ac8c28c6c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:415965fd1921878e27ed\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3SH\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 \/ 0\u201310 \/ 0\u201320 \/ 0\u201330 \/ 0\u2013100 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 \/ 0\u201310 \/ 0\u201320 \/ 0\u201330 \/ 0\u2013100 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3SH sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3SH \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3sh-dc778a0bcd84.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:a3ab82d0ab974cc4326f\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"T3ST\/F\",\"seriesKey\":\"city:3-series\",\"series\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 \/ 0\u201320 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 ppm\",\"sensitivity\":\"4\u201320 mA DC\",\"responseTime\":\"<20 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 \/ 0\u201320 \/ 0\u201330 \/ 0\u201350 \/ 0\u2013100 \/ 0\u2013200 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"4\u201320 mA DC\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<20 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 3 Series T3ST\/F sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 3 \u7cfb\u5217 T3ST\/F \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-3-series-2e27b41321.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-t3st-f-5068fd2c747c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:d90e0c945cd6415fe204\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"4S Rev.2\",\"seriesKey\":\"city:4-series\",\"series\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.5 \u00b1 0.1 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<25 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology 4 Series 4S Rev.2 sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 4 \u7cfb\u5217 4S Rev.2 \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-4-series-aafc1f5426.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-4s-rev-2-7985879ea401.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:f9aaf491b259139f2fe1\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5SC\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<35 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<35 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series 5SC sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5SC \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5sc-fd69893aa4f8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:78c4701ddcd687479a47\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5SF\/F\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<40 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<40 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series 5SF\/F sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5SF\/F \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5sf-f-a878bed7d9a0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:82918fad674da8795515\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"5SF\",\"seriesKey\":\"city:5-series\",\"series\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.10 \u00b1 0.02 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"City Technology 5 Series 5SF sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 5 \u7cfb\u5217 5SF \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-5-series-4fd24c2395.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-5sf-c042d7152cfe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:e6af34338bb3d68c3dd3\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7SH\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"1.25 \u00b1 0.25 \u00b5A\/ppm\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"1.25 \u00b1 0.25 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<15 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7SH sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7SH \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7sh-4248cebf5b13.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:188f2d84213afa34f28f\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"7ST\/F\",\"seriesKey\":\"city:7-series\",\"series\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"2 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"0.37 \u00b1 0.07 \u00b5A\/ppm\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"City Technology 7 Series 7ST\/F sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology 7 \u7cfb\u5217 7ST\/F \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-7-series-64b841e3bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-7st-f-562c08392368.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:6ffd2dc0e301ceb403ba\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"iSO2\",\"seriesKey\":\"city:i-series\",\"series\":{\"en\":\"i Series\",\"zh\":\"i \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"UART digital\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"15\u201390% RH (NC)\",\"lifetime\":\"5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"UART digital\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"City Technology i Series iSO2 sulfur dioxide sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology i \u7cfb\u5217 iSO2 \u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-iseries-so2-20a6dbd0dc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-iso2-f5630fe367ec.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:215b5d5a41737ef18c42\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"THT 3E 50\",\"seriesKey\":\"city:sensoric\",\"series\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 mg\/m\u00b3\",\"sensitivity\":\"140 \u00b1 50 nA\/mg\/m\u00b3\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\">1.5 y\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 mg\/m\u00b3\"},{\"label\":{\"en\":\"Sensitivity\",\"zh\":\"\u7075\u654f\u5ea6\"},\"value\":\"140 \u00b1 50 nA\/mg\/m\u00b3\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<30 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology SensoriC THT 3E 50 tetrahydrothiophene sensor using electrochemical detection. Official selection data is embedded for multilingual comparison.\",\"zh\":\"City Technology SensoriC \u7cfb\u5217 THT 3E 50 \u56db\u6c22\u567b\u5429\u4f20\u611f\u5668\uff0c\u91c7\u7528\u7535\u5316\u5b66\u68c0\u6d4b\uff1b\u5b98\u65b9\u5173\u952e\u9009\u578b\u53c2\u6570\u5df2\u5185\u5d4c\uff0c\u4fbf\u4e8e\u591a\u8bed\u8a00\u5bf9\u6bd4\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-sensoric-45e778385e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-tht-3e-50-9a280349236b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"city:5f17aec1fbf493db41eb\",\"brandKey\":\"city\",\"brandName\":\"City Technology\",\"model\":\"AO2\",\"partNumber\":\"AA428-210\",\"seriesKey\":\"city:automotive-emissions\",\"series\":{\"en\":\"Automotive &#038; Emissions\",\"zh\":\"\u6c7d\u8f66\u4e0e\u6392\u653e\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Partial Pressure Electrochemical\",\"zh\":\"\u5206\u538b\u5f0f\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100% vol. O\u2082\",\"sensitivity\":\"9\u201313 mV in air\",\"signal\":\"9\u201313 mV in air\",\"responseTime\":\"<5 s\",\"responseLabel\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"resolution\":\"\u2014\",\"temperature\":\"\u221220\u201350 \u00b0C\",\"humidity\":\"0\u201399% RH (NC)\",\"lifetime\":\"2 y in air at STP\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100% vol. O\u2082\"},{\"label\":{\"en\":\"Output Signal\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7\"},\"value\":\"9\u201313 mV in air\"},{\"label\":{\"en\":\"Response Time (T90)\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\uff08T90\uff09\"},\"value\":\"<5 s\"},{\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"City Technology AO2 CiTiceL oxygen sensor (part AA428-210) uses partial-pressure electrochemical sensing for vehicle exhaust analysis, with linear output across 0\u2013100% O\u2082.\",\"zh\":\"City Technology AO2 CiTiceL \u6c27\u6c14\u4f20\u611f\u5668\uff08\u8ba2\u8d27\u53f7 AA428-210\uff09\u91c7\u7528\u5206\u538b\u5f0f\u7535\u5316\u5b66\u539f\u7406\uff0c\u9002\u7528\u4e8e\u6c7d\u8f66\u5c3e\u6c14\u5206\u6790\uff0c\u5e76\u5728 0\u2013100% O\u2082 \u8303\u56f4\u5185\u63d0\u4f9b\u7ebf\u6027\u8f93\u51fa\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/images\/city-ao2-6f037edf6c74.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/city\/documents\/city-ao2-e2684bf1e96b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs1820\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS1820\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"ACETONE\",\"gasName\":{\"en\":\"Acetone\",\"zh\":\"\u4e19\u916e\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201320 ppm\",\"sensitivity\":\"Vb (air): \u2212370 to \u2212290 mV; \u0394V (1 ppm acetone): 20\u201360 mV; sensitivity ratio: 1.4\u20132.5\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201320 ppm\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Vb (air): \u2212370 to \u2212290 mV; \u0394V (1 ppm acetone): 20\u201360 mV; sensitivity ratio: 1.4\u20132.5\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS1820 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Acetone measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS1820 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e19\u916e\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs1820-0fc1590af618.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs1820-946d78590ff3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs3870\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS3870\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"CH4_CO\",\"gasName\":{\"en\":\"Methane \/ Carbon Monoxide\",\"zh\":\"\u7532\u70f7 \/ \u4e00\u6c27\u5316\u78b3\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"CH\u2084: 1\u201325 %LEL; CO: 50\u20131,000 ppm\",\"sensitivity\":\"Rs(3,000 ppm CH\u2084) \/ Rs(1,000 ppm): 0.44\u20130.70\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"CH\u2084: 1\u201325 %LEL; CO: 50\u20131,000 ppm\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(3,000 ppm CH\u2084) \/ Rs(1,000 ppm): 0.44\u20130.70\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS3870 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Methane \/ Carbon Monoxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS3870 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u70f7 \/ \u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs3870-45b3714a0709.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs3870-400e1f216dc3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:ngm2611-e13\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"NGM2611-E13\",\"seriesKey\":\"figaro:ngm\",\"series\":{\"en\":\"NGM Natural Gas Module\",\"zh\":\"NGM \u5929\u7136\u6c14\u6a21\u7ec4\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"Alarm set point: 5,000 ppm CH\u2084\",\"sensitivity\":\"VOUT: 2.5 \u00b1 0.5 V @ 5,000 ppm methane\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Alarm set point: 5,000 ppm CH\u2084\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"VOUT: 2.5 \u00b1 0.5 V @ 5,000 ppm methane\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"NGM2611-E13 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Methane measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"NGM2611-E13 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u70f7\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-ngm2611-e13-51fd664cbb3f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-ngm2611-e13-bbe62322ccaf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2611-c00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2611-C00\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201325 %LEL\",\"sensitivity\":\"Rs(9,000 ppm methane) \/ Rs(3,000 ppm): 0.54\u20130.66\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201325 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(9,000 ppm methane) \/ Rs(3,000 ppm): 0.54\u20130.66\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2611-C00 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Methane measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2611-C00 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u70f7\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2611-c00-e456d16f1067.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2611-c00-973a01800d66.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2611-e00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2611-E00\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201325 %LEL\",\"sensitivity\":\"Rs(9,000 ppm methane) \/ Rs(3,000 ppm): 0.52\u20130.65\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201325 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(9,000 ppm methane) \/ Rs(3,000 ppm): 0.52\u20130.65\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2611-E00 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Methane measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2611-E00 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u70f7\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2611-e00-f3a6bcd6ccf4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2611-e00-110c76252cc0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs8410\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS8410\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201325 %LEL\",\"sensitivity\":\"Rs(3,000 ppm methane) \/ Rs(1,000 ppm): 0.48\u20130.68\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201325 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(3,000 ppm methane) \/ Rs(1,000 ppm): 0.48\u20130.68\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS8410 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Methane measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS8410 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u70f7\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs8410-d751e62ecf4b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs8410-ef5910f9fb26.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs45-10\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS45-10\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm Cl\u2082\",\"sensitivity\":\"\u2212600 \u00b1 150 nA\/ppm\",\"responseTime\":\"<60 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm Cl\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"\u2212600 \u00b1 150 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"FECS45-10 is a Figaro Electrochemical sensor for Chlorine measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS45-10 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs45-10-2d9a98a7b2ea.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs45-10-8624d32a26b9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:cmm5042\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"CMM5042\",\"seriesKey\":\"figaro:cmm\",\"series\":{\"en\":\"CMM CO Module\",\"zh\":\"CMM \u4e00\u6c27\u5316\u78b3\u6a21\u7ec4\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013800 ppm CO\",\"sensitivity\":\"VCONC: 0\u20132 V DC\",\"responseTime\":\"\u226460 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013800 ppm CO\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"VCONC: 0\u20132 V DC\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226460 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"CMM5042 is a Figaro Electrochemical sensor for Carbon Monoxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"CMM5042 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-cmm5042-d88110eb1899.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-cmm5042-03902394d48f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs40-1000\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS40-1000\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131,000 ppm CO\",\"sensitivity\":\"70 \u00b1 15 nA\/ppm\",\"responseTime\":\"<30 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131,000 ppm CO\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"70 \u00b1 15 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"FECS40-1000 is a Figaro Electrochemical sensor for Carbon Monoxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS40-1000 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs40-1000-66e2896e3c0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs40-1000-f9391d456b2e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs5042-a00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS5042-A00\",\"seriesKey\":\"figaro:tgs-electrochemical\",\"series\":{\"en\":\"TGS Electrochemical Series\",\"zh\":\"TGS \u7535\u5316\u5b66\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310,000 ppm CO\",\"sensitivity\":\"1.2\u20132.4 nA\/ppm\",\"responseTime\":\"\u226460 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310,000 ppm CO\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"1.2\u20132.4 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226460 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS5042-A00 is a Figaro Electrochemical sensor for Carbon Monoxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS5042-A00 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs5042-a00-ecf4f98eb217.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs5042-a00-f2d471fa4276.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs5141-p00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS5141-P00\",\"seriesKey\":\"figaro:tgs-electrochemical\",\"series\":{\"en\":\"TGS Electrochemical Series\",\"zh\":\"TGS \u7535\u5316\u5b66\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm CO\",\"sensitivity\":\"1.2\u20133.2 nA\/ppm\",\"responseTime\":\"\u226460 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm CO\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"1.2\u20133.2 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226460 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS5141-P00 is a Figaro Electrochemical sensor for Carbon Monoxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS5141-P00 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs5141-p00-9f1cfe9979eb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs5141-p00-8757875b6387.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:cdm7162-c00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"CDM7162-C00\",\"seriesKey\":\"figaro:cdm\",\"series\":{\"en\":\"CDM CO\u2082 Module\",\"zh\":\"CDM \u4e8c\u6c27\u5316\u78b3\u6a21\u7ec4\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"},\"specs\":{\"range\":\"360\u20135,000 ppm CO\u2082\",\"sensitivity\":\"UART \/ I\u00b2C; PWM 1 kHz, 0\u2013100 % duty\",\"responseTime\":\"90 s (T90, diffusion)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Accuracy: \u00b1(50 ppm + 3 % of reading)\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"360\u20135,000 ppm CO\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"UART \/ I\u00b2C; PWM 1 kHz, 0\u2013100 % duty\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"90 s (T90, diffusion)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Accuracy: \u00b1(50 ppm + 3 % of reading)\"}],\"description\":{\"en\":\"CDM7162-C00 is a Figaro Non-dispersive Infrared (NDIR) sensor for Carbon Dioxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"CDM7162-C00 \u662f Figaro \u7684\u975e\u5206\u6563\u7ea2\u5916\uff08NDIR\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u78b3\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-cdm7162-c00-a4b1da7cfb80.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-cdm7162-c00-c02136c7455e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:cgm6812-b00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"CGM6812-B00\",\"seriesKey\":\"figaro:cgm\",\"series\":{\"en\":\"CGM Combustible Gas Module\",\"zh\":\"CGM \u53ef\u71c3\u6c14\u4f53\u6a21\u7ec4\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u201314,000 ppm H\u2082\",\"sensitivity\":\"VCONC: 1\u20134.5 V DC typical\",\"responseTime\":\"\u226430 s (T90) @ 4,000 ppm H\u2082\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201314,000 ppm H\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"VCONC: 1\u20134.5 V DC typical\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430 s (T90) @ 4,000 ppm H\u2082\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"CGM6812-B00 is a Figaro Catalytic sensor for Hydrogen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"CGM6812-B00 \u662f Figaro \u7684\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-cgm6812-b00-09b8d3352fe4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-cgm6812-b00-0e4aa7c2b1ad.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2616-c00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2616-C00\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"30\u20134,000 ppm H\u2082\",\"sensitivity\":\"Rs(1,000 ppm H\u2082) \/ Rs(100 ppm): 0.25\u20130.60\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"30\u20134,000 ppm H\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(1,000 ppm H\u2082) \/ Rs(100 ppm): 0.25\u20130.60\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2616-C00 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Hydrogen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2616-C00 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2616-c00-51f3dcaf5e2d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2616-c00-5fd08c06fc20.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2616-c01\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2616-C01\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"30\u20134,000 ppm H\u2082\",\"sensitivity\":\"Rs(1,000 ppm H\u2082) \/ Rs(100 ppm): 0.25\u20130.60\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"30\u20134,000 ppm H\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(1,000 ppm H\u2082) \/ Rs(100 ppm): 0.25\u20130.60\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2616-C01 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Hydrogen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2616-C01 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2616-c00-51f3dcaf5e2d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2616-c01-2267be0c632f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs50-100\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS50-100\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm H\u2082S\",\"sensitivity\":\"700 \u00b1 150 nA\/ppm\",\"responseTime\":\"<30 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm H\u2082S\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"700 \u00b1 150 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"FECS50-100 is a Figaro Electrochemical sensor for Hydrogen Sulfide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS50-100 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs50-100-57afa0936d2e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs50-100-00dcd633128c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs6810-d00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS6810-D00\",\"seriesKey\":\"figaro:tgs-catalytic\",\"series\":{\"en\":\"TGS Catalytic Series\",\"zh\":\"TGS \u50ac\u5316\u71c3\u70e7\u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100 %LEL\",\"sensitivity\":\"\u0394Vout (methane, 5,000 ppm): 10\u201318 mV\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"\u0394Vout (methane, 5,000 ppm): 10\u201318 mV\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS6810-D00 is a Figaro Catalytic sensor for Combustible Gas measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS6810-D00 \u662f Figaro \u7684\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs6810-d00-86dde72e9a7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs6810-d00-3e7884b5eee1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs6812-d00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS6812-D00\",\"seriesKey\":\"figaro:tgs-catalytic\",\"series\":{\"en\":\"TGS Catalytic Series\",\"zh\":\"TGS \u50ac\u5316\u71c3\u70e7\u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0\u2013100 %LEL\",\"sensitivity\":\"\u0394Vout (hydrogen, 4,000 ppm): 8\u201316 mV\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"\u0394Vout (hydrogen, 4,000 ppm): 8\u201316 mV\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS6812-D00 is a Figaro Catalytic sensor for Combustible Gas measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS6812-D00 \u662f Figaro \u7684\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs6812-d00-9606ddfcd57d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs6812-d00-15b1d70a4cab.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2612-d00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2612-D00\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201325 %LEL\",\"sensitivity\":\"Rs(9,000 ppm methane) \/ Rs(3,000 ppm): 0.47\u20130.60\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201325 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(9,000 ppm methane) \/ Rs(3,000 ppm): 0.47\u20130.60\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2612-D00 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Combustible Gas (Methane \/ LP Gas) measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2612-D00 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\uff08\u7532\u70f7 \/ \u6db2\u5316\u77f3\u6cb9\u6c14\uff09\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2612-d00-fbe84ac12f6d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2612-d00-2340fd30e7b2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:lpm2610-d09\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"LPM2610-D09\",\"seriesKey\":\"figaro:lpm\",\"series\":{\"en\":\"LPM LP Gas Module\",\"zh\":\"LPM \u6db2\u5316\u6c14\u6a21\u7ec4\"},\"gas\":\"LPG\",\"gasName\":{\"en\":\"LP Gas\",\"zh\":\"\u6db2\u5316\u77f3\u6cb9\u6c14\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"0\u20137,200 ppm iso-butane\",\"sensitivity\":\"VOUT: 0.05\u20134.0 V DC\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20137,200 ppm iso-butane\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"VOUT: 0.05\u20134.0 V DC\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"LPM2610-D09 is a Figaro Metal Oxide Semiconductor (MOS) sensor for LP Gas measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"LPM2610-D09 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6db2\u5316\u77f3\u6cb9\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-lpm2610-d09-bbfb44de066b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-lpm2610-d09-11207cd7ff7a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2610-c00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2610-C00\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"LPG\",\"gasName\":{\"en\":\"LP Gas (Butane \/ Propane)\",\"zh\":\"\u6db2\u5316\u77f3\u6cb9\u6c14\uff08\u4e01\u70f7 \/ \u4e19\u70f7\uff09\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201325 %LEL\",\"sensitivity\":\"Rs(3,000 ppm iso-butane) \/ Rs(1,000 ppm): 0.45\u20130.62\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201325 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(3,000 ppm iso-butane) \/ Rs(1,000 ppm): 0.45\u20130.62\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2610-C00 is a Figaro Metal Oxide Semiconductor (MOS) sensor for LP Gas (Butane \/ Propane) measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2610-C00 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6db2\u5316\u77f3\u6cb9\u6c14\uff08\u4e01\u70f7 \/ \u4e19\u70f7\uff09\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2610-c00-a6a678f4162b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2610-c00-40f88c0ec58a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2610-d00\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2610-D00\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"LPG\",\"gasName\":{\"en\":\"LP Gas (Butane \/ Propane)\",\"zh\":\"\u6db2\u5316\u77f3\u6cb9\u6c14\uff08\u4e01\u70f7 \/ \u4e19\u70f7\uff09\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201325 %LEL\",\"sensitivity\":\"Rs(3,000 ppm iso-butane) \/ Rs(1,000 ppm): 0.37\u20130.60\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201325 %LEL\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(3,000 ppm iso-butane) \/ Rs(1,000 ppm): 0.37\u20130.60\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2610-D00 is a Figaro Metal Oxide Semiconductor (MOS) sensor for LP Gas (Butane \/ Propane) measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2610-D00 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6db2\u5316\u77f3\u6cb9\u6c14\uff08\u4e01\u70f7 \/ \u4e19\u70f7\uff09\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2610-d00-1a10bdfa8313.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2610-d00-f5945c5de35d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs44-100\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS44-100\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm NH\u2083\",\"sensitivity\":\"100 \u00b1 30 nA\/ppm\",\"responseTime\":\"60 s typical (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm NH\u2083\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"100 \u00b1 30 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"60 s typical (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"FECS44-100 is a Figaro Electrochemical sensor for Ammonia measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS44-100 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs44-100-5b5cf005d756.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs44-100-ce06aa590843.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs44-1000\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS44-1000\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131,000 ppm NH\u2083\",\"sensitivity\":\"8 \u00b1 4 nA\/ppm\",\"responseTime\":\"120 s typical (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"10 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131,000 ppm NH\u2083\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"8 \u00b1 4 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"120 s typical (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"10 ppm\"}],\"description\":{\"en\":\"FECS44-1000 is a Figaro Electrochemical sensor for Ammonia measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS44-1000 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs44-1000-3e0c35d04181.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs44-1000-7a8fe205a85e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs44-200\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS44-200\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm NH\u2083\",\"sensitivity\":\"40 \u00b1 12 nA\/ppm\",\"responseTime\":\"90 s typical (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"2 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm NH\u2083\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 \u00b1 12 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"90 s typical (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"2 ppm\"}],\"description\":{\"en\":\"FECS44-200 is a Figaro Electrochemical sensor for Ammonia measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS44-200 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs44-200-61779d212174.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs44-100-ce06aa590843.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs44-5000\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS44-5000\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135,000 ppm NH\u2083\",\"sensitivity\":\"4 \u00b1 2 nA\/ppm\",\"responseTime\":\"150 s typical (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"20 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135,000 ppm NH\u2083\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"4 \u00b1 2 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"150 s typical (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"20 ppm\"}],\"description\":{\"en\":\"FECS44-5000 is a Figaro Electrochemical sensor for Ammonia measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS44-5000 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs44-5000-7db854ffc79b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs44-1000-7a8fe205a85e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs41-250\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS41-250\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013250 ppm NO\",\"sensitivity\":\"400 \u00b1 80 nA\/ppm\",\"responseTime\":\"<40 s typical (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013250 ppm NO\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"400 \u00b1 80 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<40 s typical (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.5 ppm\"}],\"description\":{\"en\":\"FECS41-250 is a Figaro Electrochemical sensor for Nitric Oxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS41-250 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u6c2e\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs41-250-a21e2a4188dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs41-250-0dbb8819e111.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs42-20\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS42-20\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm NO\u2082\",\"sensitivity\":\"\u2212600 \u00b1 150 nA\/ppm\",\"responseTime\":\"<25 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm NO\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"\u2212600 \u00b1 150 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<25 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"FECS42-20 is a Figaro Electrochemical sensor for Nitrogen Dioxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS42-20 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs42-20-2111a33a9953.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs42-20-dc46d41d7bd5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:ke-12f3lf\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"KE-12F3LF\",\"seriesKey\":\"figaro:ke-lf\",\"series\":{\"en\":\"KE-LF Oxygen Series\",\"zh\":\"KE-LF \u6c27\u6c14\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 % O\u2082\",\"sensitivity\":\"Initial output: 9.0\u201315.0 mV\",\"responseTime\":\"Approx. 8 s (90%)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Accuracy: \u00b11 % full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 % O\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Initial output: 9.0\u201315.0 mV\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Approx. 8 s (90%)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Accuracy: \u00b11 % full scale\"}],\"description\":{\"en\":\"KE-12F3LF is a Figaro Electrochemical sensor for Oxygen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"KE-12F3LF \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-ke-12f3lf-e3ac22d8280b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-ke-12f3lf-761f92ebdb49.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:ke-25f3lf\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"KE-25F3LF\",\"seriesKey\":\"figaro:ke-lf\",\"series\":{\"en\":\"KE-LF Oxygen Series\",\"zh\":\"KE-LF \u6c27\u6c14\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 % O\u2082\",\"sensitivity\":\"Initial output: 10.0\u201315.5 mV\",\"responseTime\":\"Approx. 15 s (90%)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Accuracy: \u00b11 % full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 % O\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Initial output: 10.0\u201315.5 mV\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Approx. 15 s (90%)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Accuracy: \u00b11 % full scale\"}],\"description\":{\"en\":\"KE-25F3LF is a Figaro Electrochemical sensor for Oxygen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"KE-25F3LF \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-ke-25f3lf-58b96e3c1320.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-ke-12f3lf-761f92ebdb49.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:ke-25f3lfm\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"KE-25F3LFM\",\"seriesKey\":\"figaro:ke-lf\",\"series\":{\"en\":\"KE-LF Oxygen Series\",\"zh\":\"KE-LF \u6c27\u6c14\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 % O\u2082\",\"sensitivity\":\"Initial output: 5.0\u20138.0 mV\",\"responseTime\":\"Approx. 15 s (90%)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Accuracy: \u00b11 % full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 % O\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Initial output: 5.0\u20138.0 mV\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Approx. 15 s (90%)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Accuracy: \u00b11 % full scale\"}],\"description\":{\"en\":\"KE-25F3LFM is a Figaro Electrochemical sensor for Oxygen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"KE-25F3LFM \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-ke-25f3lfm-b1829f5a43ce.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-ke-12f3lf-761f92ebdb49.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:ke-25lf\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"KE-25LF\",\"seriesKey\":\"figaro:ke-lf\",\"series\":{\"en\":\"KE-LF Oxygen Series\",\"zh\":\"KE-LF \u6c27\u6c14\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 % O\u2082\",\"sensitivity\":\"Initial output: 10.0\u201315.5 mV\",\"responseTime\":\"Approx. 15 s (90%)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Accuracy: \u00b11 % full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 % O\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Initial output: 10.0\u201315.5 mV\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Approx. 15 s (90%)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Accuracy: \u00b11 % full scale\"}],\"description\":{\"en\":\"KE-25LF is a Figaro Electrochemical sensor for Oxygen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"KE-25LF \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-ke-25lf-47274c1615ff.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-ke-12f3lf-761f92ebdb49.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:ke-50lf\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"KE-50LF\",\"seriesKey\":\"figaro:ke-lf\",\"series\":{\"en\":\"KE-LF Oxygen Series\",\"zh\":\"KE-LF \u6c27\u6c14\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 % O\u2082\",\"sensitivity\":\"Initial output: 4.5\u20137.5 mV\",\"responseTime\":\"Approx. 60 s (90%)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Accuracy: \u00b12 % full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 % O\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Initial output: 4.5\u20137.5 mV\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Approx. 60 s (90%)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Accuracy: \u00b12 % full scale\"}],\"description\":{\"en\":\"KE-50LF is a Figaro Electrochemical sensor for Oxygen measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"KE-50LF \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-ke-50lf-9beb8d814b76.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-ke-12f3lf-761f92ebdb49.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fcm2630-c01\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FCM2630-C01\",\"seriesKey\":\"figaro:fcm\",\"series\":{\"en\":\"FCM Refrigerant Gas Module\",\"zh\":\"FCM \u5236\u51b7\u5242\u6c14\u4f53\u6a21\u7ec4\"},\"gas\":\"R32\",\"gasName\":{\"en\":\"R-32 Refrigerant\",\"zh\":\"R-32 \u5236\u51b7\u5242\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"Declared alarm set point: 5,000 ppm R-32\",\"sensitivity\":\"VOUT: 3.50 V typical @ 5,000 ppm R-32\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Initial alarm accuracy: 2,800\u20137,000 ppm R-32\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Declared alarm set point: 5,000 ppm R-32\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"VOUT: 3.50 V typical @ 5,000 ppm R-32\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Initial alarm accuracy: 2,800\u20137,000 ppm R-32\"}],\"description\":{\"en\":\"FCM2630-C01 is a Figaro Metal Oxide Semiconductor (MOS) sensor for R-32 Refrigerant measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FCM2630-C01 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8eR-32 \u5236\u51b7\u5242\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fcm2630-c01-d8368ed8f9e2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fcm2630-c01-7abf35e4ee01.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fcm2630-j0a\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FCM2630-J0A\",\"seriesKey\":\"figaro:fcm\",\"series\":{\"en\":\"FCM Refrigerant Gas Module\",\"zh\":\"FCM \u5236\u51b7\u5242\u6c14\u4f53\u6a21\u7ec4\"},\"gas\":\"R32\",\"gasName\":{\"en\":\"R-32 Refrigerant\",\"zh\":\"R-32 \u5236\u51b7\u5242\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"Alarm set point: 6,000 ppm R-32\",\"sensitivity\":\"NPN open-collector outputs\",\"responseTime\":\"\u226430 s @ 36,000 ppm R-32\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Initial alarm accuracy: 4,000\u20136,000 ppm R-32\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Alarm set point: 6,000 ppm R-32\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"NPN open-collector outputs\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430 s @ 36,000 ppm R-32\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Initial alarm accuracy: 4,000\u20136,000 ppm R-32\"}],\"description\":{\"en\":\"FCM2630-J0A is a Figaro Metal Oxide Semiconductor (MOS) sensor for R-32 Refrigerant measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FCM2630-J0A \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8eR-32 \u5236\u51b7\u5242\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fcm2630-j0a-363dca23063a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fcm2630-j0a-12ed8f5deb8b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2630\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2630\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"REFRIGERANT\",\"gasName\":{\"en\":\"Refrigerant Gas\",\"zh\":\"\u5236\u51b7\u5242\u6c14\u4f53\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1,000\u201310,000 ppm R-32\",\"sensitivity\":\"Rs(9,000 ppm R-32) \/ Rs(3,000 ppm): 0.2\u20130.7\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1,000\u201310,000 ppm R-32\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(9,000 ppm R-32) \/ Rs(3,000 ppm): 0.2\u20130.7\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2630 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Refrigerant Gas measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2630 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5236\u51b7\u5242\u6c14\u4f53\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2630-981d70e00c10.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2630-ac3334709498.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs3830\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS3830\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"REFRIGERANT\",\"gasName\":{\"en\":\"Refrigerant Gas\",\"zh\":\"\u5236\u51b7\u5242\u6c14\u4f53\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"5\u2013100 ppm\",\"sensitivity\":\"Rs(10 ppm R-134a) \/ Rs(air): \u22640.85\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"5\u2013100 ppm\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(10 ppm R-134a) \/ Rs(air): \u22640.85\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS3830 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Refrigerant Gas measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS3830 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5236\u51b7\u5242\u6c14\u4f53\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs3830-5c3851f77fe1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs3830-df1a78bd1f3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:fecs43-20\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"FECS43-20\",\"seriesKey\":\"figaro:fecs\",\"series\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm SO\u2082\",\"sensitivity\":\"500 \u00b1 100 nA\/ppm\",\"responseTime\":\"<25 s (T90)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm SO\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"500 \u00b1 100 nA\/ppm\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<25 s (T90)\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"FECS43-20 is a Figaro Electrochemical sensor for Sulfur Dioxide measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"FECS43-20 \u662f Figaro \u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-fecs43-20-d0e76d42becc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-fecs43-20-05c9efb6164f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2600\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2600\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201330 ppm H\u2082\",\"sensitivity\":\"Rs(10 ppm H\u2082) \/ Rs(air): 0.3\u20130.6\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201330 ppm H\u2082\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(10 ppm H\u2082) \/ Rs(air): 0.3\u20130.6\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2600 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Air Contaminants \/ VOCs measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2600 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7a7a\u6c14\u6c61\u67d3\u7269 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2600-c607074505dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2600-5eff2ee2f30e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2602\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2602\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201330 ppm EtOH\",\"sensitivity\":\"Rs(10 ppm EtOH) \/ Rs(air): 0.08\u20130.5\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201330 ppm EtOH\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(10 ppm EtOH) \/ Rs(air): 0.08\u20130.5\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2602 is a Figaro Metal Oxide Semiconductor (MOS) sensor for VOCs \/ Odor measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2602 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6325\u53d1\u6027\u6709\u673a\u7269 \/ \u5f02\u5473\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2602-91bd735262f0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2602-48db20d650ba.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2603\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2603\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"1\u201310 ppm EtOH\",\"sensitivity\":\"Rs(10 ppm EtOH) \/ Rs(air): <0.5\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"1\u201310 ppm EtOH\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(10 ppm EtOH) \/ Rs(air): <0.5\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2603 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Odor \/ Air Contaminants measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2603 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5f02\u5473 \/ \u7a7a\u6c14\u6c61\u67d3\u7269\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2603-4a2b87c06ae7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2603-9adaa73ba50f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"figaro:tgs2620\",\"brandKey\":\"figaro\",\"brandName\":\"Figaro\",\"model\":\"TGS2620\",\"seriesKey\":\"figaro:tgs-mos\",\"series\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"},\"specs\":{\"range\":\"50\u20135,000 ppm EtOH\",\"sensitivity\":\"Rs(300 ppm EtOH) \/ Rs(50 ppm): 0.3\u20130.5\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"50\u20135,000 ppm EtOH\"},{\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"Rs(300 ppm EtOH) \/ Rs(50 ppm): 0.3\u20130.5\"},{\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\"},{\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u2014\"}],\"description\":{\"en\":\"TGS2620 is a Figaro Metal Oxide Semiconductor (MOS) sensor for Alcohol \/ Solvent Vapor measurement. Key values shown here are transcribed from the official Product Information PDF; use the datasheet for test conditions and integration details.\",\"zh\":\"TGS2620 \u662f Figaro \u7684\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u9187\u7c7b \/ \u6eb6\u5242\u84b8\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u5173\u952e\u53c2\u6570\u5747\u6309\u539f\u5382 Product Information PDF \u6574\u7406\uff1b\u6d4b\u8bd5\u6761\u4ef6\u4e0e\u96c6\u6210\u7ec6\u8282\u8bf7\u4ee5\u89c4\u683c\u4e66\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/images\/figaro-tgs2620-86fa504a0ff8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/figaro\/documents\/figaro-tgs2620-f5ed7d488d3a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:dgm10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"DGM10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:dgm10\",\"series\":{\"en\":\"DGM10 Dual-Gas Modules\",\"zh\":\"DGM10 \u53cc\u6c14\u4f53\u6a21\u5757\"},\"gas\":\"DUAL_GAS\",\"gasName\":{\"en\":\"Dual Gas\",\"zh\":\"\u53cc\u6c14\u4f53\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"Configuration-dependent; see product list\",\"sensitivity\":\"UART (Modbus-RTU) \/ I\u00b2C; optional SPI\",\"signal\":\"UART (Modbus-RTU) \/ I\u00b2C; optional SPI\",\"responseTime\":\"Sensor-dependent; see product list\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Sensor-dependent; see product list\",\"temperature\":\"-40 to +55\u00b0C\",\"humidity\":\"15 to 95% RH. Non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Configuration-dependent; see product list\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART (Modbus-RTU) \/ I\u00b2C; optional SPI\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Sensor-dependent; see product list\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Sensor-dependent; see product list\"}],\"description\":{\"en\":\"DGM10 is an EC Sense DGM10 Dual-Gas Modules module for Dual Gas. Its main output\/interface is UART (Modbus-RTU) \/ I\u00b2C; optional SPI; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"DGM10 \u662f EC Sense DGM10 \u53cc\u6c14\u4f53\u6a21\u5757\uff0c\u7528\u4e8e\u53cc\u6c14\u4f53\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART (Modbus-RTU) \/ I\u00b2C; optional SPI\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-bild2-5665aaff555a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-dgm10-double-sensor-module-datasheet-v2-3-20250408-375ecfe584be.pdf\",\"match\":\"reference\"},{\"kind\":\"product-list\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-dgm10-product-list-v1-0-20250408-fc95e6bef4b7.pdf\",\"match\":\"reference\"},{\"kind\":\"protocol\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-dgm10-double-gas-sensor-module-communication-protocol-v1-1-20230915-ee95c4f448ac.pdf\",\"match\":\"exact\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:ds4\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"DS4\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:ds4\",\"series\":{\"en\":\"DS4 Digital Sensor Modules\",\"zh\":\"DS4 \u6570\u5b57\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"MULTI_GAS\",\"gasName\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"},\"supportedGases\":[\"ASH3\",\"ETO\",\"PH3\",\"VOC\",\"SO2\",\"SMELL\",\"O3\",\"O2\",\"NO2\",\"NH3\",\"H2S\",\"HCN\",\"CH2O\",\"H2\",\"CO\",\"CL2\",\"CH3SH\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"Configuration-dependent; see datasheet\",\"sensitivity\":\"UART 3.3 V half-duplex\",\"signal\":\"UART 3.3 V half-duplex\",\"responseTime\":\"Sensor-dependent; see datasheet\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Sensor-dependent; see datasheet\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15 to 95% RH. non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Configuration-dependent; see datasheet\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART 3.3 V half-duplex\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Sensor-dependent; see datasheet\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"Sensor-dependent; see datasheet\"}],\"description\":{\"en\":\"DS4 is an EC Sense DS4 Digital Sensor Modules module for Multiple Gases. Its main output\/interface is UART 3.3 V half-duplex; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"DS4 \u662f EC Sense DS4 \u6570\u5b57\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u591a\u6c14\u4f53\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART 3.3 V half-duplex\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ds4-website-product-image-b160021f8579.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ds4-smart-digital-gas-sensor-datasheet-v1-3-20250523-c970c8913a3e.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-br2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-Br2-5\",\"partNumber\":\"01-EC4-Br2-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"BR2\",\"gasName\":{\"en\":\"Bromine\",\"zh\":\"\u6eb4\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\",\"signal\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +40 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"EC4-Br2-5 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Bromine, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-Br2-5 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6eb4\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-br2-5-1-31ae03eba24a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-br2-5-01-bromine-gas-sensor-datasheet-v1-2-20250221-a5ed03d23145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-cl2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-Cl2-5\",\"partNumber\":\"01-EC4-Cl2-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\",\"signal\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +40 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"EC4-Cl2-5 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Chlorine, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-Cl2-5 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-cl2-5-1-410fc3540f82.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-cl2-5-01-chlorine-gas-sensor-datasheet-v1-2-20250221-e0af84e9108c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-cl2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-Cl2-50\",\"partNumber\":\"01-EC4-Cl2-50-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\",\"signal\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to +40 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-600 nA\/ppm \u00b1 200 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.1 ppm\"}],\"description\":{\"en\":\"EC4-Cl2-50 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Chlorine, with a measurement range of 0\u201350 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-Cl2-50 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-cl2-50-1-eedaa245072b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-cl2-50-01-chlorine-gas-sensor-datasheet-v1-2-20250221-93208cb36542.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-clo2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-ClO2-5\",\"partNumber\":\"01-EC4-ClO2-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"-325 nA\/ppm \u00b1 200 nA\/ppm\",\"signal\":\"-325 nA\/ppm \u00b1 200 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +40 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-325 nA\/ppm \u00b1 200 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"EC4-ClO2-5 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Chlorine Dioxide, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-ClO2-5 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-clo2-5-1-fc26e70affbd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-clo2-5-01-chlorine-dioxide-gas-sensor-datasheet-v1-2-20250221-380a04369fce.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-f2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-F2-5\",\"partNumber\":\"01-EC4-F2-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"F2\",\"gasName\":{\"en\":\"Fluorine\",\"zh\":\"\u6c1f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"-260 nA\/ppm \u00b1 80 nA\/ppm\",\"signal\":\"-260 nA\/ppm \u00b1 80 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +40 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-260 nA\/ppm \u00b1 80 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"EC4-F2-5 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Fluorine, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-F2-5 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c1f\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-f2-5-1-0307de8d5e1e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-f2-5-01-fluorine-gas-sensor-datasheet-v1-2-20250221-e5639761406d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-hcl-30\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-HCl-30\",\"partNumber\":\"01-EC4-HCl-30-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330 ppm\",\"sensitivity\":\"-150 nA\/ppm \u00b1 50 nA\/ppm\",\"signal\":\"-150 nA\/ppm \u00b1 50 nA\/ppm\",\"responseTime\":\"T50 < 40 s, T90 < 80 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-150 nA\/ppm \u00b1 50 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 40 s, T90 < 80 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.1 ppm\"}],\"description\":{\"en\":\"EC4-HCl-30 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Hydrogen Chloride, with a measurement range of 0\u201330 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-HCl-30 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c2f\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201330 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-hcl-30-1-af04a607a47c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-hcl-30-01-hydrogen-chloride-gas-sensor-datasheet-v1-3-20250221-c1e3fbeb4ffc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-hf-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-HF-10\",\"partNumber\":\"01-EC4-HF-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"-350 nA\/ppm \u00b1 250 nA\/ppm\",\"signal\":\"-350 nA\/ppm \u00b1 250 nA\/ppm\",\"responseTime\":\"T50 < 40 s, T90 < 80 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.1 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-350 nA\/ppm \u00b1 250 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 40 s, T90 < 80 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.1 ppm\"}],\"description\":{\"en\":\"EC4-HF-10 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Hydrogen Fluoride, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-HF-10 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c1f\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-hf-10-1-e71153defc31.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-hf-10-01-hydrogen-fluoride-gas-sensor-datasheet-v1-3-20250409-ba4f9d5ef397.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-nh3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-NH3-100\",\"partNumber\":\"01-EC4-NH3-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"115 nA\/ppm \u00b1 35 nA\/ppm\",\"signal\":\"115 nA\/ppm \u00b1 35 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 50 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-30 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"115 nA\/ppm \u00b1 35 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 50 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"EC4-NH3-100 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Ammonia, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-NH3-100 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-nh3-100-1-e5937b303d87.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-nh3-100-01-ammonia-gas-sensor-datasheet-v1-3-20260120-9999640229d7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-nh3-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-NH3-1000\",\"partNumber\":\"01-EC4-NH3-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"15 nA\/ppm \u00b1 5 nA\/ppm\",\"signal\":\"15 nA\/ppm \u00b1 5 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 50 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-30 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"15 nA\/ppm \u00b1 5 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 50 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"EC4-NH3-1000 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Ammonia, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-NH3-1000 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-nh3-100-1-e5937b303d87.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-nh3-1000-01-ammonia-gas-sensor-datasheet-v1-3-20260120-92d8741936b7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ec4-nh3-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"EC4-NH3-500\",\"partNumber\":\"01-EC4-NH3-500-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:ec4\",\"series\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Three-Electrode Electrochemical\",\"zh\":\"\u4e09\u7535\u6781\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 50 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-30 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"35 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 50 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"EC4-NH3-500 is an EC Sense EC4 Liquid-Electrolyte Series sensor for Ammonia, with a measurement range of 0\u2013500 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"EC4-NH3-500 \u662f EC Sense EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013500 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ec4-nh3-500-1-e5937b303d87.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ec4-nh3-500-01-ammonia-gas-sensor-datasheet-v1-3-20260120-f5916b79d4ef.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ecgaspoint-iaq\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ECgaspoint IAQ\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:ecgaspoint\",\"series\":{\"en\":\"ECgaspoint Wireless Devices\",\"zh\":\"ECgaspoint \u65e0\u7ebf\u68c0\u6d4b\u8bbe\u5907\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Indoor Air Quality\",\"zh\":\"\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u201310,000 ppb\",\"sensitivity\":\"Wi-Fi 2.4 GHz + MQTT\",\"signal\":\"Wi-Fi 2.4 GHz + MQTT\",\"responseTime\":\"5 s\",\"responseLabel\":{\"en\":\"Data Update\",\"zh\":\"\u6570\u636e\u5237\u65b0\"},\"resolution\":\"1 ppb\",\"temperature\":\"0\u00b0C to +50\u00b0C\",\"humidity\":\"15 to 95% RH (non-condensing)\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310,000 ppb\"},{\"key\":\"output\",\"label\":{\"en\":\"Communication\",\"zh\":\"\u901a\u4fe1\"},\"value\":\"Wi-Fi 2.4 GHz + MQTT\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Data Update\",\"zh\":\"\u6570\u636e\u5237\u65b0\"},\"value\":\"5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"1 ppb\"}],\"description\":{\"en\":\"ECgaspoint IAQ is an EC Sense ECgaspoint Wireless Devices sensing device for Indoor Air Quality. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"ECgaspoint IAQ \u662f EC Sense ECgaspoint \u65e0\u7ebf\u68c0\u6d4b\u8bbe\u5907\uff0c\u7528\u4e8e\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ecgaspoint-3-white-background-26fca8a97916.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ecgaspoint-iaq-datasheet-v1-0-202111102-d4c5aedff625.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ecgaspoint-ozone\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ECgaspoint Ozone\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:ecgaspoint\",\"series\":{\"en\":\"ECgaspoint Wireless Devices\",\"zh\":\"ECgaspoint \u65e0\u7ebf\u68c0\u6d4b\u8bbe\u5907\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u20135000 ppb \/ 0\u2013100 ppm\",\"sensitivity\":\"Wi-Fi 2.4 GHz + MQTT\",\"signal\":\"Wi-Fi 2.4 GHz + MQTT\",\"responseTime\":\"5 s\",\"responseLabel\":{\"en\":\"Data Update\",\"zh\":\"\u6570\u636e\u5237\u65b0\"},\"resolution\":\"10 ppb \/ 0.1 ppm\",\"temperature\":\"0\u00b0C to +50\u00b0C\",\"humidity\":\"15\u201395% RH (non-condensing)\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135000 ppb \/ 0\u2013100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Communication\",\"zh\":\"\u901a\u4fe1\"},\"value\":\"Wi-Fi 2.4 GHz + MQTT\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Data Update\",\"zh\":\"\u6570\u636e\u5237\u65b0\"},\"value\":\"5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"10 ppb \/ 0.1 ppm\"}],\"description\":{\"en\":\"ECgaspoint Ozone is an EC Sense ECgaspoint Wireless Devices sensing device for Ozone. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"ECgaspoint Ozone \u662f EC Sense ECgaspoint \u65e0\u7ebf\u68c0\u6d4b\u8bbe\u5907\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ecgaspoint-3-white-background-26fca8a97916.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ecgaspoint-ozone-datasheet-v1-0-202111112-68c4c9a56282.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ecgaspoint\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ECgaspoint\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:ecgaspoint\",\"series\":{\"en\":\"ECgaspoint Wireless Devices\",\"zh\":\"ECgaspoint \u65e0\u7ebf\u68c0\u6d4b\u8bbe\u5907\"},\"gas\":\"MULTI_GAS\",\"gasName\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"},\"supportedGases\":[\"O2\",\"NH3\",\"CH2O\",\"CO\",\"VOC\",\"SO2\",\"NO2\",\"SMELL\",\"H2S\",\"PH3\",\"ETO\",\"H2\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u20132 to 0\u20132000 ppm; O\u2082 0\u201325% vol.\",\"sensitivity\":\"Wi-Fi 2.4 GHz + MQTT\",\"signal\":\"Wi-Fi 2.4 GHz + MQTT\",\"responseTime\":\"5 s\",\"responseLabel\":{\"en\":\"Data Update\",\"zh\":\"\u6570\u636e\u5237\u65b0\"},\"resolution\":\"0.01\u20131 ppm; O\u2082 0.01% vol.\",\"temperature\":\"0\u00b0C to +50\u00b0C\",\"humidity\":\"15 to 95% RH (non-condensing)\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132 to 0\u20132000 ppm; O\u2082 0\u201325% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Communication\",\"zh\":\"\u901a\u4fe1\"},\"value\":\"Wi-Fi 2.4 GHz + MQTT\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Data Update\",\"zh\":\"\u6570\u636e\u5237\u65b0\"},\"value\":\"5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01\u20131 ppm; O\u2082 0.01% vol.\"}],\"description\":{\"en\":\"ECgaspoint is an EC Sense ECgaspoint Wireless Devices sensing device for Multiple Gases. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"ECgaspoint \u662f EC Sense ECgaspoint \u65e0\u7ebf\u68c0\u6d4b\u8bbe\u5907\uff0c\u7528\u4e8e\u591a\u6c14\u4f53\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ecgaspoint-3-white-background-26fca8a97916.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ecgaspoint-general-datasheet-v1-0-202111171-54ffdcede098.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:ecnose-iaq-200-b\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ECnose-IAQ-200-B\",\"partNumber\":\"05-ECnose-IAQ-200-B-01\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:ecnose\",\"series\":{\"en\":\"ECnose Portable IAQ Devices\",\"zh\":\"ECnose \u4fbf\u643a\u5f0f\u7a7a\u6c14\u8d28\u91cf\u8bbe\u5907\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Indoor Air Quality\",\"zh\":\"\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"7 LEDs + audible alarm\",\"signal\":\"7 LEDs + audible alarm\",\"responseTime\":\"Initial <3 s; T90 <80 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"0\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Indication\",\"zh\":\"\u6307\u793a\u65b9\u5f0f\"},\"value\":\"7 LEDs + audible alarm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Initial <3 s; T90 <80 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"ECnose-IAQ-200-B is an EC Sense ECnose Portable IAQ Devices sensing device for Indoor Air Quality. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"ECnose-IAQ-200-B \u662f EC Sense ECnose \u4fbf\u643a\u5f0f\u7a7a\u6c14\u8d28\u91cf\u8bbe\u5907\uff0c\u7528\u4e8e\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ecnose-b-1-white-background-without-shadow-f0c0062a56c4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ecnose-air-quality-gas-monitor-datasheet-v0-0-202012171-3d6109a21f82.pdf\",\"match\":\"exact\"}],\"variantGroup\":\"ecsense-ecnose-iaq-200\",\"variantColor\":{\"en\":\"Black\",\"zh\":\"\u9ed1\u8272\"},\"embeddedDetails\":true},{\"id\":\"ecsense:ecnose-iaq-200-w\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ECnose-IAQ-200-W\",\"partNumber\":\"05-ECnose-IAQ-200-W-01\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:ecnose\",\"series\":{\"en\":\"ECnose Portable IAQ Devices\",\"zh\":\"ECnose \u4fbf\u643a\u5f0f\u7a7a\u6c14\u8d28\u91cf\u8bbe\u5907\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Indoor Air Quality\",\"zh\":\"\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"7 LEDs + audible alarm\",\"signal\":\"7 LEDs + audible alarm\",\"responseTime\":\"Initial <3 s; T90 <80 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"0\u201350 \u00b0C\",\"humidity\":\"\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Indication\",\"zh\":\"\u6307\u793a\u65b9\u5f0f\"},\"value\":\"7 LEDs + audible alarm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Initial <3 s; T90 <80 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"ECnose-IAQ-200-W is an EC Sense ECnose Portable IAQ Devices sensing device for Indoor Air Quality. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"ECnose-IAQ-200-W \u662f EC Sense ECnose \u4fbf\u643a\u5f0f\u7a7a\u6c14\u8d28\u91cf\u8bbe\u5907\uff0c\u7528\u4e8e\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ecnose-w-1-bigger-white-background-e1626946617549-70d764f30a15.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ecnose-air-quality-gas-monitor-datasheet-v0-0-202012171-3d6109a21f82.pdf\",\"match\":\"exact\"}],\"variantGroup\":\"ecsense-ecnose-iaq-200\",\"variantColor\":{\"en\":\"White\",\"zh\":\"\u767d\u8272\"},\"embeddedDetails\":true},{\"id\":\"ecsense:ectox-nh3-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ECtox-NH3-500\",\"partNumber\":\"05-ECtox-NH3-500-01 \/ 05-ECtox-HT-NH3-500-01\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:ectox\",\"series\":{\"en\":\"ECtox Ammonia Devices\",\"zh\":\"ECtox \u6c28\u6c14\u68c0\u6d4b\u8bbe\u5907\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"RS485 Modbus, 9600 baud\",\"signal\":\"RS485 Modbus, 9600 baud\",\"responseTime\":\"1\u201310 min (selected measurement period)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm; detection limit 1 ppm\",\"temperature\":\"\u221220\u201355 \u00b0C\",\"humidity\":\"10 \u2013 95%\",\"lifetime\":\"\u22652 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"RS485 Modbus, 9600 baud\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"1\u201310 min (selected measurement period)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm; detection limit 1 ppm\"}],\"description\":{\"en\":\"ECtox-NH3-500 is an EC Sense ECtox Ammonia Devices sensing device for Ammonia. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"ECtox-NH3-500 \u662f EC Sense ECtox \u6c28\u6c14\u68c0\u6d4b\u8bbe\u5907\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ectox-nh3-500-1-smaller-white-background-def1dad3e331.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ectox-ammonia-sensor-device-datasheet-v1-4-20251209-4e80e94459be.pdf\",\"match\":\"exact\"},{\"kind\":\"application-note\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-ectox-advantages-for-farming-applications-v1-0-20230802-208c127c32b4.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ag1-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-AG1-10\",\"partNumber\":\"01-ES1-AG1-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES1-AG1-10 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for All Gas \/ VOC, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES1-AG1-10 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ag1-10-01-2438a1c2df2f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ag1-10-01-all-gas-sensor-datasheet-v1-4-20250306-2aa7411f1f6a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ag1-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-AG1-1000\",\"partNumber\":\"01-ES1-AG1-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"35 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-AG1-1000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for All Gas \/ VOC, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES1-AG1-1000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ag1-1000-01-441d42dcfa76.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ag1-1000-01-all-gas-sensor-datasheet-v1-4-20250306-1dc1a2ba3ac7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ag1-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-AG1-200\",\"partNumber\":\"01-ES1-AG1-200-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-AG1-200 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for All Gas \/ VOC, with a measurement range of 0\u2013200 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES1-AG1-200 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013200 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ag1-200-01-0dccca3a4491.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ag1-200-01-all-gas-sensor-datasheet-v1-4-20250306-681c334f14d9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ag1-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-AG1-2000\",\"partNumber\":\"01-ES1-AG1-2000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"11 nA\/ppm \u00b1 4 nA\/ppm\",\"signal\":\"11 nA\/ppm \u00b1 4 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"11 nA\/ppm \u00b1 4 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-AG1-2000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for All Gas \/ VOC, with a measurement range of 0\u20132000 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES1-AG1-2000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20132000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ag1-2000-01-56c279229a87.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ag1-2000-01-all-gas-sensor-datasheet-v1-4-20250306-d68cb0f651e9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ash3-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-AsH3-1\",\"partNumber\":\"01-ES1-AsH3-1-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"signal\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"120 nA\/ppm \u00b1 40 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.02 ppm\"}],\"description\":{\"en\":\"ES1-AsH3-1 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Arsine, with a measurement range of 0\u20131 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-AsH3-1 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7837\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ash3-1-5-9a17a2e2f7cb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ash3-1-01-arsine-gas-sensor-datasheet-v1-2-20250228-7d9b216103d7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ch4s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-CH4S-10\",\"partNumber\":\"01-ES1-CH4S-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"60 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"60 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"60 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES1-CH4S-10 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Methanethiol \/ Methyl Mercaptan, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"ES1-CH4S-10 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ch4s-10-1-ecbe96084406.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ch4s-10-01-methyl-mercaptan-gas-sensor-datasheet-v1-5-20250403-39350a1289eb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ch4s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-CH4S-100\",\"partNumber\":\"01-ES1-CH4S-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-CH4S-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Methanethiol \/ Methyl Mercaptan, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"ES1-CH4S-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ch4s-100-1-ecb4eda1de06.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ch4s-100-01-methyl-mercaptan-gas-sensor-datasheet-v1-5-20250403-7c97c7f52293.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-co-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-CO-10\",\"partNumber\":\"01-ES1-CO-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"35 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES1-CO-10 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Carbon Monoxide, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-CO-10 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-co-10-1-9bdda7337dfe.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-co-10-01-carbon-monoxide-gas-sensor-datasheet-v1-4-20250228-c6c0409b506f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-co-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-CO-100\",\"partNumber\":\"01-ES1-CO-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"30 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"30 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"30 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-CO-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Carbon Monoxide, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-CO-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-co-100-01-1-d28c261a89bf.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-co-100-01-carbon-monoxide-gas-sensor-datasheet-v1-4-20250228-774cf162576f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-co-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-CO-1000\",\"partNumber\":\"01-ES1-CO-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"25 nA\/ppm +15 nA\/ppm -10 nA\/ppm\",\"signal\":\"25 nA\/ppm +15 nA\/ppm -10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"25 nA\/ppm +15 nA\/ppm -10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-CO-1000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Carbon Monoxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-CO-1000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-co-1000-01-7e0172fc854a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-co-1000-01-carbon-monoxide-gas-sensor-datasheet-v1-4-20250228-cad5fb3b5d12.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-eto-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-ETO-10\",\"partNumber\":\"01-ES1-ETO-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES1-ETO-10 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Ethylene Oxide, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"ES1-ETO-10 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-eto-10-1-7a865713d76c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-eto-10-01-ethylene-oxide-gas-sensor-datasheet-v1-2-20250228-67fc184ada7f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-eto-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-ETO-1000\",\"partNumber\":\"01-ES1-ETO-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-ETO-1000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Ethylene Oxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"ES1-ETO-1000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-eto-1000-1-a5cd3669c4fe.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-eto-1000-01-ethylene-oxide-gas-sensor-datasheet-v1-2-20250228-a62369b662f0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-eto-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-ETO-200\",\"partNumber\":\"01-ES1-ETO-200-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-ETO-200 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Ethylene Oxide, with a measurement range of 0\u2013200 ppm. Key values are taken from the latest official PDF. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"ES1-ETO-200 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013200 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-eto-200-1-ebdb527b3bc6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-eto-200-01-ethylene-oxide-gas-sensor-datasheet-v1-2-20250228-cf5344d70c14.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-h2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-H2-1000\",\"partNumber\":\"01-ES1-H2-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"9 nA\/ppm \u00b1 4 nA\/ppm\",\"signal\":\"9 nA\/ppm \u00b1 4 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"9 nA\/ppm \u00b1 4 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-H2-1000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-H2-1000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-h2-1000-01-32b44306632d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-h2-1000-01-hydrogen-gas-sensor-datasheet-v1-4-20250228-5bdcce3cfa96.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-h2-5-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-H2-5%\",\"partNumber\":\"01-ES1-H2-5%-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135% vol.\",\"sensitivity\":\"0.2 nA\/ppm \u00b1 0.1 nA\/ppm\",\"signal\":\"0.2 nA\/ppm \u00b1 0.1 nA\/ppm\",\"responseTime\":\"T50 < 35 s, T90 < 90 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135% vol.\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"0.2 nA\/ppm \u00b1 0.1 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 35 s, T90 < 90 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.001% vol.\"}],\"description\":{\"en\":\"ES1-H2-5% is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen, with a measurement range of 0\u20135% vol.. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-H2-5% \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135% vol.\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-h2-5-4-64ac93b73177.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-h2-5-01-hydrogen-gas-sensor-datasheet-v1-8-20250228-f09f7071510f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-h2-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-H2-5000\",\"partNumber\":\"01-ES1-H2-5000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5000 ppm\",\"sensitivity\":\"3 nA\/ppm \u00b1 2 nA\/ppm\",\"signal\":\"3 nA\/ppm \u00b1 2 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"3 nA\/ppm \u00b1 2 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"ES1-H2-5000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen, with a measurement range of 0-5000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-H2-5000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0-5000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-h2-5000-1-96c661d443b2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-h2-5000-01-hydrogen-gas-sensor-datasheet-v1-4-20250228-6bfc0592fc5f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-h2s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-H2S-10\",\"partNumber\":\"01-ES1-H2S-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"160 nA\/ppm \u00b1 40 nA\/ppm\",\"signal\":\"160 nA\/ppm \u00b1 40 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"160 nA\/ppm \u00b1 40 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES1-H2S-10 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen Sulfide, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-H2S-10 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-h2s-10-2-28c26ae7d97c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-h2s-10-01-hydrogen-sulfide-gas-sensor-datasheet-v1-5-20250416-e214ca95d49b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-h2s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-H2S-100\",\"partNumber\":\"01-ES1-H2S-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"signal\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"100 nA\/ppm \u00b1 30 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-H2S-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen Sulfide, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-H2S-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-h2s-100-01-2eede929646a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-h2s-100-01-hydrogen-sulfide-gas-sensor-datasheet-v1-5-20250416-b75338d8ddf7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-h2s-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-H2S-500\",\"partNumber\":\"01-ES1-H2S-500-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"signal\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"100 nA\/ppm \u00b1 30 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-H2S-500 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen Sulfide, with a measurement range of 0\u2013500 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-H2S-500 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013500 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-h2s-500-01-17ae19afc528.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-h2s-500-01-hydrogen-sulfide-gas-sensor-datasheet-v1-5-20250416-f6e2fd4b04d9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-h2s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-H2S-5000\",\"partNumber\":\"01-ES1-H2S-5000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135000 ppm\",\"sensitivity\":\"0.28 nA\/ppm \u00b1 0.05 nA\/ppm\",\"signal\":\"0.28 nA\/ppm \u00b1 0.05 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"0.28 nA\/ppm \u00b1 0.05 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-H2S-5000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen Sulfide, with a measurement range of 0\u20135000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-H2S-5000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-h2s-5000-01-7ba1a6762112.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-h2s-5000-01-hydrogen-sulfide-gas-sensor-datasheet-v1-5-20250416-31e380897131.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-hcho-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-HCHO-100\",\"partNumber\":\"01-ES1-HCHO-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"signal\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 \u00b0C to +50 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"150 nA\/ppm \u00b1 100 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-HCHO-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Formaldehyde, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-HCHO-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-hcho-100-1-a900b5681f8d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-hcho-100-01-formaldehyde-gas-sensor-datasheet-v1-4-20250228-2960710621db.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-hcho-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-HCHO-5\",\"partNumber\":\"01-ES1-HCHO-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"signal\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20 \u00b0C to +50 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"150 nA\/ppm \u00b1 100 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES1-HCHO-5 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Formaldehyde, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-HCHO-5 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-hcho-5-01-11032a947709.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-hcho-5-01-formaldehyde-gas-sensor-datasheet-v1-4-20250228-a5efba519089.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-hcn-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-HCN-5\",\"partNumber\":\"01-ES1-HCN-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 30 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +45 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 30 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-HCN-5 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen Cyanide, with a measurement range of 0-5 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-HCN-5 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0-5 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-hcn-5-4-31b015489f6a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-hcn-5-01-hydrogen-cyanide-sensor-datasheet-v1-0-20260325-78f41b95c0d8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-hcn-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-HCN-50\",\"partNumber\":\"01-ES1-HCN-50-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-50 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 30 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +45 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-50 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 30 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-HCN-50 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Hydrogen Cyanide, with a measurement range of 0-50 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-HCN-50 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0-50 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-hcn-50-3-5cb2acce4e2b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-hcn-50-01-hydrogen-cyanide-sensor-datasheet-v1-0-20260325-151ee2647dab.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-nh3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-NH3-100\",\"partNumber\":\"01-ES1-NH3-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T90 < 150 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 150 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-NH3-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Ammonia, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-NH3-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-nh3-100-2-25f0d9a5fd6b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-nh3-100-01-ammonia-gas-sensor-datasheet-v1-4-20250228-32f9bc9cc20f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-no2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-NO2-100\",\"partNumber\":\"01-ES1-NO2-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-NO2-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Nitrogen Dioxide, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-NO2-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-no2-100-01-19cee785cb76.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-no2-100-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-75b42e4395ec.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-no2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-NO2-1000\",\"partNumber\":\"01-ES1-NO2-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"signal\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-NO2-1000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Nitrogen Dioxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-NO2-1000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-no2-1000-01-dae08ff5767e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-no2-1000-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-a1110fce47c8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-no2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-NO2-2000\",\"partNumber\":\"01-ES1-NO2-2000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"signal\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-NO2-2000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Nitrogen Dioxide, with a measurement range of 0\u20132000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-NO2-2000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20132000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-no2-2000-1-9f0ae0225bcc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-no2-2000-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-7ae7b2db17da.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-no2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-NO2-5\",\"partNumber\":\"01-ES1-NO2-5-02\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"-45 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"-45 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.005 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-45 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.005 ppm\"}],\"description\":{\"en\":\"ES1-NO2-5 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Nitrogen Dioxide, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-NO2-5 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-no2-5-5-white-308ca73807e0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-no2-5-02-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-97ad81314a77.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-no2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-NO2-50\",\"partNumber\":\"01-ES1-NO2-50-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-NO2-50 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Nitrogen Dioxide, with a measurement range of 0\u201350 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-NO2-50 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-no2-50-01-f9111d3d2e3b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-no2-50-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-63866aa479c8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-o2-25-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-O2-25%\",\"partNumber\":\"01-ES1-O2-25-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"0.23 nA\/ppm \u00b1 0.04 nA\/ppm\",\"signal\":\"0.23 nA\/ppm \u00b1 0.04 nA\/ppm\",\"responseTime\":\"T50 < 5 s, T90 < 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"0.23 nA\/ppm \u00b1 0.04 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 5 s, T90 < 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01% vol.\"}],\"description\":{\"en\":\"ES1-O2-25% is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Oxygen, with a measurement range of 0\u201325% vol.. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-O2-25% \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201325% vol.\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-o2-25-01-e7aa76384f57.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-o2-25-01-oxygen-gas-sensor-datasheet-v1-4-20250228-90b0ebd3f4ee.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-o3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-O3-100\",\"partNumber\":\"01-ES1-O3-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"signal\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"responseTime\":\"T50 < 40 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 40 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"ES1-O3-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Ozone, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-O3-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-gimp-white-background-es1-o3-100-2-e064bea152ca.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-o3-100-01-ozone-gas-sensor-datasheet-v1-4-20250228-d94fd9ec3a38.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-o3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-O3-5\",\"partNumber\":\"01-ES1-O3-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"-20 \u00b0C to +55 \u00b0C\",\"sensitivity\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"signal\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"responseTime\":\"T50 < 40 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"-20 \u00b0C to +55 \u00b0C\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 40 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"ES1-O3-5 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Ozone, with a measurement range of -20 \u00b0C to +55 \u00b0C. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-O3-5 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a -20 \u00b0C to +55 \u00b0C\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-gimp-white-background-es1-o3-5-2-044338a2f687.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-o3-5-01-ozone-gas-sensor-datasheet-v1-4-20250228-beccd2d51a7b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-ph3-20\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-PH3-20\",\"partNumber\":\"01-ES1-PH3-20-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"signal\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-10 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"120 nA\/ppm \u00b1 40 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES1-PH3-20 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Phosphine, with a measurement range of 0\u201320 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-PH3-20 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-ph3-20-2-6a98d9d74ae5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-ph3-20-01-phosphine-gas-sensor-datasheet-v1-4-20250304-1360a794d5b4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-so2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-SO2-100\",\"partNumber\":\"01-ES1-SO2-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-SO2-100 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Sulfur Dioxide, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-SO2-100 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-so2-100-1-382db0dfacc0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-so2-100-01-sulfur-dioxide-gas-sensor-datasheet-v1-4-20250228-eadd28c04da5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-so2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-SO2-1000\",\"partNumber\":\"01-ES1-SO2-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"3.5 nA\/ppm \u00b1 1.0 nA\/ppm\",\"signal\":\"3.5 nA\/ppm \u00b1 1.0 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"3.5 nA\/ppm \u00b1 1.0 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-SO2-1000 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Sulfur Dioxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-SO2-1000 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-so2-1000-1-4b29466cda28.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-so2-1000-01-sulfur-dioxide-gas-sensor-datasheet-v1-4-20250228-b90515fc14e6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-so2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-SO2-5\",\"partNumber\":\"01-ES1-SO2-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"ES1-SO2-5 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Sulfur Dioxide, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-SO2-5 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-so2-5-2-607c431620fa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-so2-5-01-sulfur-dioxide-gas-sensor-datasheet-v1-4-20250228-36888928ea5c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es1-so2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES1-SO2-50\",\"partNumber\":\"01-ES1-SO2-50-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es1\",\"series\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES1-SO2-50 is an EC Sense ES1 Solid-Polymer Miniature Series sensor for Sulfur Dioxide, with a measurement range of 0\u201350 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES1-SO2-50 \u662f EC Sense ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es1-so2-50-1-7cf500be2d55.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es1-so2-50-01-sulfur-dioxide-gas-sensor-datasheet-v1-4-20250228-5040ce1488bc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ag1-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-AG1-10\",\"partNumber\":\"01-ES4-AG1-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES4-AG1-10 is an EC Sense ES4 Solid-Polymer 4-Series sensor for All Gas \/ VOC, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES4-AG1-10 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-ag1-10-1-8aa5ec014936.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ag1-10-01-all-gas-sensor-datasheet-v1-4-20250306-f4ba0f14850b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ag1-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-AG1-1000\",\"partNumber\":\"01-ES4-AG1-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"35 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"35 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-AG1-1000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for All Gas \/ VOC, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES4-AG1-1000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-ag1-1000-1-d13db0bbc895.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ag1-1000-01-all-gas-sensor-datasheet-v1-4-20250306-c385b166e020.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ag1-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-AG1-200\",\"partNumber\":\"01-ES4-AG1-200-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"CO: 40 nA\/ppm \u00b1 10 nA\/ppm; C4H8: 55 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-AG1-200 is an EC Sense ES4 Solid-Polymer 4-Series sensor for All Gas \/ VOC, with a measurement range of 0\u2013200 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES4-AG1-200 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013200 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-ag1-200-1-303a5f2b3dac.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ag1-200-01-all-gas-sensor-datasheet-v1-4-20250306-b542af8364f7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ag1-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-AG1-2000\",\"partNumber\":\"01-ES4-AG1-2000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"All Gas \/ VOC\",\"zh\":\"\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"11 nA\/ppm \u00b1 4 nA\/ppm\",\"signal\":\"11 nA\/ppm \u00b1 4 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"11 nA\/ppm \u00b1 4 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-AG1-2000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for All Gas \/ VOC, with a measurement range of 0\u20132000 ppm. Key values are taken from the latest official PDF. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"ES4-AG1-2000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u5168\u6c14\u4f53 \/ \u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20132000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-ag1-2000-1-c7afe76716ee.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ag1-2000-01-all-gas-sensor-datasheet-v1-4-20250306-323c3e88eca0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ash3-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-AsH3-1\",\"partNumber\":\"01-ES4-AsH3-1-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131 ppm\",\"sensitivity\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"signal\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.02 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"120 nA\/ppm \u00b1 40 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.02 ppm\"}],\"description\":{\"en\":\"ES4-AsH3-1 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Arsine, with a measurement range of 0\u20131 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-AsH3-1 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7837\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ash3-1-1-753e328cbe4f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ash3-1-01-arsine-gas-sensor-datasheet-v1-2-20250228-6299a945d4c6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ch4s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-CH4S-10\",\"partNumber\":\"01-ES4-CH4S-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"60 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"60 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"60 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES4-CH4S-10 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Methanethiol \/ Methyl Mercaptan, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"ES4-CH4S-10 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ch4s-10-1-d0ae24951d79.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ch4s-10-01-methyl-mercaptan-gas-sensor-datasheet-v1-5-20250403-8896cd92cdaf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ch4s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-CH4S-100\",\"partNumber\":\"01-ES4-CH4S-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-CH4S-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Methanethiol \/ Methyl Mercaptan, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"ES4-CH4S-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-ch4s-100-1-e6a189fcd48e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ch4s-100-01-methyl-mercaptan-gas-sensor-datasheet-v1-5-20250403-0662b0aa24c9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-co-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-CO-100\",\"partNumber\":\"01-ES4-CO-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100 ppm\",\"sensitivity\":\"30 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"30 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"30 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-CO-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Carbon Monoxide, with a measurement range of 0-100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-CO-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0-100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-co-100-1-60b49bed2baa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-co-100-01-carbon-monoxide-gas-sensor-datasheet-v1-4-20250228-415f516773ce.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-co-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-CO-1000\",\"partNumber\":\"01-ES4-CO-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"25 nA\/ppm + 15 nA\/ppm - 10 nA\/ppm\",\"signal\":\"25 nA\/ppm + 15 nA\/ppm - 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"25 nA\/ppm + 15 nA\/ppm - 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-CO-1000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Carbon Monoxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-CO-1000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-co-1000-1-86e2be9b7637.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-co-1000-01-carbon-monoxide-gas-sensor-datasheet-v1-4-20250228-2ad0c3bf831f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-eto-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-ETO-10\",\"partNumber\":\"01-ES4-ETO-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES4-ETO-10 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Ethylene Oxide, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"ES4-ETO-10 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-eto-10-2-3aebde76ddf7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-eto-10-01-ethylene-oxide-gas-sensor-datasheet-v1-2-20250228-da2454a426fb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-eto-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-ETO-1000\",\"partNumber\":\"01-ES4-ETO-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-ETO-1000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Ethylene Oxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"ES4-ETO-1000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-eto-1000-1-970b9cdee23c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-eto-1000-01-ethylene-oxide-gas-sensor-datasheet-v1-2-20250228-9b45471ced1a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-eto-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-ETO-200\",\"partNumber\":\"01-ES4-ETO-200-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013200 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013200 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-ETO-200 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Ethylene Oxide, with a measurement range of 0\u2013200 ppm. Key values are taken from the latest official PDF. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"ES4-ETO-200 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013200 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-eto-200-1-970b9cdee23c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-eto-200-01-ethylene-oxide-gas-sensor-datasheet-v1-2-20250228-b6bb6bb8182e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-h2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-H2-1000\",\"partNumber\":\"01-ES4-H2-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"9 nA\/ppm \u00b1 4 nA\/ppm\",\"signal\":\"9 nA\/ppm \u00b1 4 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"9 nA\/ppm \u00b1 4 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-H2-1000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-H2-1000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-h2-1000-1-0657fbd232df.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-h2-1000-01-hydrogen-gas-sensor-datasheet-v1-4-20250228-69e1c2a6f488.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-h2-5-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-H2-5%\",\"partNumber\":\"01-ES4-H2-5%-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135% vol.\",\"sensitivity\":\"0.2 nA\/ppm \u00b1 0.1 nA\/ppm\",\"signal\":\"0.2 nA\/ppm \u00b1 0.1 nA\/ppm\",\"responseTime\":\"T50 < 35 s, T90 < 90 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135% vol.\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"0.2 nA\/ppm \u00b1 0.1 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 35 s, T90 < 90 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.001% vol.\"}],\"description\":{\"en\":\"ES4-H2-5% is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen, with a measurement range of 0\u20135% vol.. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-H2-5% \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135% vol.\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-h2-5-white-90993c33d1f3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-h2-5-01-hydrogen-gas-sensor-datasheet-v1-6-20250228-37f8d060d163.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-h2-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-H2-5000\",\"partNumber\":\"01-ES4-H2-5000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5000 ppm\",\"sensitivity\":\"3 nA\/ppm \u00b1 2 nA\/ppm\",\"signal\":\"3 nA\/ppm \u00b1 2 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"3 nA\/ppm \u00b1 2 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"ES4-H2-5000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen, with a measurement range of 0-5000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-H2-5000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0-5000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-h2-5000-2-d90bf2d6c16d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-h2-5000-01-hydrogen-gas-sensor-datasheet-v1-4-20250228-c57df969adcd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-h2s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-H2S-10\",\"partNumber\":\"01-ES4-H2S-10-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201310 ppm\",\"sensitivity\":\"160 nA\/ppm \u00b1 40 nA\/ppm\",\"signal\":\"160 nA\/ppm \u00b1 40 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"160 nA\/ppm \u00b1 40 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES4-H2S-10 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen Sulfide, with a measurement range of 0\u201310 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-H2S-10 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201310 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-h2s-10-5-b8fce4ce5668.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-h2s-10-01-hydrogen-sulfide-gas-sensor-datasheet-v1-4-20250228-49c3d66934c2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-h2s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-H2S-100\",\"partNumber\":\"01-ES4-H2S-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"signal\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"100 nA\/ppm \u00b1 30 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-H2S-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen Sulfide, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-H2S-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-h2s-100-1-1-e1705927570547-08bbf40330d8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-h2s-100-01-hydrogen-sulfide-gas-sensor-datasheet-v1-4-20250228-a8c054f2223c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-h2s-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-H2S-500\",\"partNumber\":\"01-ES4-H2S-500-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013500 ppm\",\"sensitivity\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"signal\":\"100 nA\/ppm \u00b1 30 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013500 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"100 nA\/ppm \u00b1 30 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-H2S-500 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen Sulfide, with a measurement range of 0\u2013500 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-H2S-500 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013500 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-h2s-500-1-e570de7ee6db.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-h2s-500-01-hydrogen-sulfide-gas-sensor-datasheet-v1-4-20250228-c1e869fc2ec0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-h2s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-H2S-5000\",\"partNumber\":\"01-ES4-H2S-5000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135000 ppm\",\"sensitivity\":\"0.28 nA\/ppm \u00b1 0.05 nA\/ppm\",\"signal\":\"0.28 nA\/ppm \u00b1 0.05 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"0.28 nA\/ppm \u00b1 0.05 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-H2S-5000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen Sulfide, with a measurement range of 0\u20135000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-H2S-5000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-h2s-5000-1-22a610aca81b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-h2s-5000-01-hydrogen-sulfide-gas-sensor-datasheet-v1-4-20250228-49ae9f61e3d0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-hcho-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-HCHO-100\",\"partNumber\":\"01-ES4-HCHO-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"signal\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 \u00b0C to +50 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"150 nA\/ppm \u00b1 100 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-HCHO-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Formaldehyde, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-HCHO-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-hcho-100-1-2b744e26b027.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-hcho-100-01-formaldehyde-gas-sensor-datasheet-v1-4-20250228-3616fa69dbea.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-hcho-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-HCHO-5\",\"partNumber\":\"01-ES4-HCHO-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"signal\":\"150 nA\/ppm \u00b1 100 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-20 \u00b0C to +50 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"150 nA\/ppm \u00b1 100 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES4-HCHO-5 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Formaldehyde, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-HCHO-5 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-hcho-5-1-eae186e3d934.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-hcho-5-01-formaldehyde-gas-sensor-datasheet-v1-4-20250228-ceaa97afb7b8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-hcn-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-HCN-5\",\"partNumber\":\"01-ES4-HCN-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 30 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +45 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 30 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-HCN-5 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen Cyanide, with a measurement range of 0-5 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-HCN-5 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0-5 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-hcn-5-31-5729288f0388.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-hcn-5-01-hydrogen-cyanide-sensor-datasheet-v1-0-20260325-fa3e246e12ec.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-hcn-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-HCN-50\",\"partNumber\":\"01-ES4-HCN-50-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-50 ppm\",\"sensitivity\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"signal\":\"40 nA\/ppm \u00b1 15 nA\/ppm\",\"responseTime\":\"T50 < 30 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +45 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-50 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"40 nA\/ppm \u00b1 15 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 30 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-HCN-50 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Hydrogen Cyanide, with a measurement range of 0-50 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-HCN-50 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0-50 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-hcn-50-3-9c8ac9465710.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-hcn-50-01-hydrogen-cyanide-sensor-datasheet-v1-0-20260325-c1e831a45cb1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-nh3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-NH3-100\",\"partNumber\":\"01-ES4-NH3-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T90 < 150 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 150 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-NH3-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Ammonia, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-NH3-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-nh3-100-1-ca4a8141f73e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-nh3-100-01-ammonia-gas-sensor-datasheet-v1-4-20250228-c42e07740f1e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-no2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-NO2-100\",\"partNumber\":\"01-ES4-NO2-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-NO2-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Nitrogen Dioxide, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-NO2-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-no2-100-1-c520d8d7790d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-no2-100-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-3a2d8dc6c808.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-no2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-NO2-1000\",\"partNumber\":\"01-ES4-NO2-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"signal\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-NO2-1000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Nitrogen Dioxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-NO2-1000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-no2-1000-1-548b5403d32c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-no2-1000-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-686f8a94acad.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-no2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-NO2-2000\",\"partNumber\":\"01-ES4-NO2-2000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"signal\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55\u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-6 nA\/ppm \u00b1 2 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-NO2-2000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Nitrogen Dioxide, with a measurement range of 0\u20132000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-NO2-2000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20132000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-no2-2000-1-df0f7bcecdeb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-no2-2000-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-666267b0c78d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-no2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-NO2-50\",\"partNumber\":\"01-ES4-NO2-50-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 10s, T90 < 30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-25 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10s, T90 < 30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-NO2-50 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Nitrogen Dioxide, with a measurement range of 0\u201350 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-NO2-50 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-no2-50-1-5b616ab83730.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-no2-50-01-nitrogen-dioxide-gas-sensor-datasheet-v1-4-20250228-dd82860aa4e7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-o2-25-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-O2-25%\",\"partNumber\":\"01-ES4-O2-25-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"0.23 nA\/ppm \u00b1 0.04 nA\/ppm\",\"signal\":\"0.23 nA\/ppm \u00b1 0.04 nA\/ppm\",\"responseTime\":\"T50 < 5 s, T90 < 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 5 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"0.23 nA\/ppm \u00b1 0.04 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 5 s, T90 < 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01% vol.\"}],\"description\":{\"en\":\"ES4-O2-25% is an EC Sense ES4 Solid-Polymer 4-Series sensor for Oxygen, with a measurement range of 0\u201325% vol.. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-O2-25% \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201325% vol.\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-o2-25-1-1-ed3eeb4419d0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-o2-25-01-oxygen-gas-sensor-datasheet-v1-4-20250228-e28927d94212.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-o3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-O3-100\",\"partNumber\":\"01-ES4-O3-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"signal\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"responseTime\":\"T50 < 40 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 40 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"ES4-O3-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Ozone, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-O3-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-o3-100-1-79f530a9faef.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-o3-100-01-ozone-gas-sensor-datasheet-v1-4-20250228-cd1cf122870a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-o3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-O3-5\",\"partNumber\":\"01-ES4-O3-5-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20135 ppm\",\"sensitivity\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"signal\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\",\"responseTime\":\"T50 < 40 s, T90 < 120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.01 ppm\",\"temperature\":\"-20 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 2 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"-70 nA\/ppm \u00b1 25 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 40 s, T90 < 120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"< 0.01 ppm\"}],\"description\":{\"en\":\"ES4-O3-5 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Ozone, with a measurement range of 0\u20135 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-O3-5 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20135 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-o3-5-2-0ac71d49c285.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-o3-5-01-ozone-gas-sensor-datasheet-v1-4-20250228-c549a86cb652.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-ph3-20\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-PH3-20\",\"partNumber\":\"01-ES4-PH3-20-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"signal\":\"120 nA\/ppm \u00b1 40 nA\/ppm\",\"responseTime\":\"T50 < 10 s, T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"-10 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"120 nA\/ppm \u00b1 40 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 10 s, T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"ES4-PH3-20 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Phosphine, with a measurement range of 0\u201320 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-PH3-20 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-ph3-20-1-3dfec1747f7d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-ph3-20-01-phosphine-gas-sensor-datasheet-v1-4-20250304-5b39c0f7904b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-so2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-SO2-100\",\"partNumber\":\"01-ES4-SO2-100-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-SO2-100 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Sulfur Dioxide, with a measurement range of 0\u2013100 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-SO2-100 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u2013100 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-so2-100-1-8ba38c58877d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-so2-100-01-sulfur-dioxide-gas-sensor-datasheet-v1-4-20250228-30ae2488dcbe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-so2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-SO2-1000\",\"partNumber\":\"01-ES4-SO2-1000-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20131000 ppm\",\"sensitivity\":\"3.5 nA\/ppm \u00b1 1.0 nA\/ppm\",\"signal\":\"3.5 nA\/ppm \u00b1 1.0 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"3.5 nA\/ppm \u00b1 1.0 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-SO2-1000 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Sulfur Dioxide, with a measurement range of 0\u20131000 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-SO2-1000 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u20131000 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-so2-1000-1-55ba27da58a4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-so2-1000-01-sulfur-dioxide-gas-sensor-datasheet-v1-4-20250228-fc82321b247e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:es4-so2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"ES4-SO2-50\",\"partNumber\":\"01-ES4-SO2-50-01\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"ecsense:es4\",\"series\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Solid-Polymer Electrochemical\",\"zh\":\"\u56fa\u4f53\u805a\u5408\u7269\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201350 ppm\",\"sensitivity\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"signal\":\"20 nA\/ppm \u00b1 10 nA\/ppm\",\"responseTime\":\"T50 < 20 s, T90 < 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55\u00b0C\",\"humidity\":\"15\u201395% RH non-condensing\",\"lifetime\":\"> 3 years\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201350 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Sensitivity \/ Signal\",\"zh\":\"\u7075\u654f\u5ea6 \/ \u4fe1\u53f7\"},\"value\":\"20 nA\/ppm \u00b1 10 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T50 < 20 s, T90 < 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"ES4-SO2-50 is an EC Sense ES4 Solid-Polymer 4-Series sensor for Sulfur Dioxide, with a measurement range of 0\u201350 ppm. Key values are taken from the latest official PDF.\",\"zh\":\"ES4-SO2-50 \u662f EC Sense ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff0c\u91cf\u7a0b\u4e3a 0\u201350 ppm\u3002\u5173\u952e\u53c2\u6570\u4ee5\u6700\u65b0\u7248\u539f\u5382 PDF \u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-es4-so2-50-1-8ba38c58877d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-es4-so2-50-01-sulfur-dioxide-gas-sensor-datasheet-v1-4-20250228-4bc26656eaac.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:stox-ammonia\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"Stox Ammonia\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:stox\",\"series\":{\"en\":\"Stox Smart Gas Transmitters\",\"zh\":\"Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u201310 \/ 0\u2013100 \/ 0\u2013500 \/ 0\u20131000 ppm\",\"sensitivity\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"signal\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"responseTime\":\"Long-life: initial <3 s; fast: T90 <60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 \/ 0.01 \/ 0.1 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15 to 95% RH. Non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310 \/ 0\u2013100 \/ 0\u2013500 \/ 0\u20131000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Long-life: initial <3 s; fast: T90 <60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 \/ 0.01 \/ 0.1 ppm\"}],\"description\":{\"en\":\"Stox Ammonia is an EC Sense Stox Smart Gas Transmitters sensing device for Ammonia. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"Stox Ammonia \u662f EC Sense Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-stox-smart-gas-sensor-device-photo1-202208151-scaled-891b4071f5ff.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-smart-ammonia-sensor-device-datasheet-v1-5-20250724-879517f08b3d.pdf\",\"match\":\"exact\"},{\"kind\":\"product-list\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-product-list-v1-0-20250418-df4cdff4366a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:stox\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"Stox\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:stox\",\"series\":{\"en\":\"Stox Smart Gas Transmitters\",\"zh\":\"Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"},\"gas\":\"MULTI_GAS\",\"gasName\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"},\"supportedGases\":[\"CH3SH\",\"HCN\",\"ASH3\",\"SIH4\",\"B2H6\",\"GEH4\",\"HF\",\"O2\",\"NH3\",\"CH2O\",\"CO\",\"CL2\",\"O3\",\"VOC\",\"SO2\",\"NO2\",\"SMELL\",\"H2S\",\"PH3\",\"ETO\",\"H2\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u20131 to 0\u20135000 ppm; % vol. options\",\"sensitivity\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"signal\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"responseTime\":\"Initial typically <3 s; T90 typically <30\u201380 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001\u20131 ppm; 0.001\u20130.01% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15 to 95% RH. Non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 to 0\u20135000 ppm; % vol. options\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Initial typically <3 s; T90 typically <30\u201380 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001\u20131 ppm; 0.001\u20130.01% vol.\"}],\"description\":{\"en\":\"Stox is an EC Sense Stox Smart Gas Transmitters sensing device for Multiple Gases. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"Stox \u662f EC Sense Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\uff0c\u7528\u4e8e\u591a\u6c14\u4f53\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-stox-smart-gas-sensor-device-photo1-202208151-scaled-891b4071f5ff.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-smart-gas-sensor-device-datasheet-v1-5-20250724-96f5993508bb.pdf\",\"match\":\"exact\"},{\"kind\":\"product-list\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-product-list-v1-0-20250418-df4cdff4366a.pdf\",\"match\":\"exact\"}],\"familyOverview\":true,\"embeddedDetails\":true},{\"id\":\"ecsense:stox-hydrogen\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"Stox Hydrogen\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:stox\",\"series\":{\"en\":\"Stox Smart Gas Transmitters\",\"zh\":\"Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u20131000 \/ 0\u20135000 ppm; 0\u20135% vol.\",\"sensitivity\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"signal\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"responseTime\":\"ppm: initial <3 s, T90 <30 s; 5%: initial <35 s, T90 <90 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm; 0.001% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15 to 95% RH. Non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 \/ 0\u20135000 ppm; 0\u20135% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"ppm: initial <3 s, T90 <30 s; 5%: initial <35 s, T90 <90 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm; 0.001% vol.\"}],\"description\":{\"en\":\"Stox Hydrogen is an EC Sense Stox Smart Gas Transmitters sensing device for Hydrogen. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"Stox Hydrogen \u662f EC Sense Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-stox-smart-gas-sensor-device-photo1-202208151-scaled-891b4071f5ff.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-smart-hydrogen-sensor-device-datasheet-v1-5-20250724-6ae182990b06.pdf\",\"match\":\"exact\"},{\"kind\":\"product-list\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-product-list-v1-0-20250418-df4cdff4366a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:stox-oxygen\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"Stox Oxygen\",\"partNumber\":\"05-Stox-O2-25%-01\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:stox\",\"series\":{\"en\":\"Stox Smart Gas Transmitters\",\"zh\":\"Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u201325% vol.\",\"sensitivity\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"signal\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"responseTime\":\"Initial <3 s; T90 <30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15 to 95% RH. Non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Initial <3 s; T90 <30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01% vol.\"}],\"description\":{\"en\":\"Stox Oxygen is an EC Sense Stox Smart Gas Transmitters sensing device for Oxygen. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"Stox Oxygen \u662f EC Sense Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-stox-smart-gas-sensor-device-photo1-202208151-scaled-891b4071f5ff.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-smart-oxygen-sensor-device-datasheet-v1-5-20250724-af4505a8dac9.pdf\",\"match\":\"exact\"},{\"kind\":\"product-list\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-product-list-v1-0-20250418-df4cdff4366a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:stox-ozone\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"Stox Ozone\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:stox\",\"series\":{\"en\":\"Stox Smart Gas Transmitters\",\"zh\":\"Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u20135 \/ 0\u201350 \/ 0\u2013100 ppm\",\"sensitivity\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"signal\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"responseTime\":\"Initial <3 s; T90 <30\u201380 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 \/ 0.01 \/ 0.01 ppm\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15 to 95% RH. Non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20135 \/ 0\u201350 \/ 0\u2013100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Initial <3 s; T90 <30\u201380 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 \/ 0.01 \/ 0.01 ppm\"}],\"description\":{\"en\":\"Stox Ozone is an EC Sense Stox Smart Gas Transmitters sensing device for Ozone. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"Stox Ozone \u662f EC Sense Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-stox-smart-gas-sensor-device-photo1-202208151-scaled-891b4071f5ff.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-smart-ozone-sensor-device-datasheet-v1-5-20250724-a06b44bbaf06.pdf\",\"match\":\"exact\"},{\"kind\":\"product-list\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stox-product-list-v1-0-20250418-df4cdff4366a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:stoxpro\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"StoxPro\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Sensor Device\",\"zh\":\"\u4f20\u611f\u5668\u8bbe\u5907\"},\"seriesKey\":\"ecsense:stoxpro\",\"series\":{\"en\":\"StoxPro Smart Gas Transmitters\",\"zh\":\"StoxPro \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"},\"gas\":\"MULTI_GAS\",\"gasName\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"},\"supportedGases\":[\"HF\",\"CH3SH\",\"HCN\",\"ASH3\",\"SIH4\",\"B2H6\",\"GEH4\",\"O2\",\"NH3\",\"CH2O\",\"CO\",\"CL2\",\"O3\",\"VOC\",\"SO2\",\"NO2\",\"SMELL\",\"H2S\",\"PH3\",\"ETO\",\"H2\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensing Device\",\"zh\":\"\u7535\u5316\u5b66\u68c0\u6d4b\u8bbe\u5907\"},\"specs\":{\"range\":\"0\u20131 to 0\u20135000 ppm; O\u2082 0\u201325% vol.; H\u2082 0\u20135% vol.; CO 0\u20132% vol.\",\"sensitivity\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"signal\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\",\"responseTime\":\"Initial typically <3 s; T90 typically <30\u201380 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001\u20130.1 ppm; 0.001\u20130.01% vol.\",\"temperature\":\"-40 \u00b0C to +55 \u00b0C\",\"humidity\":\"15 to 95% RH. Non-condensing\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131 to 0\u20135000 ppm; O\u2082 0\u201325% vol.; H\u2082 0\u20135% vol.; CO 0\u20132% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire \/ RS485 Modbus-RTU\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Initial typically <3 s; T90 typically <30\u201380 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001\u20130.1 ppm; 0.001\u20130.01% vol.\"}],\"description\":{\"en\":\"StoxPro is an EC Sense StoxPro Smart Gas Transmitters sensing device for Multiple Gases. Key specifications and local manufacturer documents are provided for selection.\",\"zh\":\"StoxPro \u662f EC Sense StoxPro \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\uff0c\u7528\u4e8e\u591a\u6c14\u4f53\u68c0\u6d4b\u3002\u9875\u9762\u63d0\u4f9b\u5173\u952e\u53c2\u6570\u4e0e\u672c\u7ad9\u4fdd\u5b58\u7684\u539f\u5382\u6587\u4ef6\uff0c\u4fbf\u4e8e\u9009\u578b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-stoxpro-white-background-e1769427219249-f1c8e2d2b0cd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stoxpro-smart-gas-sensor-device-datasheet-v2-1-20250728-9bcaa6c487cd.pdf\",\"match\":\"exact\"},{\"kind\":\"product-list\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-stoxpro-product-list-v1-5-20250408-9a49a8a65cc3.pdf\",\"match\":\"exact\"}],\"familyOverview\":true,\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-br2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-Br2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"BR2\",\"gasName\":{\"en\":\"Bromine\",\"zh\":\"\u6eb4\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 60 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 60 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-Br2-5 is an EC Sense TB200B Smart Sensor Modules module for Bromine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-Br2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6eb4\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-br2-5-01-2441bbebc131.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-br2-datasheet-v3-0-20250812-a917d9e105d9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-cl2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-Cl2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 60 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 60 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-Cl2-5 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-Cl2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-cl2-5-01-f056f0e9e2fa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-cl2-datasheet-v3-0-20250812-4d16697b1846.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-cl2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-Cl2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 60 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 60 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-Cl2-50 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-Cl2-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-cl2-50-01-d4461dc6687c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-cl2-datasheet-v3-0-20250812-4d16697b1846.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-clo2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-ClO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 60 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 60 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-ClO2-5 is an EC Sense TB200B Smart Sensor Modules module for Chlorine Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-ClO2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-clo2-5-01-f09dcec876d7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-clo2-datasheet-v3-0-20250812-2e9014bee751.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-f2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-F2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"F2\",\"gasName\":{\"en\":\"Fluorine\",\"zh\":\"\u6c1f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 60 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 60 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-F2-5 is an EC Sense TB200B Smart Sensor Modules module for Fluorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-F2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c1f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-f2-5-01-f0485f2510ed.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-f2-datasheet-v3-0-20250812-ee5f41b14846.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-hcl-30\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-HCl-30\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 30 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 80 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 30 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 80 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-HCl-30 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Chloride. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-HCl-30 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-hcl-30-01-0ca80b6b12f8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-hcl-datasheet-v3-0-20250812-e3a068d0a3fa.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-hf-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-HF-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 80 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 80 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-HF-10 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Fluoride. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-HF-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c1f\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-hf-10-01-149475fe4a26.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-hf-datasheet-v3-0-20250812-ab7bde036c76.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-nh3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-NH3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 50 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 50 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-NH3-100 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-NH3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-nh3-100-white-background-c579f3f47618.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-nh3-datasheet-v3-0-20250812-c47f769dbd0d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-nh3-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-NH3-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 50 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 50 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-NH3-1000 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-NH3-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-nh3-1000-white-background-55971fa0a6e1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-nh3-datasheet-v3-0-20250812-c47f769dbd0d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-nh3-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-NH3-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 50 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 50 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-NH3-500 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-NH3-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-nh3-100-white-background-c579f3f47618.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-nh3-datasheet-v3-0-20250812-c47f769dbd0d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-o3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-O3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 60 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 60 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-O3-100 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-O3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-o3-100-01-2c908360a89a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-o3-datasheet-v3-0-20250812-78cb1ce0c31a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-ec4-o3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-EC4-O3-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"T90 < 60 s.\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 60 s.\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-EC4-O3-5 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-EC4-O3-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-o3-100-01-2c908360a89a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-ec4-o3-datasheet-v3-0-20250812-78cb1ce0c31a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-es4-h2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1&#038;ES4-H2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. ( T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. ( T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1&#038;ES4-H2-1000 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1&#038;ES4-H2-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-h2-1000-01-4b91ae7f79fa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2-datasheet-v3-0-20250812-28e86cf0eb2d.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-es4-h2-5-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1&#038;ES4-H2-5%\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5% vol.\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 90 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001% vol.\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 90 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001% vol.\"}],\"description\":{\"en\":\"TB200B-ES1&#038;ES4-H2-5% is an EC Sense TB200B Smart Sensor Modules module for Hydrogen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1&#038;ES4-H2-5% \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-h2-5-01-c093b8b1be2d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2-datasheet-v3-0-20250812-28e86cf0eb2d.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-es4-h2-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1&#038;ES4-H2-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1&#038;ES4-H2-5000 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1&#038;ES4-H2-5000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-h2-5000-03-6761c786c118.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2-datasheet-v3-0-20250812-28e86cf0eb2d.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-es4-no2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1&#038;ES4-NO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"< 0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"< 0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1&#038;ES4-NO2-5 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1&#038;ES4-NO2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-no2-5-white-background-499ca2ba4346.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-aqi-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-AQI-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. ( T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. ( T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-AQI-10 is an EC Sense TB200B Smart Sensor Modules module for Air Quality. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-AQI-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-aqi-10-white-background-ceba88bd4f3b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-aqi-datasheet-v3-0-20250812-800e4b312695.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-aqi-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-AQI-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-AQI-200 is an EC Sense TB200B Smart Sensor Modules module for Air Quality. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-AQI-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-aqi-200-white-background-f94367878eea.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-aqi-datasheet-v3-0-20250812-800e4b312695.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ash3-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-AsH3-1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. ( T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. ( T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-AsH3-1 is an EC Sense TB200B Smart Sensor Modules module for Arsine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-AsH3-1 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7837\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-aqi-10-white-background-ceba88bd4f3b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ash3-datasheet-v3-0-20250812-e67c7e86fea4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ch4s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CH4S-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CH4S-10 is an EC Sense TB200B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB200B-ES1-CH4S-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ch4s-datasheet-v3-0-20250812-9012e44ca77a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ch4s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CH4S-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CH4S-100 is an EC Sense TB200B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB200B-ES1-CH4S-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ch4s-datasheet-v3-0-20250812-9012e44ca77a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ch4s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CH4S-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CH4S-5000 is an EC Sense TB200B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB200B-ES1-CH4S-5000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ch4s-datasheet-v3-0-20250812-9012e44ca77a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-cl2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-Cl2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-Cl2-100 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-Cl2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-cl2-datasheet-v3-0-20250812-74185270e9bf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-cl2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-Cl2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-Cl2-5 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-Cl2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-cl2-datasheet-v3-0-20250812-74185270e9bf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-cl2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-Cl2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-Cl2-50 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-Cl2-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-cl2-datasheet-v3-0-20250812-74185270e9bf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-clo2-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-ClO2-1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-ClO2-1 is an EC Sense TB200B Smart Sensor Modules module for Chlorine Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-ClO2-1 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-clo2-datasheet-v3-0-20250812-c29bebb59f3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-clo2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-ClO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-ClO2-100 is an EC Sense TB200B Smart Sensor Modules module for Chlorine Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-ClO2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-clo2-datasheet-v3-0-20250812-c29bebb59f3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-clo2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-ClO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-ClO2-5 is an EC Sense TB200B Smart Sensor Modules module for Chlorine Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-ClO2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-ch4s-100-white-background-e0889210549f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-clo2-datasheet-v3-0-20250812-c29bebb59f3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-co-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CO-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CO-10 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-CO-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-co-10-white-background-9ae8df00815f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-co-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CO-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CO-100 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-CO-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-04-eedd681edf51.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-co-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CO-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CO-1000 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-CO-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-1000-04-fff4e4fbdbe4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-co-10000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CO-10000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CO-10000 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-CO-10000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-2-04-2c1ff9ccec52.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-co-2-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CO-2%\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2% vol.\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001% vol.\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001% vol.\"}],\"description\":{\"en\":\"TB200B-ES1-CO-2% is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-CO-2% \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-10-04-09b8725cdee6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-co-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-CO-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-CO-500 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-CO-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-04-eedd681edf51.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-eto-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-ETO-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-ETO-10 is an EC Sense TB200B Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB200B-ES1-ETO-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-04-eedd681edf51.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-eto-datasheet-v3-0-20250812-c403fdd3d85a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-eto-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-ETO-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-ETO-1000 is an EC Sense TB200B Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB200B-ES1-ETO-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-04-eedd681edf51.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-eto-datasheet-v3-0-20250812-c403fdd3d85a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-eto-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-ETO-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-ETO-200 is an EC Sense TB200B Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB200B-ES1-ETO-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-04-eedd681edf51.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-eto-datasheet-v3-0-20250812-c403fdd3d85a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-h2s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-H2S-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-H2S-10 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-H2S-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-h2s-500-white-background-d0f38645b16f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-h2s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-H2S-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-H2S-100 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-H2S-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-h2s-100-white-background-c6e6a344f5f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-h2s-2\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-H2S-2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-H2S-2 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-H2S-2 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-h2s-500-white-background-d0f38645b16f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-h2s-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-H2S-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-H2S-5 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-H2S-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-h2s-500-white-background-d0f38645b16f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-h2s-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-H2S-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-H2S-500 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-H2S-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-h2s-500-white-background-d0f38645b16f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-h2s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-H2S-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-H2S-5000 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-H2S-5000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-h2s-5000-white-background-8fbf59858405.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-hcho-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-HCHO-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-HCHO-100 is an EC Sense TB200B Smart Sensor Modules module for Formaldehyde. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-HCHO-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-hcho-100-white-background-e98ccb606f0d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcho-datasheet-v3-0-20250812-487ef3d64ac4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-hcho-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-HCHO-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-HCHO-5 is an EC Sense TB200B Smart Sensor Modules module for Formaldehyde. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-HCHO-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-hcho-5-white-background-87545d73a2ad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcho-datasheet-v3-0-20250812-487ef3d64ac4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-hcn-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-HCN-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-HCN-5 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Cyanide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-HCN-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcn-datasheet-v3-0-20250812-4203e129077e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-hcn-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-HCN-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-HCN-50 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Cyanide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-HCN-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcn-datasheet-v3-0-20250812-4203e129077e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-nh3-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-NH3-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-NH3-10 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-NH3-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-nh3-datasheet-v3-0-20250812-8f28ae473ef4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-nh3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-NH3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-NH3-100 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-NH3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-nh3-datasheet-v3-0-20250812-8f28ae473ef4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-nh3-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-NH3-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-NH3-50 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-NH3-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-nh3-datasheet-v3-0-20250812-8f28ae473ef4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-no2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-NO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-NO2-100 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-NO2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-no2-100-white-background-ee9c8539d1a4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-no2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-NO2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-NO2-1000 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-NO2-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-no2-1000-white-background-587f4821f749.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-no2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-NO2-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-NO2-2000 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-NO2-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-no2-1000-white-background-587f4821f749.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-no2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-NO2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-NO2-50 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-NO2-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-no2-50-white-background-d752a0acf96b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-o2-25-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-O2-25%\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 25% vol.\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 10 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01% vol.\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 25% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 10 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01% vol.\"}],\"description\":{\"en\":\"TB200B-ES1-O2-25% is an EC Sense TB200B Smart Sensor Modules module for Oxygen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-O2-25% \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-o2-25-04-164a4780e05f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o2-datasheet-v3-0-20250812-b75e6633ca40.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-o3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-O3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-O3-100 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-O3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-o3-100-white-background-5e85eddfcc68.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o3-datasheet-v3-0-20250812-95664a1c5943.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-o3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-O3-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-O3-5 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-O3-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-o3-5-white-background-0e4be880b996.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o3-datasheet-v3-0-20250812-95664a1c5943.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-o3-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-O3-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-O3-50 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-O3-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-o3-50-white-background-59fc56cc5f0d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o3-datasheet-v3-0-20250812-95664a1c5943.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ph3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-PH3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-PH3-100 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-PH3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ph3-20\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-PH3-20\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 20 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 20 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-PH3-20 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-PH3-20 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ph3-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-PH3-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-PH3-2000 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-PH3-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-ph3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-PH3-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-PH3-5 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-PH3-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-ec4-hcn-50-white-background-87e95d8235dd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-smell-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SMELL-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SMELL-10 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SMELL-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-smell-10-white-background-7a29a296659a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-smell-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SMELL-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SMELL-200 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SMELL-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-smell-10-white-background-7a29a296659a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-smell-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SMELL-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SMELL-5 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SMELL-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-smell-10-white-background-7a29a296659a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-smell-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SMELL-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SMELL-500 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SMELL-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-smell-500-white-background-f30592ec71cb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-so2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SO2-100 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SO2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-so2-100-white-background-e7c894009f7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-so2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SO2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SO2-1000 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SO2-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-so2-1000-white-background-085babf59b31.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-so2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SO2-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SO2-2000 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SO2-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-so2-1000-white-background-085babf59b31.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-so2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SO2-5 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SO2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-so2-5-white-background-77b6aa7fd6a0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-so2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-SO2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-SO2-50 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES1-SO2-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-so2-50-white-background-dc924301a17a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-tvoc-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-TVOC-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-TVOC-10 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES1-TVOC-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-bild1-e1616589972806-904e582e48bf.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-tvoc-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-TVOC-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-TVOC-1000 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES1-TVOC-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es1-tvoc-1000-white-background-08d8cb75d876.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-tvoc-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-TVOC-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-TVOC-200 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES1-TVOC-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tvoc-200-04-89f1193e93c2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-tvoc-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-TVOC-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-TVOC-2000 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES1-TVOC-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tvoc-2000-04-83c13ccb45cc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es1-tvoc-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES1-TVOC-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES1-TVOC-500 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES1-TVOC-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tvoc-200-04-89f1193e93c2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-aqi-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-AQI-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. ( T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. ( T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-AQI-10 is an EC Sense TB200B Smart Sensor Modules module for Air Quality. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-AQI-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-aqi-10-2-white-background-734db7ec2848.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-aqi-datasheet-v3-0-20250812-800e4b312695.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-aqi-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-AQI-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-AQI-200 is an EC Sense TB200B Smart Sensor Modules module for Air Quality. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-AQI-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-aqi-200-2-white-background-e17407b877f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-aqi-datasheet-v3-0-20250812-800e4b312695.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ash3-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-AsH3-1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. ( T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. ( T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-AsH3-1 is an EC Sense TB200B Smart Sensor Modules module for Arsine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-AsH3-1 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7837\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-aqi-10-2-white-background-734db7ec2848.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ash3-datasheet-v3-0-20250812-e67c7e86fea4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ch4s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CH4S-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CH4S-10 is an EC Sense TB200B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB200B-ES4-CH4S-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ch4s-datasheet-v3-0-20250812-9012e44ca77a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ch4s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CH4S-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CH4S-100 is an EC Sense TB200B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB200B-ES4-CH4S-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ch4s-datasheet-v3-0-20250812-9012e44ca77a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ch4s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CH4S-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CH4S-5000 is an EC Sense TB200B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB200B-ES4-CH4S-5000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ch4s-datasheet-v3-0-20250812-9012e44ca77a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-cl2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-Cl2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-Cl2-100 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-Cl2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-cl2-datasheet-v3-0-20250812-74185270e9bf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-cl2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-Cl2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-Cl2-5 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-Cl2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-cl2-datasheet-v3-0-20250812-74185270e9bf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-cl2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-Cl2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-Cl2-50 is an EC Sense TB200B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-Cl2-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-cl2-datasheet-v3-0-20250812-74185270e9bf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-clo2-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-ClO2-1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-ClO2-1 is an EC Sense TB200B Smart Sensor Modules module for Chlorine Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-ClO2-1 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-clo2-datasheet-v3-0-20250812-c29bebb59f3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-clo2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-ClO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-ClO2-100 is an EC Sense TB200B Smart Sensor Modules module for Chlorine Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-ClO2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-clo2-datasheet-v3-0-20250812-c29bebb59f3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-clo2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-ClO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-ClO2-5 is an EC Sense TB200B Smart Sensor Modules module for Chlorine Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-ClO2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2f\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-ch4s-100-2-white-background-25ba168e5f71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-clo2-datasheet-v3-0-20250812-c29bebb59f3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-co-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CO-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CO-10 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-CO-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-10-05-e6f90f18d8a5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-co-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CO-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CO-100 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-CO-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-05-7e7305e898a3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-co-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CO-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CO-1000 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-CO-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-1000-02-c2848316cb89.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-co-10000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CO-10000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. ( T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. ( T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CO-10000 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-CO-10000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-2-02-f46790b37e00.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-co-2-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CO-2%\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2% vol.\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001% vol.\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001% vol.\"}],\"description\":{\"en\":\"TB200B-ES4-CO-2% is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-CO-2% \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-10-05-af9d9aaeae23.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-co-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-CO-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-CO-500 is an EC Sense TB200B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-CO-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-05-7e7305e898a3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-co-datasheet-v3-0-20250812-9559d4c7e717.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-eto-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-ETO-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-ETO-10 is an EC Sense TB200B Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB200B-ES4-ETO-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-05-7e7305e898a3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-eto-datasheet-v3-0-20250812-c403fdd3d85a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-eto-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-ETO-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-ETO-1000 is an EC Sense TB200B Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB200B-ES4-ETO-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-05-7e7305e898a3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-eto-datasheet-v3-0-20250812-c403fdd3d85a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-eto-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-ETO-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-ETO-200 is an EC Sense TB200B Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB200B-ES4-ETO-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-co-100-05-7e7305e898a3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-eto-datasheet-v3-0-20250812-c403fdd3d85a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-h2s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-H2S-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-H2S-10 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-H2S-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-h2s-100-2white-background-bc6792abd7f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-h2s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-H2S-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-H2S-100 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-H2S-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-h2s-100-2white-background-bc6792abd7f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-h2s-2\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-H2S-2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-H2S-2 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-H2S-2 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-h2s-100-2white-background-bc6792abd7f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-h2s-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-H2S-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-H2S-5 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-H2S-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-h2s-100-2white-background-bc6792abd7f2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-h2s-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-H2S-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-H2S-500 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-H2S-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-h2s-500-2-white-background-03eef8287b34.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-h2s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-H2S-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-H2S-5000 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-H2S-5000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-h2s-5000-2-white-background-3f3538d3c890.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-h2s-datasheet-v3-0-20250812-f3d9e2a05e57.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-hcho-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-HCHO-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-HCHO-100 is an EC Sense TB200B Smart Sensor Modules module for Formaldehyde. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-HCHO-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-hcho-100-2-white-background-42eabe2319d7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcho-datasheet-v3-0-20250812-487ef3d64ac4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-hcho-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-HCHO-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-HCHO-5 is an EC Sense TB200B Smart Sensor Modules module for Formaldehyde. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-HCHO-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-hcho-5-2-white-background-c9170d7b03d1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcho-datasheet-v3-0-20250812-487ef3d64ac4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-hcn-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-HCN-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-HCN-5 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Cyanide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-HCN-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-hcn-50-2-white-background-8e7063fdc960.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcn-datasheet-v3-0-20250812-4203e129077e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-hcn-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-HCN-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-HCN-50 is an EC Sense TB200B Smart Sensor Modules module for Hydrogen Cyanide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-HCN-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-hcn-50-2-white-background-8e7063fdc960.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-hcn-datasheet-v3-0-20250812-4203e129077e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-nh3-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-NH3-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-NH3-10 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-NH3-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-hcn-50-2-white-background-8e7063fdc960.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-nh3-datasheet-v3-0-20250812-8f28ae473ef4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-nh3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-NH3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-NH3-100 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-NH3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-hcn-50-2-white-background-8e7063fdc960.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-nh3-datasheet-v3-0-20250812-8f28ae473ef4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-nh3-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-NH3-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-NH3-50 is an EC Sense TB200B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-NH3-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-hcn-50-2-white-background-8e7063fdc960.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-nh3-datasheet-v3-0-20250812-8f28ae473ef4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-no2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-NO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-NO2-100 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-NO2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-100-2-white-background-5577c87cc05a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-no2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-NO2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-NO2-1000 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-NO2-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-1000-2-white-background-4c0e76b31aa4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-no2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-NO2-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-NO2-2000 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-NO2-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-1000-2-white-background-4c0e76b31aa4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-no2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-NO2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-NO2-50 is an EC Sense TB200B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-NO2-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-50-2-white-background-6bdebbd81464.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-no2-datasheet-v3-0-20250812-54d3499f5fde.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-o2-25-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-O2-25%\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 25% vol.\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 10 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01% vol.\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 25% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 10 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01% vol.\"}],\"description\":{\"en\":\"TB200B-ES4-O2-25% is an EC Sense TB200B Smart Sensor Modules module for Oxygen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-O2-25% \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c27\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-o2-25-05-1-7b6bbf582e1d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o2-datasheet-v3-0-20250812-b75e6633ca40.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-o3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-O3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-O3-100 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-O3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-o3-100-1-white-background-feb21e412f58.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o3-datasheet-v3-0-20250812-95664a1c5943.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-o3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-O3-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-O3-5 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-O3-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-o3-5-2-white-background-443641a647bb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o3-datasheet-v3-0-20250812-95664a1c5943.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-o3-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-O3-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-O3-50 is an EC Sense TB200B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-O3-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-o3-50-2-white-background-45be82630a5f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-o3-datasheet-v3-0-20250812-95664a1c5943.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ph3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-PH3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-PH3-100 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-PH3-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-1000-2-white-background-4c0e76b31aa4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ph3-20\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-PH3-20\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 20 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 20 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-PH3-20 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-PH3-20 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-1000-2-white-background-4c0e76b31aa4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ph3-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-PH3-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-PH3-2000 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-PH3-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-1000-2-white-background-4c0e76b31aa4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-ph3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-PH3-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-PH3-5 is an EC Sense TB200B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-PH3-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-no2-1000-2-white-background-4c0e76b31aa4.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-ph3-datasheet-v3-0-20250812-716aa21c7f6e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-smell-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SMELL-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SMELL-10 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SMELL-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-smell-10-2-white-background-8d9e34e6afd9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-smell-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SMELL-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SMELL-200 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SMELL-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-smell-10-2-white-background-8d9e34e6afd9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-smell-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SMELL-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SMELL-5 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SMELL-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-smell-10-2-white-background-8d9e34e6afd9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-smell-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SMELL-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SMELL-500 is an EC Sense TB200B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SMELL-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-smell-500-2-white-background-721aa7b76d10.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-smell-datasheet-v3-0-20250812-f3fdd0f69bd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-so2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SO2-100 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SO2-100 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-so2-100-2-white-background-19810324565f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-so2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SO2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SO2-1000 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SO2-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-so2-1000-2-white-background-8cd8d13542ee.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-so2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SO2-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SO2-2000 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SO2-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-so2-1000-2-white-background-8cd8d13542ee.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-so2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SO2-5 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SO2-5 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-so2-5-2-white-background-cd1ed56a4eb1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-so2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-SO2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-SO2-50 is an EC Sense TB200B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB200B-ES4-SO2-50 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-so2-100-2-white-background-19810324565f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-so2-datasheet-v3-0-20250812-0f092eb6d548.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-tvoc-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-TVOC-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-TVOC-10 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES4-TVOC-10 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-tvoc-10-2-white-background-bigger-16f3287241fa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-tvoc-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-TVOC-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-TVOC-1000 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES4-TVOC-1000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb200b-es4-tvoc-1000-2-white-background-313567705d4d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-tvoc-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-TVOC-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-TVOC-200 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES4-TVOC-200 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tvoc-200-02-c4f4d694cb1f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-tvoc-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-TVOC-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-TVOC-2000 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES4-TVOC-2000 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tvoc-2000-05-90fa735a59eb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb200b-es4-tvoc-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB200B-ES4-TVOC-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb200b\",\"series\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB200B-ES4-TVOC-500 is an EC Sense TB200B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB200B-ES4-TVOC-500 \u662f EC Sense TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tvoc-200-02-c4f4d694cb1f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb200b-es1es4-tvoc-datasheet-v3-0-20250812-a6fd91f07145.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb420-ec4\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB420-EC4\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb420\",\"series\":{\"en\":\"TB420 4-20 mA Sensor Modules\",\"zh\":\"TB420 4-20 mA \u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"MULTI_GAS\",\"gasName\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"},\"supportedGases\":[\"NH3\",\"HF\",\"HCL\",\"F2\",\"CLO2\",\"CL2\",\"BR2\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"Sensor-dependent; see datasheet\",\"sensitivity\":\"4\u201320 mA two-wire\",\"signal\":\"4\u201320 mA two-wire\",\"responseTime\":\"Sensor-dependent; see datasheet\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u00b15% full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Sensor-dependent; see datasheet\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Sensor-dependent; see datasheet\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u00b15% full scale\"}],\"description\":{\"en\":\"TB420-EC4 is an EC Sense TB420 4-20 mA Sensor Modules module for Multiple Gases. Its main output\/interface is 4\u201320 mA two-wire; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB420-EC4 \u662f EC Sense TB420 4-20 mA \u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u591a\u6c14\u4f53\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a 4\u201320 mA two-wire\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-gimp-added-white-background-skaliert-tb420-ec4-1-b254b418e831.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb420-ec4-smart-gas-sensor-module-datasheet-v2-0-20250415-bf74bff69a5d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb420-es1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB420-ES1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb420\",\"series\":{\"en\":\"TB420 4-20 mA Sensor Modules\",\"zh\":\"TB420 4-20 mA \u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"MULTI_GAS\",\"gasName\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"},\"supportedGases\":[\"ETO\",\"PH3\",\"ASH3\",\"VOC\",\"SO2\",\"SMELL\",\"O3\",\"O2\",\"NO2\",\"NH3\",\"H2S\",\"HCN\",\"CH2O\",\"H2\",\"CO\",\"CL2\",\"CH3SH\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"Sensor-dependent; see datasheet\",\"sensitivity\":\"4\u201320 mA two-wire\",\"signal\":\"4\u201320 mA two-wire\",\"responseTime\":\"Sensor-dependent; see datasheet\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u00b15% full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Sensor-dependent; see datasheet\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Sensor-dependent; see datasheet\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u00b15% full scale\"}],\"description\":{\"en\":\"TB420-ES1 is an EC Sense TB420 4-20 mA Sensor Modules module for Multiple Gases. Its main output\/interface is 4\u201320 mA two-wire; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB420-ES1 \u662f EC Sense TB420 4-20 mA \u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u591a\u6c14\u4f53\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a 4\u201320 mA two-wire\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-gimp-added-white-background-skaliert-tb420-es1-1-c47d0149373b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb420-es1-smart-gas-sensor-module-datasheet-v2-0-20250331-318aaba84542.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb420-es4\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB420-ES4\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb420\",\"series\":{\"en\":\"TB420 4-20 mA Sensor Modules\",\"zh\":\"TB420 4-20 mA \u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"MULTI_GAS\",\"gasName\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"},\"supportedGases\":[\"ASH3\",\"ETO\",\"PH3\",\"VOC\",\"SO2\",\"SMELL\",\"O3\",\"O2\",\"NO2\",\"NH3\",\"H2S\",\"HCN\",\"CH2O\",\"H2\",\"CO\",\"CL2\",\"CH3SH\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"Sensor-dependent; see datasheet\",\"sensitivity\":\"4\u201320 mA two-wire\",\"signal\":\"4\u201320 mA two-wire\",\"responseTime\":\"Sensor-dependent; see datasheet\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u00b15% full scale\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"Sensor-dependent; see datasheet\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"4\u201320 mA two-wire\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"Sensor-dependent; see datasheet\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"\u00b15% full scale\"}],\"description\":{\"en\":\"TB420-ES4 is an EC Sense TB420 4-20 mA Sensor Modules module for Multiple Gases. Its main output\/interface is 4\u201320 mA two-wire; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB420-ES4 \u662f EC Sense TB420 4-20 mA \u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u591a\u6c14\u4f53\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a 4\u201320 mA two-wire\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-gimp-added-white-background-skaliert-tb420-es4-1-dab838826887.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb420-es4-smart-gas-sensor-module-datasheet-v2-0-20250331-b36f4ac29afa.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-aqi-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-AQI-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-AQI-10 is an EC Sense TB600B Smart Sensor Modules module for Air Quality. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-AQI-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-aqi-datasheet-v3-0-20250904-b5b8456005df.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-ash3-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-AsH3-1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-AsH3-1 is an EC Sense TB600B Smart Sensor Modules module for Arsine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-AsH3-1 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7837\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-ash3-datasheet-v3-0-20250904-7434858c7948.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-ch4s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-CH4S-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-CH4S-10 is an EC Sense TB600B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB600B-CH4S-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-ch4s-datasheet-v3-0-20250904-0de543a31838.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-ch4s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-CH4S-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-CH4S-100 is an EC Sense TB600B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB600B-CH4S-100 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-ch4s-datasheet-v3-0-20250904-0de543a31838.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-ch4s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-CH4S-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol \/ Methyl Mercaptan\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600B-CH4S-5000 is an EC Sense TB600B Smart Sensor Modules module for Methanethiol \/ Methyl Mercaptan. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: CH3SH, CH4S, methanethiol, methyl mercaptan.\",\"zh\":\"TB600B-CH4S-5000 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u786b\u9187\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aCH3SH\u3001CH4S\u3001\u7532\u786b\u9187\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-ch4s-datasheet-v3-0-20250904-0de543a31838.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-cl2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-Cl2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-Cl2-5 is an EC Sense TB600B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-Cl2-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-cl2-datasheet-v3-0-20250904-cd1aae89ff99.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-cl2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-Cl2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-Cl2-50 is an EC Sense TB600B Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-Cl2-50 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-cl2-datasheet-v3-0-20250904-cd1aae89ff99.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-co-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-CO-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-CO-10 is an EC Sense TB600B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-CO-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-co-datasheet-v3-0-20250904-b01e98f085d9.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-co-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-CO-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-CO-100 is an EC Sense TB600B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-CO-100 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-co-datasheet-v3-0-20250904-b01e98f085d9.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-co-10000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-CO-10000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"1 ppm\"}],\"description\":{\"en\":\"TB600B-CO-10000 is an EC Sense TB600B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-CO-10000 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-co-datasheet-v3-0-20250904-b01e98f085d9.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-co-2-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-CO-2%\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2% vol.\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001% vol.\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001% vol.\"}],\"description\":{\"en\":\"TB600B-CO-2% is an EC Sense TB600B Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-CO-2% \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-co-datasheet-v3-0-20250904-b01e98f085d9.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-eto-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-ETO-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-ETO-10 is an EC Sense TB600B Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB600B-ETO-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-eto-datasheet-v3-0-20250904-81703e6b3f77.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-h2s-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-H2S-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-H2S-10 is an EC Sense TB600B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-H2S-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-h2s-datasheet-v3-0-20250904-702c4043242a.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-h2s-2\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-H2S-2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-H2S-2 is an EC Sense TB600B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-H2S-2 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-h2s-datasheet-v3-0-20250904-702c4043242a.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-h2s-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-H2S-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-H2S-5 is an EC Sense TB600B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-H2S-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-h2s-datasheet-v3-0-20250904-702c4043242a.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-h2s-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-H2S-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600B-H2S-5000 is an EC Sense TB600B Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-H2S-5000 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-h2s-datasheet-v3-0-20250904-702c4043242a.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-hcn-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-HCN-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-HCN-5 is an EC Sense TB600B Smart Sensor Modules module for Hydrogen Cyanide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-HCN-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-hcn-datasheet-v3-0-20250904-bd229f62db84.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-hcn-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-HCN-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-HCN-50 is an EC Sense TB600B Smart Sensor Modules module for Hydrogen Cyanide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-HCN-50 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c30\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-hcn-datasheet-v3-0-20250904-bd229f62db84.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-iaq-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-IAQ-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-IAQ-10 is an EC Sense TB600B Smart Sensor Modules module for Air Quality. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-IAQ-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-iaq-datasheet-v3-0-20250904-11db90163914.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-nh3-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-NH3-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-NH3-10 is an EC Sense TB600B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-NH3-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-nh3-datasheet-v3-0-20250904-9f3c5474d687.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-nh3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-NH3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-NH3-100 is an EC Sense TB600B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-NH3-100 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-nh3-datasheet-v3-0-20250904-9f3c5474d687.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-nh3-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-NH3-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 min.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 min.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-NH3-50 is an EC Sense TB600B Smart Sensor Modules module for Ammonia. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-NH3-50 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c28\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-nh3-datasheet-v3-0-20250904-9f3c5474d687.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-no2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-NO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T50 < 10 s. \/ T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T50 < 10 s. \/ T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600B-NO2-100 is an EC Sense TB600B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-NO2-100 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-no2-datasheet-v3-0-20250904-fd72a01e0329.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-no2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-NO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-NO2-5 is an EC Sense TB600B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-NO2-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-no2-datasheet-v3-0-20250904-fd72a01e0329.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-no2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-NO2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-NO2-50 is an EC Sense TB600B Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-NO2-50 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-no2-datasheet-v3-0-20250904-fd72a01e0329.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-o3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-O3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-O3-100 is an EC Sense TB600B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-O3-100 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-o3-datasheet-v3-0-20250904-b0ac98e401ef.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-o3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-O3-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-O3-5 is an EC Sense TB600B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-O3-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-o3-datasheet-v3-0-20250904-b0ac98e401ef.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-o3-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-O3-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-O3-50 is an EC Sense TB600B Smart Sensor Modules module for Ozone. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-O3-50 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u81ed\u6c27\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-o3-datasheet-v3-0-20250904-b0ac98e401ef.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-ph3-20\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-PH3-20\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 20 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 20 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-PH3-20 is an EC Sense TB600B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-PH3-20 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-ph3-datasheet-v3-0-20250904-f6c50edd0c6e.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-ph3-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-PH3-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600B-PH3-2000 is an EC Sense TB600B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-PH3-2000 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-ph3-datasheet-v3-0-20250904-f6c50edd0c6e.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-ph3-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-PH3-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-PH3-5 is an EC Sense TB600B Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-PH3-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-ph3-datasheet-v3-0-20250904-f6c50edd0c6e.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-smell-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-SMELL-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-SMELL-10 is an EC Sense TB600B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-SMELL-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-smell-datasheet-v3-0-20250926-ba7e35ae30dd.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-smell-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-SMELL-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-SMELL-5 is an EC Sense TB600B Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-SMELL-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-smell-datasheet-v3-0-20250926-ba7e35ae30dd.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-so2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-SO2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-SO2-100 is an EC Sense TB600B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-SO2-100 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-so2-datasheet-v3-0-20250904-2a945e46ab11.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-so2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-SO2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600B-SO2-1000 is an EC Sense TB600B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-SO2-1000 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-so2-datasheet-v3-0-20250904-2a945e46ab11.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-so2-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-SO2-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-SO2-5 is an EC Sense TB600B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-SO2-5 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-so2-datasheet-v3-0-20250904-2a945e46ab11.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-so2-50\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-SO2-50\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 50 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 50 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600B-SO2-50 is an EC Sense TB600B Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-SO2-50 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-so2-datasheet-v3-0-20250904-2a945e46ab11.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-tvoc-10\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-TVOC-10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 10 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 10 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-TVOC-10 is an EC Sense TB600B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB600B-TVOC-10 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-tvoc-datasheet-v3-0-20250904-82c0c484a239.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-tvoc-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-TVOC-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600B-TVOC-200 is an EC Sense TB600B Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB600B-TVOC-200 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-tvoc-datasheet-v3-0-20250904-82c0c484a239.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600b-wq-hcho-1\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600B-WQ-HCHO-1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600b\",\"series\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600B-WQ-HCHO-1 is an EC Sense TB600B Smart Sensor Modules module for Formaldehyde. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600B-WQ-HCHO-1 \u662f EC Sense TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600b-wq-hcho-datasheet-v3-0-20250904-284ad2851835.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-cl2-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-Cl2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600C-Cl2-100 is an EC Sense TB600C Smart Sensor Modules module for Chlorine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-Cl2-100 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c2f\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-cl2-datasheet-v3-0-20250904-cd1aae89ff99.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-co-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-CO-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-CO-1000 is an EC Sense TB600C Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-CO-1000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-co-datasheet-v3-0-20250904-b01e98f085d9.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-co-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-CO-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600C-CO-500 is an EC Sense TB600C Smart Sensor Modules module for Carbon Monoxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-CO-500 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e00\u6c27\u5316\u78b3\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-co-datasheet-v3-0-20250904-b01e98f085d9.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-eto-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-ETO-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-ETO-1000 is an EC Sense TB600C Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB600C-ETO-1000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-eto-datasheet-v3-0-20250904-81703e6b3f77.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-eto-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-ETO-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-ETO-200 is an EC Sense TB600C Smart Sensor Modules module for Ethylene Oxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: ETO, EO, C2H4O, ethylene oxide.\",\"zh\":\"TB600C-ETO-200 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u73af\u6c27\u4e59\u70f7\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aETO\u3001EO\u3001C2H4O\u3001\u73af\u6c27\u4e59\u70f7\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-eto-datasheet-v3-0-20250904-81703e6b3f77.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-h2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-H2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-H2-1000 is an EC Sense TB600C Smart Sensor Modules module for Hydrogen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-H2-1000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600c-h2-datasheet-v3-0-20250904-bee8ea8575cb.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-h2-5-pct\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-H2-5%\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5% vol.\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 90 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001% vol.\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5% vol.\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 90 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001% vol.\"}],\"description\":{\"en\":\"TB600C-H2-5% is an EC Sense TB600C Smart Sensor Modules module for Hydrogen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-H2-5% \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600c-h2-datasheet-v3-0-20250904-bee8ea8575cb.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-h2-5000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-H2-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-H2-5000 is an EC Sense TB600C Smart Sensor Modules module for Hydrogen. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-H2-5000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u6c22\u6c14\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600c-h2-datasheet-v3-0-20250904-bee8ea8575cb.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-h2s-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-H2S-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600C-H2S-100 is an EC Sense TB600C Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-H2S-100 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-h2s-datasheet-v3-0-20250904-702c4043242a.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-h2s-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-H2S-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-H2S-1000 is an EC Sense TB600C Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-H2S-1000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-h2s-datasheet-v3-0-20250904-702c4043242a.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-h2s-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-H2S-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600C-H2S-500 is an EC Sense TB600C Smart Sensor Modules module for Hydrogen Sulfide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-H2S-500 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u786b\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-h2s-datasheet-v3-0-20250904-702c4043242a.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-hcho-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-HCHO-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 60 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 60 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600C-HCHO-100 is an EC Sense TB600C Smart Sensor Modules module for Formaldehyde. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-HCHO-100 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600c-hcho-datasheet-v3-0-20250904-6548ec3bb583.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-hcho-5\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-HCHO-5\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 5 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.001 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 5 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.001 ppm\"}],\"description\":{\"en\":\"TB600C-HCHO-5 is an EC Sense TB600C Smart Sensor Modules module for Formaldehyde. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-HCHO-5 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7532\u919b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600c-hcho-datasheet-v3-0-20250904-6548ec3bb583.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-iaq-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-IAQ-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600C-IAQ-200 is an EC Sense TB600C Smart Sensor Modules module for Air Quality. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-IAQ-200 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-iaq-datasheet-v3-0-20250904-11db90163914.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-no2-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-NO2-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-NO2-1000 is an EC Sense TB600C Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-NO2-1000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-no2-datasheet-v3-0-20250904-fd72a01e0329.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-no2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-NO2-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-NO2-2000 is an EC Sense TB600C Smart Sensor Modules module for Nitrogen Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-NO2-2000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u6c2e\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-no2-datasheet-v3-0-20250904-fd72a01e0329.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-ph3-100\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-PH3-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 100 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 80 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 100 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 80 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.01 ppm\"}],\"description\":{\"en\":\"TB600C-PH3-100 is an EC Sense TB600C Smart Sensor Modules module for Phosphine. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-PH3-100 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u78f7\u5316\u6c22\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600b-uart-smart-gas-sensor-module-image1-20230920-9aecf8aae9c7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-ph3-datasheet-v3-0-20250904-f6c50edd0c6e.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-smell-200\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-SMELL-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 200 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 200 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-SMELL-200 is an EC Sense TB600C Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-SMELL-200 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-smell-datasheet-v3-0-20250926-ba7e35ae30dd.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-smell-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-SMELL-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SMELL\",\"gasName\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-SMELL-500 is an EC Sense TB600C Smart Sensor Modules module for Odor \/ Smell. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-SMELL-500 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u5f02\u5473\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-smell-datasheet-v3-0-20250926-ba7e35ae30dd.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-so2-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-SO2-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-SO2-2000 is an EC Sense TB600C Smart Sensor Modules module for Sulfur Dioxide. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions.\",\"zh\":\"TB600C-SO2-2000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u4e8c\u6c27\u5316\u786b\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-so2-datasheet-v3-0-20250904-2a945e46ab11.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-tvoc-1000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-TVOC-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 1000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 1000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-TVOC-1000 is an EC Sense TB600C Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB600C-TVOC-1000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-tvoc-datasheet-v3-0-20250904-82c0c484a239.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-tvoc-2000\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-TVOC-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 2000 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 2000 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-TVOC-2000 is an EC Sense TB600C Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB600C-TVOC-2000 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-tvoc-datasheet-v3-0-20250904-82c0c484a239.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"ecsense:tb600c-tvoc-500\",\"brandKey\":\"ecsense\",\"brandName\":\"EC Sense\",\"model\":\"TB600C-TVOC-500\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u5757\"},\"seriesKey\":\"ecsense:tb600c\",\"series\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Total VOC\",\"zh\":\"\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical Sensor Module\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u5757\"},\"specs\":{\"range\":\"0 \u2013 500 ppm\",\"sensitivity\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"signal\":\"UART TTL 3.3V or I\u00b2C digital signal\",\"responseTime\":\"< 3 s. (T90 < 30 s.)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"\",\"humidity\":\"\",\"lifetime\":\"\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 \u2013 500 ppm\"},{\"key\":\"output\",\"label\":{\"en\":\"Output \/ Interface\",\"zh\":\"\u8f93\u51fa \/ \u63a5\u53e3\"},\"value\":\"UART TTL 3.3V or I\u00b2C digital signal\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 3 s. (T90 < 30 s.)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution \/ Accuracy\",\"zh\":\"\u5206\u8fa8\u7387 \/ \u7cbe\u5ea6\"},\"value\":\"0.1 ppm\"}],\"description\":{\"en\":\"TB600C-TVOC-500 is an EC Sense TB600C Smart Sensor Modules module for Total VOC. Its main output\/interface is UART TTL 3.3V or I\u00b2C digital signal; refer to the attached manufacturer documents for integration conditions. Search aliases: VOC, TVOC, all-gas, air quality.\",\"zh\":\"TB600C-TVOC-500 \u662f EC Sense TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\uff0c\u7528\u4e8e\u603b\u6325\u53d1\u6027\u6709\u673a\u7269\u68c0\u6d4b\uff1b\u4e3b\u8981\u8f93\u51fa\/\u63a5\u53e3\u4e3a UART TTL 3.3V or I\u00b2C digital signal\u3002\u96c6\u6210\u6761\u4ef6\u8bf7\u4ee5\u968f\u9644\u539f\u5382\u6587\u4ef6\u4e3a\u51c6\u3002 \u68c0\u7d22\u522b\u540d\uff1aVOC\u3001TVOC\u3001\u5168\u6c14\u4f53\u3001\u7a7a\u6c14\u8d28\u91cf\u3002 \"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/images\/ecsense-tb600c-uart-smart-gas-sensor-module-image1-20230920-f89c8bb306e7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-tvoc-datasheet-v3-0-20250904-82c0c484a239.pdf\",\"match\":\"exact\"},{\"kind\":\"user-guide\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/ecsense\/documents\/ecsense-tb600bc-user-guide-v1-1-20250219-a151503c9dc6.pdf\",\"match\":\"reference\"}],\"documentNote\":{\"en\":\"Some supporting files cover the product series rather than only this exact configuration; verify the model table before design use.\",\"zh\":\"\u90e8\u5206\u652f\u6301\u6587\u4ef6\u8986\u76d6\u6574\u4e2a\u4ea7\u54c1\u7cfb\u5217\uff0c\u5e76\u975e\u4ec5\u5bf9\u5e94\u8fd9\u4e00\u914d\u7f6e\uff1b\u8bbe\u8ba1\u4f7f\u7528\u524d\u8bf7\u6838\u5bf9\u6587\u4ef6\u4e2d\u7684\u578b\u53f7\u8868\u3002\"},\"embeddedDetails\":true},{\"id\":\"sgx:ec410\",\"brandKey\":\"sgx\",\"brandName\":\"SGX Sensortech\",\"model\":\"EC410\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"sgx:4-series-electrochemical\",\"series\":{\"en\":\"4-Series Electrochemical Sensors\",\"zh\":\"\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201330% O\u2082\",\"sensitivity\":\"300\u2013400 \u00b5A at 20.9% O\u2082; 40 \u00b5A in N\u2082\",\"signal\":\"300\u2013400 \u00b5A at 20.9% O\u2082; 40 \u00b5A in N\u2082\",\"responseTime\":\"T90 < 15 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1% O\u2082\",\"temperature\":\"\u221220 to +55 \u00b0C\",\"temperatureZh\":\"\u221220 \u81f3 +55 \u00b0C\",\"humidity\":\"15\u201395% RH (non-condensing)\",\"humidityZh\":\"15\u201395% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\">36 months\",\"lifetimeZh\":\"\u8d85\u8fc7 36 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201330% O\u2082\",\"valueZh\":\"0\u201330% O\u2082\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"300\u2013400 \u00b5A at 20.9% O\u2082; 40 \u00b5A in N\u2082\",\"valueZh\":\"\u5728 20.9% O\u2082 \u4e2d\u4e3a 300\u2013400 \u00b5A\uff1b\u5728 N\u2082 \u4e2d\u4e3a 40 \u00b5A\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 15 s\",\"valueZh\":\"T90 < 15 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% O\u2082\",\"valueZh\":\"0.1% O\u2082\"}],\"description\":{\"en\":\"EC410 is an electrochemical oxygen sensor covering 0\u201330% O\u2082. Its current output is 300\u2013400 \u00b5A in 20.9% O\u2082, with a T90 response below 15 seconds.\",\"zh\":\"EC410 \u662f\u91cf\u7a0b\u4e3a 0\u201330% O\u2082 \u7684\u7535\u5316\u5b66\u6c27\u6c14\u4f20\u611f\u5668\uff1b\u5728 20.9% O\u2082 \u4e2d\u8f93\u51fa 300\u2013400 \u00b5A\uff0cT90 \u54cd\u5e94\u65f6\u95f4\u5c0f\u4e8e 15 \u79d2\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/images\/sgx-ec410-031efb7a770f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/documents\/sgx-ec410-e38f6513ddf8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"sgx:sgx-4co\",\"brandKey\":\"sgx\",\"brandName\":\"SGX Sensortech\",\"model\":\"SGX-4CO\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"sgx:4-series-electrochemical\",\"series\":{\"en\":\"4-Series Electrochemical Sensors\",\"zh\":\"\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"70 \u00b1 20 nA\/ppm\",\"signal\":\"70 \u00b1 20 nA\/ppm\",\"responseTime\":\"T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"<0.5 ppm typical\",\"temperature\":\"\u221230 to +50 \u00b0C\",\"temperatureZh\":\"\u221230 \u81f3 +50 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"humidityZh\":\"15\u201390% RH\",\"lifetime\":\">24 months in air\",\"lifetimeZh\":\"\u7a7a\u6c14\u4e2d\u8d85\u8fc7 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\",\"valueZh\":\"0\u20132000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"70 \u00b1 20 nA\/ppm\",\"valueZh\":\"70 \u00b1 20 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 30 s\",\"valueZh\":\"T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<0.5 ppm typical\",\"valueZh\":\"\u5178\u578b\u503c <0.5 ppm\"}],\"description\":{\"en\":\"SGX-4CO is a 4-series industrial carbon monoxide sensor with a 0\u20132000 ppm range and 70 \u00b1 20 nA\/ppm output signal.\",\"zh\":\"SGX-4CO \u662f 4 \u7cfb\u5217\u5de5\u4e1a\u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91cf\u7a0b 0\u20132000 ppm\uff0c\u8f93\u51fa\u4fe1\u53f7\u4e3a 70 \u00b1 20 nA\/ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/images\/sgx-sgx-4co-b266d39e739d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/documents\/sgx-sgx-4co-2bf46efd8e95.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"sgx:sgx-4dt\",\"brandKey\":\"sgx\",\"brandName\":\"SGX Sensortech\",\"model\":\"SGX-4DT\",\"partNumber\":\"\",\"aliases\":[\"Dual-Tox CO\/H2S\"],\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"sgx:4-series-electrochemical\",\"series\":{\"en\":\"4-Series Electrochemical Sensors\",\"zh\":\"\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4f20\u611f\u5668\"},\"gas\":\"CO_H2S\",\"gasName\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"},\"supportedGases\":[\"CO\",\"H2S\"],\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"CO 0\u20131000 ppm; H\u2082S 0\u2013100 ppm\",\"sensitivity\":\"CO 60\u2013120 nA\/ppm; H\u2082S 500\u20131100 nA\/ppm\",\"signal\":\"CO 60\u2013120 nA\/ppm; H\u2082S 500\u20131100 nA\/ppm\",\"responseTime\":\"CO T90 < 30 s; H\u2082S T90 < 35 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"CO \u00b11 ppm typical; H\u2082S \u00b10.5 ppm typical\",\"temperature\":\"\u221230 to +50 \u00b0C\",\"temperatureZh\":\"\u221230 \u81f3 +50 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"humidityZh\":\"15\u201390% RH\",\"lifetime\":\">24 months in air\",\"lifetimeZh\":\"\u7a7a\u6c14\u4e2d\u8d85\u8fc7 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"CO 0\u20131000 ppm; H\u2082S 0\u2013100 ppm\",\"valueZh\":\"CO\uff1a0\u20131000 ppm\uff1bH\u2082S\uff1a0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"CO 60\u2013120 nA\/ppm; H\u2082S 500\u20131100 nA\/ppm\",\"valueZh\":\"CO\uff1a60\u2013120 nA\/ppm\uff1bH\u2082S\uff1a500\u20131100 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"CO T90 < 30 s; H\u2082S T90 < 35 s\",\"valueZh\":\"CO\uff1aT90 < 30 s\uff1bH\u2082S\uff1aT90 < 35 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"CO \u00b11 ppm typical; H\u2082S \u00b10.5 ppm typical\",\"valueZh\":\"CO\uff1a\u5178\u578b\u503c \u00b11 ppm\uff1bH\u2082S\uff1a\u5178\u578b\u503c \u00b10.5 ppm\"}],\"description\":{\"en\":\"SGX-4DT is a dual-channel electrochemical sensor for carbon monoxide and hydrogen sulfide, providing independent CO and H\u2082S outputs in one 4-series housing.\",\"zh\":\"SGX-4DT \u662f\u4e00\u6b3e\u53cc\u901a\u9053\u7535\u5316\u5b66\u4f20\u611f\u5668\uff0c\u5728\u4e00\u4e2a 4 \u7cfb\u5217\u5916\u58f3\u4e2d\u5206\u522b\u8f93\u51fa\u4e00\u6c27\u5316\u78b3\u4e0e\u786b\u5316\u6c22\u4fe1\u53f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/images\/sgx-sgx-4dt-5c1a25da943a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/documents\/sgx-sgx-4dt-7e748963ffa7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"sgx:sgx-4h2s\",\"brandKey\":\"sgx\",\"brandName\":\"SGX Sensortech\",\"model\":\"SGX-4H2S\",\"partNumber\":\"\",\"aliases\":[\"SGX-4H2S-100\"],\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"sgx:4-series-electrochemical\",\"series\":{\"en\":\"4-Series Electrochemical Sensors\",\"zh\":\"\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u2013100 ppm\",\"sensitivity\":\"700 \u00b1 250 nA\/ppm\",\"signal\":\"700 \u00b1 250 nA\/ppm\",\"responseTime\":\"T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Not specified; maximum overload 500 ppm\",\"temperature\":\"\u221230 to +50 \u00b0C\",\"temperatureZh\":\"\u221230 \u81f3 +50 \u00b0C\",\"humidity\":\"15\u201390% RH (non-condensing)\",\"humidityZh\":\"15\u201390% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"2-year warranty\",\"lifetimeZh\":\"2 \u5e74\u4fdd\u4fee\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm\",\"valueZh\":\"0\u2013100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"700 \u00b1 250 nA\/ppm\",\"valueZh\":\"700 \u00b1 250 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 30 s\",\"valueZh\":\"T90 < 30 s\"},{\"key\":\"maximumOverload\",\"label\":{\"en\":\"Maximum Overload\",\"zh\":\"\u6700\u5927\u8fc7\u8f7d\"},\"value\":\"500 ppm\",\"valueZh\":\"500 ppm\"}],\"description\":{\"en\":\"SGX-4H2S is the 0\u2013100 ppm hydrogen sulfide sensor listed in the SGX China electrochemical catalog. SGX-4H2S-100 is retained as a search alias for the current global listing.\",\"zh\":\"SGX-4H2S \u662f SGX \u4e2d\u56fd\u7535\u5316\u5b66\u76ee\u5f55\u6240\u5217\u7684 0\u2013100 ppm \u786b\u5316\u6c22\u4f20\u611f\u5668\uff1bSGX-4H2S-100 \u4f5c\u4e3a\u5f53\u524d\u5168\u7403\u76ee\u5f55\u7684\u68c0\u7d22\u522b\u540d\u4fdd\u7559\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/images\/sgx-sgx-4h2s-854834d3135d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/documents\/sgx-sgx-4h2s-c6fe7335a469.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"sgx:sgx-4ox\",\"brandKey\":\"sgx\",\"brandName\":\"SGX Sensortech\",\"model\":\"SGX-4OX\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"sgx:4-series-electrochemical\",\"series\":{\"en\":\"4-Series Electrochemical Sensors\",\"zh\":\"\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201325% O\u2082\",\"sensitivity\":\"70\u2013130 \u00b5A in air\",\"signal\":\"70\u2013130 \u00b5A in air\",\"responseTime\":\"T90 < 15 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Not specified; maximum overload 30% O\u2082\",\"temperature\":\"\u221230 to +50 \u00b0C\",\"temperatureZh\":\"\u221230 \u81f3 +50 \u00b0C\",\"humidity\":\"5\u201395% RH (non-condensing)\",\"humidityZh\":\"5\u201395% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\">2 years in air\",\"lifetimeZh\":\"\u7a7a\u6c14\u4e2d\u8d85\u8fc7 2 \u5e74\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201325% O\u2082\",\"valueZh\":\"0\u201325% O\u2082\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"70\u2013130 \u00b5A in air\",\"valueZh\":\"\u7a7a\u6c14\u4e2d 70\u2013130 \u00b5A\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 15 s\",\"valueZh\":\"T90 < 15 s\"},{\"key\":\"maximumOverload\",\"label\":{\"en\":\"Maximum Overload\",\"zh\":\"\u6700\u5927\u8fc7\u8f7d\"},\"value\":\"30% O\u2082\",\"valueZh\":\"30% O\u2082\"}],\"description\":{\"en\":\"SGX-4OX is a 4-series electrochemical oxygen sensor for portable gas detectors, covering 0\u201325% O\u2082 with a 70\u2013130 \u00b5A output in air.\",\"zh\":\"SGX-4OX \u662f\u9762\u5411\u4fbf\u643a\u5f0f\u6c14\u4f53\u68c0\u6d4b\u4eea\u7684 4 \u7cfb\u5217\u7535\u5316\u5b66\u6c27\u6c14\u4f20\u611f\u5668\uff0c\u91cf\u7a0b 0\u201325% O\u2082\uff0c\u7a7a\u6c14\u4e2d\u8f93\u51fa 70\u2013130 \u00b5A\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/images\/sgx-sgx-4ox-39b09db306aa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/documents\/sgx-sgx-4ox-1712dbfc69f8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"sgx:sgx-4so2-2000\",\"brandKey\":\"sgx\",\"brandName\":\"SGX Sensortech\",\"model\":\"SGX-4SO2-2000\",\"partNumber\":\"\",\"aliases\":[\"SGX-4SO2-E\"],\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"sgx:4-series-electrochemical\",\"series\":{\"en\":\"4-Series Electrochemical Sensors\",\"zh\":\"\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u20132000 ppm\",\"sensitivity\":\"60 \u00b1 20 nA\/ppm\",\"signal\":\"60 \u00b1 20 nA\/ppm\",\"responseTime\":\"T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"<1 ppm typical\",\"temperature\":\"\u221220 to +50 \u00b0C\",\"temperatureZh\":\"\u221220 \u81f3 +50 \u00b0C\",\"humidity\":\"15\u201390% RH\",\"humidityZh\":\"15\u201390% RH\",\"lifetime\":\">24 months in air\",\"lifetimeZh\":\"\u7a7a\u6c14\u4e2d\u8d85\u8fc7 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm\",\"valueZh\":\"0\u20132000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"60 \u00b1 20 nA\/ppm\",\"valueZh\":\"60 \u00b1 20 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 30 s\",\"valueZh\":\"T90 < 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"<1 ppm typical\",\"valueZh\":\"\u5178\u578b\u503c <1 ppm\"}],\"description\":{\"en\":\"SGX-4SO2-2000 is a high-range electrochemical sulfur dioxide sensor for emissions analyzers and industrial monitoring, covering 0\u20132000 ppm.\",\"zh\":\"SGX-4SO2-2000 \u662f\u7528\u4e8e\u6392\u653e\u5206\u6790\u4e0e\u5de5\u4e1a\u76d1\u6d4b\u7684\u9ad8\u91cf\u7a0b\u7535\u5316\u5b66\u4e8c\u6c27\u5316\u786b\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u20132000 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/images\/sgx-sgx-4h2s-854834d3135d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/documents\/sgx-sgx-4so2-2000-fd8bfd90514c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"sgx:sgx-7co-aq-20\",\"brandKey\":\"sgx\",\"brandName\":\"SGX Sensortech\",\"model\":\"SGX-7CO-AQ-20\",\"partNumber\":\"\",\"aliases\":[\"7-Series Air Quality CO\"],\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"sgx:7-series-air-quality\",\"series\":{\"en\":\"7-Series Air Quality Sensors\",\"zh\":\"\u4e03\u7cfb\u5217\u7a7a\u6c14\u8d28\u91cf\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0\u201320 ppm\",\"sensitivity\":\"350 \u00b1 100 nA\/ppm\",\"signal\":\"350 \u00b1 100 nA\/ppm\",\"responseTime\":\"T90 < 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Not specified; maximum overload 200 ppm\",\"temperature\":\"\u221230 to +50 \u00b0C\",\"temperatureZh\":\"\u221230 \u81f3 +50 \u00b0C\",\"humidity\":\"15\u201390% RH (non-condensing)\",\"humidityZh\":\"15\u201390% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\">24 months in air\",\"lifetimeZh\":\"\u7a7a\u6c14\u4e2d\u8d85\u8fc7 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm\",\"valueZh\":\"0\u201320 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"350 \u00b1 100 nA\/ppm\",\"valueZh\":\"350 \u00b1 100 nA\/ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 < 30 s\",\"valueZh\":\"T90 < 30 s\"},{\"key\":\"maximumOverload\",\"label\":{\"en\":\"Maximum Overload\",\"zh\":\"\u6700\u5927\u8fc7\u8f7d\"},\"value\":\"200 ppm\",\"valueZh\":\"200 ppm\"}],\"description\":{\"en\":\"SGX-7CO-AQ-20 is a four-electrode, low-concentration carbon monoxide sensor for outdoor air-quality systems, with a 0\u201320 ppm range.\",\"zh\":\"SGX-7CO-AQ-20 \u662f\u9762\u5411\u5ba4\u5916\u7a7a\u6c14\u8d28\u91cf\u7cfb\u7edf\u7684\u56db\u7535\u6781\u4f4e\u6d53\u5ea6\u4e00\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u91cf\u7a0b\u4e3a 0\u201320 ppm\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/images\/sgx-sgx-7co-aq-20-50f53562385a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"en\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/sgx\/documents\/sgx-sgx-7co-aq-20-b24caf5056c9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hcho-dm-12027908\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HCHO-DM\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -10 ppm\",\"sensitivity\":\"550\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"550\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 90s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -10 ppm\",\"valueZh\":\"0 -10 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"550\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"550\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 90s\",\"valueZh\":\"< 90s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.05 ppm\",\"valueZh\":\"0.05 ppm\"}],\"description\":{\"en\":\"4HCHO-DM is a SUSA electrochemical formaldehyde sensor with a measurement range of 0 -10 ppm, an output signal or sensitivity of 550\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 90s.\",\"zh\":\"\u65e0\u504f\u7f6e\u7535\u538b\uff1b\u68c0\u6d4b\u8303\u56f4\uff1a0 -10 ppm\uff1b\u7075\u654f\u5ea6\uff1a550\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 90s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hcho-dm-12027908-03d7ad592c8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hcho-dm-12027908-343bfe22702a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4o2-gs-12027906\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4O2-GS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0~25% O2\",\"sensitivity\":\"100\u00b120\u00b5A in air\",\"signal\":\"100\u00b120\u00b5A in air\",\"responseTime\":\"10s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1% O2\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"5 \u5e74\",\"lifetimeZh\":\"5 \u5e74\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0~25% O2\",\"valueZh\":\"0~25% O2\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"100\u00b120\u00b5A in air\",\"valueZh\":\"100\u00b120\u00b5A in air\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"10s\",\"valueZh\":\"10s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% O2\",\"valueZh\":\"0.1% O2\"}],\"description\":{\"en\":\"4O2-GS is a SUSA electrochemical oxygen sensor with a measurement range of 0~25% O2, an output signal or sensitivity of 100\u00b120\u00b5A in air, a response time of 10s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0~25% O2\uff1b\u6781\u9650\u8d1f\u8f7d\uff1a30% O2\uff1b\u8f93\u51fa\u4fe1\u53f7\uff1a100\u00b120\u00b5A in air\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a 10s\uff1b\u504f\u7f6e\u7535\u538b\uff1a-600mv\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4o2-gs-12027906-9bd9484180e9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4o2-gs-12027906-bea0ec959aaf.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:nh3-ar-10690153\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"NH3-AR\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -100 ppm\",\"sensitivity\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 90s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -100 ppm\",\"valueZh\":\"0 -100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 90s\",\"valueZh\":\"< 90s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\",\"valueZh\":\"0.5 ppm\"}],\"description\":{\"en\":\"NH3-AR is a SUSA electrochemical ammonia sensor with a measurement range of 0 -100 ppm, an output signal or sensitivity of 150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 90s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -100 ppm\uff1b\u7075\u654f\u5ea6\uff1a150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 90s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-nh3-ar-10690153-d334347abeda.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-nh3-ar-10690153-a0cfc37d4af6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4co-6350242\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CO\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000ppm\",\"sensitivity\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<25 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 2000ppm\",\"valueZh\":\"0 - 2000ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<25 s\",\"valueZh\":\"<25 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4CO is a SUSA electrochemical carbon monoxide sensor with a measurement range of 0 - 2000ppm, an output signal or sensitivity of 75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <25 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 2000ppm\uff1b\u7075\u654f\u5ea6\uff1a75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<25 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4co-6350242-b1177ae97667.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4co-6350242-b0c7d7d9ee1e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4co-sf-6350243\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CO-SF\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000ppm\",\"sensitivity\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 2000ppm\",\"valueZh\":\"0 - 2000ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<15 s\",\"valueZh\":\"<15 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4CO-SF is a SUSA electrochemical carbon monoxide sensor with a measurement range of 0 - 2000ppm, an output signal or sensitivity of 75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <15 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 2000ppm\uff1b\u7075\u654f\u5ea6\uff1a75\u00b115 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<15 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4co-sf-6350243-f25cc4b38aba.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4co-sf-6350243-fad1615ef858.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4co-af-6350244\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CO-AF\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100ppm\",\"sensitivity\":\"200\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"200\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<15 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 100ppm\",\"valueZh\":\"0 - 100ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"200\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"200\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<15 s\",\"valueZh\":\"<15 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\",\"valueZh\":\"0.5 ppm\"}],\"description\":{\"en\":\"4CO-AF is a SUSA electrochemical carbon monoxide sensor with a measurement range of 0 - 100ppm, an output signal or sensitivity of 200\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <15 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 100ppm\uff1b\u7075\u654f\u5ea6\uff1a200\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<15 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4co-af-6350244-23fa4df64cc1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4co-af-6350244-acbda38833f0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4h2s-as-6350256\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4H2S-AS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100ppm\",\"sensitivity\":\"800\u00b1200 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"800\u00b1200 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0 C\",\"temperatureZh\":\"-40 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 100ppm\",\"valueZh\":\"0 - 100ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"800\u00b1200 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"800\u00b1200 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\",\"valueZh\":\"<30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4H2S-AS is a SUSA electrochemical hydrogen sulfide sensor with a measurement range of 0 - 100ppm, an output signal or sensitivity of 800\u00b1200 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <30 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 100ppm\uff1b\u7075\u654f\u5ea6\uff1a800\u00b1200 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<30 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4h2s-as-6350256-c49f6503acbc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4h2s-as-6350256-48119bb000fb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4no2-ct-6350252\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4NO2-CT\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20ppm\",\"sensitivity\":\"600\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"600\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 20ppm\",\"valueZh\":\"0 - 20ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"600\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"600\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\",\"valueZh\":\"<30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4NO2-CT is a SUSA electrochemical nitrogen dioxide sensor with a measurement range of 0 - 20ppm, an output signal or sensitivity of 600\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of <30 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 20ppm\uff1b\u7075\u654f\u5ea6\uff1a600\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<30 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4no2-ct-6350252-8a277fc0ac1a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4no2-ct-6350252-23e9a6b1fb16.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4nh3-sr-10690154\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4NH3-SR\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -500 ppm\",\"sensitivity\":\"50\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"50\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 90s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"3 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -500 ppm\",\"valueZh\":\"0 -500 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"50\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"50\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 90s\",\"valueZh\":\"< 90s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"3 ppm\",\"valueZh\":\"3 ppm\"}],\"description\":{\"en\":\"4NH3-SR is a SUSA electrochemical ammonia sensor with a measurement range of 0 -500 ppm, an output signal or sensitivity of 50\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 90s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -500 ppm\uff1b\u7075\u654f\u5ea6\uff1a50\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 90s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4nh3-sr-10690154-4bc84a7a8b1d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4nh3-sr-10690154-cb43b59e3184.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4sih4-ls-10256316\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4SiH4-LS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -50 ppm\",\"sensitivity\":\"130\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"130\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 45s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-40 to 50\u00b0 C\",\"temperatureZh\":\"-40 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -50 ppm\",\"valueZh\":\"0 -50 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"130\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"130\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 45s\",\"valueZh\":\"< 45s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\",\"valueZh\":\"0.5 ppm\"}],\"description\":{\"en\":\"4SiH4-LS is a SUSA electrochemical silane sensor with a measurement range of 0 -50 ppm, an output signal or sensitivity of 130\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 45s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -50 ppm\uff1b\u7075\u654f\u5ea6\uff1a130\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 45s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4sih4-ls-10256316-abbdf1ec08f1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4sih4-ls-10256316-76b30d4ff5a6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4so2-nt-10256317\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4SO2-NT\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -1000 ppm\",\"sensitivity\":\"50\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"50\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -1000 ppm\",\"valueZh\":\"0 -1000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"50\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"50\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 60s\",\"valueZh\":\"< 60s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4SO2-NT is a SUSA electrochemical sulfur dioxide sensor with a measurement range of 0 -1000 ppm, an output signal or sensitivity of 50\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 60s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -1000 ppm\uff1b\u7075\u654f\u5ea6\uff1a50\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 60s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4so2-nt-10256317-ade5b7d4a5df.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4so2-nt-10256317-d9a2cb2d897f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4tht-lt-10256318\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4THT-LT\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u5668\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -50 mg\/m3\",\"sensitivity\":\"140\u00b1 50nA\/mg\/m3\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"140\u00b1 50nA\/mg\/m3\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 120s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.3 mg\/m3\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -50 mg\/m3\",\"valueZh\":\"0 -50 mg\/m3\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"140\u00b1 50nA\/mg\/m3\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"140\u00b1 50nA\/mg\/m3\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 120s\",\"valueZh\":\"< 120s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.3 mg\/m3\",\"valueZh\":\"0.3 mg\/m3\"}],\"description\":{\"en\":\"4THT-LT is a SUSA electrochemical tetrahydrothiophene sensor with a measurement range of 0 -50 mg\/m3, an output signal or sensitivity of 140\u00b1 50nA\/mg\/m3\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 120s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -50 mg\/m3\uff1b\u7075\u654f\u5ea6\uff1a140\u00b1 50nA\/mg\/m3\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 120s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4tht-lt-10256318-346bcafe2af0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4tht-lt-10256318-7e481ca40bd7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hcl-lr-10256313\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HCL-LR\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -50 ppm\",\"sensitivity\":\"300\u00b180nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"300\u00b180nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -50 ppm\",\"valueZh\":\"0 -50 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"300\u00b180nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"300\u00b180nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 60s\",\"valueZh\":\"< 60s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4HCL-LR is a SUSA electrochemical hydrogen chloride sensor with a measurement range of 0 -50 ppm, an output signal or sensitivity of 300\u00b180nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 60s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -50 ppm\uff1b\u7075\u654f\u5ea6\uff1a300\u00b180nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 60s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hcl-lr-10256313-9b9fa025a85a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hcl-lr-10256313-de2f78ec4d93.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hcn-lm-10256314\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HCN-LM\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -50 ppm\",\"sensitivity\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 120s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -50 ppm\",\"valueZh\":\"0 -50 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 120s\",\"valueZh\":\"< 120s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.2 ppm\",\"valueZh\":\"0.2 ppm\"}],\"description\":{\"en\":\"4HCN-LM is a SUSA electrochemical hydrogen cyanide sensor with a measurement range of 0 -50 ppm, an output signal or sensitivity of 150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 120s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -50 ppm\uff1b\u7075\u654f\u5ea6\uff1a150\u00b1 50nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 120s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hcn-lm-10256314-9c66c4e0f973.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hcn-lm-10256314-be66b134edb8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4nh3-ns-10256315\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4NH3-NS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -1000 ppm\",\"sensitivity\":\"60\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"60\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 90s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -1000 ppm\",\"valueZh\":\"0 -1000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"60\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"60\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 90s\",\"valueZh\":\"< 90s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"4NH3-NS is a SUSA electrochemical ammonia sensor with a measurement range of 0 -1000 ppm, an output signal or sensitivity of 60\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 90s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -1000 ppm\uff1b\u7075\u654f\u5ea6\uff1a60\u00b1 20nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 90s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4nh3-ns-10256315-c37dde8c2657.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4nh3-ns-10256315-2071b1ef54fc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hcho-ls-10256312\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HCHO-LS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -50 ppm\",\"sensitivity\":\"500\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"500\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 90s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0 C\",\"temperatureZh\":\"-20 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -50 ppm\",\"valueZh\":\"0 -50 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"500\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"500\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 90s\",\"valueZh\":\"< 90s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4HCHO-LS is a SUSA electrochemical formaldehyde sensor with a measurement range of 0 -50 ppm, an output signal or sensitivity of 500\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 90s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -50 ppm\uff1b\u7075\u654f\u5ea6\uff1a500\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 90s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hcho-ls-10256312-6c90ae6af06e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hcho-ls-10256312-0c96077b4ccd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4eto-dm-10256309\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4ETO-DM\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"\u2014\",\"sensitivity\":\"\u2014\",\"signal\":\"\u2014\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"4ETO-DM is a SUSA electrochemical ethylene oxide sensor.\",\"zh\":\"4ETO-DM \u662f SUSA\uff08\u82cf\u8428\uff09\u7535\u5316\u5b66\u73af\u6c27\u4e59\u70f7\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4eto-dm-10256309-8a92edf1b760.webp\",\"documents\":[],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"The manufacturer product page did not publish a PDF document for this model.\",\"zh\":\"\u539f\u5382\u4ea7\u54c1\u9875\u672a\u516c\u5f00\u8be5\u578b\u53f7\u7684 PDF \u8d44\u6599\u3002\"}},{\"id\":\"susa:4h2-ft-10256310\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4H2-FT\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -40000 ppm\",\"sensitivity\":\"8\u00b1 5nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"8\u00b1 5nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 70s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"10 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -40000 ppm\",\"valueZh\":\"0 -40000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"8\u00b1 5nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"8\u00b1 5nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 70s\",\"valueZh\":\"< 70s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\",\"valueZh\":\"10 ppm\"}],\"description\":{\"en\":\"4H2-FT is a SUSA electrochemical hydrogen sensor with a measurement range of 0 -40000 ppm, an output signal or sensitivity of 8\u00b1 5nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 70s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -40000 ppm\uff1b\u7075\u654f\u5ea6\uff1a8\u00b1 5nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 70s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4h2-ft-10256310-9bc7244632da.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4h2-ft-10256310-dc7e518294de.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hcho-ds-10256311\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HCHO-DS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -10 ppm\",\"sensitivity\":\"2000\u00b1 800nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"2000\u00b1 800nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 90s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01ppm\",\"temperature\":\"-20 to 50\u00b0 C\",\"temperatureZh\":\"-20 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -10 ppm\",\"valueZh\":\"0 -10 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"2000\u00b1 800nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"2000\u00b1 800nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 90s\",\"valueZh\":\"< 90s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01ppm\",\"valueZh\":\"0.01ppm\"}],\"description\":{\"en\":\"4HCHO-DS is a SUSA electrochemical formaldehyde sensor with a measurement range of 0 -10 ppm, an output signal or sensitivity of 2000\u00b1 800nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 90s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -10 ppm\uff1b\u7075\u654f\u5ea6\uff1a2000\u00b1 800nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 90s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hcho-ds-10256311-e6a11704c559.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hcho-ds-10256311-d55cf168af3e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4eto-am-10256308\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4ETO-AM\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -100 ppm\",\"sensitivity\":\"400\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"400\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -100 ppm\",\"valueZh\":\"0 -100 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"400\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"400\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 60s\",\"valueZh\":\"< 60s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4ETO-AM is a SUSA electrochemical ethylene oxide sensor with a measurement range of 0 -100 ppm, an output signal or sensitivity of 400\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 60s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -100 ppm\uff1b\u7075\u654f\u5ea6\uff1a400\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 60s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4eto-am-10256308-db7f75969724.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4eto-am-10256308-032cde7b6917.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4cocl2-vs-10256307\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4COCL2-VS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"COCL2\",\"gasName\":{\"en\":\"Phosgene\",\"zh\":\"\u5149\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -1 ppm\",\"sensitivity\":\"300\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"300\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 120s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.02 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -1 ppm\",\"valueZh\":\"0 -1 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"300\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"300\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 120s\",\"valueZh\":\"< 120s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.02 ppm\",\"valueZh\":\"0.02 ppm\"}],\"description\":{\"en\":\"4COCL2-VS is a SUSA electrochemical phosgene sensor with a measurement range of 0 -1 ppm, an output signal or sensitivity of 300\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 120s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -1 ppm\uff1b\u7075\u654f\u5ea6\uff1a300\u00b1 100nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 120s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4cocl2-vs-10256307-e5fe3297051c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4cocl2-vs-10256307-0363ecc2cbd9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4clo2-vs-10256304\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CLO2-VS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -5 ppm\",\"sensitivity\":\"650\u00b1 200nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"650\u00b1 200nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.03 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -5 ppm\",\"valueZh\":\"0 -5 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"650\u00b1 200nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"650\u00b1 200nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 60s\",\"valueZh\":\"< 60s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.03 ppm\",\"valueZh\":\"0.03 ppm\"}],\"description\":{\"en\":\"4CLO2-VS is a SUSA electrochemical chlorine dioxide sensor with a measurement range of 0 -5 ppm, an output signal or sensitivity of 650\u00b1 200nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of < 60s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -5 ppm\uff1b\u7075\u654f\u5ea6\uff1a650\u00b1 200nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 60s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4clo2-vs-10256304-d89f69dc1770.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4clo2-vs-10256304-c0b5aae774ad.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4c2h4-ds-10256172\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4C2H4-DS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -10 ppm\",\"sensitivity\":\"400\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"400\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -10 ppm\",\"valueZh\":\"0 -10 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"400\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"400\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 60s\",\"valueZh\":\"< 60s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4C2H4-DS is a SUSA electrochemical ethylene sensor with a measurement range of 0 -10 ppm, an output signal or sensitivity of 400\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 60s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -10 ppm\uff1b\u7075\u654f\u5ea6\uff1a400\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 60s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4c2h4-ds-10256172-a8f7d6adfe5e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4c2h4-ds-10256172-a45984ca31e2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4c2h2-ds-10256040\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4C2H2-DS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10ppm\",\"sensitivity\":\"450\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"450\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 10ppm\",\"valueZh\":\"0 - 10ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"450\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"450\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4C2H2-DS is a SUSA electrochemical acetylene sensor with a measurement range of 0 - 10ppm, an output signal or sensitivity of 450\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 10ppm\uff1b\u7075\u654f\u5ea6\uff1a450\u00b1 80nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4c2h2-ds-10256040-1e245e80d6dc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4c2h2-ds-10256040-9f44fd65577e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4ash3-vs-10256037\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4AsH3-VS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ASH3\",\"gasName\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -1 ppm\",\"sensitivity\":\"1400\u00b1 400nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"1400\u00b1 400nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"15 ppb\",\"temperature\":\"-20 to 50\u00b0 C\",\"temperatureZh\":\"-20 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -1 ppm\",\"valueZh\":\"0 -1 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1400\u00b1 400nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"1400\u00b1 400nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\",\"valueZh\":\"<30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"15 ppb\",\"valueZh\":\"15 ppb\"}],\"description\":{\"en\":\"4AsH3-VS is a SUSA electrochemical arsine sensor with a measurement range of 0 -1 ppm, an output signal or sensitivity of 1400\u00b1 400nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <30 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -1 ppm\uff1b\u7075\u654f\u5ea6\uff1a1400\u00b1 400nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<30 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4ash3-vs-10256037-1cf1c135ee06.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4ash3-vs-10256037-9c5d490543b4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4ph3-cs-10183147\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PH3-CS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20ppm\",\"sensitivity\":\"1500\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"1500\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0 C\",\"temperatureZh\":\"-40 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 20ppm\",\"valueZh\":\"0 - 20ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1500\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"1500\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4PH3-CS is a SUSA electrochemical phosphine sensor with a measurement range of 0 - 20ppm, an output signal or sensitivity of 1500\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 20ppm\uff1b\u7075\u654f\u5ea6\uff1a1500\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4ph3-cs-10183147-878dbe052cfa.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4ph3-cs-10183147-3ab4144206a1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4ph3-ns-6350298\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PH3-NS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000ppm\",\"sensitivity\":\"90\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"90\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 to 50\u00b0 C\",\"temperatureZh\":\"-40 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 1000ppm\",\"valueZh\":\"0 - 1000ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"90\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"90\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4PH3-NS is a SUSA electrochemical phosphine sensor with a measurement range of 0 - 1000ppm, an output signal or sensitivity of 90\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 1000ppm\uff1b\u7075\u654f\u5ea6\uff1a90\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4ph3-ns-6350298-df1c28654868.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4ph3-ns-6350298-32383bc38f4b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4c3h3n-as-6350292\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4C3H3N-AS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C3H3N\",\"gasName\":{\"en\":\"Acrylonitrile\",\"zh\":\"\u4e19\u70ef\u816d\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100ppm\",\"sensitivity\":\"60\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"60\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<90 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 100ppm\",\"valueZh\":\"0 - 100ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"60\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"60\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<90 s\",\"valueZh\":\"<90 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4C3H3N-AS is a SUSA electrochemical acrylonitrile sensor with a measurement range of 0 - 100ppm, an output signal or sensitivity of 60\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <90 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 100ppm\uff1b\u7075\u654f\u5ea6\uff1a60\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<90 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4c3h3n-as-6350292-dc801634cf76.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4c3h3n-as-6350292-cc2bc9ae38de.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hf-cs-6350285\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HF-CS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20ppm\",\"sensitivity\":\"400\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"400\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 20ppm\",\"valueZh\":\"0 - 20ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"400\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"400\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<120 s\",\"valueZh\":\"<120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4HF-CS is a SUSA electrochemical hydrogen fluoride sensor with a measurement range of 0 - 20ppm, an output signal or sensitivity of 400\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of <120 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 20ppm\uff1b\u7075\u654f\u5ea6\uff1a400\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<120 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hf-cs-6350285-7ba7a8481683.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hf-cs-6350285-5479051077f9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hcl-ls-6350283\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HCL-LS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50ppm\",\"sensitivity\":\"300\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"300\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<70 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 50ppm\",\"valueZh\":\"0 - 50ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"300\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"300\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<70 s\",\"valueZh\":\"<70 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4HCL-LS is a SUSA electrochemical hydrogen chloride sensor with a measurement range of 0 - 50ppm, an output signal or sensitivity of 300\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <70 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 50ppm\uff1b\u7075\u654f\u5ea6\uff1a300\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<70 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hcl-ls-6350283-3773387a2b34.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hcl-ls-6350283-608796c7c46a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4so2-ct-6350260\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4SO2-CT\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20ppm\",\"sensitivity\":\"500\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"500\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 20ppm\",\"valueZh\":\"0 - 20ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"500\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"500\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\",\"valueZh\":\"<30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4SO2-CT is a SUSA electrochemical sulfur dioxide sensor with a measurement range of 0 - 20ppm, an output signal or sensitivity of 500\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <30 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 20ppm\uff1b\u7075\u654f\u5ea6\uff1a500\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<30 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4so2-ct-6350260-483ef5ed825f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4so2-ct-6350260-d9a5f5024cfc.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4o2-gp-6350258\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4O2-GP\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 to 25% O2\",\"sensitivity\":\"100\u00b120\u03bcA in air\",\"signal\":\"100\u00b120\u03bcA in air\",\"responseTime\":\"\uff1c15 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01% O2\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15% to 90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15% to 90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 2 \u5e74\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 2 \u5e74\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 to 25% O2\",\"valueZh\":\"0 to 25% O2\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"100\u00b120\u03bcA in air\",\"valueZh\":\"100\u00b120\u03bcA in air\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\uff1c15 s\",\"valueZh\":\"\uff1c15 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01% O2\",\"valueZh\":\"0.01% O2\"}],\"description\":{\"en\":\"4O2-GP is a SUSA electrochemical oxygen sensor with a measurement range of 0 to 25% O2, an output signal or sensitivity of 100\u00b120\u03bcA in air, a response time of \uff1c15 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4:0 to 25% O2\uff1b\u8f93\u51fa\u4fe1\u53f7:100\u00b120\u03bcA in air\uff1b\u54cd\u5e94\u65f6\u95f4 :\uff1c15 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4o2-gp-6350258-3c21c2c77789.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4o2-gp-6350258-6d7873a3be11.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4tht-ls-6350254\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4THT-LS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u5668\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50 mg\/m3\",\"sensitivity\":\"140\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"140\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.3 mg\/m3\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 50 mg\/m3\",\"valueZh\":\"0 - 50 mg\/m3\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"140\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"140\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.3 mg\/m3\",\"valueZh\":\"0.3 mg\/m3\"}],\"description\":{\"en\":\"4THT-LS is a SUSA electrochemical tetrahydrothiophene sensor with a measurement range of 0 - 50 mg\/m3, an output signal or sensitivity of 140\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 50 mg\/m3\uff1b\u7075\u654f\u5ea6\uff1a140\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4tht-ls-6350254-6600d67c394e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4tht-ls-6350254-28266da28ecb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4h2-nt-6350246\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4H2-NT\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000ppm\",\"sensitivity\":\"20\u00b110 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"20\u00b110 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<70 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"10 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 1000ppm\",\"valueZh\":\"0 - 1000ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"20\u00b110 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"20\u00b110 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<70 s\",\"valueZh\":\"<70 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\",\"valueZh\":\"10 ppm\"}],\"description\":{\"en\":\"4H2-NT is a SUSA electrochemical hydrogen sensor with a measurement range of 0 - 1000ppm, an output signal or sensitivity of 20\u00b110 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <70 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 1000ppm\uff1b\u7075\u654f\u5ea6\uff1a20\u00b110 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<70 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4h2-nt-6350246-e54f9faabde3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4h2-nt-6350246-a3ddecc6a5ff.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4co-qf-10256305\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CO-QF\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -10000 ppm\",\"sensitivity\":\"20\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"20\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"10 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -10000 ppm\",\"valueZh\":\"0 -10000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"20\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"20\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 30s\",\"valueZh\":\"< 30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"10 ppm\",\"valueZh\":\"10 ppm\"}],\"description\":{\"en\":\"4CO-QF is a SUSA electrochemical carbon monoxide sensor with a measurement range of 0 -10000 ppm, an output signal or sensitivity of 20\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 30s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -10000 ppm\uff1b\u7075\u654f\u5ea6\uff1a20\u00b1 10nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 30s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4co-qf-10256305-9cc2025abe53.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4co-qf-10256305-5256c7d687b1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4ch4s-ds-10256173\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CH4S-DS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -10 ppm\",\"sensitivity\":\"700\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"700\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 35s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -10 ppm\",\"valueZh\":\"0 -10 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"700\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"700\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 35s\",\"valueZh\":\"< 35s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4CH4S-DS is a SUSA electrochemical methanethiol sensor with a measurement range of 0 -10 ppm, an output signal or sensitivity of 700\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 35s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -10 ppm\uff1b\u7075\u654f\u5ea6\uff1a700\u00b1 150nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 35s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4ch4s-ds-10256173-8a4a88d6600d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4ch4s-ds-10256173-21ef0a90c524.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4co-sh-10256306\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CO-SH\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -2000 ppm\",\"sensitivity\":\"75\u00b1 15nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"75\u00b1 15nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"< 30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -2000 ppm\",\"valueZh\":\"0 -2000 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"75\u00b1 15nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"75\u00b1 15nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 30s\",\"valueZh\":\"< 30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4CO-SH is a SUSA electrochemical carbon monoxide sensor with a measurement range of 0 -2000 ppm, an output signal or sensitivity of 75\u00b1 15nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of < 30s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -2000 ppm\uff1b\u7075\u654f\u5ea6\uff1a75\u00b1 15nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 30s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4co-sh-10256306-2668a4bd0a2c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4co-sh-10256306-9d6c89ab4008.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4clo2-ls-10256174\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CLO2-LS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 -50 ppm\",\"sensitivity\":\"400\u00b1 180nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"400\u00b1 180nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"< 60s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.05 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 -50 ppm\",\"valueZh\":\"0 -50 ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"400\u00b1 180nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"400\u00b1 180nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 60s\",\"valueZh\":\"< 60s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.05 ppm\",\"valueZh\":\"0.05 ppm\"}],\"description\":{\"en\":\"4CLO2-LS is a SUSA electrochemical chlorine dioxide sensor with a measurement range of 0 -50 ppm, an output signal or sensitivity of 400\u00b1 180nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of < 60s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 -50 ppm\uff1b\u7075\u654f\u5ea6\uff1a400\u00b1 180nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a< 60s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4clo2-ls-10256174-c476a4fc07cd.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4clo2-ls-10256174-1b12f45e545c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4h2s-ns-6350257\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4H2S-NS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 1000ppm\",\"sensitivity\":\"90\u00b140 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"90\u00b140 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<45 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 to 50\u00b0 C\",\"temperatureZh\":\"-40 to 50\u00b0 C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 1000ppm\",\"valueZh\":\"0 - 1000ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"90\u00b140 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"90\u00b140 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<45 s\",\"valueZh\":\"<45 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4H2S-NS is a SUSA electrochemical hydrogen sulfide sensor with a measurement range of 0 - 1000ppm, an output signal or sensitivity of 90\u00b140 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <45 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 1000ppm\uff1b\u7075\u654f\u5ea6\uff1a90\u00b140 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<45 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4h2s-ns-6350257-5e355782f6a5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4h2s-ns-6350257-41b518b1be47.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4hcn-ls-6350251\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4HCN-LS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50ppm\",\"sensitivity\":\"100\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"100\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 50ppm\",\"valueZh\":\"0 - 50ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"100\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"100\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<120 s\",\"valueZh\":\"<120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.2 ppm\",\"valueZh\":\"0.2 ppm\"}],\"description\":{\"en\":\"4HCN-LS is a SUSA electrochemical hydrogen cyanide sensor with a measurement range of 0 - 50ppm, an output signal or sensitivity of 100\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <120 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 50ppm\uff1b\u7075\u654f\u5ea6\uff1a100\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<120 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4hcn-ls-6350251-67c21649fd37.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4hcn-ls-6350251-d58ad3268b40.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4cl2-ls-6350247\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CL2-LS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 50ppm\",\"sensitivity\":\"450\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"450\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 50ppm\",\"valueZh\":\"0 - 50ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"450\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"450\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4CL2-LS is a SUSA electrochemical chlorine sensor with a measurement range of 0 - 50ppm, an output signal or sensitivity of 450\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 50ppm\uff1b\u7075\u654f\u5ea6\uff1a450\u00b1150 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4cl2-ls-6350247-7be7c8477b42.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4cl2-ls-6350247-c389f42d9521.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4cl2-ds-6350248\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4CL2-DS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10ppm\",\"sensitivity\":\"750\u00b1200 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"750\u00b1200 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 10ppm\",\"valueZh\":\"0 - 10ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"750\u00b1200 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"750\u00b1200 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4CL2-DS is a SUSA electrochemical chlorine sensor with a measurement range of 0 - 10ppm, an output signal or sensitivity of 750\u00b1200 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 10ppm\uff1b\u7075\u654f\u5ea6\uff1a750\u00b1200 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4cl2-ds-6350248-6f4e22935c5c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4cl2-ds-6350248-9bb229645d81.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4eto-as-6350255\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4ETO-AS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100ppm\",\"sensitivity\":\"250\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"250\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 100ppm\",\"valueZh\":\"0 - 100ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"250\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"250\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<120 s\",\"valueZh\":\"<120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4ETO-AS is a SUSA electrochemical ethylene oxide sensor with a measurement range of 0 - 100ppm, an output signal or sensitivity of 250\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <120 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 100ppm\uff1b\u7075\u654f\u5ea6\uff1a250\u00b1100 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<120 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4eto-as-6350255-f61d2ca66f23.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4eto-as-6350255-81d05ddb02c6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4eto-ds-6350315\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4ETO-DS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 10ppm\",\"sensitivity\":\"1900\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"1900\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 10ppm\",\"valueZh\":\"0 - 10ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1900\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"1900\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<120 s\",\"valueZh\":\"<120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4ETO-DS is a SUSA electrochemical ethylene oxide sensor with a measurement range of 0 - 10ppm, an output signal or sensitivity of 1900\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <120 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 10ppm\uff1b\u7075\u654f\u5ea6\uff1a1900\u00b1500 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<120 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4eto-ds-6350315-c509119d23c8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4eto-ds-6350315-59745c123cfe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4eto-ss-6350259\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4ETO-SS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500ppm\",\"sensitivity\":\"100\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"100\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<120 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"5 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 500ppm\",\"valueZh\":\"0 - 500ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"100\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"100\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<120 s\",\"valueZh\":\"<120 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppm\",\"valueZh\":\"5 ppm\"}],\"description\":{\"en\":\"4ETO-SS is a SUSA electrochemical ethylene oxide sensor with a measurement range of 0 - 500ppm, an output signal or sensitivity of 100\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <120 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 500ppm\uff1b\u7075\u654f\u5ea6\uff1a100\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<120 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4eto-ss-6350259-0a132403f83d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4eto-ss-6350259-e79a068242c8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4nh3-as-6350313\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4NH3-AS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100ppm\",\"sensitivity\":\"150\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"150\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<90 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 100ppm\",\"valueZh\":\"0 - 100ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"150\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<90 s\",\"valueZh\":\"<90 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\",\"valueZh\":\"0.5 ppm\"}],\"description\":{\"en\":\"4NH3-AS is a SUSA electrochemical ammonia sensor with a measurement range of 0 - 100ppm, an output signal or sensitivity of 150\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <90 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 100ppm\uff1b\u7075\u654f\u5ea6\uff1a150\u00b150 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<90 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4nh3-as-6350313-2e51bd6b3012.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4nh3-as-6350313-248716ae36bb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4nh3-ss-6350261\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4NH3-SS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 500ppm\",\"sensitivity\":\"80\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"80\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<90 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 500ppm\",\"valueZh\":\"0 - 500ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"80\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"80\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<90 s\",\"valueZh\":\"<90 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"4NH3-SS is a SUSA electrochemical ammonia sensor with a measurement range of 0 - 500ppm, an output signal or sensitivity of 80\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <90 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 500ppm\uff1b\u7075\u654f\u5ea6\uff1a80\u00b120 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<90 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4nh3-ss-6350261-49643b3adace.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4nh3-ss-6350261-b58d0d6c0247.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4o3-cs-6350290\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4O3-CS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 20ppm\",\"sensitivity\":\"1500\u00b1500 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"1500\u00b1500 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 20ppm\",\"valueZh\":\"0 - 20ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1500\u00b1500 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"1500\u00b1500 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1 ppm\",\"valueZh\":\"0.1 ppm\"}],\"description\":{\"en\":\"4O3-CS is a SUSA electrochemical ozone sensor with a measurement range of 0 - 20ppm, an output signal or sensitivity of 1500\u00b1500 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 20ppm\uff1b\u7075\u654f\u5ea6\uff1a1500\u00b1500 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4o3-cs-6350290-4d4f0f5e1e1c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4o3-cs-6350290-2706ab208e86.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4o3-as-6350289\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4O3-AS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 100ppm\",\"sensitivity\":\"500\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"500\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"<60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.2 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 100ppm\",\"valueZh\":\"0 - 100ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"500\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"500\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<60 s\",\"valueZh\":\"<60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.2 ppm\",\"valueZh\":\"0.2 ppm\"}],\"description\":{\"en\":\"4O3-AS is a SUSA electrochemical ozone sensor with a measurement range of 0 - 100ppm, an output signal or sensitivity of 500\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of <60 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 100ppm\uff1b\u7075\u654f\u5ea6\uff1a500\u00b1100 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<60 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4o3-as-6350289-7be96f24781d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4o3-as-6350289-8b3f84b7e333.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4no-hs-6350253\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4NO-HS\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 250ppm\",\"sensitivity\":\"400\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"signal\":\"400\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5 ppm\",\"temperature\":\"-20 to 50\u00b0C\",\"temperatureZh\":\"-20 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 250ppm\",\"valueZh\":\"0 - 250ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"400\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\",\"valueZh\":\"400\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\",\"valueZh\":\"<30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5 ppm\",\"valueZh\":\"0.5 ppm\"}],\"description\":{\"en\":\"4NO-HS is a SUSA electrochemical nitric oxide sensor with a measurement range of 0 - 250ppm, an output signal or sensitivity of 400\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09, a response time of <30 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 250ppm\uff1b\u7075\u654f\u5ea6\uff1a400\u00b180 nA\/ppm\uff08\u6b63\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<30 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4no-hs-6350253-fa30b41d9d97.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4no-hs-6350253-437c38680880.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4no2-kt-6350249\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4NO2-KT\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:electrochemical\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0 - 2000ppm\",\"sensitivity\":\"20\u00b110 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"signal\":\"20\u00b110 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"responseTime\":\"<30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1 ppm\",\"temperature\":\"-40 to 50\u00b0C\",\"temperatureZh\":\"-40 to 50\u00b0C\",\"humidity\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"humidityZh\":\"15%-90% RH\uff08\u65e0\u51b7\u51dd\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 24 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 2000ppm\",\"valueZh\":\"0 - 2000ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"20\u00b110 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\",\"valueZh\":\"20\u00b110 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30 s\",\"valueZh\":\"<30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1 ppm\",\"valueZh\":\"1 ppm\"}],\"description\":{\"en\":\"4NO2-KT is a SUSA electrochemical nitrogen dioxide sensor with a measurement range of 0 - 2000ppm, an output signal or sensitivity of 20\u00b110 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09, a response time of <30 s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 2000ppm\uff1b\u7075\u654f\u5ea6\uff1a20\u00b110 nA\/ppm\uff08\u8d1f\u4fe1\u53f7\uff09\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<30 s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4no2-kt-6350249-98dae0321ac8.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4no2-kt-6350249-db41f218db4a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-20-3-3v-plus-6350374\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-20\/3.3V-plus\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201320 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e75mV\/ppm; output 2.0\u00b10.5V\",\"signal\":\"\uff1e75mV\/ppm; output 2.0\u00b10.5V\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"5 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u201320 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e75mV\/ppm; output 2.0\u00b10.5V\",\"valueZh\":\"\uff1e75mV\/ppm; output 2.0\u00b10.5V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 5 s\",\"valueZh\":\"T90 \u2264 5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppb\",\"valueZh\":\"5 ppb\"}],\"description\":{\"en\":\"4PID-20\/3.3V-plus is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u201320 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e75mV\/ppm; output 2.0\u00b10.5V, a response time of T90 \u2264 5 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:2.0\u00b10.5V\uff1b\u5de5\u4f5c\u7535\u538b:3.3\u00b10.1V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e75mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-20-3-3v-plus-6350374-0b909de93955.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-20-3-3v-plus-6350374-6f7683e4b08f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-100-3-3v-plus-6350318\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-100\/3.3V-plus\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u2013100 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e15mV\/ppm; output 2.0\u00b10.5V\",\"signal\":\"\uff1e15mV\/ppm; output 2.0\u00b10.5V\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"25 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u2013100 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e15mV\/ppm; output 2.0\u00b10.5V\",\"valueZh\":\"\uff1e15mV\/ppm; output 2.0\u00b10.5V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 5 s\",\"valueZh\":\"T90 \u2264 5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"25 ppb\",\"valueZh\":\"25 ppb\"}],\"description\":{\"en\":\"4PID-100\/3.3V-plus is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u2013100 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e15mV\/ppm; output 2.0\u00b10.5V, a response time of T90 \u2264 5 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:2.0\u00b10.5V\uff1b\u5de5\u4f5c\u7535\u538b:3.3\u00b10.1V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e15mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-100-3-3v-plus-6350318-a76c07df5b05.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-100-3-3v-plus-6350318-6f7683e4b08f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-300-3-3v-plus-6350369\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-300\/3.3V-plus\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u2013300 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e5mV\/ppm; output 2.0\u00b10.5V\",\"signal\":\"\uff1e5mV\/ppm; output 2.0\u00b10.5V\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"75 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013300 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u2013300 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e5mV\/ppm; output 2.0\u00b10.5V\",\"valueZh\":\"\uff1e5mV\/ppm; output 2.0\u00b10.5V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 5 s\",\"valueZh\":\"T90 \u2264 5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"75 ppb\",\"valueZh\":\"75 ppb\"}],\"description\":{\"en\":\"4PID-300\/3.3V-plus is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u2013300 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e5mV\/ppm; output 2.0\u00b10.5V, a response time of T90 \u2264 5 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:2.0\u00b10.5V\uff1b\u5de5\u4f5c\u7535\u538b:3.3\u00b10.1V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e5mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-300-3-3v-plus-6350369-b02ee3c18609.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-300-3-3v-plus-6350369-6f7683e4b08f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-1000-3-3v-plus-6350332\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-1000\/3.3V-plus\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u20131000 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e1.5mV\/ppm; output 2.0\u00b10.5V\",\"signal\":\"\uff1e1.5mV\/ppm; output 2.0\u00b10.5V\",\"responseTime\":\"T90 \u2264 3 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"250 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u20131000 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e1.5mV\/ppm; output 2.0\u00b10.5V\",\"valueZh\":\"\uff1e1.5mV\/ppm; output 2.0\u00b10.5V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 3 s\",\"valueZh\":\"T90 \u2264 3 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"250 ppb\",\"valueZh\":\"250 ppb\"}],\"description\":{\"en\":\"4PID-1000\/3.3V-plus is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u20131000 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e1.5mV\/ppm; output 2.0\u00b10.5V, a response time of T90 \u2264 3 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:2.0\u00b10.5V\uff1b\u5de5\u4f5c\u7535\u538b:3.3\u00b10.1V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e1.5mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-1000-3-3v-plus-6350332-3e6c8438b2b2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-1000-3-3v-plus-6350332-6f7683e4b08f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-2000-3-3v-plus-6350368\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-2000\/3.3V-plus\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u20132000 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e0.3mV\/ppm; output 2.0\u00b10.5V\",\"signal\":\"\uff1e0.3mV\/ppm; output 2.0\u00b10.5V\",\"responseTime\":\"T90 \u2264 3 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"500 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u20132000 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e0.3mV\/ppm; output 2.0\u00b10.5V\",\"valueZh\":\"\uff1e0.3mV\/ppm; output 2.0\u00b10.5V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 3 s\",\"valueZh\":\"T90 \u2264 3 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"500 ppb\",\"valueZh\":\"500 ppb\"}],\"description\":{\"en\":\"4PID-2000\/3.3V-plus is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u20132000 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e0.3mV\/ppm; output 2.0\u00b10.5V, a response time of T90 \u2264 3 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:2.0\u00b10.5V\uff1b\u5de5\u4f5c\u7535\u538b:3.3\u00b10.1V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e0.3mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-2000-3-3v-plus-6350368-c0936d174721.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-2000-3-3v-plus-6350368-6f7683e4b08f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-10000-3-3v-plus-6350366\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-10000\/3.3V-plus\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201310000 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e0.15mV\/ppm; output 2.0\u00b10.5V\",\"signal\":\"\uff1e0.15mV\/ppm; output 2.0\u00b10.5V\",\"responseTime\":\"T90 \u2264 3 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"2 ppm\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310000 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u201310000 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e0.15mV\/ppm; output 2.0\u00b10.5V\",\"valueZh\":\"\uff1e0.15mV\/ppm; output 2.0\u00b10.5V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 3 s\",\"valueZh\":\"T90 \u2264 3 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppm\",\"valueZh\":\"2 ppm\"}],\"description\":{\"en\":\"4PID-10000\/3.3V-plus is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u201310000 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e0.15mV\/ppm; output 2.0\u00b10.5V, a response time of T90 \u2264 3 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:2.0\u00b10.5V\uff1b\u5de5\u4f5c\u7535\u538b:3.3\u00b10.1V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e0.15mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-10000-3-3v-plus-6350366-8e0b8a2e3af1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-10000-3-3v-plus-6350366-6f7683e4b08f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-20-6350364\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-20\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201320 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e75mV\/ppm; output 1.8-3V\",\"signal\":\"\uff1e75mV\/ppm; output 1.8-3V\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"5 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201320 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u201320 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e75mV\/ppm; output 1.8-3V\",\"valueZh\":\"\uff1e75mV\/ppm; output 1.8-3V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 5 s\",\"valueZh\":\"T90 \u2264 5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"5 ppb\",\"valueZh\":\"5 ppb\"}],\"description\":{\"en\":\"4PID-20 is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u201320 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e75mV\/ppm; output 1.8-3V, a response time of T90 \u2264 5 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:1.8-3V\uff1b\u5de5\u4f5c\u7535\u538b:3.2-5V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e75mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-20-6350364-e4e5a5cacaa6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-20-6350364-b7651220cb07.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-100-6350362\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u2013100 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e15mV\/ppm; output 1.8-3V\",\"signal\":\"\uff1e15mV\/ppm; output 1.8-3V\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"25 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013100 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u2013100 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e15mV\/ppm; output 1.8-3V\",\"valueZh\":\"\uff1e15mV\/ppm; output 1.8-3V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 5 s\",\"valueZh\":\"T90 \u2264 5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"25 ppb\",\"valueZh\":\"25 ppb\"}],\"description\":{\"en\":\"4PID-100 is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u2013100 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e15mV\/ppm; output 1.8-3V, a response time of T90 \u2264 5 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:1.8-3V\uff1b\u5de5\u4f5c\u7535\u538b:3.2-5V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e15mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-100-6350362-bde1d0110ef9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-100-6350362-b7651220cb07.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-300-6350359\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-300\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u2013300 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e5mV\/ppm; output 1.8-3V\",\"signal\":\"\uff1e5mV\/ppm; output 1.8-3V\",\"responseTime\":\"T90 \u2264 5 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"75 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u2013300 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u2013300 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e5mV\/ppm; output 1.8-3V\",\"valueZh\":\"\uff1e5mV\/ppm; output 1.8-3V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 5 s\",\"valueZh\":\"T90 \u2264 5 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"75 ppb\",\"valueZh\":\"75 ppb\"}],\"description\":{\"en\":\"4PID-300 is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u2013300 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e5mV\/ppm; output 1.8-3V, a response time of T90 \u2264 5 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:1.8-3V\uff1b\u5de5\u4f5c\u7535\u538b:3.2-5V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e5mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-300-6350359-f6c418bc5e7b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-300-6350359-b7651220cb07.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-1000-6350357\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-1000\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u20131000 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e1.5mV\/ppm; output 1.8-3V\",\"signal\":\"\uff1e1.5mV\/ppm; output 1.8-3V\",\"responseTime\":\"T90 \u2264 3 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"250 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20131000 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u20131000 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e1.5mV\/ppm; output 1.8-3V\",\"valueZh\":\"\uff1e1.5mV\/ppm; output 1.8-3V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 3 s\",\"valueZh\":\"T90 \u2264 3 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"250 ppb\",\"valueZh\":\"250 ppb\"}],\"description\":{\"en\":\"4PID-1000 is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u20131000 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e1.5mV\/ppm; output 1.8-3V, a response time of T90 \u2264 3 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:1.8-3V\uff1b\u5de5\u4f5c\u7535\u538b:3.2-5V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e1.5mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-1000-6350357-103b52effe2e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-1000-6350357-b7651220cb07.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-2000-6350356\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-2000\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u20132000 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e0.3mV\/ppm; output 1.8-3V\",\"signal\":\"\uff1e0.3mV\/ppm; output 1.8-3V\",\"responseTime\":\"T90 \u2264 3 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"500 ppb\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u20132000 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u20132000 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e0.3mV\/ppm; output 1.8-3V\",\"valueZh\":\"\uff1e0.3mV\/ppm; output 1.8-3V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 3 s\",\"valueZh\":\"T90 \u2264 3 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"500 ppb\",\"valueZh\":\"500 ppb\"}],\"description\":{\"en\":\"4PID-2000 is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u20132000 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e0.3mV\/ppm; output 1.8-3V, a response time of T90 \u2264 3 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:1.8-3V\uff1b\u5de5\u4f5c\u7535\u538b:3.2-5V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e0.3mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-2000-6350356-fd04eb468190.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-2000-6350356-b7651220cb07.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4pid-10000-6350333\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4PID-10000\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:pid-photoionization\",\"series\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"PID\",\"techName\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"},\"specs\":{\"range\":\"0\u201310000 ppm (isobutylene equivalent)\",\"sensitivity\":\"\uff1e0.15mV\/ppm; output 1.8-3V\",\"signal\":\"\uff1e0.15mV\/ppm; output 1.8-3V\",\"responseTime\":\"T90 \u2264 3 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"2 ppm\",\"temperature\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"temperatureZh\":\"\u8303\u56f4 -40 to 50\u00b0 C\",\"humidity\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"humidityZh\":\"\u8303\u56f4 0-99% RH\uff08\u65e0\u51dd\u9732\uff09\",\"lifetime\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\",\"lifetimeZh\":\"\u4e0d\u5c11\u4e8e 5 \u5e74\uff08\u4e0d\u542b\u7d2b\u5916\u706f\u53ca\u68c0\u6d4b\u5668\uff09\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0\u201310000 ppm (isobutylene equivalent)\",\"valueZh\":\"0\u201310000 ppm (isobutylene equivalent)\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e0.15mV\/ppm; output 1.8-3V\",\"valueZh\":\"\uff1e0.15mV\/ppm; output 1.8-3V\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90 \u2264 3 s\",\"valueZh\":\"T90 \u2264 3 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2 ppm\",\"valueZh\":\"2 ppm\"}],\"description\":{\"en\":\"4PID-10000 is a SUSA pid photoionization volatile organic compounds sensor with a measurement range of 0\u201310000 ppm (isobutylene equivalent), an output signal or sensitivity of \uff1e0.15mV\/ppm; output 1.8-3V, a response time of T90 \u2264 3 s.\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7:1.8-3V\uff1b\u5de5\u4f5c\u7535\u538b:3.2-5V\uff1b\u7075\u654f\u5ea6\uff1a\uff1e0.15mV\/ppm\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4pid-10000-6350333-e38363562a80.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4pid-10000-6350333-b7651220cb07.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:cat3v-10252071\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"Cat3V\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"\u2014\",\"sensitivity\":\"\u2014\",\"signal\":\"\u2014\",\"responseTime\":\"\u2014\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"Cat3V is a SUSA catalytic combustion combustible gas sensor.\",\"zh\":\"Cat3V \u662f SUSA\uff08\u82cf\u8428\uff09\u50ac\u5316\u71c3\u70e7\u53ef\u71c3\u6c14\u4f53\u4f20\u611f\u5668\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-cat3v-10252071-8baa9cc9238c.webp\",\"documents\":[],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"The manufacturer product page did not publish a PDF document for this model.\",\"zh\":\"\u539f\u5382\u4ea7\u54c1\u9875\u672a\u516c\u5f00\u8be5\u578b\u53f7\u7684 PDF \u8d44\u6599\u3002\"}},{\"id\":\"susa:cat2-5vn-180-10252053\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"Cat2.5VN-180\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-5%CH4\",\"sensitivity\":\"\uff1e15mV\/1%CH4\",\"signal\":\"\uff1e15mV\/1%CH4\",\"responseTime\":\"<10s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"-40 to 70 \u2103\",\"temperatureZh\":\"-40 to 70 \u2103\",\"humidity\":\"0-90 %RH\",\"humidityZh\":\"0-90 %RH\",\"lifetime\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\",\"lifetimeZh\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5%CH4\",\"valueZh\":\"0-5%CH4\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e15mV\/1%CH4\",\"valueZh\":\"\uff1e15mV\/1%CH4\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<10s\",\"valueZh\":\"<10s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"Cat2.5VN-180 is a SUSA catalytic combustion methane sensor with a measurement range of 0-5%CH4, an output signal or sensitivity of \uff1e15mV\/1%CH4, a response time of <10s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0-5%CH4\uff1b\u7075\u654f\u5ea6\uff1a\uff1e15mV\/1%CH4\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<10s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-cat2-5vn-180-10252053-84af65330add.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-cat2-5vn-180-10252053-867d6ed6c623.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:cat2-7vnm-200-10252052\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"Cat2.7VNM-200\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-5%CH4\",\"sensitivity\":\"\u226515mV\/1%CH4\",\"signal\":\"\u226515mV\/1%CH4\",\"responseTime\":\"<10s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"-20 to 55 \u2103\",\"temperatureZh\":\"-20 to 55 \u2103\",\"humidity\":\"0-90 %RH\",\"humidityZh\":\"0-90 %RH\",\"lifetime\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\",\"lifetimeZh\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5%CH4\",\"valueZh\":\"0-5%CH4\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u226515mV\/1%CH4\",\"valueZh\":\"\u226515mV\/1%CH4\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<10s\",\"valueZh\":\"<10s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"Cat2.7VNM-200 is a SUSA catalytic combustion methane sensor with a measurement range of 0-5%CH4, an output signal or sensitivity of \u226515mV\/1%CH4, a response time of <10s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0-5%CH4\uff1b\u7075\u654f\u5ea6\uff1a\u226515mV\/1%CH4\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<10s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-cat2-7vnm-200-10252052-37dd913793e2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-cat2-7vnm-200-10252052-3be5f29c0461.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:mjc42-9-0-2j-b-10252018\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"MJC42.9\u00b10.2J(B)\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-4%CH4\",\"sensitivity\":\"\uff1e14mV\/1%CH4\",\"signal\":\"\uff1e14mV\/1%CH4\",\"responseTime\":\"<10s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"-20 to 55 \u2103\",\"temperatureZh\":\"-20 to 55 \u2103\",\"humidity\":\"0-95 %RH\",\"humidityZh\":\"0-95 %RH\",\"lifetime\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\",\"lifetimeZh\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-4%CH4\",\"valueZh\":\"0-4%CH4\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e14mV\/1%CH4\",\"valueZh\":\"\uff1e14mV\/1%CH4\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<10s\",\"valueZh\":\"<10s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"MJC42.9\u00b10.2J(B) is a SUSA catalytic combustion methane sensor with a measurement range of 0-4%CH4, an output signal or sensitivity of \uff1e14mV\/1%CH4, a response time of <10s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0-4%CH4\uff1b\u7075\u654f\u5ea6\uff1a\uff1e14mV\/1%CH4\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<10s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-mjc42-9-0-2j-b-10252018-78f7c5babfe5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-mjc42-9-0-2j-b-10252018-5db72f1919d9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:mjc42-8ln-090-10252013\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"MJC42.8LN-090\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-5%CH4\",\"sensitivity\":\">20mV\/1%CH4\",\"signal\":\">20mV\/1%CH4\",\"responseTime\":\"<15s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"-20 to 55 \u2103\",\"temperatureZh\":\"-20 to 55 \u2103\",\"humidity\":\"0-90 %RH\",\"humidityZh\":\"0-90 %RH\",\"lifetime\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\",\"lifetimeZh\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5%CH4\",\"valueZh\":\"0-5%CH4\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\">20mV\/1%CH4\",\"valueZh\":\">20mV\/1%CH4\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<15s\",\"valueZh\":\"<15s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"MJC42.8LN-090 is a SUSA catalytic combustion methane sensor with a measurement range of 0-5%CH4, an output signal or sensitivity of >20mV\/1%CH4, a response time of <15s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0-5%CH4\uff1b\u7075\u654f\u5ea6\uff1a>20mV\/1%CH4\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<15s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-mjc42-8ln-090-10252013-8033938db963.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-mjc42-8ln-090-10252013-1d53481080f0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:nap25-10251995\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"NAP25\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-5%CH4\",\"sensitivity\":\"\u226512mV\/1%CH4\",\"signal\":\"\u226512mV\/1%CH4\",\"responseTime\":\"<10s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"-40 to 70 \u2103\",\"temperatureZh\":\"-40 to 70 \u2103\",\"humidity\":\"0-90 %RH\",\"humidityZh\":\"0-90 %RH\",\"lifetime\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\",\"lifetimeZh\":\"\u25cf\u7528\u4e8e\u53ef\u71c3\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5%CH4\",\"valueZh\":\"0-5%CH4\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u226512mV\/1%CH4\",\"valueZh\":\"\u226512mV\/1%CH4\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<10s\",\"valueZh\":\"<10s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"NAP25 is a SUSA catalytic combustion methane sensor with a measurement range of 0-5%CH4, an output signal or sensitivity of \u226512mV\/1%CH4, a response time of <10s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0-5%CH4\uff1b\u7075\u654f\u5ea6\uff1a\u226512mV\/1%CH4\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<10s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-nap25-10251995-bc8ea7396a42.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-nap25-10251995-9fcf2ab3fcc3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:cat23ch-10251993\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"Cat23CH\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-2.5%C2H2\",\"sensitivity\":\"\u226512mV\/1% C2H2\",\"signal\":\"\u226512mV\/1% C2H2\",\"responseTime\":\"\uff1c10s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"-40 to 70 \u2103\",\"temperatureZh\":\"-40 to 70 \u2103\",\"humidity\":\"0-90 %RH\",\"humidityZh\":\"0-90 %RH\",\"lifetime\":\"\u25cf\u7528\u4e8e\u4e59\u7094\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\",\"lifetimeZh\":\"\u25cf\u7528\u4e8e\u4e59\u7094\u6c14\u4f53\u6d53\u5ea6\u68c0\u6d4b\u4eea\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-2.5%C2H2\",\"valueZh\":\"0-2.5%C2H2\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\u226512mV\/1% C2H2\",\"valueZh\":\"\u226512mV\/1% C2H2\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\uff1c10s\",\"valueZh\":\"\uff1c10s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"Cat23CH is a SUSA catalytic combustion acetylene sensor with a measurement range of 0-2.5%C2H2, an output signal or sensitivity of \u226512mV\/1% C2H2, a response time of \uff1c10s.\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0-2.5%C2H2\uff1b\u7075\u654f\u5ea6\uff1a\u226512mV\/1% C2H2\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a\uff1c10s\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-cat23ch-10251993-90aac19eb503.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-cat23ch-10251993-09a4426162d8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"susa:4rcat3-10251989\",\"brandKey\":\"susa\",\"brandName\":\"SUSA\",\"model\":\"4RCAT3\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"susa:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"},\"gas\":\"LEL_CH4\",\"gasName\":{\"en\":\"LEL\/Methane (LEL\/CH4)\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53 \/ \u7532\u70f7\uff08LEL\uff09\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0 - 100%LEL\",\"sensitivity\":\"\uff1e15mV\/%CH4\",\"signal\":\"\uff1e15mV\/%CH4\",\"responseTime\":\"<20s ( CH4)\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u2014\",\"temperature\":\"-20\uff5e50\u2103\",\"temperatureZh\":\"-20\uff5e50\u2103\",\"humidity\":\"\uff1c98%\uff0825\u2103\uff09\",\"humidityZh\":\"\uff1c98%\uff0825\u2103\uff09\",\"lifetime\":\"\u5728\u7a7a\u6c14\u4e2d 36 \u4e2a\u6708\",\"lifetimeZh\":\"\u5728\u7a7a\u6c14\u4e2d 36 \u4e2a\u6708\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0 - 100%LEL\",\"valueZh\":\"0 - 100%LEL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"\uff1e15mV\/%CH4\",\"valueZh\":\"\uff1e15mV\/%CH4\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<20s ( CH4)\",\"valueZh\":\"<20s ( CH4)\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u2014\",\"valueZh\":\"\u2014\"}],\"description\":{\"en\":\"4RCAT3 is a SUSA catalytic combustion lel\/methane (lel\/ch4) sensor with a measurement range of 0 - 100%LEL, an output signal or sensitivity of \uff1e15mV\/%CH4, a response time of <20s ( CH4).\",\"zh\":\"\u68c0\u6d4b\u8303\u56f4\uff1a0 - 100%LEL\uff1b\u7075\u654f\u5ea6\uff1a\uff1e15mV\/%CH4\uff1b\u54cd\u5e94\u65f6\u95f4\uff1a<20s ( CH4)\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/images\/susa-4rcat3-10251989-f1be939b541d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/susa\/documents\/susa-4rcat3-10251989-dc43f7c9ac9a.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4nh3-24\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4NH3\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5 \/ 0-200 \/ 0-500\",\"sensitivity\":\"0.14\u00b10.05 uA \/ ppm\",\"signal\":\"0.14\u00b10.05 uA \/ ppm\",\"signalZh\":\"0.14\u00b10.05 uA \/ ppm\",\"responseTime\":\"\u226460\u79d2\",\"responseTimeZh\":\"\u226460\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5ppm\",\"resolutionZh\":\"0.5ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5 \/ 0-200 \/ 0-500\",\"valueZh\":\"0-5 \/ 0-200 \/ 0-500\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.14\u00b10.05 uA \/ ppm\",\"valueZh\":\"0.14\u00b10.05 uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226460\u79d2\",\"valueZh\":\"\u226460\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5ppm\",\"valueZh\":\"0.5ppm\"}],\"description\":{\"en\":\"HH-4NH3 is an HH electrochemical gas sensor for ammonia, with range 0-5 \/ 0-200 \/ 0-500, output\/sensitivity 0.14\u00b10.05 uA \/ ppm, response time \u226460\u79d2.\",\"zh\":\"HH-4NH3 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4nh3-a338b37571fc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4nh3-1000-7023a5782b41.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4nh3-100-14c2d2751801.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4nh3-2000-e71267260cef.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4nh3-20-5cfe02d05ed6.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4nh3-5-daeaafcde365.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4nh3-5000-f9f7dca332b8.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4nh3-500-dc2fd5ddc626.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4o3-25\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4O3-\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"0.60\u00b10.20uA \/ ppm\",\"signal\":\"0.60\u00b10.20uA \/ ppm\",\"signalZh\":\"0.60\u00b10.20uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.02ppm\",\"resolutionZh\":\"0.02ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.60\u00b10.20uA \/ ppm\",\"valueZh\":\"0.60\u00b10.20uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.02ppm\",\"valueZh\":\"0.02ppm\"}],\"description\":{\"en\":\"HH-4O3- is an HH electrochemical gas sensor for ozone, with range 0-10 \/ 0-100, output\/sensitivity 0.60\u00b10.20uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4O3- \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o3-0141cfbfabad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o3-1000-2978e51ce722.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o3-100-1b32bc090f13.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o3-10-711f3bc3331b.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o3-1-8ffe28ec79dc.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o3-2000-d36dcd9efce7.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o3-5000-1d1297a36e34.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4no2-26\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4NO2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100\",\"sensitivity\":\"0.70\u00b10.40uA \/ ppm\",\"signal\":\"0.70\u00b10.40uA \/ ppm\",\"signalZh\":\"0.70\u00b10.40uA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100\",\"valueZh\":\"0-20 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.70\u00b10.40uA \/ ppm\",\"valueZh\":\"0.70\u00b10.40uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4NO2 is an HH electrochemical gas sensor for nitrogen dioxide, with range 0-20 \/ 0-100, output\/sensitivity 0.70\u00b10.40uA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4NO2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o3-0141cfbfabad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4no2-2000-5b4996ce29d7.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4no2-20-ce19fb1f138e.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4no2-5-80d007abfc30.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4so2-27\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4SO2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.6\u00b10.2uA \/ ppm\",\"signal\":\"0.6\u00b10.2uA \/ ppm\",\"signalZh\":\"0.6\u00b10.2uA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.6\u00b10.2uA \/ ppm\",\"valueZh\":\"0.6\u00b10.2uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4SO2 is an HH electrochemical gas sensor for sulfur dioxide, with range 0-100, output\/sensitivity 0.6\u00b10.2uA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4SO2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4nh3-a338b37571fc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4so2-100-063555c7ba13.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4so2-2000-1cd26f0814f9.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4so2-20-75b895e2f7d9.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4so2-5000-94ed41f709c6.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4so2-5-f46752a5a493.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4ch2o-28\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4CH2O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"1.2\u00b10.7uA \/ ppm\",\"signal\":\"1.2\u00b10.7uA \/ ppm\",\"signalZh\":\"1.2\u00b10.7uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1.2\u00b10.7uA \/ ppm\",\"valueZh\":\"1.2\u00b10.7uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4CH2O is an HH electrochemical gas sensor for formaldehyde, with range 0-10 \/ 0-100, output\/sensitivity 1.2\u00b10.7uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4CH2O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch2o-35b8936498a2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcho-10-166286149878.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcho-50-0f47d6e8aaa4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4ph3-29\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4PH3\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-2000\",\"sensitivity\":\"1.5\u00b10.3uA \/ ppm\",\"signal\":\"1.5\u00b10.3uA \/ ppm\",\"signalZh\":\"1.5\u00b10.3uA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-2000\",\"valueZh\":\"0-20 \/ 0-2000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1.5\u00b10.3uA \/ ppm\",\"valueZh\":\"1.5\u00b10.3uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4PH3 is an HH electrochemical gas sensor for phosphine, with range 0-20 \/ 0-2000, output\/sensitivity 1.5\u00b10.3uA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4PH3 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4nh3-a338b37571fc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4ph3-1000-a5fdd8eddbdb.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4ph3-2000-b87bc2590590.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4ph3-20-e4f7c6974f5d.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4ph3-5-c13eb0873c06.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4h2s-30\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4H2S\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.7\u00b10.30 \u00b5A \/ ppm\",\"signal\":\"0.7\u00b10.30 \u00b5A \/ ppm\",\"signalZh\":\"0.7\u00b10.30 \u00b5A \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.7\u00b10.30 \u00b5A \/ ppm\",\"valueZh\":\"0.7\u00b10.30 \u00b5A \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4H2S is an HH electrochemical gas sensor for hydrogen sulfide, with range 0-100, output\/sensitivity 0.7\u00b10.30 \u00b5A \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4H2S \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4h2s-5e18218a033b.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-1000-7a2187db5dee.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-100-64cc234681f9.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-10-9f9f469cfdfe.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-200-db5cc0731ca9.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-2000-91c835f9743f.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-20-d892eaccf50b.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-2-48ca2999c1e5.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-5000-d7d877d79825.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-500-f48f428b9861.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2s-50-95e0cc57807e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4hf-31\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4HF\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"0.4\u00b10.2uA \/ ppm\",\"signal\":\"0.4\u00b10.2uA \/ ppm\",\"signalZh\":\"0.4\u00b10.2uA \/ ppm\",\"responseTime\":\"\u226490\u79d2\",\"responseTimeZh\":\"\u226490\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.4\u00b10.2uA \/ ppm\",\"valueZh\":\"0.4\u00b10.2uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226490\u79d2\",\"valueZh\":\"\u226490\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4HF is an HH electrochemical gas sensor for hydrogen fluoride, with range 0-10 \/ 0-100, output\/sensitivity 0.4\u00b10.2uA \/ ppm, response time \u226490\u79d2.\",\"zh\":\"HH-4HF \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c1f\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4hf-81d2d5519a35.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hf-100-2572bdd90b89.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hf-10-728c7ea860fd.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c12-32\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C12\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100\",\"sensitivity\":\"0.7\u00b10.45uA \/ ppm\",\"signal\":\"0.7\u00b10.45uA \/ ppm\",\"signalZh\":\"0.7\u00b10.45uA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100\",\"valueZh\":\"0-20 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.7\u00b10.45uA \/ ppm\",\"valueZh\":\"0.7\u00b10.45uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4C12 is an HH electrochemical gas sensor for chlorine, with range 0-20 \/ 0-100, output\/sensitivity 0.7\u00b10.45uA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4C12 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o3-0141cfbfabad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4cl2-1000-15b7b9baecff.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4cl2-10-f675e6181634.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4cl2-200-17672cbf5ca3.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4cl2-20-b4b44d047122.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4cl2-50-5029568eae81.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4h2-33\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4H2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2\",\"gasName\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1000 \/ 0-40000\",\"sensitivity\":\"0.030\u00b10.015uA \/ ppm\",\"signal\":\"0.030\u00b10.015uA \/ ppm\",\"signalZh\":\"0.030\u00b10.015uA \/ ppm\",\"responseTime\":\"\u226470\u79d2\",\"responseTimeZh\":\"\u226470\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-1000 \/ 0-40000\",\"valueZh\":\"0-1000 \/ 0-40000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.030\u00b10.015uA \/ ppm\",\"valueZh\":\"0.030\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226470\u79d2\",\"valueZh\":\"\u226470\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4H2 is an HH electrochemical gas sensor for hydrogen, with range 0-1000 \/ 0-40000, output\/sensitivity 0.030\u00b10.015uA \/ ppm, response time \u226470\u79d2.\",\"zh\":\"HH-4H2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c22\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4h2-def41d881c7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2-1000k-co-5cbe7e0c24a5.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2-1000-5c75ae746452.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2-2000k-co-a86745e3c3b9.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2-2000-d73341fd5424.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2-40000k-co-f3dc2dedb352.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2-40000-dedacb6b12b4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4hcn-34\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4HCN\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"0.80\u00b10.40uA \/ ppm\",\"signal\":\"0.80\u00b10.40uA \/ ppm\",\"signalZh\":\"0.80\u00b10.40uA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.80\u00b10.40uA \/ ppm\",\"valueZh\":\"0.80\u00b10.40uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4HCN is an HH electrochemical gas sensor for hydrogen cyanide, with range 0-10 \/ 0-100, output\/sensitivity 0.80\u00b10.40uA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4HCN \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4nh3-a338b37571fc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcn-10-9fa5166bcac7.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcn-50-00452f55b36b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4co-35\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4CO\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-50 \/ 0-500 \/ 0-1000 \/ 0-10000\",\"sensitivity\":\"0.060\u00b10.020uA \/ ppm\",\"signal\":\"0.060\u00b10.020uA \/ ppm\",\"signalZh\":\"0.060\u00b10.020uA \/ ppm\",\"responseTime\":\"\u226420\u79d2\",\"responseTimeZh\":\"\u226420\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-50 \/ 0-500 \/ 0-1000 \/ 0-10000\",\"valueZh\":\"0-50 \/ 0-500 \/ 0-1000 \/ 0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.060\u00b10.020uA \/ ppm\",\"valueZh\":\"0.060\u00b10.020uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226420\u79d2\",\"valueZh\":\"\u226420\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4CO is an HH electrochemical gas sensor for carbon monoxide, with range 0-50 \/ 0-500 \/ 0-1000 \/ 0-10000, output\/sensitivity 0.060\u00b10.020uA \/ ppm, response time \u226420\u79d2.\",\"zh\":\"HH-4CO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4h2-def41d881c7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-10000-65456e197124.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-1000-550f8552da37.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-100-425d79a544a3.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-20000-c542c664f402.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-2000-bcfbcf9f8a96.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-5000-b5693b4cb40d.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-500-4d0b4b7be21d.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4co-50-476f5700e2f5.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c1o2-36\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C1O2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CLO2\",\"gasName\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100\",\"sensitivity\":\"-0.40\u00b10.21\u03bcA \/ ppm\",\"signal\":\"-0.40\u00b10.21\u03bcA \/ ppm\",\"signalZh\":\"-0.40\u00b10.21\u03bcA \/ ppm\",\"responseTime\":\"\u226445\u79d2\",\"responseTimeZh\":\"\u226445\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.2ppm\",\"resolutionZh\":\"0.2ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100\",\"valueZh\":\"0-20 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"-0.40\u00b10.21\u03bcA \/ ppm\",\"valueZh\":\"-0.40\u00b10.21\u03bcA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226445\u79d2\",\"valueZh\":\"\u226445\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.2ppm\",\"valueZh\":\"0.2ppm\"}],\"description\":{\"en\":\"HH-4C1O2 is an HH electrochemical gas sensor for chlorine dioxide, with range 0-20 \/ 0-100, output\/sensitivity -0.40\u00b10.21\u03bcA \/ ppm, response time \u226445\u79d2.\",\"zh\":\"HH-4C1O2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2f\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o3-0141cfbfabad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4clo2-100-ef643c06efd9.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4clo2-10-0d6592d1060a.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4clo2-1-67a38c6b3afd.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4clo2-50-3ca2322b0c31.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4hcl-37\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4HCL\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100\",\"sensitivity\":\"0.80\u00b10.40uA \/ ppm\",\"signal\":\"0.80\u00b10.40uA \/ ppm\",\"signalZh\":\"0.80\u00b10.40uA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100\",\"valueZh\":\"0-20 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.80\u00b10.40uA \/ ppm\",\"valueZh\":\"0.80\u00b10.40uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4HCL is an HH electrochemical gas sensor for hydrogen chloride, with range 0-20 \/ 0-100, output\/sensitivity 0.80\u00b10.40uA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4HCL \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4hf-81d2d5519a35.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcl-100p-9b3d138f77eb.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcl-200p-b3089ff16c8e.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcl-20p-884eaacca31a.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcl-20-5b6918f73c81.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hcl-50p-4fa2cd3fa7a1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4h2o2-38\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4H2O2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1000\",\"sensitivity\":\"0.07\u00b10.03\u03bcA \/ ppm\",\"signal\":\"0.07\u00b10.03\u03bcA \/ ppm\",\"signalZh\":\"0.07\u00b10.03\u03bcA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5ppm\",\"resolutionZh\":\"0.5ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-1000\",\"valueZh\":\"0-1000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.07\u00b10.03\u03bcA \/ ppm\",\"valueZh\":\"0.07\u00b10.03\u03bcA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5ppm\",\"valueZh\":\"0.5ppm\"}],\"description\":{\"en\":\"HH-4H2O2 is an HH electrochemical gas sensor for hydrogen peroxide, with range 0-1000, output\/sensitivity 0.07\u00b10.03\u03bcA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4H2O2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4h2-def41d881c7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4h2o2-1000-2407ee7db41f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4tvoc-39\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4TVOC\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"1.2\u00b10.7uA \/ ppm\",\"signal\":\"1.2\u00b10.7uA \/ ppm\",\"signalZh\":\"1.2\u00b10.7uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1.2\u00b10.7uA \/ ppm\",\"valueZh\":\"1.2\u00b10.7uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4TVOC is an HH electrochemical gas sensor for volatile organic compounds, with range 0-10 \/ 0-100, output\/sensitivity 1.2\u00b10.7uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4TVOC \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4tvoc-da19f0b7e495.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4voc-10-ae19cbfc2e77.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4voc-100-08e8b65c7589.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4voc-1000-d82ee758b2f8.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4voc-10000-fef996ea221c.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4voc-2-ed1a816ac7e2.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4voc-200-044f7d60d6b4.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4voc-2000-d8280c6cbd60.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4ch3sh-40\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4CH3SH\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10\",\"sensitivity\":\"0.7\u00b10.20\u03bcA \/ ppm\",\"signal\":\"0.7\u00b10.20\u03bcA \/ ppm\",\"signalZh\":\"0.7\u00b10.20\u03bcA \/ ppm\",\"responseTime\":\"\u226460\u79d2\",\"responseTimeZh\":\"\u226460\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10\",\"valueZh\":\"0-10\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.7\u00b10.20\u03bcA \/ ppm\",\"valueZh\":\"0.7\u00b10.20\u03bcA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226460\u79d2\",\"valueZh\":\"\u226460\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4CH3SH is an HH electrochemical gas sensor for methanethiol, with range 0-10, output\/sensitivity 0.7\u00b10.20\u03bcA \/ ppm, response time \u226460\u79d2.\",\"zh\":\"HH-4CH3SH \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u786b\u9187\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4ch3sh-10-dba63d8cad43.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c6h6-41\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C6H6\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C6H6\",\"gasName\":{\"en\":\"Benzene\",\"zh\":\"\u82ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.20\u00b10.15uA \/ ppm\",\"signal\":\"0.20\u00b10.15uA \/ ppm\",\"signalZh\":\"0.20\u00b10.15uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.20\u00b10.15uA \/ ppm\",\"valueZh\":\"0.20\u00b10.15uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4C6H6 is an HH electrochemical gas sensor for benzene, with range 0-100, output\/sensitivity 0.20\u00b10.15uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4C6H6 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u82ef\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c6h6-100-770b2d40b2f4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c7h8-42\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C7H8\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C7H8\",\"gasName\":{\"en\":\"Toluene\",\"zh\":\"\u7532\u82ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-500\",\"sensitivity\":\"0.04\u00b10.02uA \/ ppm\",\"signal\":\"0.04\u00b10.02uA \/ ppm\",\"signalZh\":\"0.04\u00b10.02uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-500\",\"valueZh\":\"0-500\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.04\u00b10.02uA \/ ppm\",\"valueZh\":\"0.04\u00b10.02uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-4C7H8 is an HH electrochemical gas sensor for toluene, with range 0-500, output\/sensitivity 0.04\u00b10.02uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4C7H8 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u82ef\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c7h8-500-2bd4629e96b6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4ch2chcn-43\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4CH2CHCN\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C3H3N\",\"gasName\":{\"en\":\"Acrylonitrile\",\"zh\":\"\u4e19\u70ef\u8148\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"0.3\u00b10.10\u03bcA \/ ppm\",\"signal\":\"0.3\u00b10.10\u03bcA \/ ppm\",\"signalZh\":\"0.3\u00b10.10\u03bcA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5ppm\",\"resolutionZh\":\"0.5ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.3\u00b10.10\u03bcA \/ ppm\",\"valueZh\":\"0.3\u00b10.10\u03bcA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5ppm\",\"valueZh\":\"0.5ppm\"}],\"description\":{\"en\":\"HH-4CH2CHCN is an HH electrochemical gas sensor for acrylonitrile, with range 0-10 \/ 0-100, output\/sensitivity 0.3\u00b10.10\u03bcA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4CH2CHCN \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e19\u70ef\u8148\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c3h3n-100-b4945d2bb417.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c2h6s-44\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C2H6S\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H6S\",\"gasName\":{\"en\":\"Dimethyl Sulfide\",\"zh\":\"\u7532\u786b\u919a\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"1.7\u00b10.4uA \/ ppm\",\"signal\":\"1.7\u00b10.4uA \/ ppm\",\"signalZh\":\"1.7\u00b10.4uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1.7\u00b10.4uA \/ ppm\",\"valueZh\":\"1.7\u00b10.4uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4C2H6S is an HH electrochemical gas sensor for dimethyl sulfide, with range 0-10 \/ 0-100, output\/sensitivity 1.7\u00b10.4uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4C2H6S \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u786b\u919a\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c2h6s-100-ee56af5a80e0.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c2h2-45\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C2H2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H2\",\"gasName\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100 \/ 0-1000\",\"sensitivity\":\"1.7\u00b10.4uA \/ ppm\",\"signal\":\"1.7\u00b10.4uA \/ ppm\",\"signalZh\":\"1.7\u00b10.4uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100 \/ 0-1000\",\"valueZh\":\"0-10 \/ 0-100 \/ 0-1000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1.7\u00b10.4uA \/ ppm\",\"valueZh\":\"1.7\u00b10.4uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4C2H2 is an HH electrochemical gas sensor for acetylene, with range 0-10 \/ 0-100 \/ 0-1000, output\/sensitivity 1.7\u00b10.4uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4C2H2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u7094\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4h2-def41d881c7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c2h2-100-a48aa89133a9.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c2h4-46\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C2H4\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H4\",\"gasName\":{\"en\":\"Ethylene\",\"zh\":\"\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100 \/ 0-2000\",\"sensitivity\":\"1.7\u00b10.4uA \/ ppm\",\"signal\":\"1.7\u00b10.4uA \/ ppm\",\"signalZh\":\"1.7\u00b10.4uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100 \/ 0-2000\",\"valueZh\":\"0-20 \/ 0-100 \/ 0-2000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1.7\u00b10.4uA \/ ppm\",\"valueZh\":\"1.7\u00b10.4uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4C2H4 is an HH electrochemical gas sensor for ethylene, with range 0-20 \/ 0-100 \/ 0-2000, output\/sensitivity 1.7\u00b10.4uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4C2H4 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u70ef\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4h2-def41d881c7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c2h4-100-38a78ab54186.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c2h4-2000-21037a79446b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4sih4-47\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4SiH4\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"SIH4\",\"gasName\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100 \/ 0-1000\",\"sensitivity\":\"0.80\u00b10.40uA \/ ppm\",\"signal\":\"0.80\u00b10.40uA \/ ppm\",\"signalZh\":\"0.80\u00b10.40uA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100 \/ 0-1000\",\"valueZh\":\"0-10 \/ 0-100 \/ 0-1000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.80\u00b10.40uA \/ ppm\",\"valueZh\":\"0.80\u00b10.40uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4SiH4 is an HH electrochemical gas sensor for silane, with range 0-10 \/ 0-100 \/ 0-1000, output\/sensitivity 0.80\u00b10.40uA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4SiH4 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7845\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4nh3-a338b37571fc.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4sih4-1000-83ff84819e55.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4sih4-50-4a3ba242d298.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4sih4-10-0efaf18ab540.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4eto-48\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4ETO\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"1.7\u00b10.4uA \/ ppm\",\"signal\":\"1.7\u00b10.4uA \/ ppm\",\"signalZh\":\"1.7\u00b10.4uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1ppm\",\"resolutionZh\":\"0.1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"1.7\u00b10.4uA \/ ppm\",\"valueZh\":\"1.7\u00b10.4uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1ppm\",\"valueZh\":\"0.1ppm\"}],\"description\":{\"en\":\"HH-4ETO is an HH electrochemical gas sensor for ethylene oxide, with range 0-10 \/ 0-100, output\/sensitivity 1.7\u00b10.4uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4ETO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4eto-100-3c1729df2d23.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4eto-10-e54cbb55bc2b.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4eto-500-73ad33446b91.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4no-49\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4NO\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100 \/ 0-250 \/ 0-1000\",\"sensitivity\":\"0.40\u00b10.15\u03bcA \/ ppm\",\"signal\":\"0.40\u00b10.15\u03bcA \/ ppm\",\"signalZh\":\"0.40\u00b10.15\u03bcA \/ ppm\",\"responseTime\":\"\u226430\u79d2\",\"responseTimeZh\":\"\u226430\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5ppm\",\"resolutionZh\":\"0.5ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100 \/ 0-250 \/ 0-1000\",\"valueZh\":\"0-20 \/ 0-100 \/ 0-250 \/ 0-1000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.40\u00b10.15\u03bcA \/ ppm\",\"valueZh\":\"0.40\u00b10.15\u03bcA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226430\u79d2\",\"valueZh\":\"\u226430\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5ppm\",\"valueZh\":\"0.5ppm\"}],\"description\":{\"en\":\"HH-4NO is an HH electrochemical gas sensor for nitric oxide, with range 0-20 \/ 0-100 \/ 0-250 \/ 0-1000, output\/sensitivity 0.40\u00b10.15\u03bcA \/ ppm, response time \u226430\u79d2.\",\"zh\":\"HH-4NO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o3-0141cfbfabad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4no-100-d22004dcfe89.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4no-2000-e40ccbe264f3.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4no-250-60e07b6eb39d.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4no-5-dc0a243051c7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4c2h3cl-50\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4C2H3CL\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H3CL\",\"gasName\":{\"en\":\"Vinyl Chloride\",\"zh\":\"\u6c2f\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"2.0\u00b11.0uA \/ ppm\",\"signal\":\"2.0\u00b11.0uA \/ ppm\",\"signalZh\":\"2.0\u00b11.0uA \/ ppm\",\"responseTime\":\"\u226460\u79d2\",\"responseTimeZh\":\"\u226460\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5ppm\",\"resolutionZh\":\"0.5ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"2.0\u00b11.0uA \/ ppm\",\"valueZh\":\"2.0\u00b11.0uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226460\u79d2\",\"valueZh\":\"\u226460\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5ppm\",\"valueZh\":\"0.5ppm\"}],\"description\":{\"en\":\"HH-4C2H3CL is an HH electrochemical gas sensor for vinyl chloride, with range 0-10 \/ 0-100, output\/sensitivity 2.0\u00b11.0uA \/ ppm, response time \u226460\u79d2.\",\"zh\":\"HH-4C2H3CL \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u4e59\u70ef\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4h2-def41d881c7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c2h3cl-100-139e8a71fc43.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c2h3cl-20-ae11fcc9384f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4o2-30-vol-51\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4O2-30%VOL\u9ed1\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30%VOL\",\"sensitivity\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"signal\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"signalZh\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"responseTime\":\"\u226420\u79d2\",\"responseTimeZh\":\"\u226420\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u00b11%\",\"resolutionZh\":\"\u00b11%\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30%VOL\",\"valueZh\":\"0-30%VOL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"valueZh\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226420\u79d2\",\"valueZh\":\"\u226420\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u00b11%\",\"valueZh\":\"\u00b11%\"}],\"description\":{\"en\":\"HH-4O2-30%VOL\u9ed1 is an HH electrochemical gas sensor for oxygen, with range 0-30%VOL, output\/sensitivity 0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09, response time \u226420\u79d2.\",\"zh\":\"HH-4O2-30%VOL\u9ed1 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o2-30-vol-e6f0c98ca8ab.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o2-25-vol-bae51445f840.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4o2-30-vol-52\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4O2-30%VOL\u84dd\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30%VOL\",\"sensitivity\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"signal\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"signalZh\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"responseTime\":\"\u226420\u79d2\",\"responseTimeZh\":\"\u226420\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u00b11%\",\"resolutionZh\":\"\u00b11%\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30%VOL\",\"valueZh\":\"0-30%VOL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\",\"valueZh\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226420\u79d2\",\"valueZh\":\"\u226420\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u00b11%\",\"valueZh\":\"\u00b11%\"}],\"description\":{\"en\":\"HH-4O2-30%VOL\u84dd is an HH electrochemical gas sensor for oxygen, with range 0-30%VOL, output\/sensitivity 0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d\uff09, response time \u226420\u79d2.\",\"zh\":\"HH-4O2-30%VOL\u84dd \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o2-30-vol-79a8f94bd105.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o2-30-vol-4062febf9d4f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4o2lf-30-vol-53\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4O2LF-30%VOL\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Lead-Free Oxygen\",\"zh\":\"\u65e0\u94c5\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30%\",\"sensitivity\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d)\",\"signal\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d)\",\"signalZh\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d)\",\"responseTime\":\"\u226415\u79d2\",\"responseTimeZh\":\"\u226415\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1% VOl O2\",\"resolutionZh\":\"0.1% VOl O2\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30%\",\"valueZh\":\"0-30%\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d)\",\"valueZh\":\"0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d)\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u226415\u79d2\",\"valueZh\":\"\u226415\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1% VOl O2\",\"valueZh\":\"0.1% VOl O2\"}],\"description\":{\"en\":\"HH-4O2LF-30%VOL is an HH electrochemical gas sensor for lead-free oxygen, with range 0-30%, output\/sensitivity 0.10\u00b10.03mA(\u7a7a\u6c14\u4e2d), response time \u226415\u79d2.\",\"zh\":\"HH-4O2LF-30%VOL \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u65e0\u94c5\u6c27\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o2lf-30-vol-75f98ec0bd0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4o2lf-30-vol-151e95d3e5ce.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-cocl2-1-54\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-COCL2-1\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"COCL2\",\"gasName\":{\"en\":\"Phosgene\",\"zh\":\"\u5149\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01ppm\",\"resolutionZh\":\"0.01ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-1\",\"valueZh\":\"0-1\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01ppm\",\"valueZh\":\"0.01ppm\"}],\"description\":{\"en\":\"HH-COCL2-1 is an HH electrochemical gas sensor for phosgene, with range 0-1, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-COCL2-1 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u5149\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4o3-0141cfbfabad.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4cocl2-1-be2b36c7f7d1.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-4cs2-55\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4CS2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CS2\",\"gasName\":{\"en\":\"Carbon Disulfide\",\"zh\":\"\u4e8c\u786b\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-4CS2 is an HH electrochemical gas sensor for carbon disulfide, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-4CS2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u786b\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4cs2-100-7a4da042d182.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-c4h8o-56\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C4H8O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C4H8O_THF\",\"gasName\":{\"en\":\"Tetrahydrofuran\",\"zh\":\"\u56db\u6c22\u544b\u5583\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C4H8O is an HH electrochemical gas sensor for tetrahydrofuran, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C4H8O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u56db\u6c22\u544b\u5583\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c4h8s-57\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C4H8S\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"THT\",\"gasName\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C4H8S is an HH electrochemical gas sensor for tetrahydrothiophene, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C4H8S \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u56db\u6c22\u567b\u5429\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c3h8o-58\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C3H8O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C3H8O\",\"gasName\":{\"en\":\"Isopropyl Alcohol\",\"zh\":\"\u5f02\u4e19\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C3H8O is an HH electrochemical gas sensor for isopropyl alcohol, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C3H8O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u5f02\u4e19\u9187\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c4h10o-59\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C4H10O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C4H10O_BUTANOL\",\"gasName\":{\"en\":\"n-Butanol\",\"zh\":\"\u6b63\u4e01\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C4H10O is an HH electrochemical gas sensor for n-butanol, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C4H10O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6b63\u4e01\u9187\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c8h18o-60\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C8H18O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C8H18O\",\"gasName\":{\"en\":\"1-Octanol\",\"zh\":\"\u6b63\u8f9b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C8H18O is an HH electrochemical gas sensor for 1-octanol, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C8H18O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6b63\u8f9b\u9187\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c10h18o-61\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C10H18O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C10H18O\",\"gasName\":{\"en\":\"Terpineol\",\"zh\":\"\u677e\u6cb9\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C10H18O is an HH electrochemical gas sensor for terpineol, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C10H18O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u677e\u6cb9\u9187\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c8h20o4si-62\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C8H20O4Si\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"TEOS\",\"gasName\":{\"en\":\"Tetraethyl Orthosilicate\",\"zh\":\"\u6b63\u7845\u9178\u4e59\u916f\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C8H20O4Si is an HH electrochemical gas sensor for tetraethyl orthosilicate, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C8H20O4Si \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6b63\u7845\u9178\u4e59\u916f\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c4h10o-63\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C4H10O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C4H10O_ETHER\",\"gasName\":{\"en\":\"Diethyl Ether\",\"zh\":\"\u4e59\u919a\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C4H10O is an HH electrochemical gas sensor for diethyl ether, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C4H10O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e59\u919a\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-c3h6o-64\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C3H6O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C3H6O\",\"gasName\":{\"en\":\"Acetone\",\"zh\":\"\u4e19\u916e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C3H6O is an HH electrochemical gas sensor for acetone, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C3H6O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e19\u916e\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c3h6o-150-1813d7beab28.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-c6h5oh-65\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-C6H5OH\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C6H5OH\",\"gasName\":{\"en\":\"Phenol\",\"zh\":\"\u82ef\u915a\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-C6H5OH is an HH electrochemical gas sensor for phenol, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-C6H5OH \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u82ef\u915a\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4c6h5oh-100-8dbac63cfddb.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-ch3nh2-66\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-CH3NH2\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH3NH2\",\"gasName\":{\"en\":\"Methylamine\",\"zh\":\"\u7532\u80fa\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-CH3NH2 is an HH electrochemical gas sensor for methylamine, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-CH3NH2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u80fa\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-hbr-67\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-HBR\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"HBR\",\"gasName\":{\"en\":\"Hydrogen Bromide\",\"zh\":\"\u6eb4\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"0.05\u00b10.015uA \/ ppm\",\"signal\":\"0.05\u00b10.015uA \/ ppm\",\"signalZh\":\"0.05\u00b10.015uA \/ ppm\",\"responseTime\":\"\u2264120\u79d2\",\"responseTimeZh\":\"\u2264120\u79d2\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1ppm\",\"resolutionZh\":\"1ppm\",\"voltage\":\"\u2264\u00b11\",\"voltageZh\":\"\u2264\u00b11\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"0.05\u00b10.015uA \/ ppm\",\"valueZh\":\"0.05\u00b10.015uA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264120\u79d2\",\"valueZh\":\"\u2264120\u79d2\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1ppm\",\"valueZh\":\"1ppm\"}],\"description\":{\"en\":\"HH-HBR is an HH electrochemical gas sensor for hydrogen bromide, with range 0-100, output\/sensitivity 0.05\u00b10.015uA \/ ppm, response time \u2264120\u79d2.\",\"zh\":\"HH-HBR \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6eb4\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4ch3sh-392abf914b8a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-4hbr-100-e3515b65ea1d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-2ch2o-68\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-2CH2O\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5\",\"sensitivity\":\"150~350nA \/ ppm\",\"signal\":\"150~350nA \/ ppm\",\"signalZh\":\"150~350nA \/ ppm\",\"responseTime\":\"\u2264 30 s\",\"responseTimeZh\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01ppm\",\"resolutionZh\":\"0.01ppm\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5\",\"valueZh\":\"0-5\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150~350nA \/ ppm\",\"valueZh\":\"150~350nA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 30 s\",\"valueZh\":\"\u2264 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01ppm\",\"valueZh\":\"0.01ppm\"}],\"description\":{\"en\":\"HH-2CH2O is an HH electrochemical gas sensor for formaldehyde, with range 0-5, output\/sensitivity 150~350nA \/ ppm, response time \u2264 30 s.\",\"zh\":\"HH-2CH2O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-2ch2o-6eee59509a9c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-2hcho-5-4a98da2342e2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-2co-69\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-2CO\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1000\",\"sensitivity\":\"3-9nA \/ ppm\",\"signal\":\"3-9nA \/ ppm\",\"signalZh\":\"3-9nA \/ ppm\",\"responseTime\":\"\u2264 60 s\",\"responseTimeZh\":\"\u2264 60 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.5ppm\",\"resolutionZh\":\"0.5ppm\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-1000\",\"valueZh\":\"0-1000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"3-9nA \/ ppm\",\"valueZh\":\"3-9nA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 60 s\",\"valueZh\":\"\u2264 60 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.5ppm\",\"valueZh\":\"0.5ppm\"}],\"description\":{\"en\":\"HH-2CO is an HH electrochemical gas sensor for carbon monoxide, with range 0-1000, output\/sensitivity 3-9nA \/ ppm, response time \u2264 60 s.\",\"zh\":\"HH-2CO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-2ch2o-6eee59509a9c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-2co-1000-3fc941858689.pdf\",\"match\":\"exact\"},{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-2co-1000-49d0607e5ee4.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-2c2h5oh-71\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-2C2H5OH\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"C2H5OH\",\"gasName\":{\"en\":\"Ethanol\",\"zh\":\"\u9152\u7cbe\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-500\",\"sensitivity\":\"150~350nA \/ ppm\",\"signal\":\"150~350nA \/ ppm\",\"signalZh\":\"150~350nA \/ ppm\",\"responseTime\":\"\u2264 30 s\",\"responseTimeZh\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01ppm\",\"resolutionZh\":\"0.01ppm\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-500\",\"valueZh\":\"0-500\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150~350nA \/ ppm\",\"valueZh\":\"150~350nA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 30 s\",\"valueZh\":\"\u2264 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01ppm\",\"valueZh\":\"0.01ppm\"}],\"description\":{\"en\":\"HH-2C2H5OH is an HH electrochemical gas sensor for ethanol, with range 0-500, output\/sensitivity 150~350nA \/ ppm, response time \u2264 30 s.\",\"zh\":\"HH-2C2H5OH \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u9152\u7cbe\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-2c2h5oh-3d863afe780a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-2c2h5oh-500-8026889f480d.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-2o3-72\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-2O3\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5 \/ 0-100\",\"sensitivity\":\"150~350nA \/ ppm\",\"signal\":\"150~350nA \/ ppm\",\"signalZh\":\"150~350nA \/ ppm\",\"responseTime\":\"\u2264 30 s\",\"responseTimeZh\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01ppm\",\"resolutionZh\":\"0.01ppm\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5 \/ 0-100\",\"valueZh\":\"0-5 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150~350nA \/ ppm\",\"valueZh\":\"150~350nA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 30 s\",\"valueZh\":\"\u2264 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01ppm\",\"valueZh\":\"0.01ppm\"}],\"description\":{\"en\":\"HH-2O3 is an HH electrochemical gas sensor for ozone, with range 0-5 \/ 0-100, output\/sensitivity 150~350nA \/ ppm, response time \u2264 30 s.\",\"zh\":\"HH-2O3 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-2o3-0078a1ad7a4c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-2o3-1-b57dae19da6f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-2nh3-73\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-2NH3\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"NH3\",\"gasName\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5 \/ 0-100\",\"sensitivity\":\"150~350nA \/ ppm\",\"signal\":\"150~350nA \/ ppm\",\"signalZh\":\"150~350nA \/ ppm\",\"responseTime\":\"See official handbook\",\"responseTimeZh\":\"\u89c1\u5b98\u65b9\u624b\u518c\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1PPM\",\"resolutionZh\":\"0.1PPM\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5 \/ 0-100\",\"valueZh\":\"0-5 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150~350nA \/ ppm\",\"valueZh\":\"150~350nA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"See official handbook\",\"valueZh\":\"\u89c1\u5b98\u65b9\u624b\u518c\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1PPM\",\"valueZh\":\"0.1PPM\"}],\"description\":{\"en\":\"HH-2NH3 is an HH electrochemical gas sensor for ammonia, with range 0-5 \/ 0-100, output\/sensitivity 150~350nA \/ ppm, response time See official handbook.\",\"zh\":\"HH-2NH3 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c28\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-2c2h5oh-3d863afe780a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-asset-c59addb1bece.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-2h2s-74\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-2H2S\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:electrochemical-sensors\",\"series\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100\",\"sensitivity\":\"150~350nA \/ ppm\",\"signal\":\"150~350nA \/ ppm\",\"signalZh\":\"150~350nA \/ ppm\",\"responseTime\":\"\u2264 30 s\",\"responseTimeZh\":\"\u2264 30 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01ppm\",\"resolutionZh\":\"0.01ppm\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100\",\"valueZh\":\"0-10 \/ 0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"150~350nA \/ ppm\",\"valueZh\":\"150~350nA \/ ppm\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 30 s\",\"valueZh\":\"\u2264 30 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01ppm\",\"valueZh\":\"0.01ppm\"}],\"description\":{\"en\":\"HH-2H2S is an HH electrochemical gas sensor for hydrogen sulfide, with range 0-10 \/ 0-100, output\/sensitivity 150~350nA \/ ppm, response time \u2264 30 s.\",\"zh\":\"HH-2H2S \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-2c2h5oh-3d863afe780a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-2h2s-10-cc160faa58d7.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-003-84\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-003\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"C2H5OH\",\"gasName\":{\"en\":\"Ethanol\",\"zh\":\"\u9152\u7cbe\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-500\",\"sensitivity\":\"Rs(in air)\/Rs(in 125ppm \u9152\u7cbe)\u22652.5\",\"signal\":\"Rs(in air)\/Rs(in 125ppm \u9152\u7cbe)\u22652.5\",\"signalZh\":\"Rs(in air)\/Rs(in 125ppm \u9152\u7cbe)\u22652.5\",\"responseTime\":\"\u2264 10 s\",\"responseTimeZh\":\"\u2264 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"0.9V\",\"voltageZh\":\"0.9V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-500\",\"valueZh\":\"0-500\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Rs(in air)\/Rs(in 125ppm \u9152\u7cbe)\u22652.5\",\"valueZh\":\"Rs(in air)\/Rs(in 125ppm \u9152\u7cbe)\u22652.5\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 10 s\",\"valueZh\":\"\u2264 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HH-003 is an HH metal oxide semiconductor gas sensor for ethanol, with range 0-500, output\/sensitivity Rs(in air)\/Rs(in 125ppm \u9152\u7cbe)\u22652.5, response time \u2264 10 s.\",\"zh\":\"HH-003 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u9152\u7cbe\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-003-9b0a8cb62184.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-003-a6256628159b.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-11-85\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-11\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-100\",\"sensitivity\":\"Rs(in air)\/Rs(10ppm \u9152\u7cbe)\u22650.5\",\"signal\":\"Rs(in air)\/Rs(10ppm \u9152\u7cbe)\u22650.5\",\"signalZh\":\"Rs(in air)\/Rs(10ppm \u9152\u7cbe)\u22650.5\",\"responseTime\":\"\u2264 10 s\",\"responseTimeZh\":\"\u2264 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100\",\"valueZh\":\"0-100\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Rs(in air)\/Rs(10ppm \u9152\u7cbe)\u22650.5\",\"valueZh\":\"Rs(in air)\/Rs(10ppm \u9152\u7cbe)\u22650.5\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 10 s\",\"valueZh\":\"\u2264 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HH-11 is an HH metal oxide semiconductor gas sensor for volatile organic compounds, with range 0-100, output\/sensitivity Rs(in air)\/Rs(10ppm \u9152\u7cbe)\u22650.5, response time \u2264 10 s.\",\"zh\":\"HH-11 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-11-e9bd2bd8e3c1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-11-3-6-1-9fd96ba89dae.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-14-86\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-14\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-10000\",\"sensitivity\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"signal\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"signalZh\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"responseTime\":\"\u2264 10 s\",\"responseTimeZh\":\"\u2264 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000\",\"valueZh\":\"0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"valueZh\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 10 s\",\"valueZh\":\"\u2264 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HH-14 is an HH metal oxide semiconductor gas sensor for methane, with range 0-10000, output\/sensitivity Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652, response time \u2264 10 s.\",\"zh\":\"HH-14 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-11-e9bd2bd8e3c1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-14-3-5-58d91445997c.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-16-87\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-16\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"C3H8\",\"gasName\":{\"en\":\"Propane\",\"zh\":\"\u4e19\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-10000\",\"sensitivity\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"signal\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"signalZh\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"responseTime\":\"\u2264 10 s\",\"responseTimeZh\":\"\u2264 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000\",\"valueZh\":\"0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"valueZh\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 10 s\",\"valueZh\":\"\u2264 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HH-16 is an HH metal oxide semiconductor gas sensor for propane, with range 0-10000, output\/sensitivity Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652, response time \u2264 10 s.\",\"zh\":\"HH-16 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e19\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-11-e9bd2bd8e3c1.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-16-3-5-7893a33049ec.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-04-88\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-04\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-10000\",\"sensitivity\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"signal\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"signalZh\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"responseTime\":\"\u2264 10 s\",\"responseTimeZh\":\"\u2264 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000\",\"valueZh\":\"0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\",\"valueZh\":\"Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 10 s\",\"valueZh\":\"\u2264 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HH-04 is an HH metal oxide semiconductor gas sensor for methane, with range 0-10000, output\/sensitivity Rs(in air)\/Rs(5000ppm \u7532\u70f7)\u22652, response time \u2264 10 s.\",\"zh\":\"HH-04 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-04-8b651c15d5fb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh04-f9b7aa5c7bef.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-06-89\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-06\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"C3H8\",\"gasName\":{\"en\":\"Propane\",\"zh\":\"\u4e19\u70f7\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-10000\",\"sensitivity\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"signal\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"signalZh\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"responseTime\":\"\u2264 10 s\",\"responseTimeZh\":\"\u2264 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000\",\"valueZh\":\"0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\",\"valueZh\":\"Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"\u2264 10 s\",\"valueZh\":\"\u2264 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HH-06 is an HH metal oxide semiconductor gas sensor for propane, with range 0-10000, output\/sensitivity Rs(in air)\/Rs(2000ppm \u4e19\u70f7)\u22652, response time \u2264 10 s.\",\"zh\":\"HH-06 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e19\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-04-8b651c15d5fb.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh06-e69a79bbb5c3.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hl-1ch-90\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HL-1CH\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Sensors &#038; Modules\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-10000\",\"sensitivity\":\"Bridge differential output (see datasheet)\",\"signal\":\"Bridge differential output (see datasheet)\",\"signalZh\":\"\u7535\u6865\u5dee\u5206\u8f93\u51fa\uff08\u89c1\u8d44\u6599\uff09\",\"responseTime\":\"< 20 s\",\"responseTimeZh\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000\",\"valueZh\":\"0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Bridge differential output (see datasheet)\",\"valueZh\":\"\u7535\u6865\u5dee\u5206\u8f93\u51fa\uff08\u89c1\u8d44\u6599\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 20 s\",\"valueZh\":\"< 20 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HL-1CH is an HH catalytic combustion gas sensor for methane, with range 0-10000, output\/sensitivity Bridge differential output (see datasheet), response time < 20 s.\",\"zh\":\"HL-1CH \u662f\u534e\u6df1\u79d1\u7684\u50ac\u5316\u71c3\u70e7\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hl-1ch-eb2fed2b6d51.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hl-1ch-94754075e43f.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hl-1cha-91\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HL-1CHA\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Sensors &#038; Modules\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-10000\",\"sensitivity\":\"Bridge differential output (see datasheet)\",\"signal\":\"Bridge differential output (see datasheet)\",\"signalZh\":\"\u7535\u6865\u5dee\u5206\u8f93\u51fa\uff08\u89c1\u8d44\u6599\uff09\",\"responseTime\":\"< 20 s\",\"responseTimeZh\":\"< 20 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000\",\"valueZh\":\"0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Bridge differential output (see datasheet)\",\"valueZh\":\"\u7535\u6865\u5dee\u5206\u8f93\u51fa\uff08\u89c1\u8d44\u6599\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 20 s\",\"valueZh\":\"< 20 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HL-1CHA is an HH catalytic combustion gas sensor for combustible gas, with range 0-10000, output\/sensitivity Bridge differential output (see datasheet), response time < 20 s.\",\"zh\":\"HL-1CHA \u662f\u534e\u6df1\u79d1\u7684\u50ac\u5316\u71c3\u70e7\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u53ef\u71c3\u6c14\u4f53\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hl-1ch-eb2fed2b6d51.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hl-1cha-3f2c9bb54cf8.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-113-92\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-113\",\"partNumber\":\"\",\"productClass\":\"SENSOR\",\"productClassName\":{\"en\":\"Gas Sensor\",\"zh\":\"\u6c14\u4f53\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Sensors &#038; Modules\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-10000\",\"sensitivity\":\"Bridge differential output (see datasheet)\",\"signal\":\"Bridge differential output (see datasheet)\",\"signalZh\":\"\u7535\u6865\u5dee\u5206\u8f93\u51fa\uff08\u89c1\u8d44\u6599\uff09\",\"responseTime\":\"< 10 s\",\"responseTimeZh\":\"< 10 s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"Application-dependent\",\"resolutionZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000\",\"valueZh\":\"0-10000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"Bridge differential output (see datasheet)\",\"valueZh\":\"\u7535\u6865\u5dee\u5206\u8f93\u51fa\uff08\u89c1\u8d44\u6599\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"< 10 s\",\"valueZh\":\"< 10 s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"Application-dependent\",\"valueZh\":\"\u53d6\u51b3\u4e8e\u5e94\u7528\u7535\u8def\"}],\"description\":{\"en\":\"HH-113 is an HH catalytic combustion gas sensor for combustible gas, with range 0-10000, output\/sensitivity Bridge differential output (see datasheet), response time < 10 s.\",\"zh\":\"HH-113 \u662f\u534e\u6df1\u79d1\u7684\u50ac\u5316\u71c3\u70e7\u6c14\u4f53\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u53ef\u71c3\u6c14\u4f53\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-113-e1178b47974a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh113-1-de2415f46e87.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:4mz-hh-4o3-94\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4O3\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100 \/ 0-1000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100 \/ 0-1000PPM\",\"valueZh\":\"0-10 \/ 0-100 \/ 0-1000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4O3 is an HH electrochemical sensor module for ozone, with range 0-10 \/ 0-100 \/ 0-1000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4O3 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4o3-2c482b0732f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4no2-95\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4NO2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"NO2\",\"gasName\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100 \/ 0-1000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100 \/ 0-1000PPM\",\"valueZh\":\"0-20 \/ 0-100 \/ 0-1000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4NO2 is an HH electrochemical sensor module for nitrogen dioxide, with range 0-20 \/ 0-100 \/ 0-1000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4NO2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u6c2e\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4o3-2c482b0732f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4so2-96\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4SO2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"SO2\",\"gasName\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100 \/ 0-2000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100 \/ 0-2000PPM\",\"valueZh\":\"0-20 \/ 0-100 \/ 0-2000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4SO2 is an HH electrochemical sensor module for sulfur dioxide, with range 0-20 \/ 0-100 \/ 0-2000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4SO2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u786b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4so2-a1f6112d5953.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4ch2o-97\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4CH2O\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-1000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-1000PPM\",\"valueZh\":\"0-10 \/ 0-1000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4CH2O is an HH electrochemical sensor module for formaldehyde, with range 0-10 \/ 0-1000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4CH2O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4ch2o-6d3d15fb62c6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4ph3-98\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4PH3\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"PH3\",\"gasName\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-2000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-2000PPM\",\"valueZh\":\"0-20 \/ 0-2000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4PH3 is an HH electrochemical sensor module for phosphine, with range 0-20 \/ 0-2000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4PH3 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u78f7\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4so2-a1f6112d5953.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4h2s-99\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4H2S\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-2 \/ 0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-2 \/ 0-100PPM\",\"valueZh\":\"0-2 \/ 0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4H2S is an HH electrochemical sensor module for hydrogen sulfide, with range 0-2 \/ 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4H2S \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4h2s-2b45621c031f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4hf-100\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4HF\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"HF\",\"gasName\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100PPM\",\"valueZh\":\"0-10 \/ 0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4HF is an HH electrochemical sensor module for hydrogen fluoride, with range 0-10 \/ 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4HF \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c1f\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4hf-4ca15f5ec013.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4c12-101\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4C12\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"CL2\",\"gasName\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100 \/ 0-1000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100 \/ 0-1000PPM\",\"valueZh\":\"0-10 \/ 0-100 \/ 0-1000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4C12 is an HH electrochemical sensor module for chlorine, with range 0-10 \/ 0-100 \/ 0-1000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4C12 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4o3-2c482b0732f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4hcn-103\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4HCN\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"HCN\",\"gasName\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100PPM\",\"valueZh\":\"0-10 \/ 0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4HCN is an HH electrochemical sensor module for hydrogen cyanide, with range 0-10 \/ 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4HCN \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c30\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4so2-a1f6112d5953.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4co-104\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4CO\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-50 \/ 0-1000 \/ 0120000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-50 \/ 0-1000 \/ 0120000PPM\",\"valueZh\":\"0-50 \/ 0-1000 \/ 0120000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4CO is an HH electrochemical sensor module for carbon monoxide, with range 0-50 \/ 0-1000 \/ 0120000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4CO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4co-2517d0faf97c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4hcl-106\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4HCL\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"HCL\",\"gasName\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100PPM\",\"valueZh\":\"0-10 \/ 0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4HCL is an HH electrochemical sensor module for hydrogen chloride, with range 0-10 \/ 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4HCL \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4o3-2c482b0732f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4h2o2-107\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4H2O2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"H2O2\",\"gasName\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1000PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-1000PPM\",\"valueZh\":\"0-1000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4H2O2 is an HH electrochemical sensor module for hydrogen peroxide, with range 0-1000PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4H2O2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u8fc7\u6c27\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4co-2517d0faf97c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4tvoc-108\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4TVOC\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100PPM\",\"valueZh\":\"0-10 \/ 0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4TVOC is an HH electrochemical sensor module for volatile organic compounds, with range 0-10 \/ 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4TVOC \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4tvoc-ea013192fcca.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4ch3sh-109\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4CH3SH\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"CH3SH\",\"gasName\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4CH3SH is an HH electrochemical sensor module for methanethiol, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4CH3SH \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u786b\u9187\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4ch3sh-307cc947ed0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4c6h6-110\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4C6H6\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"C6H6\",\"gasName\":{\"en\":\"Benzene\",\"zh\":\"\u82ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-200PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-200PPM\",\"valueZh\":\"0-200PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4C6H6 is an HH electrochemical sensor module for benzene, with range 0-200PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4C6H6 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u82ef\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4ch3sh-307cc947ed0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4ch2chcn-112\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4CH2CHCN\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"C3H3N\",\"gasName\":{\"en\":\"Acrylonitrile\",\"zh\":\"\u4e19\u70ef\u8148\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4CH2CHCN is an HH electrochemical sensor module for acrylonitrile, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4CH2CHCN \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e19\u70ef\u8148\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4ch3sh-307cc947ed0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-c2h6s-113\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-C2H6S\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"C2H6S\",\"gasName\":{\"en\":\"Dimethyl Sulfide\",\"zh\":\"\u7532\u786b\u919a\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-C2H6S is an HH electrochemical sensor module for dimethyl sulfide, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-C2H6S \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u786b\u919a\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4ch3sh-307cc947ed0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4eto-117\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4ETO\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"ETO\",\"gasName\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100 \/ 0-500PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100 \/ 0-500PPM\",\"valueZh\":\"0-10 \/ 0-100 \/ 0-500PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4ETO is an HH electrochemical sensor module for ethylene oxide, with range 0-10 \/ 0-100 \/ 0-500PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4ETO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4ch3sh-307cc947ed0a.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4no-118\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4NO\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"NO\",\"gasName\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-20 \/ 0-100 \/ 0-250PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20 \/ 0-100 \/ 0-250PPM\",\"valueZh\":\"0-20 \/ 0-100 \/ 0-250PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4NO is an HH electrochemical sensor module for nitric oxide, with range 0-20 \/ 0-100 \/ 0-250PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4NO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u6c2e\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4no-d1cb3a9934d7.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4c2h3c1-119\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4C2H3C1\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"C2H3CL\",\"gasName\":{\"en\":\"Vinyl Chloride\",\"zh\":\"\u6c2f\u4e59\u70ef\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10 \/ 0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10 \/ 0-100PPM\",\"valueZh\":\"0-10 \/ 0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4C2H3C1 is an HH electrochemical sensor module for vinyl chloride, with range 0-10 \/ 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4C2H3C1 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c2f\u4e59\u70ef\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4co-2517d0faf97c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4o2-30-vol-120\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4O2-30%VOL\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30%VOL\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30%VOL\",\"valueZh\":\"0-30%VOL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4O2-30%VOL is an HH electrochemical sensor module for oxygen, with range 0-30%VOL, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4O2-30%VOL \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4o2-30-vol-c2302a6450e0.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4o2lf-30-vol-122\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4O2LF-30%VOL\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Lead-Free Oxygen\",\"zh\":\"\u65e0\u94c5\u6c27\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-30%\u65e0\u94c5\u6c27\u6c14\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-30%\u65e0\u94c5\u6c27\u6c14\",\"valueZh\":\"0-30%\u65e0\u94c5\u6c27\u6c14\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4O2LF-30%VOL is an HH electrochemical sensor module for lead-free oxygen, with range 0-30%\u65e0\u94c5\u6c27\u6c14, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4O2LF-30%VOL \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u65e0\u94c5\u6c27\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4o2lf-30-vol-861ceeee98c9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-cocl2-123\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-COCL2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"COCL2\",\"gasName\":{\"en\":\"Phosgene\",\"zh\":\"\u5149\u6c14\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-1PPM\",\"valueZh\":\"0-1PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-COCL2 is an HH electrochemical sensor module for phosgene, with range 0-1PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-COCL2 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u5149\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4o3-2c482b0732f5.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4cs2-100-124\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-4CS2-100\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"CS2\",\"gasName\":{\"en\":\"Carbon Disulfide\",\"zh\":\"\u4e8c\u786b\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-4CS2-100 is an HH electrochemical sensor module for carbon disulfide, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-4CS2-100 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u786b\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4cs2-100-97d984570090.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:2mz-hh-2ch2o-137\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"2MZ-HH-2CH2O\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"CH2O\",\"gasName\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5.00\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.6~5 .5V DC\",\"voltageZh\":\"3.6~5 .5V DC\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5.00\",\"valueZh\":\"0-5.00\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"2MZ-HH-2CH2O is an HH electrochemical sensor module for formaldehyde, with range 0-5.00, output\/sensitivity UART, response time T90<30s.\",\"zh\":\"2MZ-HH-2CH2O \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u919b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-2mz-hh-2ch2o-ed1b263207b6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-20260330-8e2a8bed4b18.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:2mz-hh-2co-138\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"2MZ-HH-2CO\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"CO\",\"gasName\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-1000\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.6~5 .5V DC\",\"voltageZh\":\"3.6~5 .5V DC\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-1000\",\"valueZh\":\"0-1000\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"2MZ-HH-2CO is an HH electrochemical sensor module for carbon monoxide, with range 0-1000, output\/sensitivity UART, response time T90<30s.\",\"zh\":\"2MZ-HH-2CO \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e00\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-2mz-hh-2co-3d0d16b104f3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-20260330-8e2a8bed4b18.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:2mz-hh-2c2h5oh-139\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"2MZ-HH-2C2H5OH\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"C2H5OH\",\"gasName\":{\"en\":\"Ethanol\",\"zh\":\"\u9152\u7cbe\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-500\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.6~5 .5V DC\",\"voltageZh\":\"3.6~5 .5V DC\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-500\",\"valueZh\":\"0-500\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"2MZ-HH-2C2H5OH is an HH electrochemical sensor module for ethanol, with range 0-500, output\/sensitivity UART, response time T90<30s.\",\"zh\":\"2MZ-HH-2C2H5OH \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u9152\u7cbe\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-2mz-hh-2c2h5oh-131a7578a02e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-20260330-8e2a8bed4b18.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:2mz-hh-2o3-140\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"2MZ-HH-2O3\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"O3\",\"gasName\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-5.00\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.6~5 .5V DC\",\"voltageZh\":\"3.6~5 .5V DC\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5.00\",\"valueZh\":\"0-5.00\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"2MZ-HH-2O3 is an HH electrochemical sensor module for ozone, with range 0-5.00, output\/sensitivity UART, response time T90<30s.\",\"zh\":\"2MZ-HH-2O3 \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u81ed\u6c27\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-2mz-hh-2o3-bcd283bc391d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-20260330-8e2a8bed4b18.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:2mz-hh-2h2s-141\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"2MZ-HH-2H2S\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:electrochemical-modules\",\"series\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"},\"gas\":\"H2S\",\"gasName\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"},\"tech\":\"ELECTROCHEMICAL\",\"techName\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"},\"specs\":{\"range\":\"0-10.00\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.6~5 .5V DC\",\"voltageZh\":\"3.6~5 .5V DC\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10.00\",\"valueZh\":\"0-10.00\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"2MZ-HH-2H2S is an HH electrochemical sensor module for hydrogen sulfide, with range 0-10.00, output\/sensitivity UART, response time T90<30s.\",\"zh\":\"2MZ-HH-2H2S \u662f\u534e\u6df1\u79d1\u7684\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u786b\u5316\u6c22\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-2mz-hh-2c2h5oh-131a7578a02e.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-20260330-8e2a8bed4b18.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-4-142\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u534a\u5bfc\u4f534\u7b49\u7ea7\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u534a\u5bfc\u4f534\u7b49\u7ea7 is an HH metal oxide semiconductor sensor module for air quality, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-\u534a\u5bfc\u4f534\u7b49\u7ea7 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u7a7a\u6c14\u8d28\u91cf\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-4-2b9278d616fe.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-143\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u534a\u5bfc\u4f53\u6570\u663e\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"AIR_QUALITY\",\"gasName\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u534a\u5bfc\u4f53\u6570\u663e is an HH metal oxide semiconductor sensor module for air quality, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-\u534a\u5bfc\u4f53\u6570\u663e \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u7a7a\u6c14\u8d28\u91cf\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-7c5ec6785601.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-144\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u534a\u5bfc\u4f53\u82ef\/\u7532\u82ef\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"ASSET\",\"gasName\":{\"en\":\"\u82ef \/ \u7532\u82ef\",\"zh\":\"\u82ef \/ \u7532\u82ef\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u534a\u5bfc\u4f53\u82ef\/\u7532\u82ef is an HH metal oxide semiconductor sensor module for \u82ef \/ \u7532\u82ef, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-\u534a\u5bfc\u4f53\u82ef\/\u7532\u82ef \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u82ef \/ \u7532\u82ef\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-e372d26c0d6d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-145\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u534a\u5bfc\u4f53\u53ef\u71c3\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-100LEL\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100LEL\",\"valueZh\":\"0-100LEL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u534a\u5bfc\u4f53\u53ef\u71c3 is an HH metal oxide semiconductor sensor module for combustible gas, with range 0-100LEL, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-\u534a\u5bfc\u4f53\u53ef\u71c3 \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u53ef\u71c3\u6c14\u4f53\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-e372d26c0d6d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-voc-146\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u534a\u5bfc\u4f53VOC\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"VOC\",\"gasName\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d486\uff09\",\"signal\":\"UART\uff08\u9009\u914d486\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d486\uff09\",\"responseTime\":\"T90<31s\",\"responseTimeZh\":\"T90<31s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"2%FSD\",\"resolutionZh\":\"2%FSD\",\"voltage\":\"3.7V-6V\",\"voltageZh\":\"3.7V-6V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d486\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d486\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<31s\",\"valueZh\":\"T90<31s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"2%FSD\",\"valueZh\":\"2%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u534a\u5bfc\u4f53VOC is an HH metal oxide semiconductor sensor module for volatile organic compounds, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d486\uff09, response time T90<31s.\",\"zh\":\"4MZ-HH-\u534a\u5bfc\u4f53VOC \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6325\u53d1\u6027\u6709\u673a\u7269\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-e372d26c0d6d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-ex-147\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u534a\u5bfc\u4f53EX\u6361\u6f0f\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:mos-semiconductor\",\"series\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"PETROLEUM_VAPOR\",\"gasName\":{\"en\":\"Gasoline \/ Kerosene Vapor\",\"zh\":\"\u6c7d\u6cb9 \/ \u7164\u6cb9\u84b8\u6c14\"},\"tech\":\"MOS\",\"techName\":{\"en\":\"Metal Oxide Semiconductor\",\"zh\":\"\u534a\u5bfc\u4f53\"},\"specs\":{\"range\":\"0-100PPM\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100PPM\",\"valueZh\":\"0-100PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u534a\u5bfc\u4f53EX\u6361\u6f0f is an HH metal oxide semiconductor sensor module for gasoline \/ kerosene vapor, with range 0-100PPM, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-\u534a\u5bfc\u4f53EX\u6361\u6f0f \u662f\u534e\u6df1\u79d1\u7684\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c7d\u6cb9 \/ \u7164\u6cb9\u84b8\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-e372d26c0d6d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-148\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u9632\u7206\u50ac\u5316\u71c3\u70e7\u7532\u70f7\/\u4e19\u70f7\/\u4e59\u7094\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Sensors &#038; Modules\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100LEL\",\"sensitivity\":\"UART\uff08\u9009\u914d485\uff09\",\"signal\":\"UART\uff08\u9009\u914d485\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d485\uff09\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100LEL\",\"valueZh\":\"0-100LEL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d485\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d485\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u9632\u7206\u50ac\u5316\u71c3\u70e7\u7532\u70f7\/\u4e19\u70f7\/\u4e59\u7094 is an HH catalytic combustion sensor module for combustible gas, with range 0-100LEL, output\/sensitivity UART\uff08\u9009\u914d485\uff09, response time T90<30s.\",\"zh\":\"4MZ-HH-\u9632\u7206\u50ac\u5316\u71c3\u70e7\u7532\u70f7\/\u4e19\u70f7\/\u4e59\u7094 \u662f\u534e\u6df1\u79d1\u7684\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u53ef\u71c3\u6c14\u4f53\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-79be7511e803.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:4mz-hh-149\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u50ac\u5316\u71c3\u70e7\u7532\u70f7\/\u4e19\u70f7\/\u4e59\u7094\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Sensor Module\",\"zh\":\"\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:catalytic-combustion\",\"series\":{\"en\":\"Catalytic Sensors &#038; Modules\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"LEL\",\"gasName\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"},\"tech\":\"CATALYTIC\",\"techName\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"},\"specs\":{\"range\":\"0-100LEL\",\"sensitivity\":\"UART\uff08\u9009\u914d486\uff09\",\"signal\":\"UART\uff08\u9009\u914d486\uff09\",\"signalZh\":\"UART\uff08\u9009\u914d486\uff09\",\"responseTime\":\"T90<31s\",\"responseTimeZh\":\"T90<31s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1%FSD\",\"resolutionZh\":\"1%FSD\",\"voltage\":\"3.7V-6V\",\"voltageZh\":\"3.7V-6V\",\"accuracy\":\"\u00b15%F.S\",\"accuracyZh\":\"\u00b15%F.S\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100LEL\",\"valueZh\":\"0-100LEL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\uff08\u9009\u914d486\uff09\",\"valueZh\":\"UART\uff08\u9009\u914d486\uff09\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<31s\",\"valueZh\":\"T90<31s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1%FSD\",\"valueZh\":\"1%FSD\"}],\"description\":{\"en\":\"4MZ-HH-\u50ac\u5316\u71c3\u70e7\u7532\u70f7\/\u4e19\u70f7\/\u4e59\u7094 is an HH catalytic combustion sensor module for combustible gas, with range 0-100LEL, output\/sensitivity UART\uff08\u9009\u914d486\uff09, response time T90<31s.\",\"zh\":\"4MZ-HH-\u50ac\u5316\u71c3\u70e7\u7532\u70f7\/\u4e19\u70f7\/\u4e59\u7094 \u662f\u534e\u6df1\u79d1\u7684\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u53ef\u71c3\u6c14\u4f53\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-e372d26c0d6d.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-x8c-5000-150\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-X8C-5000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"0-5000PPM\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<30s\",\"responseTimeZh\":\"T90<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1PPM\",\"resolutionZh\":\"1PPM\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-5000PPM\",\"valueZh\":\"0-5000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<30s\",\"valueZh\":\"T90<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1PPM\",\"valueZh\":\"1PPM\"}],\"description\":{\"en\":\"HH-X8C-5000 is an HH ndir infrared infrared sensor module for carbon dioxide, with range 0-5000PPM, output\/sensitivity UART, response time T90<30s.\",\"zh\":\"HH-X8C-5000 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-x8c-5000-21dbf64103a2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-v1-1-1-e9880aa427b0.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-x8c-10000-151\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-X8C-10000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"0-10000PPM\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<31s\",\"responseTimeZh\":\"T90<31s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1PPM\",\"resolutionZh\":\"1PPM\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-10000PPM\",\"valueZh\":\"0-10000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<31s\",\"valueZh\":\"T90<31s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1PPM\",\"valueZh\":\"1PPM\"}],\"description\":{\"en\":\"HH-X8C-10000 is an HH ndir infrared infrared sensor module for carbon dioxide, with range 0-10000PPM, output\/sensitivity UART, response time T90<31s.\",\"zh\":\"HH-X8C-10000 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-x8c-5000-21dbf64103a2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-v1-1-1-e9880aa427b0.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-x8c-20000-152\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-X8C-20000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"0-20000PPM\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<32s\",\"responseTimeZh\":\"T90<32s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1PPM\",\"resolutionZh\":\"1PPM\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-20000PPM\",\"valueZh\":\"0-20000PPM\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<32s\",\"valueZh\":\"T90<32s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1PPM\",\"valueZh\":\"1PPM\"}],\"description\":{\"en\":\"HH-X8C-20000 is an HH ndir infrared infrared sensor module for carbon dioxide, with range 0-20000PPM, output\/sensitivity UART, response time T90<32s.\",\"zh\":\"HH-X8C-20000 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-x8c-5000-21dbf64103a2.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-v1-1-1-e9880aa427b0.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:ndir-8205a-ch4-153\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"NDIR-8205A-CH4\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CH4\",\"gasName\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"0-100LEL \/ 0-100VOL\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<33s\",\"responseTimeZh\":\"T90<33s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01LEL \/ 0.01VOL\",\"resolutionZh\":\"0.01LEL \/ 0.01VOL\",\"voltage\":\"DC3.0~5.5V\",\"voltageZh\":\"DC3.0~5.5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100LEL \/ 0-100VOL\",\"valueZh\":\"0-100LEL \/ 0-100VOL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<33s\",\"valueZh\":\"T90<33s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01LEL \/ 0.01VOL\",\"valueZh\":\"0.01LEL \/ 0.01VOL\"}],\"description\":{\"en\":\"NDIR-8205A-CH4 is an HH ndir infrared infrared sensor module for methane, with range 0-100LEL \/ 0-100VOL, output\/sensitivity UART, response time T90<33s.\",\"zh\":\"NDIR-8205A-CH4 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u7532\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-ndir-8205a-ch4-bbc1cbee99e9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-v2-1-2740cfec76fe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:ndir-8205a-c3h8-154\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"NDIR-8205A-C3H8\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"C3H8\",\"gasName\":{\"en\":\"Propane\",\"zh\":\"\u4e19\u70f7\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"0-100LEL \/ 0-100VOL\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<34s\",\"responseTimeZh\":\"T90<34s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01LEL \/ 0.01VOL\",\"resolutionZh\":\"0.01LEL \/ 0.01VOL\",\"voltage\":\"DC3.0~5.5V\",\"voltageZh\":\"DC3.0~5.5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100LEL \/ 0-100VOL\",\"valueZh\":\"0-100LEL \/ 0-100VOL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<34s\",\"valueZh\":\"T90<34s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01LEL \/ 0.01VOL\",\"valueZh\":\"0.01LEL \/ 0.01VOL\"}],\"description\":{\"en\":\"NDIR-8205A-C3H8 is an HH ndir infrared infrared sensor module for propane, with range 0-100LEL \/ 0-100VOL, output\/sensitivity UART, response time T90<34s.\",\"zh\":\"NDIR-8205A-C3H8 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e19\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-ndir-8205a-ch4-bbc1cbee99e9.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-v2-1-2740cfec76fe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:ndir-8205a-c4h10-155\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"NDIR-8205A-C4H10\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"C4H10\",\"gasName\":{\"en\":\"Isobutane\",\"zh\":\"\u5f02\u4e01\u70f7\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"0-100LEL\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<35s\",\"responseTimeZh\":\"T90<35s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.01LEL \/ 0.01VOL\",\"resolutionZh\":\"0.01LEL \/ 0.01VOL\",\"voltage\":\"DC3.0~5.5V\",\"voltageZh\":\"DC3.0~5.5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-100LEL\",\"valueZh\":\"0-100LEL\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<35s\",\"valueZh\":\"T90<35s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.01LEL \/ 0.01VOL\",\"valueZh\":\"0.01LEL \/ 0.01VOL\"}],\"description\":{\"en\":\"NDIR-8205A-C4H10 is an HH ndir infrared infrared sensor module for isobutane, with range 0-100LEL, output\/sensitivity UART, response time T90<35s.\",\"zh\":\"NDIR-8205A-C4H10 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u5f02\u4e01\u70f7\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-ndir-8205a-c4h10-84bae41f9fa6.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-v2-1-2740cfec76fe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:ndir-8205b-co2-156\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"NDIR-8205B-CO2\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"CO2\",\"gasName\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"\u91cf\u7a0b\u53ef\u9009\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<36s\",\"responseTimeZh\":\"T90<36s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1PPM \/ 0.01VOL\",\"resolutionZh\":\"1PPM \/ 0.01VOL\",\"voltage\":\"DC3.0~5.5V\",\"voltageZh\":\"DC3.0~5.5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"\u91cf\u7a0b\u53ef\u9009\",\"valueZh\":\"\u91cf\u7a0b\u53ef\u9009\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<36s\",\"valueZh\":\"T90<36s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1PPM \/ 0.01VOL\",\"valueZh\":\"1PPM \/ 0.01VOL\"}],\"description\":{\"en\":\"NDIR-8205B-CO2 is an HH ndir infrared infrared sensor module for carbon dioxide, with range \u91cf\u7a0b\u53ef\u9009, output\/sensitivity UART, response time T90<36s.\",\"zh\":\"NDIR-8205B-CO2 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u4e8c\u6c27\u5316\u78b3\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-ndir-8205b-co2-0819243ff9de.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-v2-1-2740cfec76fe.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:d320-157\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"D320\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Infrared Sensor Module\",\"zh\":\"\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ndir-infrared\",\"series\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"SF6\",\"gasName\":{\"en\":\"Sulfur Hexafluoride\",\"zh\":\"\u516d\u6c1f\u5316\u786b\"},\"tech\":\"NDIR\",\"techName\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u7ea2\u5916\"},\"specs\":{\"range\":\"0-2000ppm\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<37s\",\"responseTimeZh\":\"T90<37s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1PPM\",\"resolutionZh\":\"1PPM\",\"voltage\":\"DC3.0~5.5V\",\"voltageZh\":\"DC3.0~5.5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-2000ppm\",\"valueZh\":\"0-2000ppm\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<37s\",\"valueZh\":\"T90<37s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1PPM\",\"valueZh\":\"1PPM\"}],\"description\":{\"en\":\"D320 is an HH ndir infrared infrared sensor module for sulfur hexafluoride, with range 0-2000ppm, output\/sensitivity UART, response time T90<37s.\",\"zh\":\"D320 \u662f\u534e\u6df1\u79d1\u7684NDIR \u7ea2\u5916\u7ea2\u5916\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u516d\u6c1f\u5316\u786b\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-d320-efffd42535e3.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-sw320-v1-3-6-26-fcfdb92ddd1e.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-d7-158\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-D7\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Particle Sensor\",\"zh\":\"\u9897\u7c92\u7269\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:optical-particle\",\"series\":{\"en\":\"Optical Particle Sensors\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\u4f20\u611f\u5668\"},\"gas\":\"PARTICULATE_MATTER\",\"gasName\":{\"en\":\"Particulate Matter\",\"zh\":\"\u7c89\u5c18\u9897\u7c92\u7269\"},\"tech\":\"OPTICAL_PARTICLE\",\"techName\":{\"en\":\"Optical Particle\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\"},\"specs\":{\"range\":\"PM1 PM2.5 PM10\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<38s\",\"responseTimeZh\":\"T90<38s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1\u03bcg \/ m\u00b3\",\"resolutionZh\":\"1\u03bcg \/ m\u00b3\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"PM1 PM2.5 PM10\",\"valueZh\":\"PM1 PM2.5 PM10\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<38s\",\"valueZh\":\"T90<38s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1\u03bcg \/ m\u00b3\",\"valueZh\":\"1\u03bcg \/ m\u00b3\"}],\"description\":{\"en\":\"HH-D7 is an HH optical particle particle sensor for particulate matter, with range PM1 PM2.5 PM10, output\/sensitivity UART, response time T90<38s.\",\"zh\":\"HH-D7 \u662f\u534e\u6df1\u79d1\u7684\u5149\u5b66\u9897\u7c92\u7269\u9897\u7c92\u7269\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7c89\u5c18\u9897\u7c92\u7269\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-d7-6b0766253e71.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-d7-pm2-5-a014377195f6.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-d9-159\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-D9\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Particle Sensor\",\"zh\":\"\u9897\u7c92\u7269\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:optical-particle\",\"series\":{\"en\":\"Optical Particle Sensors\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\u4f20\u611f\u5668\"},\"gas\":\"PARTICULATE_MATTER\",\"gasName\":{\"en\":\"Particulate Matter\",\"zh\":\"\u7c89\u5c18\u9897\u7c92\u7269\"},\"tech\":\"OPTICAL_PARTICLE\",\"techName\":{\"en\":\"Optical Particle\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\"},\"specs\":{\"range\":\"PM1 PM2.5 PM10\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<39s\",\"responseTimeZh\":\"T90<39s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"1\u03bcg \/ m\u00b3\",\"resolutionZh\":\"1\u03bcg \/ m\u00b3\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"PM1 PM2.5 PM10\",\"valueZh\":\"PM1 PM2.5 PM10\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<39s\",\"valueZh\":\"T90<39s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"1\u03bcg \/ m\u00b3\",\"valueZh\":\"1\u03bcg \/ m\u00b3\"}],\"description\":{\"en\":\"HH-D9 is an HH optical particle particle sensor for particulate matter, with range PM1 PM2.5 PM10, output\/sensitivity UART, response time T90<39s.\",\"zh\":\"HH-D9 \u662f\u534e\u6df1\u79d1\u7684\u5149\u5b66\u9897\u7c92\u7269\u9897\u7c92\u7269\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7c89\u5c18\u9897\u7c92\u7269\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-d9-798efc681b7c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-d9-pm2-5-a0c4775f9664.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:hh-x01-160\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-X01\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Particle Sensor\",\"zh\":\"\u9897\u7c92\u7269\u4f20\u611f\u5668\"},\"seriesKey\":\"hh:optical-particle\",\"series\":{\"en\":\"Optical Particle Sensors\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\u4f20\u611f\u5668\"},\"gas\":\"PARTICULATE_MATTER\",\"gasName\":{\"en\":\"Particulate Matter\",\"zh\":\"\u7c89\u5c18\u9897\u7c92\u7269\"},\"tech\":\"OPTICAL_PARTICLE\",\"techName\":{\"en\":\"Optical Particle\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\"},\"specs\":{\"range\":\"PM2.5\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"T90<40s\",\"responseTimeZh\":\"T90<40s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"\u00b120ug \/ m\u00b3\",\"resolutionZh\":\"\u00b120ug \/ m\u00b3\",\"voltage\":\"5V\",\"voltageZh\":\"5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"PM2.5\",\"valueZh\":\"PM2.5\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"T90<40s\",\"valueZh\":\"T90<40s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"\u00b120ug \/ m\u00b3\",\"valueZh\":\"\u00b120ug \/ m\u00b3\"}],\"description\":{\"en\":\"HH-X01 is an HH optical particle particle sensor for particulate matter, with range PM2.5, output\/sensitivity UART, response time T90<40s.\",\"zh\":\"HH-X01 \u662f\u534e\u6df1\u79d1\u7684\u5149\u5b66\u9897\u7c92\u7269\u9897\u7c92\u7269\u4f20\u611f\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u7c89\u5c18\u9897\u7c92\u7269\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-x01-03e037b9d65f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh-x01-24ca411a3c33.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true},{\"id\":\"hh:4mz-hh-sht30-161\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"4MZ-HH-\u6e29\u6e7f\u5ea6\uff08SHT30\uff09\",\"partNumber\":\"\",\"productClass\":\"SENSOR_MODULE\",\"productClassName\":{\"en\":\"Environmental Sensor Module\",\"zh\":\"\u73af\u5883\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:digital-environmental\",\"series\":{\"en\":\"Temperature &#038; Humidity Modules\",\"zh\":\"\u6e29\u6e7f\u5ea6\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"},\"gas\":\"TEMPERATURE_HUMIDITY\",\"gasName\":{\"en\":\"Temperature and Humidity\",\"zh\":\"\u6e29\u6e7f\u5ea6\"},\"tech\":\"DIGITAL_ENVIRONMENTAL\",\"techName\":{\"en\":\"Digital Environmental\",\"zh\":\"\u6570\u5b57\u73af\u5883\"},\"specs\":{\"range\":\"0-125\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"<30s\",\"responseTimeZh\":\"<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1\",\"resolutionZh\":\"0.1\",\"voltage\":\"3.7V-5V\",\"voltageZh\":\"3.7V-5V\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"0-125\",\"valueZh\":\"0-125\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30s\",\"valueZh\":\"<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1\",\"valueZh\":\"0.1\"}],\"description\":{\"en\":\"4MZ-HH-\u6e29\u6e7f\u5ea6\uff08SHT30\uff09 is an HH digital environmental environmental sensor module for temperature and humidity, with range 0-125, output\/sensitivity UART, response time <30s.\",\"zh\":\"4MZ-HH-\u6e29\u6e7f\u5ea6\uff08SHT30\uff09 \u662f\u534e\u6df1\u79d1\u7684\u6570\u5b57\u73af\u5883\u73af\u5883\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6e29\u6e7f\u5ea6\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-4mz-hh-sht30-b2f56308196c.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-4mz-hh-v1-3-b41abdcb4116.pdf\",\"match\":\"reference\"}],\"embeddedDetails\":true,\"documentNote\":{\"en\":\"Official series or handbook reference; verify model applicability before final use.\",\"zh\":\"\u5b98\u65b9\u7cfb\u5217\u8d44\u6599\u6216\u4ea7\u54c1\u624b\u518c\uff0c\u6700\u7ec8\u4f7f\u7528\u524d\u8bf7\u590d\u6838\u578b\u53f7\u9002\u7528\u6027\u3002\"}},{\"id\":\"hh:hh-4000-162\",\"brandKey\":\"hh\",\"brandName\":\"HH\",\"model\":\"HH-4000\",\"partNumber\":\"\",\"productClass\":\"SENSOR_DEVICE\",\"productClassName\":{\"en\":\"Oxygen Sensor Module\",\"zh\":\"\u6c27\u6c14\u4f20\u611f\u5668\u6a21\u7ec4\"},\"seriesKey\":\"hh:ultrasonic\",\"series\":{\"en\":\"Ultrasonic Oxygen Sensors\",\"zh\":\"\u8d85\u58f0\u6ce2\u6c27\u6c14\u4f20\u611f\u5668\"},\"gas\":\"O2\",\"gasName\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"},\"tech\":\"ULTRASONIC\",\"techName\":{\"en\":\"Ultrasonic\",\"zh\":\"\u8d85\u58f0\u6ce2\"},\"specs\":{\"range\":\"21%~95.6%\",\"sensitivity\":\"UART\",\"signal\":\"UART\",\"signalZh\":\"UART\",\"responseTime\":\"<30s\",\"responseTimeZh\":\"<30s\",\"responseLabel\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"resolution\":\"0.1%VOL\",\"resolutionZh\":\"0.1%VOL\",\"voltage\":\"5V \u6216 12V \u53ef\u9009\",\"voltageZh\":\"5V \u6216 12V \u53ef\u9009\",\"accuracy\":\"\u00b12%FS@(5~55\u2103)\",\"accuracyZh\":\"\u00b12%FS@(5~55\u2103)\"},\"specRows\":[{\"key\":\"range\",\"label\":{\"en\":\"Range\",\"zh\":\"\u91cf\u7a0b\"},\"value\":\"21%~95.6%\",\"valueZh\":\"21%~95.6%\"},{\"key\":\"signal\",\"label\":{\"en\":\"Output Signal \/ Sensitivity\",\"zh\":\"\u8f93\u51fa\u4fe1\u53f7 \/ \u7075\u654f\u5ea6\"},\"value\":\"UART\",\"valueZh\":\"UART\"},{\"key\":\"responseTime\",\"label\":{\"en\":\"Response Time\",\"zh\":\"\u54cd\u5e94\u65f6\u95f4\"},\"value\":\"<30s\",\"valueZh\":\"<30s\"},{\"key\":\"resolution\",\"label\":{\"en\":\"Resolution\",\"zh\":\"\u5206\u8fa8\u7387\"},\"value\":\"0.1%VOL\",\"valueZh\":\"0.1%VOL\"}],\"description\":{\"en\":\"HH-4000 is an HH ultrasonic oxygen sensor module for oxygen, with range 21%~95.6%, output\/sensitivity UART, response time <30s.\",\"zh\":\"HH-4000 \u662f\u534e\u6df1\u79d1\u7684\u8d85\u58f0\u6ce2\u6c27\u6c14\u4f20\u611f\u5668\u6a21\u7ec4\uff0c\u7528\u4e8e\u68c0\u6d4b\u6c27\u6c14\u3002\"},\"imageUrl\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/images\/hh-hh-4000-d34e0fd07d7f.webp\",\"documents\":[{\"kind\":\"datasheet\",\"lang\":\"zh\",\"url\":\"https:\/\/airmate.cc\/wp-content\/uploads\/airmate-sensor-library\/hh\/documents\/hh-hh4000-v1-5-5da191c2e8e2.pdf\",\"match\":\"exact\"}],\"embeddedDetails\":true}],\"brands\":[{\"key\":\"semeatech\",\"name\":\"SemeaTech\",\"order\":10,\"count\":284},{\"key\":\"membrapor\",\"name\":\"Membrapor\",\"order\":20,\"count\":278},{\"key\":\"alphasense\",\"name\":\"Alphasense\",\"order\":30,\"count\":113},{\"key\":\"nemoto\",\"name\":\"Nemoto\",\"order\":40,\"count\":51},{\"key\":\"honeywell\",\"name\":\"Honeywell\",\"order\":50,\"count\":66},{\"key\":\"city\",\"name\":\"City Technology\",\"order\":60,\"count\":186},{\"key\":\"figaro\",\"name\":\"Figaro\",\"order\":70,\"count\":42},{\"key\":\"ecsense\",\"name\":\"EC Sense\",\"order\":80,\"count\":299},{\"key\":\"sgx\",\"name\":\"SGX Sensortech\",\"order\":90,\"count\":7},{\"key\":\"susa\",\"name\":\"SUSA\",\"order\":100,\"count\":71},{\"key\":\"hh\",\"name\":\"HH\",\"order\":110,\"count\":109}],\"gases\":[{\"key\":\"ACETONE\",\"labels\":{\"en\":\"Acetone\",\"zh\":\"\u4e19\u916e\"}},{\"key\":\"AIR_QUALITY\",\"labels\":{\"en\":\"Air Quality\",\"zh\":\"\u7a7a\u6c14\u8d28\u91cf\u7efc\u5408\"}},{\"key\":\"ASH3\",\"labels\":{\"en\":\"Arsine\",\"zh\":\"\u7837\u5316\u6c22\"}},{\"key\":\"B2H6\",\"labels\":{\"en\":\"Diborane\",\"zh\":\"\u4e59\u787c\u70f7\"}},{\"key\":\"BR2\",\"labels\":{\"en\":\"Bromine\",\"zh\":\"\u6eb4\u6c14\"}},{\"key\":\"C2H2\",\"labels\":{\"en\":\"Acetylene\",\"zh\":\"\u4e59\u7094\"}},{\"key\":\"C2H3CL\",\"labels\":{\"en\":\"Vinyl Chloride\",\"zh\":\"\u6c2f\u4e59\u70ef\"}},{\"key\":\"C2H4\",\"labels\":{\"en\":\"Ethylene\",\"zh\":\"\u4e59\u70ef\"}},{\"key\":\"C3H3N\",\"labels\":{\"en\":\"Acrylonitrile\",\"zh\":\"\u4e19\u70ef\u8148\"}},{\"key\":\"CH2O\",\"labels\":{\"en\":\"Formaldehyde\",\"zh\":\"\u7532\u919b\"}},{\"key\":\"CH3SH\",\"labels\":{\"en\":\"Methanethiol\",\"zh\":\"\u7532\u786b\u9187\"}},{\"key\":\"CH4\",\"labels\":{\"en\":\"Methane\",\"zh\":\"\u7532\u70f7\"}},{\"key\":\"CH4_CO\",\"labels\":{\"en\":\"Methane \/ Carbon Monoxide\",\"zh\":\"\u7532\u70f7 \/ \u4e00\u6c27\u5316\u78b3\"}},{\"key\":\"CL2\",\"labels\":{\"en\":\"Chlorine\",\"zh\":\"\u6c2f\u6c14\"}},{\"key\":\"CLO2\",\"labels\":{\"en\":\"Chlorine Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2f\"}},{\"key\":\"CO\",\"labels\":{\"en\":\"Carbon Monoxide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3\"}},{\"key\":\"CO_H2S\",\"labels\":{\"en\":\"Carbon Monoxide \/ Hydrogen Sulfide\",\"zh\":\"\u4e00\u6c27\u5316\u78b3 \/ \u786b\u5316\u6c22\"}},{\"key\":\"CO2\",\"labels\":{\"en\":\"Carbon Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u78b3\"}},{\"key\":\"COCL2\",\"labels\":{\"en\":\"Phosgene\",\"zh\":\"\u5149\u6c14\"}},{\"key\":\"COMBUSTION_EXHAUST\",\"labels\":{\"en\":\"Incomplete Combustion Exhaust Gas\",\"zh\":\"\u4e0d\u5b8c\u5168\u71c3\u70e7\u5e9f\u6c14\"}},{\"key\":\"CS2\",\"labels\":{\"en\":\"Carbon Disulfide\",\"zh\":\"\u4e8c\u786b\u5316\u78b3\"}},{\"key\":\"DUAL_GAS\",\"labels\":{\"en\":\"Dual Gas\",\"zh\":\"\u53cc\u6c14\u4f53\"}},{\"key\":\"ETO\",\"labels\":{\"en\":\"Ethylene Oxide\",\"zh\":\"\u73af\u6c27\u4e59\u70f7\"}},{\"key\":\"F2\",\"labels\":{\"en\":\"Fluorine\",\"zh\":\"\u6c1f\u6c14\"}},{\"key\":\"GEH4\",\"labels\":{\"en\":\"Germane\",\"zh\":\"\u9517\u70f7\"}},{\"key\":\"H2\",\"labels\":{\"en\":\"Hydrogen\",\"zh\":\"\u6c22\u6c14\"}},{\"key\":\"H2O2\",\"labels\":{\"en\":\"Hydrogen Peroxide\",\"zh\":\"\u8fc7\u6c27\u5316\u6c22\"}},{\"key\":\"H2S\",\"labels\":{\"en\":\"Hydrogen Sulfide\",\"zh\":\"\u786b\u5316\u6c22\"}},{\"key\":\"H2S_SO2\",\"labels\":{\"en\":\"Hydrogen Sulfide \/ Sulfur Dioxide\",\"zh\":\"\u786b\u5316\u6c22 \/ \u4e8c\u6c27\u5316\u786b\"}},{\"key\":\"H2SE\",\"labels\":{\"en\":\"Hydrogen Selenide\",\"zh\":\"\u7852\u5316\u6c22\"}},{\"key\":\"HBR\",\"labels\":{\"en\":\"Hydrogen Bromide\",\"zh\":\"\u6eb4\u5316\u6c22\"}},{\"key\":\"HCL\",\"labels\":{\"en\":\"Hydrogen Chloride\",\"zh\":\"\u6c2f\u5316\u6c22\"}},{\"key\":\"HCL_HBR\",\"labels\":{\"en\":\"Hydrogen Chloride \/ Hydrogen Bromide\",\"zh\":\"\u6c2f\u5316\u6c22 \/ \u6eb4\u5316\u6c22\"}},{\"key\":\"HCN\",\"labels\":{\"en\":\"Hydrogen Cyanide\",\"zh\":\"\u6c30\u5316\u6c22\"}},{\"key\":\"HF\",\"labels\":{\"en\":\"Hydrogen Fluoride\",\"zh\":\"\u6c1f\u5316\u6c22\"}},{\"key\":\"IR_DETECTOR\",\"labels\":{\"en\":\"Infrared Detector Element\",\"zh\":\"\u7ea2\u5916\u63a2\u6d4b\u5143\u4ef6\"}},{\"key\":\"LEL\",\"labels\":{\"en\":\"Combustible Gas\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53\"}},{\"key\":\"LEL_CH4\",\"labels\":{\"en\":\"LEL\/Methane (LEL\/CH4)\",\"zh\":\"\u53ef\u71c3\u6c14\u4f53 \/ \u7532\u70f7\uff08LEL\uff09\"}},{\"key\":\"LPG\",\"labels\":{\"en\":\"LP Gas\",\"zh\":\"\u6db2\u5316\u77f3\u6cb9\u6c14\"}},{\"key\":\"MERCAPTAN\",\"labels\":{\"en\":\"Mercaptan\",\"zh\":\"\u786b\u9187\"}},{\"key\":\"MULTI_GAS\",\"labels\":{\"en\":\"Multiple Gases\",\"zh\":\"\u591a\u6c14\u4f53\"}},{\"key\":\"N2H4\",\"labels\":{\"en\":\"Hydrazine\",\"zh\":\"\u80bc\"}},{\"key\":\"NH3\",\"labels\":{\"en\":\"Ammonia\",\"zh\":\"\u6c28\u6c14\"}},{\"key\":\"NO\",\"labels\":{\"en\":\"Nitric Oxide\",\"zh\":\"\u4e00\u6c27\u5316\u6c2e\"}},{\"key\":\"NO2\",\"labels\":{\"en\":\"Nitrogen Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u6c2e\"}},{\"key\":\"O2\",\"labels\":{\"en\":\"Oxygen\",\"zh\":\"\u6c27\u6c14\"}},{\"key\":\"O3\",\"labels\":{\"en\":\"Ozone\",\"zh\":\"\u81ed\u6c27\"}},{\"key\":\"PH3\",\"labels\":{\"en\":\"Phosphine\",\"zh\":\"\u78f7\u5316\u6c22\"}},{\"key\":\"PM\",\"labels\":{\"en\":\"Particulate Matter\",\"zh\":\"\u9897\u7c92\u7269\"}},{\"key\":\"R32\",\"labels\":{\"en\":\"R-32 Refrigerant\",\"zh\":\"R-32 \u5236\u51b7\u5242\"}},{\"key\":\"R3COH\",\"labels\":{\"en\":\"Alcohols\",\"zh\":\"\u9187\u7c7b\"}},{\"key\":\"RCOOH\",\"labels\":{\"en\":\"Organic Acids\",\"zh\":\"\u6709\u673a\u9178\"}},{\"key\":\"REFRIGERANT\",\"labels\":{\"en\":\"Refrigerant Gas\",\"zh\":\"\u5236\u51b7\u5242\u6c14\u4f53\"}},{\"key\":\"SIH4\",\"labels\":{\"en\":\"Silane\",\"zh\":\"\u7845\u70f7\"}},{\"key\":\"SMELL\",\"labels\":{\"en\":\"Odor \/ Smell\",\"zh\":\"\u5f02\u5473\"}},{\"key\":\"SO2\",\"labels\":{\"en\":\"Sulfur Dioxide\",\"zh\":\"\u4e8c\u6c27\u5316\u786b\"}},{\"key\":\"T_RH\",\"labels\":{\"en\":\"Temperature, Humidity\",\"zh\":\"\u6e29\u5ea6 \/ \u76f8\u5bf9\u6e7f\u5ea6\"}},{\"key\":\"T_RH_P\",\"labels\":{\"en\":\"Temperature, Pressure, Humidity\",\"zh\":\"\u6e29\u5ea6 \/ \u76f8\u5bf9\u6e7f\u5ea6 \/ \u6c14\u538b\"}},{\"key\":\"TEOS\",\"labels\":{\"en\":\"Tetraethyl Orthosilicate\",\"zh\":\"\u6b63\u7845\u9178\u4e59\u916f\"}},{\"key\":\"THT\",\"labels\":{\"en\":\"Tetrahydrothiophene\",\"zh\":\"\u56db\u6c22\u567b\u5429\"}},{\"key\":\"VOC\",\"labels\":{\"en\":\"Volatile Organic Compounds\",\"zh\":\"\u6325\u53d1\u6027\u6709\u673a\u7269\"}}],\"technologies\":[{\"key\":\"CATALYTIC\",\"labels\":{\"en\":\"Catalytic Combustion\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\"}},{\"key\":\"DIGITAL_ENVIRONMENTAL\",\"labels\":{\"en\":\"Digital Environmental\",\"zh\":\"\u6570\u5b57\u73af\u5883\u68c0\u6d4b\"}},{\"key\":\"ELECTROCHEMICAL\",\"labels\":{\"en\":\"Electrochemical\",\"zh\":\"\u7535\u5316\u5b66\"}},{\"key\":\"MOS\",\"labels\":{\"en\":\"Metal Oxide Semiconductor (MOS)\",\"zh\":\"\u91d1\u5c5e\u6c27\u5316\u7269\u534a\u5bfc\u4f53\uff08MOS\uff09\"}},{\"key\":\"NDIR\",\"labels\":{\"en\":\"NDIR Infrared\",\"zh\":\"NDIR \u975e\u5206\u5149\u7ea2\u5916\"}},{\"key\":\"OPTICAL_PARTICLE\",\"labels\":{\"en\":\"Optical Particle Counting\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\u68c0\u6d4b\"}},{\"key\":\"PID\",\"labels\":{\"en\":\"PID Photoionization\",\"zh\":\"PID \u5149\u79bb\u5b50\u68c0\u6d4b\"}},{\"key\":\"THERMAL_CONDUCTIVITY\",\"labels\":{\"en\":\"Thermal Conductivity\",\"zh\":\"\u70ed\u4f20\u5bfc\u5f0f\"}},{\"key\":\"THERMOPILE\",\"labels\":{\"en\":\"Infrared Thermopile\",\"zh\":\"\u7ea2\u5916\u70ed\u7535\u5806\"}}],\"series\":[{\"key\":\"semeatech:3-720be4f0\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"3 Series\",\"zh\":\"3\u7cfb\u5217\"}},{\"key\":\"semeatech:4-945a8221\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"4 Series\",\"zh\":\"4\u7cfb\u5217\"}},{\"key\":\"semeatech:4-pid-d9776957\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"4 Series PID\",\"zh\":\"4\u7cfb\u5217PID\"}},{\"key\":\"semeatech:4-pid-plus-7a3d9fbd\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"4 Series PID Plus\",\"zh\":\"4\u7cfb\u5217PID Plus\"}},{\"key\":\"semeatech:4sm-d02522fc\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"4SM Process Gas\",\"zh\":\"4SM\u5236\u7a0b\u6c14\u4f53\"}},{\"key\":\"semeatech:7-d228187f\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"7 Series\",\"zh\":\"7\u7cfb\u5217\"}},{\"key\":\"semeatech:7-pid-7734bbbd\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"7 Series PID\",\"zh\":\"7\u7cfb\u5217PID\"}},{\"key\":\"semeatech:item-bda9deb8\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"Consumer Sensors\",\"zh\":\"\u6c11\u7528\u4f20\u611f\u5668\"}},{\"key\":\"semeatech:3-076a68d5\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"Environmental Monitoring - 3-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-3\u7535\u6781\"}},{\"key\":\"semeatech:4-0f4cc5a1\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"Environmental Monitoring - 4-electrode\",\"zh\":\"\u73af\u5883\u76d1\u6d4b\u7ea7-4\u7535\u6781\"}},{\"key\":\"semeatech:mini-4067e3db\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"Mini Series\",\"zh\":\"mini\u7cfb\u5217\"}},{\"key\":\"semeatech:ndir-lel-2354ce12\",\"brandKey\":\"semeatech\",\"labels\":{\"en\":\"NDIR &#038; LEL\",\"zh\":\"NDIR\u548cLEL\"}},{\"key\":\"membrapor:compact-gas-sensors-dd2f6e62\",\"brandKey\":\"membrapor\",\"labels\":{\"en\":\"Compact Gas Sensors\",\"zh\":\"\u7d27\u51d1\u578b\u6c14\u4f53\u4f20\u611f\u5668\"}},{\"key\":\"membrapor:miniature-gas-sensors-b5b95407\",\"brandKey\":\"membrapor\",\"labels\":{\"en\":\"Miniature Gas Sensors\",\"zh\":\"\u5fae\u578b\u6c14\u4f53\u4f20\u611f\u5668\"}},{\"key\":\"membrapor:non-dispersive-infrared-sensors-ndir-54b2597e\",\"brandKey\":\"membrapor\",\"labels\":{\"en\":\"Non-Dispersive Infrared Sensors (NDIR)\",\"zh\":\"\u975e\u5206\u5149\u7ea2\u5916\u4f20\u611f\u5668\uff08NDIR\uff09\"}},{\"key\":\"membrapor:oxygen-sensors-0a8104eb\",\"brandKey\":\"membrapor\",\"labels\":{\"en\":\"Oxygen Sensors\",\"zh\":\"\u6c27\u6c14\u4f20\u611f\u5668\"}},{\"key\":\"membrapor:slim-gas-sensors-ab11493e\",\"brandKey\":\"membrapor\",\"labels\":{\"en\":\"Slim Gas Sensors\",\"zh\":\"\u8d85\u8584\u578b\u6c14\u4f53\u4f20\u611f\u5668\"}},{\"key\":\"membrapor:standard-gas-sensors-b03c2f91\",\"brandKey\":\"membrapor\",\"labels\":{\"en\":\"Standard Gas Sensors\",\"zh\":\"\u6807\u51c6\u578b\u6c14\u4f53\u4f20\u611f\u5668\"}},{\"key\":\"membrapor:vantage-gas-sensors-1133c452\",\"brandKey\":\"membrapor\",\"labels\":{\"en\":\"Vantage Gas Sensors\",\"zh\":\"Vantage \u6c14\u4f53\u4f20\u611f\u5668\"}},{\"key\":\"alphasense:a-series\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"A Series\",\"zh\":\"A \u7cfb\u5217\"}},{\"key\":\"alphasense:b-series\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"B Series\",\"zh\":\"B \u7cfb\u5217\"}},{\"key\":\"alphasense:d-series\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"D Series\",\"zh\":\"D \u7cfb\u5217\"}},{\"key\":\"alphasense:h-series\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"H Series\",\"zh\":\"H \u7cfb\u5217\"}},{\"key\":\"alphasense:c-series\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"C Series\",\"zh\":\"C \u7cfb\u5217\"}},{\"key\":\"alphasense:g-series\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"G Series\",\"zh\":\"G \u7cfb\u5217\"}},{\"key\":\"alphasense:n3\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"N3 Optical Particle Counter\",\"zh\":\"N3 \u5149\u5b66\u9897\u7c92\u7269\u8ba1\u6570\u5668\"}},{\"key\":\"alphasense:r2\",\"brandKey\":\"alphasense\",\"labels\":{\"en\":\"R2 Optical Particle Counter\",\"zh\":\"R2 \u5149\u5b66\u9897\u7c92\u7269\u8ba1\u6570\u5668\"}},{\"key\":\"nemoto:ncp-dbe60238\",\"brandKey\":\"nemoto\",\"labels\":{\"en\":\"NCP\",\"zh\":\"NCP\"}},{\"key\":\"nemoto:ne4-7255d757\",\"brandKey\":\"nemoto\",\"labels\":{\"en\":\"NE4\",\"zh\":\"NE4\"}},{\"key\":\"nemoto:nap-82ebadaf\",\"brandKey\":\"nemoto\",\"labels\":{\"en\":\"NAP\",\"zh\":\"NAP\"}},{\"key\":\"nemoto:ne7-d51ecd13\",\"brandKey\":\"nemoto\",\"labels\":{\"en\":\"NE7\",\"zh\":\"NE7\"}},{\"key\":\"nemoto:nch-6be0d417\",\"brandKey\":\"nemoto\",\"labels\":{\"en\":\"NCH\",\"zh\":\"NCH\"}},{\"key\":\"nemoto:nsu-9db2f9c8\",\"brandKey\":\"nemoto\",\"labels\":{\"en\":\"NSU\",\"zh\":\"NSU\"}},{\"key\":\"city:1-series\",\"brandKey\":\"city\",\"labels\":{\"en\":\"1 Series\",\"zh\":\"1 \u7cfb\u5217\"}},{\"key\":\"city:3-series\",\"brandKey\":\"city\",\"labels\":{\"en\":\"3 Series\",\"zh\":\"3 \u7cfb\u5217\"}},{\"key\":\"city:4-series\",\"brandKey\":\"city\",\"labels\":{\"en\":\"4 Series\",\"zh\":\"4 \u7cfb\u5217\"}},{\"key\":\"city:5-series\",\"brandKey\":\"city\",\"labels\":{\"en\":\"5 Series\",\"zh\":\"5 \u7cfb\u5217\"}},{\"key\":\"city:7-series\",\"brandKey\":\"city\",\"labels\":{\"en\":\"7 Series\",\"zh\":\"7 \u7cfb\u5217\"}},{\"key\":\"city:i-series\",\"brandKey\":\"city\",\"labels\":{\"en\":\"i Series\",\"zh\":\"i \u7cfb\u5217\"}},{\"key\":\"city:microcel-micropel\",\"brandKey\":\"city\",\"labels\":{\"en\":\"MICROceL \/ MICROpeL\",\"zh\":\"MICROceL \/ MICROpeL\"}},{\"key\":\"city:sensoric\",\"brandKey\":\"city\",\"labels\":{\"en\":\"SensoriC\",\"zh\":\"SensoriC \u7cfb\u5217\"}},{\"key\":\"honeywell:4r-pid\",\"brandKey\":\"honeywell\",\"labels\":{\"en\":\"4R PID\",\"zh\":\"4R PID\"}},{\"key\":\"honeywell:aq7\",\"brandKey\":\"honeywell\",\"labels\":{\"en\":\"AQ7\",\"zh\":\"AQ7\"}},{\"key\":\"honeywell:aq7-pid\",\"brandKey\":\"honeywell\",\"labels\":{\"en\":\"AQ7 PID\",\"zh\":\"AQ7 PID\"}},{\"key\":\"honeywell:s-series\",\"brandKey\":\"honeywell\",\"labels\":{\"en\":\"S Series\",\"zh\":\"S \u7cfb\u5217\"}},{\"key\":\"city:automotive-emissions\",\"brandKey\":\"city\",\"labels\":{\"en\":\"Automotive &#038; Emissions\",\"zh\":\"\u6c7d\u8f66\u4e0e\u6392\u653e\"}},{\"key\":\"figaro:cdm\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"CDM CO\u2082 Module\",\"zh\":\"CDM \u4e8c\u6c27\u5316\u78b3\u6a21\u7ec4\"}},{\"key\":\"figaro:cgm\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"CGM Combustible Gas Module\",\"zh\":\"CGM \u53ef\u71c3\u6c14\u4f53\u6a21\u7ec4\"}},{\"key\":\"figaro:cmm\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"CMM CO Module\",\"zh\":\"CMM \u4e00\u6c27\u5316\u78b3\u6a21\u7ec4\"}},{\"key\":\"figaro:fcm\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"FCM Refrigerant Gas Module\",\"zh\":\"FCM \u5236\u51b7\u5242\u6c14\u4f53\u6a21\u7ec4\"}},{\"key\":\"figaro:fecs\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"FECS Series\",\"zh\":\"FECS \u7cfb\u5217\"}},{\"key\":\"figaro:ke-lf\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"KE-LF Oxygen Series\",\"zh\":\"KE-LF \u6c27\u6c14\u7cfb\u5217\"}},{\"key\":\"figaro:lpm\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"LPM LP Gas Module\",\"zh\":\"LPM \u6db2\u5316\u6c14\u6a21\u7ec4\"}},{\"key\":\"figaro:ngm\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"NGM Natural Gas Module\",\"zh\":\"NGM \u5929\u7136\u6c14\u6a21\u7ec4\"}},{\"key\":\"figaro:tgs-catalytic\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"TGS Catalytic Series\",\"zh\":\"TGS \u50ac\u5316\u71c3\u70e7\u7cfb\u5217\"}},{\"key\":\"figaro:tgs-electrochemical\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"TGS Electrochemical Series\",\"zh\":\"TGS \u7535\u5316\u5b66\u7cfb\u5217\"}},{\"key\":\"figaro:tgs-mos\",\"brandKey\":\"figaro\",\"labels\":{\"en\":\"TGS MOS Series\",\"zh\":\"TGS MOS \u7cfb\u5217\"}},{\"key\":\"ecsense:dgm10\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"DGM10 Dual-Gas Modules\",\"zh\":\"DGM10 \u53cc\u6c14\u4f53\u6a21\u5757\"}},{\"key\":\"ecsense:ds4\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"DS4 Digital Sensor Modules\",\"zh\":\"DS4 \u6570\u5b57\u4f20\u611f\u5668\u6a21\u5757\"}},{\"key\":\"ecsense:ec4\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"EC4 Liquid-Electrolyte Series\",\"zh\":\"EC4 \u6db2\u6001\u7535\u89e3\u8d28\u7cfb\u5217\"}},{\"key\":\"ecsense:ecgaspoint\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"ECgaspoint Wireless Devices\",\"zh\":\"ECgaspoint \u65e0\u7ebf\u68c0\u6d4b\u8bbe\u5907\"}},{\"key\":\"ecsense:ecnose\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"ECnose Portable IAQ Devices\",\"zh\":\"ECnose \u4fbf\u643a\u5f0f\u7a7a\u6c14\u8d28\u91cf\u8bbe\u5907\"}},{\"key\":\"ecsense:ectox\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"ECtox Ammonia Devices\",\"zh\":\"ECtox \u6c28\u6c14\u68c0\u6d4b\u8bbe\u5907\"}},{\"key\":\"ecsense:es1\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"ES1 Solid-Polymer Miniature Series\",\"zh\":\"ES1 \u56fa\u4f53\u805a\u5408\u7269\u5fae\u578b\u7cfb\u5217\"}},{\"key\":\"ecsense:es4\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"ES4 Solid-Polymer 4-Series\",\"zh\":\"ES4 \u56fa\u4f53\u805a\u5408\u7269\u56db\u7cfb\u5217\"}},{\"key\":\"ecsense:stox\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"Stox Smart Gas Transmitters\",\"zh\":\"Stox \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"}},{\"key\":\"ecsense:stoxpro\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"StoxPro Smart Gas Transmitters\",\"zh\":\"StoxPro \u667a\u80fd\u6c14\u4f53\u53d8\u9001\u5668\"}},{\"key\":\"ecsense:tb200b\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"TB200B Smart Sensor Modules\",\"zh\":\"TB200B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"}},{\"key\":\"ecsense:tb420\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"TB420 4-20 mA Sensor Modules\",\"zh\":\"TB420 4-20 mA \u4f20\u611f\u5668\u6a21\u5757\"}},{\"key\":\"ecsense:tb600b\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"TB600B Smart Sensor Modules\",\"zh\":\"TB600B \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"}},{\"key\":\"ecsense:tb600c\",\"brandKey\":\"ecsense\",\"labels\":{\"en\":\"TB600C Smart Sensor Modules\",\"zh\":\"TB600C \u667a\u80fd\u4f20\u611f\u5668\u6a21\u5757\"}},{\"key\":\"sgx:4-series-electrochemical\",\"brandKey\":\"sgx\",\"labels\":{\"en\":\"4-Series Electrochemical Sensors\",\"zh\":\"\u56db\u7cfb\u5217\u7535\u5316\u5b66\u4f20\u611f\u5668\"}},{\"key\":\"sgx:7-series-air-quality\",\"brandKey\":\"sgx\",\"labels\":{\"en\":\"7-Series Air Quality Sensors\",\"zh\":\"\u4e03\u7cfb\u5217\u7a7a\u6c14\u8d28\u91cf\u4f20\u611f\u5668\"}},{\"key\":\"susa:electrochemical\",\"brandKey\":\"susa\",\"labels\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"}},{\"key\":\"susa:pid-photoionization\",\"brandKey\":\"susa\",\"labels\":{\"en\":\"PID Photoionization Sensors\",\"zh\":\"PID \u5149\u79bb\u5b50\u5316\u4f20\u611f\u5668\"}},{\"key\":\"susa:catalytic-combustion\",\"brandKey\":\"susa\",\"labels\":{\"en\":\"Catalytic Combustion Sensors\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\"}},{\"key\":\"hh:electrochemical-sensors\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"Electrochemical Gas Sensors\",\"zh\":\"\u7535\u5316\u5b66\u6c14\u4f53\u4f20\u611f\u5668\"}},{\"key\":\"hh:mos-semiconductor\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"Semiconductor Sensors &#038; Modules\",\"zh\":\"\u534a\u5bfc\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"}},{\"key\":\"hh:catalytic-combustion\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"Catalytic Sensors &#038; Modules\",\"zh\":\"\u50ac\u5316\u71c3\u70e7\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"}},{\"key\":\"hh:electrochemical-modules\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"Electrochemical Sensor Modules\",\"zh\":\"\u7535\u5316\u5b66\u4f20\u611f\u5668\u6a21\u7ec4\"}},{\"key\":\"hh:ndir-infrared\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"NDIR Gas Sensors &#038; Modules\",\"zh\":\"NDIR \u6c14\u4f53\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"}},{\"key\":\"hh:optical-particle\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"Optical Particle Sensors\",\"zh\":\"\u5149\u5b66\u9897\u7c92\u7269\u4f20\u611f\u5668\"}},{\"key\":\"hh:digital-environmental\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"Temperature &#038; Humidity Modules\",\"zh\":\"\u6e29\u6e7f\u5ea6\u4f20\u611f\u5668\u53ca\u6a21\u7ec4\"}},{\"key\":\"hh:ultrasonic\",\"brandKey\":\"hh\",\"labels\":{\"en\":\"Ultrasonic Oxygen Sensors\",\"zh\":\"\u8d85\u58f0\u6ce2\u6c27\u6c14\u4f20\u611f\u5668\"}}],\"perPage\":24}<\/script>\n<script>(function(){\"use strict\";var root=document.getElementById(\"sensor-library\"),node=document.getElementById(\"sl-catalog-data\");if(!root||!node)return;var data=JSON.parse(node.textContent),search=root.querySelector(\"#sl-search\"),brand=root.querySelector(\"#sl-brand\"),gas=root.querySelector(\"#sl-gas\"),tech=root.querySelector(\"#sl-tech\"),series=root.querySelector(\"#sl-series\"),grid=root.querySelector(\"#sl-grid\"),count=root.querySelector(\"#sl-count\"),pageLabel=root.querySelector(\"#sl-page-label\"),pageText=root.querySelector(\"#sl-page\"),prev=root.querySelector(\"#sl-prev\"),next=root.querySelector(\"#sl-next\"),empty=root.querySelector(\"#sl-empty\"),dialog=root.querySelector(\"#sl-details-dialog\"),dialogTitle=root.querySelector(\"#sl-dialog-title\"),dialogKicker=root.querySelector(\"#sl-dialog-kicker\"),dialogBody=root.querySelector(\"#sl-dialog-body\"),dialogClose=root.querySelector(\"#sl-dialog-close\"),lastDetailsTrigger=null,activeDetailsProduct=null,page=1,matched=[],isZh=false,lastLanguage=\"\",brandZh={semeatech:\"\u76db\u5bc6\",membrapor:\"\u8499\u5df4\u6ce2\",alphasense:\"\u963f\u5c14\u6cd5\",nemoto:\"\u65e5\u672c\u6839\u672c\",honeywell:\"\u970d\u5c3c\u97e6\u5c14\",city:\"\u57ce\u5e02\u6280\u672f\",figaro:\"\u8d39\u52a0\u7f57\",ecsense:\"\u5fb7\u56fdEC\",sgx:\"SGX\",susa:\"\u82cf\u8428\",hh:\"\u534e\u6df1\u79d1\"};function displayBrand(key,fallback){return isZh&&brandZh[key]?brandZh[key]:String(fallback||key||\"\")}function e(v){return String(v==null?\"\":v).replace(\/[&<>\"']\/g,function(c){return{\"&\":\"&amp;\",\"<\":\"&lt;\",\">\":\"&gt;\",'\"':\"&quot;\",\"'\":\"&#039;\"}[c]})}function t(v){if(v&&typeof v===\"object\")return String((isZh?v.zh:v.en)||v.en||v.zh||\"\");return String(v||\"\")}function option(value,label){return '<option value=\"'+e(value)+'\">'+e(label)+'<\/option>'}function rebuildOptions(){var oldBrand=brand.value,oldGas=gas.value,oldTech=tech.value,oldSeries=series.value;brand.innerHTML=option(\"\",isZh?\"\u5168\u90e8\u54c1\u724c\":\"All Brands\")+data.brands.map(function(b){return option(b.key,displayBrand(b.key,b.name)+\" (\"+b.count+\")\")}).join(\"\");brand.value=oldBrand;gas.innerHTML=option(\"\",isZh?\"\u5168\u90e8\u6c14\u4f53\u7c7b\u578b\":\"All Gas Types\")+data.gases.map(function(g){return option(g.key,g.key+\" \u00b7 \"+t(g.labels))}).join(\"\");gas.value=oldGas;tech.innerHTML=option(\"\",isZh?\"\u5168\u90e8\u68c0\u6d4b\u539f\u7406\":\"All Technologies\")+data.technologies.map(function(x){return option(x.key,t(x.labels))}).join(\"\");tech.value=oldTech;var allowed=data.series.filter(function(s){return !brand.value||s.brandKey===brand.value});series.innerHTML=option(\"\",isZh?\"\u5168\u90e8\u7cfb\u5217\":\"All Series\")+allowed.map(function(s){var b=data.brands.find(function(x){return x.key===s.brandKey});return option(s.key,displayBrand(s.brandKey,b?b.name:s.brandKey)+\" \u00b7 \"+t(s.labels))}).join(\"\");series.value=allowed.some(function(s){return s.key===oldSeries})?oldSeries:\"\"}function localize(force){var language=(document.documentElement.getAttribute(\"lang\")||\"en\").toLowerCase();if(!force&&language===lastLanguage)return false;lastLanguage=language;isZh=language===\"zh\"||language.indexOf(\"zh-\")===0||language.indexOf(\"zh_\")===0;var textAttr=isZh?\"data-zh\":\"data-en\",placeholderAttr=isZh?\"data-placeholder-zh\":\"data-placeholder-en\",ariaAttr=isZh?\"data-aria-zh\":\"data-aria-en\";Array.prototype.forEach.call(root.querySelectorAll(\"[data-en][data-zh]\"),function(el){el.textContent=el.getAttribute(textAttr)});Array.prototype.forEach.call(root.querySelectorAll(\"[data-placeholder-en][data-placeholder-zh]\"),function(el){el.setAttribute(\"placeholder\",el.getAttribute(placeholderAttr))});Array.prototype.forEach.call(root.querySelectorAll(\"[data-aria-en][data-aria-zh]\"),function(el){el.setAttribute(\"aria-label\",el.getAttribute(ariaAttr))});root.setAttribute(\"lang\",isZh?\"zh-CN\":\"en\");rebuildOptions();return true}function searchText(p){return[p.brandName,brandZh[p.brandKey]||\"\",p.model,JSON.stringify(p.aliases||[]),p.partNumber,p.productClass,p.productClassName&&p.productClassName.en,p.productClassName&&p.productClassName.zh,p.series.en,p.series.zh,p.gas,p.gasName.en,p.gasName.zh,JSON.stringify(p.supportedGases||[]),p.tech,p.techName.en,p.techName.zh,p.specs.range,p.description.en,p.description.zh,JSON.stringify(p.specRows||[])].join(\" \").toLowerCase()}function displaySpecValue(p,value){var text=String(value==null?\"\":value);if(!isZh||!p||(!p.embeddedDetails&&p.brandKey!==\"nemoto\"))return text;var words=[[\/\\bCarbon Monoxide\\b\/gi,\"\u4e00\u6c27\u5316\u78b3\"],[\/\\bCarbon Dioxide\\b\/gi,\"\u4e8c\u6c27\u5316\u78b3\"],[\/\\bHydrogen Sulfide\\b\/gi,\"\u786b\u5316\u6c22\"],[\/\\bSulfur Dioxide\\b\/gi,\"\u4e8c\u6c27\u5316\u786b\"],[\/\\bNitrogen Dioxide\\b\/gi,\"\u4e8c\u6c27\u5316\u6c2e\"],[\/\\bNitric Oxide\\b\/gi,\"\u4e00\u6c27\u5316\u6c2e\"],[\/\\bFormaldehyde\\b\/gi,\"\u7532\u919b\"],[\/\\bAcetylene\\b\/gi,\"\u4e59\u7094\"],[\/\\bAcetone\\b\/gi,\"\u4e19\u916e\"],[\/\\b(?:Ethanol|EtOH)\\b\/gi,\"\u4e59\u9187\"],[\/\\biso[- ]?butane\\b\/gi,\"\u5f02\u4e01\u70f7\"],[\/\\bIsobutane\\b\/gi,\"\u5f02\u4e01\u70f7\"],[\/\\bButane\\b\/gi,\"\u4e01\u70f7\"],[\/\\bPropane\\b\/gi,\"\u4e19\u70f7\"],[\/\\bMethane\\b\/gi,\"\u7532\u70f7\"],[\/\\bHydrogen\\b\/gi,\"\u6c22\u6c14\"],[\/\\bAmmonia\\b\/gi,\"\u6c28\u6c14\"],[\/\\bChlorine\\b\/gi,\"\u6c2f\u6c14\"],[\/\\bOzone\\b\/gi,\"\u81ed\u6c27\"],[\/\\bOxygen\\b\/gi,\"\u6c27\u6c14\"],[\/\\bAlcohols?\\b\/gi,\"\u9187\u7c7b\"],[\/\\bRefrigerants?\\b\/gi,\"\u5236\u51b7\u5242\"],[\/\\bAir pollutants?\\b\/gi,\"\u7a7a\u6c14\u6c61\u67d3\u7269\"],[\/\\bInitial alarm accuracy\\b\/gi,\"\u521d\u59cb\u62a5\u8b66\u7cbe\u5ea6\"],[\/\\bInitial output\\b\/gi,\"\u521d\u59cb\u8f93\u51fa\"],[\/\\bSensitivity ratio\\b\/gi,\"\u7075\u654f\u5ea6\u6bd4\"],[\/\\bAlarm set point\\b\/gi,\"\u62a5\u8b66\u8bbe\u5b9a\u70b9\"],[\/\\bAccuracy\\b\/gi,\"\u7cbe\u5ea6\"],[\/\\bfull scale\\b\/gi,\"\u6ee1\u91cf\u7a0b\"],[\/\\btypical\\b\/gi,\"\u5178\u578b\"],[\/\\bApprox\\.?\\b\/gi,\"\u7ea6\"],[\/\\bin air\\b\/gi,\"\u7a7a\u6c14\u4e2d\"],[\/\\bair\\b\/gi,\"\u7a7a\u6c14\"],[\/\\bduty(?: cycle)?\\b\/gi,\"\u5360\u7a7a\u6bd4\"],[\/\\bto\\b\/gi,\"\u81f3\"],[\/\\bof reading\\b\/gi,\"\u8bfb\u6570\"],[\/\\bdiffusion\\b\/gi,\"\u6269\u6563\u5f0f\"],[\/\\bopen-collector outputs?\\b\/gi,\"\u96c6\u7535\u6781\u5f00\u8def\u8f93\u51fa\"],[\/\\bConfiguration-dependent\\b\/gi,\"\u53d6\u51b3\u4e8e\u914d\u7f6e\"],[\/\\bSensor-dependent\\b\/gi,\"\u53d6\u51b3\u4e8e\u6240\u914d\u4f20\u611f\u5668\"],[\/\\bsee datasheet\\b\/gi,\"\u89c1\u8d44\u6599\"],[\/\\bsee product list\\b\/gi,\"\u89c1\u4ea7\u54c1\u5217\u8868\"],[\/\\btwo-wire\\b\/gi,\"\u4e8c\u7ebf\u5236\"],[\/\\bhalf-duplex\\b\/gi,\"\u534a\u53cc\u5de5\"],[\/\\baudible alarm\\b\/gi,\"\u58f0\u97f3\u62a5\u8b66\"],[\/\\bInitial\\b\/gi,\"\u521d\u59cb\u54cd\u5e94\"],[\/\\btypically\\b\/gi,\"\u901a\u5e38\"],[\/\\bLong-life\\b\/gi,\"\u957f\u5bff\u547d\u578b\"],[\/\\bfast\\b\/gi,\"\u5feb\u901f\u578b\"],[\/\\bselected measurement period\\b\/gi,\"\u53d6\u51b3\u4e8e\u6240\u9009\u6d4b\u91cf\u5468\u671f\"],[\/\\bdetection limit\\b\/gi,\"\u68c0\u51fa\u9650\"],[\/\\boptional\\b\/gi,\"\u53ef\u9009\"],[\/\\bnon-condensing\\b\/gi,\"\u65e0\u51b7\u51dd\"]];words.forEach(function(pair){text=text.replace(pair[0],pair[1])});return text.replace(\/\\bunder\\s+([+-]?\\d+(?:\\.\\d+)?)\\s*\u2103\\s*environment\\b\/gi,\"$1 \u2103 \u73af\u5883\u4e0b\").replace(\/\\bin appropriate consumer and small commercial applications\\b\/gi,\"\u9002\u7528\u4e8e\u5bb6\u7528\u53ca\u5c0f\u578b\u5546\u4e1a\u5e94\u7528\").replace(\/\\bwithout condensation\\b\/gi,\"\u65e0\u51b7\u51dd\").replace(\/\\bNot specified by manufacturer\\b\/gi,\"\u539f\u5382\u672a\u6ce8\u660e\").replace(\/\\bless than\\s+\/gi,\"< \").replace(\/\\bmore than\\s+\/gi,\"> \").replace(\/\\bwithin\\s+\/gi,\"\u2264 \").replace(\/\\bincluding\\s+\/gi,\"\u542b \").replace(\/\\byears?\\b\/gi,\"\u5e74\").replace(\/\\bmonths?\\b\/gi,\"\u6708\").replace(\/\\bseconds?\\b\/gi,\"\u79d2\").replace(\/\\bor more\\b\/gi,\"\u6216\u4ee5\u4e0a\").replace(\/\\s+\u6216\u4ee5\u4e0a\/g,\"\u6216\u4ee5\u4e0a\").replace(\/\\bdegree\\s*C\\b\/gi,\"\u2103\").replace(\/\\s+\/g,\" \").trim()}function coreSpecRows(p){return Array.isArray(p.specRows)&&p.specRows.length?p.specRows:[{label:{en:\"Range\",zh:\"\u91cf\u7a0b\"},value:p.specs.range||\"\u2014\"},{label:{en:\"Sensitivity\",zh:\"\u7075\u654f\u5ea6\"},value:p.specs.sensitivity||\"\u2014\"},{label:p.specs.responseLabel||{en:\"Response Time T90\",zh:\"\u54cd\u5e94\u65f6\u95f4 T90\"},value:p.specs.responseTime||\"\u2014\"},{label:{en:\"Resolution\",zh:\"\u5206\u8fa8\u7387\"},value:p.specs.resolution||\"\u2014\"}]}function specGrid(p){var rows=coreSpecRows(p);return '<div class=\"sl-specs\">'+rows.slice(0,4).map(function(row){var value=displaySpecValue(p,(isZh&&row.valueZh?row.valueZh:row.value)||\"\u2014\");return '<div><small>'+e(t(row.label))+'<\/small><strong class=\"notranslate\" translate=\"no\" title=\"'+e(value)+'\">'+e(value)+'<\/strong><\/div>'}).join(\"\")+'<\/div>'}function modalSpecGrid(p){return '<div class=\"sl-modal-specs\">'+coreSpecRows(p).slice(0,4).map(function(row){var value=displaySpecValue(p,(isZh&&row.valueZh?row.valueZh:row.value)||\"\u2014\");return '<div class=\"sl-modal-spec\"><small>'+e(t(row.label))+'<\/small><strong class=\"notranslate\" translate=\"no\">'+e(value)+'<\/strong><\/div>'}).join(\"\")+'<\/div>'}function renderDetailsDialog(p){if(!dialog||!p)return;var desc=(isZh?p.description.zh:p.description.en)||(isZh?p.description.en:p.description.zh)||\"\",descLang=isZh?\"zh-CN\":\"en\";if(isZh)desc=displaySpecValue(p,desc);var brandLabel=displayBrand(p.brandKey,p.brandName);dialogKicker.textContent=isZh?brandLabel+\" \u4f20\u611f\u5668\u8d44\u6599\":brandLabel+\" Sensor Details\";dialogTitle.textContent=p.model;dialogClose.textContent=isZh?\"\u5173\u95ed\":\"Close\";dialogClose.setAttribute(\"aria-label\",isZh?\"\u5173\u95ed\u4f20\u611f\u5668\u8d44\u6599\":\"Close sensor details\");var meta=[brandLabel,p.productClassName?t(p.productClassName):\"\",p.partNumber?(isZh?\"\u6599\u53f7 \":\"Part \")+p.partNumber:\"\",p.gas+\" \u00b7 \"+t(p.gasName),t(p.series),t(p.techName)].filter(Boolean).map(function(value){return '<span>'+e(value)+'<\/span>'}).join(\"\");var extras=[[{en:\"Temperature\",zh:\"\u6e29\u5ea6\"},isZh&&p.specs.temperatureZh?p.specs.temperatureZh:p.specs.temperature],[{en:\"Humidity\",zh:\"\u6e7f\u5ea6\"},isZh&&p.specs.humidityZh?p.specs.humidityZh:p.specs.humidity],[{en:\"Expected Life\",zh:\"\u5bff\u547d\"},isZh&&p.specs.lifetimeZh?p.specs.lifetimeZh:p.specs.lifetime]].filter(function(row){return row[1]}).map(function(row){return '<div><small>'+e(t(row[0]))+'<\/small><strong class=\"notranslate\" translate=\"no\">'+e(displaySpecValue(p,row[1]))+'<\/strong><\/div>'}).join(\"\");var preferred=isZh?\"zh\":\"en\",documents=(p.documents||[]).slice().sort(function(a,b){return(a.lang===preferred?0:1)-(b.lang===preferred?0:1)}),hasReference=documents.some(function(d){return d.match===\"reference\"}),pdfLinks=documents.map(function(d,index){var suffix=documents.length>1?\" \"+(index+1):\"\",baseLabel=({\"datasheet\":isZh?\"\u89c4\u683c\u4e66\":\"Datasheet\",\"user-guide\":isZh?\"\u7528\u6237\u6307\u5357\":\"User Guide\",\"product-list\":isZh?\"\u4ea7\u54c1\u5217\u8868\":\"Product List\",\"protocol\":isZh?\"\u901a\u4fe1\u534f\u8bae\":\"Protocol\",\"application-note\":isZh?\"\u5e94\u7528\u8bf4\u660e\":\"Application Note\"})[d.kind]||(isZh?\"\u6280\u672f\u8d44\u6599\":\"Technical Document\"),label=d.match===\"reference\"?baseLabel+(isZh?\"\uff08\u5f85\u5ba1\u67e5\uff09\":\" (Review)\"):baseLabel;return '<a class=\"sl-btn sl-btn-primary\" href=\"'+e(d.url)+'\" target=\"_blank\" rel=\"noopener\">'+e(label+suffix+\" \u00b7 \"+String(d.lang||\"\").toUpperCase())+'<\/a>'}).join(\"\"),documentNote=p.documentNote?'<p class=\"sl-modal-doc-note\">'+e(t(p.documentNote))+'<\/p>':\"\";var documentBlock=pdfLinks?'<div class=\"sl-modal-documents\"><strong class=\"sl-modal-documents-title\">'+e(hasReference?(isZh?\"\u6280\u672f\u6587\u4ef6\":\"Documents\"):(isZh?\"\u539f\u5382\u6280\u672f\u6587\u4ef6\":\"Manufacturer Documents\"))+'<\/strong><div class=\"sl-actions\">'+pdfLinks+'<\/div>'+documentNote+'<\/div>':documentNote;dialogBody.innerHTML='<div class=\"sl-modal-meta\">'+meta+'<\/div><p id=\"sl-dialog-description\" class=\"sl-modal-description\" lang=\"'+descLang+'\">'+e(desc)+'<\/p>'+modalSpecGrid(p)+(extras?'<div class=\"sl-modal-extra\">'+extras+'<\/div>':\"\")+documentBlock}function openDetailsDialog(p,trigger){if(!dialog||!p)return;activeDetailsProduct=p;lastDetailsTrigger=trigger;renderDetailsDialog(p);if(typeof dialog.showModal===\"function\"){if(!dialog.open)dialog.showModal()}else{dialog.setAttribute(\"open\",\"\")}window.setTimeout(function(){if(dialogClose)dialogClose.focus()},0)}function renderCard(p){var desc=(isZh?p.description.zh:p.description.en)||(isZh?p.description.en:p.description.zh)||\"\",descLang=(isZh&&p.description.zh)?\"zh-CN\":(!isZh&&p.description.en)?\"en\":p.description.zh?\"zh-CN\":\"en\";var extras=[[isZh?\"\u6e29\u5ea6\uff1a\":\"Temperature:\",isZh&&p.specs.temperatureZh?p.specs.temperatureZh:p.specs.temperature],[isZh?\"\u6e7f\u5ea6\uff1a\":\"Humidity:\",isZh&&p.specs.humidityZh?p.specs.humidityZh:p.specs.humidity],[isZh?\"\u5bff\u547d\uff1a\":\"Expected Life:\",isZh&&p.specs.lifetimeZh?p.specs.lifetimeZh:p.specs.lifetime]].filter(function(x){return x[1]}).map(function(x){var value=displaySpecValue(p,x[1]);return '<span><b>'+e(x[0])+'<\/b> <span class=\"notranslate\" translate=\"no\">'+e(value)+'<\/span><\/span>'}).join(\"\");var docs=p.embeddedDetails?'<button type=\"button\" class=\"sl-btn sl-btn-primary sl-details-trigger\" data-product-id=\"'+e(p.id)+'\" aria-haspopup=\"dialog\" aria-controls=\"sl-details-dialog\">'+e(isZh?\"\u67e5\u770b\u8d44\u6599\":\"View Details\")+'<\/button>':(p.documents||[]).slice().sort(function(a,b){var lang=isZh?\"zh\":\"en\";return(a.lang===lang?0:1)-(b.lang===lang?0:1)}).map(function(d){return '<a class=\"sl-btn sl-btn-primary\" href=\"'+e(d.url)+'\" target=\"_blank\" rel=\"noopener\">'+e(isZh?\"\u67e5\u770b\u8d44\u6599\":\"View Documents\")+' \u00b7 '+e(String(d.lang||\"\").toUpperCase())+'<\/a>'}).join(\"\");if(!docs)docs='<span class=\"sl-btn sl-btn-disabled\">'+e(isZh?\"\u6682\u65e0\u8d44\u6599\":\"Documents Unavailable\")+'<\/span>';return '<article class=\"sl-card\" data-product-id=\"'+e(p.id)+'\" data-brand-key=\"'+e(p.brandKey)+'\" data-gas=\"'+e(p.gas)+'\" data-tech=\"'+e(p.tech)+'\" data-series-key=\"'+e(p.seriesKey)+'\"><div class=\"sl-card-top\"><span class=\"sl-brand notranslate\" translate=\"no\" data-brand-key=\"'+e(p.brandKey)+'\">'+e(displayBrand(p.brandKey,p.brandName))+'<\/span><span class=\"sl-gas\"><span class=\"notranslate\" translate=\"no\">'+e(p.gas)+'<\/span> \u00b7 '+e(t(p.gasName))+'<\/span><\/div><div class=\"sl-image-wrap\"><img loading=\"lazy\" class=\"sl-product-image\" src=\"'+e(p.imageUrl)+'\" alt=\"'+e(displayBrand(p.brandKey,p.brandName)+\" \"+p.model+\" \"+(isZh?\"\u6c14\u4f53\u4f20\u611f\u5668\":\"gas sensor\"))+'\" loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"360\"><\/div><h3 class=\"notranslate\" translate=\"no\">'+e(p.model)+'<\/h3><p class=\"sl-series\">'+e(t(p.series))+' \u00b7 '+e(t(p.techName))+'<\/p>'+specGrid(p)+'<div class=\"sl-extra\">'+extras+'<\/div>'+(desc&&!p.embeddedDetails?'<details><summary>'+(isZh?\"\u4ea7\u54c1\u8bf4\u660e\":\"Product Details\")+'<\/summary><p lang=\"'+descLang+'\">'+e(desc)+'<\/p><\/details>':\"\")+'<div class=\"sl-actions\">'+docs+'<\/div><\/article>'}function syncQuick(){Array.prototype.forEach.call(root.querySelectorAll(\".sl-brand-quick\"),function(button){button.classList.toggle(\"is-active\",button.getAttribute(\"data-brand-key\")===brand.value)})}function apply(){var q=(search.value||\"\").trim().toLowerCase(),tokens=q?q.split(\/\\s+\/):[];matched=data.products.filter(function(p){var haystack=searchText(p);return(!tokens.length||tokens.every(function(token){return haystack.indexOf(token)!==-1}))&&(!brand.value||p.brandKey===brand.value)&&(!gas.value||p.gas===gas.value||(Array.isArray(p.supportedGases)&&p.supportedGases.indexOf(gas.value)!==-1))&&(!tech.value||p.tech===tech.value)&&(!series.value||p.seriesKey===series.value)});var pages=Math.max(1,Math.ceil(matched.length\/data.perPage));if(page>pages)page=pages;grid.innerHTML=matched.slice((page-1)*data.perPage,page*data.perPage).map(renderCard).join(\"\");count.textContent=isZh?\"\u5171 \"+matched.length+\" \u4e2a\u578b\u53f7\":matched.length+\" \"+(matched.length===1?\"model\":\"models\");pageLabel.textContent=isZh?\"\u7b2c \"+page+\" \u9875\":\"Page \"+page;pageText.textContent=page+\" \/ \"+pages;prev.disabled=page<=1;next.disabled=page>=pages;empty.hidden=matched.length!==0;syncQuick()}grid.addEventListener(\"click\",function(event){var trigger=event.target&&event.target.closest?event.target.closest(\".sl-details-trigger\"):null;if(!trigger||!grid.contains(trigger))return;var productId=trigger.getAttribute(\"data-product-id\"),product=data.products.find(function(item){return item.id===productId});if(!product||!product.embeddedDetails)return;openDetailsDialog(product,trigger)});dialogClose.addEventListener(\"click\",function(){if(dialog.open)dialog.close()});dialog.addEventListener(\"click\",function(event){if(event.target===dialog&&dialog.open)dialog.close()});dialog.addEventListener(\"keydown\",function(event){if(event.key===\"Escape\"&&dialog.open){event.preventDefault();dialog.close()}});dialog.addEventListener(\"close\",function(){var trigger=lastDetailsTrigger;lastDetailsTrigger=null;activeDetailsProduct=null;window.setTimeout(function(){if(!dialog.open&&trigger&&trigger.isConnected&&typeof trigger.focus===\"function\")trigger.focus({preventScroll:true})},0)});search.addEventListener(\"input\",function(){page=1;apply()});brand.addEventListener(\"change\",function(){page=1;rebuildOptions();apply()});[gas,tech,series].forEach(function(el){el.addEventListener(\"change\",function(){page=1;apply()})});root.querySelector(\"#sl-reset\").addEventListener(\"click\",function(){search.value=\"\";brand.value=\"\";gas.value=\"\";tech.value=\"\";series.value=\"\";page=1;rebuildOptions();apply()});Array.prototype.forEach.call(root.querySelectorAll(\".sl-brand-quick\"),function(button){button.addEventListener(\"click\",function(){brand.value=button.getAttribute(\"data-brand-key\")||\"\";series.value=\"\";page=1;rebuildOptions();apply()})});prev.addEventListener(\"click\",function(){if(page>1){page--;apply();root.scrollIntoView({behavior:\"smooth\",block:\"start\"})}});next.addEventListener(\"click\",function(){var pages=Math.max(1,Math.ceil(matched.length\/data.perPage));if(page<pages){page++;apply();root.scrollIntoView({behavior:\"smooth\",block:\"start\"})}});localize(true);apply();if(window.MutationObserver)new MutationObserver(function(){if(localize(false)){if(dialog){if(dialog.open)dialog.close()}apply()}}).observe(document.documentElement,{attributes:true,attributeFilter:[\"lang\"]})})();<\/script>\n\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_surecart_dashboard_logo_width":"180px","_surecart_dashboard_show_logo":true,"_surecart_dashboard_navigation_orders":true,"_surecart_dashboard_navigation_invoices":true,"_surecart_dashboard_navigation_subscriptions":true,"_surecart_dashboard_navigation_downloads":true,"_surecart_dashboard_navigation_billing":true,"_surecart_dashboard_navigation_account":true,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-9067","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false,"woocommerce_thumbnail":false,"woocommerce_single":false,"woocommerce_gallery_thumbnail":false},"uagb_author_info":{"display_name":"mathiasdeclue","author_link":"https:\/\/airmate.cc\/zh\/author\/mathiasdeclue\/"},"uagb_comment_info":0,"uagb_excerpt":null,"_links":{"self":[{"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/pages\/9067","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/comments?post=9067"}],"version-history":[{"count":26,"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/pages\/9067\/revisions"}],"predecessor-version":[{"id":9872,"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/pages\/9067\/revisions\/9872"}],"wp:attachment":[{"href":"https:\/\/airmate.cc\/zh\/wp-json\/wp\/v2\/media?parent=9067"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}